Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Do We Really Need All That Data: From Data to Agency in Automated Microscopy

Microscopy is entering an era of automated laboratories and AI-enabled instruments, often justified by a simple narrative of automating experiments to collect more data and train better models. In this work, we argue that, for microscopy, this framing is incomplete and can be counterproductive.

97 MATHEMATICS AND COMPUTING↗

CalCharge CRADA000008852 Master Agreement Amendment 1, Battery Consortium – Proprietary Activities

Lawrence Berkeley National Laboratory (LBNL) is partnering with the California Clean Energy Fund to launch CalCharge, an energy storage innovation accelerator, comprised of emerging and established California companies and related organizations developing battery technologies for the electric/hybrid vehicle transportation, the electric grid and consumer electronics markets. The vision of CalCharge is to accelerate the pace of technology innovation, business growth, and cluster development. Calcharge programs will deliver technology acceleration and technical expertise to the energy storage industry, as well as policy and market development support to strengthen the regional economy. LBNL shall collaborate with CalCharge members on the analysis and testing of battery and energy storage technologies. LBNL’s work will include analysis and testing of external design, examination of materials and components either separately or as a whole, and providing data and observations resulting from each collaboration. LBNL shall maintain and provide access to LBNL specialized facilities for research activities performed by or for CalCharge members. In addition, LBNL will provide expertise for short-term consultation, interpretation of testing data, or to clarify technical obstacles if requested by a Member. Over this time frame, Calcharge partnered with several start-ups to provide analytical resources. Those companies include Halotechnics, ZAF Energy Systems, Volkswagen Group of America, Toyota Motor Corporation, and Ensor Inc.

25 ENERGY STORAGE↗

The variability structure function of the highest luminosity quasars on short time-scales

ABSTRACT The stochastic photometric variability of quasars is known to follow a random-walk phenomenology on emission time-scales of months to years. Some high-cadence rest-frame optical monitoring in the past has hinted at a suppression of variability amplitudes on shorter time-scales of a few days or weeks, opening the question of what drives the suppression and how it might scale with quasar properties. Here, we study a few thousand of the highest luminosity quasars in the sky, mostly in the luminosity range of $L_{\rm bol}$$=[46.4, 47.3]$ and redshift range of $z=[0.7, 2.4]$. We use a data set from the NASA/Asteroid Terrestrial-impact Last Alert System facility with nightly cadence, weather permitting, which has been used before to quantify strong regularity in longer term rest-frame-UV variability. As we focus on a careful treatment of short time-scales across the sample, we find that a linear function is sufficient to describe the UV variability structure function. Although the result can not rule out the existence of breaks in some groups completely, a simpler model is usually favoured under this circumstance. In conclusion, the data are consistent with a single-slope random walk across rest-frame time-scales of $\Delta t=[10, 250]$ d.

Tang, Ji-Jia (ORCID:0000000218600886)↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

A Novel Approach for Computing Rigid Body Motion Using Linear Accelerations

Here, a novel approach is presented for computing general rigid body motion based on a few known linear accelerations. This method utilizes linear acceleration data obtained from three distinct points on the body, all within a body-fixed reference frame. The only requirement is that the three chosen points must not be collinear. A system of differential-algebraic equations is derived, combining principles of rigid body kinematics with theory of the rotation group SO(3). These equations provide a framework for numerically computing various motion parameters, including angular velocity, angular acceleration, body orientation, velocity field, acceleration field, and displacement field. By numerically solving this system of equations, we can fully characterize rigid body motion in three-dimensional space. A numerical example is provided to demonstrate the practical implementation and efficacy of the proposed technique, illustrating its potential for accurate motion computation in various applications.

42 ENGINEERING↗

High-Resolution Sampling of a River Plume Front with Uncrewed Underwater and Aerial Vehicles

Sampling fast-propagating oceanic features is inherently challenging and demands versatile instrumentation and innovative strategies. This paper introduces a novel sampling strategy designed to capture such phenomena, exemplified by a river plume front. Our method revolves around modifying the preprogrammed pathway of an uncrewed underwater vehicle (UUV) to dynamically track and three-dimensionally sample the evolution of the front. To enable the UUV to follow the feature, we adapt the use of a drifting gateway buoy to be positioned and trapped at the front’s convergence zone, allowing underway navigation relative to the buoy. In our demonstration, we showcase the effectiveness of this strategy by successfully conducting over 30 crossings of a river plume front within a 6-h window. The UUV sensors allowed a comprehensive assessment of key front characteristics, including density, velocity, and turbulence. Supplemental drone footage contributed to the overall picture and facilitated the transformation of the dataset into a front-following reference frame. This article provides an in-depth description of the deployment strategy and required postcollection data processing, including frontal crossing detection, the assessment of the frontal orientation from drone footage, and defining the plume bottom boundaries using backscatter intensity contours.

autonomous observations↗

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Probing the influence of ion-pairing on ligand-field excited-state dynamics

Exploration of the photophysical and photochemical properties of transition metal complexes has driven ground-breaking advancements in solar energy conversion technologies, including photoredox catalysis. While significant research has been devoted to understanding excited state properties of second- and third-row transition metal complexes, earth-abundant first-row metal complexes have received comparatively little attention in this context until very recently. In particular, the role of ion-pairing – which has been identified as a potentially significant factor for Ir(III)-based photosensitizers – has not been examined with regard to its influence on the ligand-field excited states that dominate much of first-row photophysics. A key challenge in studying ion-pair interactions lies in quantifying the extent and nature of ion-pairing, particularly in non-aqueous media where the vast majority of photophysical studies are performed. Cobalt(III) polypyridyl complexes provide an attractive platform to address such questions due to their demonstrated potential for applications in photoredox catalysis involving ligand-field excited states. In the present study, we prepared a cobalt(III) polypyridyl complex, [Co(4,4′-OMebpy) 3 ](BAr F 4 ) 3 (where 4,4′-OMebpy is 4,4′-dimethoxy-2,2′-bipyridine and BAr F 4 is tetrakis(3,5-bis(trifluoromethyl)-phenyl)borate) to probe ion-pairing in non-aqueous solutions. Specifically, analysis of data acquired from both variable-temperature diffusion ordered spectroscopy (DOSY) NMR and 1-D rotating-frame nuclear Overhauser effect (ROE) experiments allowed us to identify and differentiate between solvent-separated ion pairs in high-dielectric media and contact ion pairs in a low-dielectric solvent. Time-resolved absorption spectroscopy was then used to measure ground-state recovery dynamics under these varying conditions of ion-pairing, the results of which revealed an increase in excited-state lifetime for contact ion-pairs that we suggest arises from a reduction in outer-sphere reorganization energy relative to conditions which favored solvent-separated ion pairs. We believe this study demonstrates that one can leverage broadly available NMR-based methods to understand ion-pairing in non-aqueous solutions, which in turn can provide a microscopic picture of intermolecular interactions that can impact the photophysical properties of transition metal-based chromophores.

Ghosh, Atanu [Michigan State University, East Lans↗

Methods of Securing Chemical and Pharmaceutical Knowledge and Recommendations for International Institutions to Enhance Research Integrity

Here, this paper examines strategies for securing chemical and pharmaceutical expertise in a globalized research environment, focusing on safeguarding intellectual property and preventing the misuse of sensitive and potentially dual-use information. The product of collective efforts between Pacific Northwest National Laboratory, Carol Davila University of Medicine and Pharmacy, and New Bulgarian University, highlights the challenges and opportunities posed by cross-border research collaborations, particularly in the context of differing regulatory frameworks and research cultures. It explores current mechanisms to prevent data loss and unauthorized access to sensitive information while assessing the effectiveness of existing security measures, frameworks, and international export control regimes. The approach examines the differing methodologies for promoting transparency, trust-building, and mutual accountability in joint research projects to cultivate secure data-sharing practices and intellectual property. It provides recommendations for international institutions to implement security guidelines in framing research priorities, encourages continual training and education programs, and the integration of processes for monitoring research compliance. This partnership aims to advance scientific innovation while maintaining global stability, ensuring compliance with international norms, and safeguarding valuable intellectual property as measures in chemical and pharmaceutical research security practices continue to expand due to international collaboration and knowledge exchange.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Measurements of the Lyα Forest Continuum and Effective Optical Depth with LyCAN and DESI Y1 Data

Abstract We present the Ly α Continuum Analysis Network (LyCAN), a convolutional neural network that predicts the unabsorbed quasar continuum within the rest-frame wavelength range of 1040–1600 Å based on the red side of the Ly α emission line (1216–1600 Å). We developed synthetic spectra based on a Gaussian mixture model representation of nonnegative matrix factorization (NMF) coefficients. These coefficients were derived from high-resolution, low-redshift ( z < 0.2) Hubble Space Telescope/Cosmic Origins Spectrograph (COS) quasar spectra. We supplemented this COS-based synthetic sample with an equal number of DESI Year 5 mock spectra. LyCAN performs extremely well on testing sets, achieving a median error in the forest region of 1.5% on the DESI mock sample, 2.0% on the COS-based synthetic sample, and 4.1% on the original COS spectra. LyCAN outperforms principal component analysis (PCA) and NMF-based prediction methods using the same training set by 40% or more. We predict the intrinsic continua of 83,635 DESI Year 1 spectra in the redshift range of 2.1 ≤ z ≤ 4.2 and perform an absolute measurement of the evolution of the effective optical depth. This is the largest sample employed to measure the optical depth evolution to date. We fit a power law of the form τ ( z ) = τ 0 ( 1 + z ) γ to our measurements and find τ 0 = (2.46 ± 0.14) × 10 −3 and γ = 3.62 ± 0.04. Our results show particular agreement with high-resolution, ground-based observations around z = 2, indicating that LyCAN is able to predict the quasar continuum in the forest region with only spectral information outside the forest.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing inference of segmentation on high-resolution images in MLExchange

MLExchange is a machine learning (ML) operations platform providing web user-interfaces (UIs) for data visualization and analysis pipelines at synchrotron facilities. Among these UIs is the segmentation app which helps synchrotron users utilize ML algorithms to automatically segment high-resolution scientific images with minimal manual annotation effort. In this work, we share code optimizations that significantly speed up the segmentation inference workflow of large data in short time. By optimizing the sequence of CPU-GPU data transfers and introducing CPU parallelization to key operations, we improve the per-device, per-image frame computational efficiency and observe close to 3×$$\times$$ speedup over the original segmentation inference workflow run time when utilizing a single GPU. Further adaptations enabling multi-GPU inference yield more than 40×$$\times$$ speedup with 100 GPUs compared to the optimized single GPU inference workflow. This acceleration of the segmentation inference workflow will provide MLExchange users with easy access to segmentation results with little wait time.

Lu, Shizhao↗

Entanglement, trace anomaly, and confinement in QCD

We formulate confinement in quantum chromodynamics (QCD) as an entropic surface phenomenon. Quark and gluon quantum information is localized on a transverse, entangling two-sphere of radius 𝑅 𝐸⁢𝐸 ; at this radius the QCD vacuum—partitioned by a hadron into interior and exterior regions—reaches its maximal entanglement entropy. Lattice-QCD determinations of the scalar (trace) gravitational form factors fix both 𝑅 𝐸⁢𝐸 and the transverse trace-anomaly density 𝜌 ℎ ⁡(𝑅 𝐸⁢𝐸 ), yielding a parameter-free slope 𝑐 ℎ = 8⁢𝜋 2 ⁢𝑅𝑆$^2_{𝐸⁢𝐸}$𝜌 ℎ ⁡(𝑅 𝐸⁢𝐸 ) and a mechanical entropy 𝑆 𝐸⁢𝐸 ⁡(𝑦) = 𝑐 ℎ ⁢𝑦 that grows linearly with rapidity 𝑦. The entropy gradient ∂ 𝑅 𝑆 𝐸⁢𝐸 changes sign at 𝑅 𝐸⁢𝐸 : it pushes colored degrees of freedom outward for 𝑟 <𝑅 𝐸⁢𝐸 and pulls them inward for 𝑟 >𝑅 𝐸⁢𝐸 , thereby localizing them on the codimension-2 entangling two-sphere Σ ⊥ = 𝑆$^2_{𝑅_{𝐸⁢𝐸}}$ (which, in the infinite-momentum frame (IMF), projects onto the transverse plane)—the “information wall.” This provides a high-energy (large-𝑦) entropic confinement diagnostic that complements—rather than replaces—Wilson’s area-law criterion, which probes long-distance dynamics near the rest frame (𝑦 → 0). Imposing unitarity on an entropic ansatz for the amplitude yields 𝜎⁡(𝑠) ∝ 𝑦 𝛿 . World data favor 𝛿 = 2 for elastic 𝑝⁡𝑝⁡($𝑝\bar{⁡𝑝}$) scattering and heavy-quark photoproduction, whereas 𝜙 photoproduction favors a softer 𝛿 = 0.387. All extracted cross sections remain well below the Froissart-Martin bound. These results provide a confinement criterion quantified directly from nonperturbative QCD inputs, unifying the trace anomaly, entanglement entropy, and high-energy scattering within a single quantitative framework.

Color confinement↗

Deep learning-based spatio-temporal fusion for high-fidelity ultra-high-speed X-ray radiography

Full-field ultra-high-speed (UHS) X-ray imaging experiments have been well established to characterize various processes and phenomena. However, the potential of UHS experiments through the joint acquisition of X-ray videos with distinct configurations has not been fully exploited. In this paper, we investigate the use of a deep learning-based spatio-temporal fusion (STF) framework to fuse two complementary sequences of X-ray images and reconstruct the target image sequence with high spatial resolution, high frame rate and high fidelity. We applied a transfer learning strategy to train the model and compared the peak signal-to-noise ratio (PSNR), average absolute difference (AAD) and structural similarity (SSIM) of the proposed framework on two independent X-ray data sets with those obtained from a baseline deep learning model, a Bayesian fusion framework and the bicubic interpolation method. The proposed framework outperformed the other methods with various configurations of the input frame separations and image noise levels. With three subsequent images from the low-resolution (LR) sequence of a four times lower spatial resolution and another two images from the high-resolution (HR) sequence of a 20 times lower frame rate, the proposed approach achieved average PSNRs of 37.57 dB and 35.15 dB, respectively. When coupled with the appropriate combination of high-speed cameras, the proposed approach will enhance the performance and therefore the scientific value of UHS X-ray imaging experiments.

deep learning↗

Detecting outbreaks using a spatial latent field

In this paper, we present a method for estimating the infection-rate of a disease as a spatial-temporal field. Our data comprises time-series case-counts of symptomatic patients in various areal units of a region. We extend an epidemiological model, originally designed for a single areal unit, to accommodate multiple units. The field estimation is framed within a Bayesian context, utilizing a parameterized Gaussian random field as a spatial prior. We apply an adaptive Markov chain Monte Carlo method to sample the posterior distribution of the model parameters condition on COVID-19 case-count data from three adjacent counties in New Mexico, USA. Our results suggest that the correlation between epidemiological dynamics in neighboring regions helps regularize estimations in areas with high variance (i.e., poor quality) data. Using the calibrated epidemic model, we forecast the infection-rate over each areal unit and develop a simple anomaly detector to signal new epidemic waves. Our findings show that anomaly detector based on estimated infection-rates outperforms a conventional algorithm that relies solely on case-counts.

Safta, Cosmin [Sandia National Laboratories (SNL-C↗

Lattice QCD Study of Pion Electroproduction and Weak Production from a Nucleon

Quantum fluctuations in QCD influence nucleon structure and interactions, with pion production serving as a key probe of chiral dynamics. In this Letter, we present a lattice QCD calculation of multipole amplitudes at threshold, related to both pion electroproduction and weak production from a nucleon, using two gauge ensembles near the physical pion mass. We develop a technique for spin projection and construct multiple operators for analyzing the generalized eigenvalue problem in both the nucleon-pion system in the center-of-mass frame and the nucleon system with nonzero momentum. The numerical lattice results are then compared with those extracted from experimental data and predicted by low-energy theorems incorporating one-loop corrections. Published by the American Physical Society 2025

Gao, Yu-Sheng (ORCID:0009000406829247)↗