Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A New High Channel-Count, High Scan-Rate, Data Acquisition System for the NASA Langley Transonic Dynamics Tunnel

A data acquisition system upgrade project, known as AB-DAS, is underway at the NASA Langley Transonic Dynamics Tunnel. AB-DAS will soon serve as the primary data system and will substantially increase the scan-rate capabilities and analog channel count while maintaining other unique aeroelastic and dynamic test capabilities required of the facility. AB-DAS is configurable, adaptable, and enables buffet and aeroacoustic tests by synchronously scanning all analog channels and recording the high scan-rate time history values for each data quantity. AB-DAS is currently available for use as a stand-alone data system with limited capabilities while development continues. This paper describes AB-DAS, the design methodology, and the current features and capabilities. It also outlines the future work and projected capabilities following completion of the data system upgrade project.

Ivanco, Thomas G.↗

High frequency data acquisition system for space shuttle main engine testing

The high frequency data acquisition system developed for the Space Shuttle Main Engine (SSME) single engine test facility at the National Space Technology Laboratories is discussed. The real time system will provide engineering data for a complete set of SSME instrumentation (approx. 100 measurements) within 4 hours following engine cutoff, a decrease of over 48 hours from the previous analog tape based system.

Lewallen, Pat↗

ASRC Aerospace Corporation Selects Dynamically Reconfigurable Anadigm(Registered Trademark) FPAA For Advanced Data Acquisition System

Anadigm(registered trademark) today announced that ASRC Aerospace Corporation has designed Anadigm's dynamically reconfigurable Field Programmable Analog Array (FPAA) technology into an advanced data acquisition system developed under contract for NASA. ASRC Aerospace designed in the Anadigm(registered trademark) FPAA to provide complex analog signal conditioning in its intelligent, self-calibrating, and self-healing advanced data acquisition system (ADAS). The ADAS has potential applications in industrial, manufacturing, and aerospace markets. This system offers highly reliable operation while reducing the need for user interaction. Anadigm(registered trademark)'s dynamically reconfigurable FPAAs can be reconfigured in-system by the designer or on the fly by a microprocessor. A single device can thus be programmed to implement multiple analog functions and/or to adapt on-the-fly to maintain precision operation despite system degradation and aging. In the case of the ASRC advanced data acquisition system, the FPAA helps ensure that the system will continue to operating at 100% functionality despite changes in the environment, component degradation, and/or component failures.

Mata, Carlos T.↗

An adaptive structure data acquisition system using a graphical-based programming language

An example of the implementation of data fusion using a PC and a graphical programming language is discussed. A schematic of the data acquisition system and user interface panel for an adaptive structure test are presented. The computer programs (a series of icons 'wired' together) are also discussed. The way in which using graphical-based programming software to control a data acquisition system can simplify analysis of data, promote multidisciplinary interaction, and provide users a more visual key to understanding their data are shown.

Baroth, Edmund C.↗

Two-Year Operational Evaluation Of A Consumer Electronics-Based Data Acquisition System For Equipment Monitoring

Oak Ridge National Laboratory (ORNL) has performed a two-year evaluation of the performance of an in-house developed consumer electronics-based data acquisition system (DAS). The main advantage of this approach compared to conventional instrumentation grade systems is cost; instrument grade data acquisition systems average costs range from $800 to $2,000 per channel compared to a range of $200 - $400 per channel for a consumer electronics-based system. The DAS is operated as a full-time in-situ vibration monitor. The resulting data stream is streamed over the ORNL network, at an aggregate rate of approximately 2 megabytes/s, to a Linux server. The server includes the capability to implement event-triggered data stores, as well as real-time files for the implementation of continuous display monitoring of the spectra. Detailed spectral analysis is performed post event. The DAS is installed on a large industrial chiller and cooling water pump associated with ORNL’s Titan supercomputer. These mechanical systems include rotating components that operate at fundamental frequencies within the range of 30 Hz to over 3 KHz. Evaluation of the DAS data over a two-year operating period leads to the conclusion that for many industrial processes this system could form the basis for a cost effective means of obtaining operating health data in real time from rotating machinery. The deployment has also shown that the DAS technology is reliable. Furthermore, because the cost of the DAS is low, the other significant advantage of this approach is that the DAS can be deployed in a dedicated manner and operated on a full-time basis.

Wetherington Jr, G↗

A computer-controlled, on-board data acquisition system for wind-tunnel testing

A computer-controlled data acquisition system has been developed for the 40x80-foot wind tunnel at Ames Research Center. The system, consisting of several small onboard units installed in the model and a data-managing, data-displaying ground station, is capable of sampling up to 256 channels of raw data at a total sample rate of 128,000 samples/sec. Complete signal conditioning is contained within the on-board units. The sampling sequence and channel gain selection is completely random and under total control of the ground station. Outputs include a bar-graph display, digital-to-analog converters, and digital interface to the tunnel's central computer, an SEL 840MP. The system can be run stand-alone or under the control of the SEL 840MP.

Finger, H. J.↗

Real-time detection and data acquisition system for the left ventricular outline

To automate the data acquisition procedure, a real-time contour detection and data acquisition system for the left ventricular outline was developed using video techniques. The X-ray image of the contrast-filled left ventricle is stored for subsequent processing on film (cineangiogram), video tape or disc. The cineangiogram is converted into video format using a television camera. The video signal from either the TV camera, video tape or disc is the input signal to the system. The contour detection is based on a dynamic thresholding technique. Since the left ventricular outline is a smooth continuous function, for each contour side a narrow expectation window is defined in which the next borderpoint will be detected. A computer interface was designed and built for the online acquisition of the coordinates using a PDP-12 computer. The advantage of this system over other available systems is its potential for online, real-time acquisition of the left ventricular size and shape during angiocardiography.

Reiber, J. H. C.↗

Cardiopulmonary data acquisition system. Version 2.0, volume 1: User's guide

The Cardiopulmonary Data Acquisition System is a computerized method of both collecting and analyzing physiological data on subjects during a treadmill or ergometer stress test in the clinic. The real time acquisition of the physiological data, such as, heart rate, blood pressure, work load, and respiratory gases is accomplished by an LSI-11 microcomputer which displays this data on a hard copy terminal. The data are also concurrently stored on a mass storage device and anytime after the test period a selectable number of copies of the plots or minute reports can be reproduced at the terminal.

Source record↗

Electronics of the data acquisition system of the DANSS detector based on silicon photomultipliers

The electronics of the data acquisition system based on silicon photomultipliers is briefly described. The elements and modules of the system were designed and constructed at ITEP especially for the DANSS detector. Examples of digitized signals obtained with the presented electronic modules and selected results on processing of the DANSS engineering data-taking run in spring 2016 are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Requirements Document for a Replacement Data Acquisition System

A flight vehicle is in the developmental stages. While in development flight testing is required by both the manufacturer and customer to rate design performance. The performance of the vehicle must fulfill the agreed upon requirements. Testing of a flight vehicle during operation requires various sensors in order to record and monitor performance for evaluation. A Data Acquisition System (DAQ) is needed in order to control and capture data from various sensors placed throughout the vehicle during flight. This DAQ will receive the analog data from the suite of sensors and convert them to a digital signal that can be transmitted to a recording station where the data will later be analyzed by test experts. Some of the key features to be included in the DAQ will be a self-check operation to verify the health of all sensors including the DAQ. The DAQ will also have the capability to store sensor calibration data files loaded during assembly and transmit those files to the recording station during flight. Breakthroughs in new technologies has allowed for higher resolution recording systems and faster sampling rates. Improved sensor data using a new Data Acquisition System (DAQ) can provide important answers to questions discovered during the last few flight tests. These questions arose when the flight system expressed unexpected behaviors. Having the capability of the new DAQ in flight tests would allow for more high-fidelity data to be captured from the system during flight tests and ultimately reducing the number of required flight test. Reducing the number of flight tests also reduce developmental cost and schedule.

42 ENGINEERING↗

Low-power portable geophysical data acquisition system and its use in geomagnetic measurements

A low-power portable data acquisition system presently in use for geomagnetic measurements is described. The system is composed of a data-processing system containing a low-power microprocessor, a 9-track digital tape recorder, and a rechargeable battery pack. The magnetometer is a low-power three axis fluxgate design. Under program control the data processing system keeps track of time of day and date, samples three analog magnetometer outputs at intervals of either 0.4 or 2 s, digitizes the data to 15-bit resolution, and, depending upon relative magnetic activity, decides upon data compression to increase the tape storage capacity. It also monitors and records internal voltages and provides self-checking functions which may be monitored through a visual readout on the control panel. The system is mounted in a rugged, weather-tight carrying case suitable for use outdoors with minimal protection. The system, including magnetometer, uses 1.6-W power and can store 5.7 Mbytes of data.

Medford, L. V.↗

Infrared spectrometry studies: Spectral digital data acquisition system (1971 version)

The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.

Lu, L.↗

Development of a simple, self-contained flight test data acquisition system

This paper describes a simple, self-contained flight test data acquisition system. The system makes use of the latest sensor and microprocessor technology available, to reduce overall system costs. Coupled with this is the use of modern control theory techniques allowing minimization of data requirements, as well as flight time requirements. Capability of the system includes primarily stability and performance analysis of general aviation airplanes, although system versatility has been designed into the package. Presented are details of the prototype system constructed, as well as details of the data reduction technique utilized. Preliminary results of the flight test program have also been included which demonstrate the capability of this system.

Renz, R. R. L.↗

Digital data acquisition system implementation at the National Superconducting Cyclotron Laboratory

A Digital Data Acquisition System (DDAS) composed of 16-channel FPGA-programmable modules running 12-bit 100 Mega-Samples Per Second (MSPS) ADCs has been implemented on three different experimental arrays at the National Superconducting Cyclotron Laboratory (NSCL) encompassing charged particle spectroscopy, high and low energy-resolution photon detection, and neutron time-of-flight measurements. DDAS has increased the experimental capabilities of each array by providing energy and time measurements with nearly zero dead-time, low energy thresholds, and large dynamic range. The performance of the DDAS Analog-to-Digital Converters (ADC)s was characterized, and energy and time resolutions were compared with traditional analog systems. We have demonstrated a 14- to 15-bit peak-sensing equivalent resolution when applied to semiconductor detectors and 500 ps time resolution for LaBr 3 detectors measuring coincident radiation with signal amplitudes of ≈13% of the input range of the ADC. Details regarding the operation of the system at NSCL including digital filtering, triggering, clock distribution, and event-building are discussed along with applications to selected detector systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Self-Calibrating, Self-Repairing Data Acquisition System

An improved self-calibrating and self-repairing Data Acquisition System (DAS) for use in inaccessible areas, such as onboard spacecraft, and capable of autonomously performing required system health checks, failure detection. When required, self-repair is implemented utilizing a "spare parts/tool box" system. The available number of spare components primarily depends upon each component's predicted reliability which may be determined using Mean Time Between Failures (MTBF) analysis. Failing or degrading components are electronically removed and disabled to reduce power consumption, before being electronically replaced with spare components.

Pedro J Medelius↗

A real time data acquisition system using the MIL-STD-1553B bus

A flight digital data acquisition system that uses the MIL-STD-1553B bus for transmission of data to a host computer for control law processing is described. The instrument, the Remote Interface Unit (RIU), can accommodate up to 16 input channels and eight output channels. The RIU employs a digital signal processor to perform local digital filtering before sending data to the host. The system allows flexible sensor and actuator data organization to facilitate quick control law computations on the host computer. The instrument can also run simple control laws autonomously without host intervention. The RIU and host computer together have replaced a similar larger, ground minicomputer system with favorable results.

Peri, Frank, Jr.↗