Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

GNN-based end-to-end reconstruction in the CMS Phase 2 High-Granularity Calorimeter

We present the current stage of research progress towards a one-pass, completely Machine Learning (ML) based imaging calorimeter reconstruction. The model used is based on Graph Neural Networks (GNNs) and directly analyzes the hits in each HGCAL endcap. The ML algorithm is trained to predict clusters of hits originating from the same incident particle by labeling the hits with the same cluster index. We impose simple criteria to assess whether the hits associated as a cluster by the prediction are matched to those hits resulting from any particular individual incident particles. The algorithm is studied by simulating two tau leptons in each of the two HGCAL endcaps, where each tau may decay according to its measured standard model branching probabilities. The simulation includes the material interaction of the tau decay products which may create additional particles incident upon the calorimeter. Using this varied multiparticle environment we can investigate the application of this reconstruction technique and begin to characterize energy containment and performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADRIANO2 Calorimeter performance from 2022 Prototypes

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration research program. The building block of ADRIANO2 Calorimeter consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. The two components of the dual-readout energy compensation technique. Furthermore,Cˇerenkovlightfromtheleadglassareexploitedtoforhighresolutiontimingmeasurements,whilehigh granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle identification for REDTOP as it is crucial for a calorimeter to detect and identify the decay products of eta/eta-prime mesons. Measurements were collected on several ADRIANO2 prototypes between February to December 2022 to evaluate the detector performance. The key metrics extracted from the analyses are presented in this paper are the efficiencies and light-yi eld for various tile configurations. The measured values will be used as input parameters for improved REDTOP Montecarlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing ICARUS and REDTOP Software and Hardware: Event Generator Interface Development and Calorimeter Tile Prototype

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.] (ORCID:0009000184↗

CaloTrilogy: Toward a Breakthrough in One-Step, End-to-End, Physics-Guided Shower Generation for Modern Calorimeters

High-precision calorimeter simulation at current and future colliders imposes rapidly growing computational demands, motivating the development of machine-learning surrogates for traditional Monte Carlo tools such as Geant4. Flow matching and diffusion-based generative models have become leading approaches for high-dimensional fast simulation because of their sample quality, but typically require ${\cal O}(100)$ function evaluations at inference and often rely on auxiliary networks to constrain global observables, compromising streamlined end-to-end generation. We introduce a unified framework that improves the balance between speed, shower quality, and physics fidelity. The method combines: (i) an average velocity field integrator that enables sampling in one or a few evaluations; (ii) a learned generative prior in shower space, constructed from data rather than random noise; and (iii) physics-guided loss terms that impose inductive biases on key observables during training. These elements are training time regularizers, preserving end-to-end inference with no additional cost. With only one or a few evaluation steps, the model achieves shower quality competitive with state-of-the-art flow and diffusion approaches, tested on several public high granularity calorimeter datasets. The results demonstrate inter-layer shower structure consistent with the underlying physics, providing a strong candidate for future fast simulation workflows.

Jiang, Cheng [Edinburgh U.]↗

A few-degree calorimeter for the future electron-ion collider

In this study, measuring the region 0.1 < Q 2 < 1.0 GeV 2 is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called Q 2 gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses this issue. The FDC uses SiPM-on-tile technology with tungsten absorber and covers the range of -4.6 < η < -3.6. It offers fine transverse and longitudinal granularity, along with excellent time resolution, enabling standalone electron tagging. Our design represents the first concrete solution to bridge the Q 2 gap at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leveraging staggered tessellation for enhanced spatial resolution in high-granularity calorimeters

Here we advance the concept of high-granularity calorimeters with staggered tessellations, underscoring the effectiveness of a design incorporating multifold staggering cycles based on hexagonal cells to enhance position resolution. Moreover, we introduce HEXPLIT, a sub-cell re-weighting algorithm tailored to harness staggered designs, resulting in additional performance improvements. By combining our proposed staggered design with HEXPLIT, we achieve an approximately twofold enhancement in position resolution for neutrons across a wide energy range, as compared to unstaggered designs. These findings hold the potential to elevate particle-flow performance across various forthcoming facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CaloScore v2: single-shot calorimeter shower simulation with diffusion models

Diffusion generative models are promising alternatives for fast surrogate models, producing high-fidelity physics simulations. However, the generation time often requires an expensive denoising process with hundreds of function evaluations, restricting the current applicability of these models in a realistic setting. In this work, we report updates on the CaloScorearchitecture, detailing the changes in the diffusion process, which produces higher quality samples, and the use of progressive distillation, resulting in a diffusion model capable of generating new samples with a single function evaluation. Here we demonstrate these improvements using the Calorimeter Simulation Challenge 2022 dataset.

47 OTHER INSTRUMENTATION↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of radiation damage on the light yield and uniformity of candidate plastic scintillator tiles for the CMS hadron calorimeter upgrade

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles and with tiles that had been irradiated in the CMS collision hall to a dose of 44 kGy. Results are presented for the tiles of different shapes in terms of the energy spectrum, efficiency as a function of the position at which each tile was hit, as well as light yield. All the tiles showed a light reduction of up to about 50%. The tiles with the shape currently used in the CMS detector did not see increased non-uniformity of light collection, while a significant disuniformity was observed for the tiles considered as alternatives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Denoising diffusion models with geometry adaptation for high fidelity calorimeter simulation

Simulation is crucial for all aspects of collider data analysis, but the available computing budget in the High Luminosity LHC era will be severely constrained. Generative machine learning models may act as surrogates to replace physics-based full simulation of particle detectors, and diffusion models have recently emerged as the state of the art for other generative tasks. Here, we introduce CaloDiffusion, a denoising diffusion model trained on the public CaloChallenge datasets to generate calorimeter showers. Our algorithm employs 3D cylindrical convolutions, which take advantage of symmetries of the underlying data representation. To handle irregular detector geometries, we augment the diffusion model with a new geometry latent mapping (GLaM) layer to learn forward and reverse transformations to a regular geometry that is suitable for cylindrical convolutions. The showers generated by our approach are nearly indistinguishable from the full simulation, as measured by several different metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning Techniques for Pile-Up Rejection in Cryogenic Calorimeters

CUORE Upgrade with Particle IDentification (CUPID) is a foreseen ton-scale array of Li 2 MoO 4 (LMO) cryogenic calorimeters with double readout of heat and light signals. Its scientific goal is to fully explore the inverted hierarchy of neutrino masses in the search for neutrinoless double beta decay of 100 Mo. Pile-up of standard double beta decay of the candidate isotope is a relevant background. We generate pile-up heat events via injection of Joule heater pulses with a programmable waveform generator in a small array of LMO crystals operated underground in the Laboratori Nazionali del Gran Sasso, Italy. This allows to label pile-up pulses and control both time difference and underlying amplitudes of individual heat pulses in the data. We present the performance of supervised learning classifiers on data and the attained pile-up rejection efficiency.

47 OTHER INSTRUMENTATION↗

Radio-Frequency Resonances and Damping in Metallic Magnetic Calorimeter Sensors

Metallic magnetic calorimeters (MMCs) are particle detectors that combine ultra-high energy resolution with a predictable and smooth response based on the physics of paramagnetism. For best energy resolution, MMCs are read out with dc SQUID preamplifiers. Since the ac Josephson effect also makes dc SQUIDs broadband RF sources in the 1–100 GHz range, the SQUID can potentially excite RF modes of the MMC sensor, with negative consequences. Further, the importance of this possibility is magnified in direct-coupled MMCs, where the MMC sensor is part of the SQUID loop to maximize performance. For these reasons, the RF behavior of MMC sensors must be investigated. In this report, we present the results of exploratory RF simulations of MMC sensor modes and damping, and we assess three approaches to damp the parallel-meander direct-coupled MMC without excessive noise increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Reconstruction in the Belle II Calorimeter Using Graph Neural Networks

We present the study of a fuzzy clustering algorithm for the Belle II electromagnetic calorimeter using Graph Neural Networks. We use a realistic detector simulation including simulated beam backgrounds and focus on the reconstruction of both isolated and overlapping photons. We find significant improvements of the energy resolution compared to the currently used reconstruction algorithm for both isolated and overlapping photons of more than 30% for photons with energies E γ < 0.5 GeV and high levels of beam backgrounds. Overall, the GNN reconstruction improves the resolution and reduces the tails of the reconstructed energy distribution and therefore is a promising option for the upcoming high luminosity running of Belle II.

Calorimeter↗

An automated QC station for the calibration of the Mu2e calorimeter readout units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. Here, in this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calomplification — the power of generative calorimeter models

Motivated by the high computational costs of classical simulations, machine-learned generative models can be extremely useful in particle physics and elsewhere. They become especially attractive when surrogate models can efficiently learn the underlying distribution, such that a generated sample outperforms a training sample of limited size. This kind of GANplification has been observed for simple Gaussian models. We show the same effect for a physics simulation, specifically photon showers in an electromagnetic calorimeter.

47 OTHER INSTRUMENTATION↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗