Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Volvo Penta 4.3 GL E15 Emissions and Durability Test

A new Volvo Penta carbureted 4.3 GL engine underwent emissions and dynamometer durability testing from break-in to expected end of life using an accelerated ICOMIA marine emissions cycle and E15 fuel. Only ethanol content was controlled. All aging used splash-blended E15 fuel. Exhaust emissions, exhaust gas temperature, torque, power, barometric pressure, air temperature, and fuel flow weremeasured at five intervals using site-blended E15 aging fuel and certification fuel (E0). The durability test cycle showed no noticeable impact on mechanical durability or engine power. Emissions performance degraded beyond the certification limit for this engine family, mostly occurring by 28% of expected life. Such degradation is inconsistent with prior experience. Comparisons showed that E15resulted in lower CO and HC, but increased NOX, as expected for non-feedback-controlled carbureted engines with increased oxygen in the fuel. Fuel consumption also increased with E15 compared with E0. Throughout testing, poor starting characteristics were exhibited on E15 fuel for hot re-start and cold-start. Cranking time to start and smooth idle was roughly doubled compared with typical E0operation. The carburetor was factory-set for lean operation to ensure emissions compliance. Test protocols did not include carburetor adjustment to account for increased oxygen in the E15 fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BTMS Testing Section

Cell testing is an important part of understanding the performance and life capabilities of stateof- the art energy storage technologies, particularly with respect to the distinct technical and functional requirements posed by the BTMS program. The baseline requirements for BTMS are loosely defined as a 1MWh BTMS system supporting six 350kW DC fast charging stations with no load profile defined. In order to test energy storage components and systems against these requirements, test procedures must be created that begin to address fundamental questions concerning the balance between cell performance and lifetime to minimize BTMS station cost and maximize station life. System usage scenarios are concurrently being developed with testing of baseline cells intended to illustrate their capabilities relative to a broad set of initial system assumptions. The results from these early performance tests and aging procedures will produce both slow and accelerated cycle-life aging information through a mix of empirical observations and modeling.

25 ENERGY STORAGE↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Status Report on Improved Understanding of Creep‐fatigue Damage in Advanced Materials

This report provides an update on the materials performance criteria and methodology relevant to liquid metal reactors (LMRs), in particular, sodium cooled fast reactors. The report is the first deliverable (Level 3) in FY11 (M3A11AN04030303) under the work package A-11AN040303 “Materials Performance Criteria and Methodology” as part of Advanced Structural Materials Program for the Advanced Reactor Concepts. The overall objective of the Advanced Materials Performance Criteria and Methodology project is to evaluate the key requirements for the ASME Code qualification and the Nuclear Regulatory Commission (NRC) approval of advanced structural materials in support of the design and licensing of the liquid metal fast reactors. Advanced materials are a critical element in the development of fast reactor technologies. Enhanced materials performance not only improves safety margins and provides design flexibility but also is essential for the economics of future advanced fast reactors. Qualification and licensing of advanced materials are prominent needs for the development and implementation of advanced fast reactor technologies. Nuclear structural component designs in the U.S. comply with the ASME Boiler and Pressure Vessel (B&PV) Code Section III (Rules for Construction of Nuclear Facility Components) and the NRC grants licensing. As the LMR will operate at higher temperatures than the current light water reactors (LWRs), the design of elevated-temperature components must comply with ASME Section III Subsection NH (Class 1 Components in Elevated Temperature Service). A number of technical issues relevant to materials performance criteria and high temperature design methodology in the LMR were identified and presented in earlier reports [Natesan et al. 2008, 2009]. A viable approach to resolve these issues and the R&D priority were also recommended. The development of mechanistically based creep-fatigue interaction models for life prediction and reliable data extrapolation was chosen to be the central focus in near-term efforts. Our current efforts focus on the creep-fatigue damage issue in high-strength ferritic-martensitic steels for two primary reasons. First, the current ASME design rule of bilinear damage summation puts severe limits of fatigue and creep loads for mod.9Cr-1Mo (G91) ferritic-martensitic steel, the lead structural material for fast reactors; secondly, the ferritic-martensitic steels behave fundamentally differently from austenitic stainless steels, for which the current ASME creep-fatigue design rules were developed. The unique deformation and damage characteristics in G91 steel, e.g. cyclic softening, degradation of creep and rupture strength during cyclic service, demands a new creep-fatigue design procedure that explicitly accounts for the material’s unique creep-fatigue behavior. To support the development of predictive models and to resolve the over-conservative issue with the ASME design rule for G91 steel, we recovered stress relaxation data from thirteen creep-fatigue tests conducted at Oak Ridge National Laboratory in late 1980s and early 1990s, and conducted extensive data analysis. Based on this limited database and available literature data, we have developed a Cyclic Softening Model and a Stress Relaxation Model specifically applied to G91 steel. The Cyclic Softening Model incorporates strain hardening and creep deformation, and predicts the cyclic stress variation as a function of cycle number during creep-fatigue loading. The Stress Relaxation Model predicts the stress relaxation curve during the hold time of cyclic loading, based on the creep properties of the material. By incorporating the newly developed Cyclic Softening Model and Stress Relaxation Model with the Bilinear Damage Model, we have evaluated the creep-fatigue damage in G91 steel using experimental data without any safety margins. The analysis provided a more realistic assessment of creep-fatigue damage and identified critical factors that need to be considered in future advanced models. We have found that due to the significant cyclic softening in G91 steel, the unit creep damage in each cycle decreased continuously with increasing number of cycles. This continuous change in creep damage with cycling has significant implication in the evaluation of the total creep-fatigue damage. The total creep damage can be one order of magnitude lower when the unit creep damage at half-life was used in the evaluation in comparison with the calculations using the unit creep damage at cycle 10. An important conclusion is the accurate assessment of the creep-fatigue damage in G91 steel must consider the cycling history. Future work will refine the Cyclic Softening Model and Stress Relaxation Model and integrate these two models with the Damage Rate Model for life prediction under creep-fatigue loading. An accelerated creep-fatigue testing methodology is proposed for the design of model-oriented experiments to guide and validate model development. Key material parameters in the model will be determined by creep and fatigue data, obtained under symmetric continuous cycling (fast-fast and slow-slow) and asymmetric cycling (slow-fast and fast-slow) which often lead to accelerated creep-fatigue damage. The established model, based on creep and fatigue properties, will then be used to predict the life under creep-fatigue loading with hold-time in either tension or compression or combined tension and compression. With the success of this mechanistically based life prediction model for G91 steel, the model will be extended to advanced ferritic-martensitic steels, such as NF616.

Li, Meimei↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Robustness of Asymptotic Optimal Accelerated Test Plans to Small-Sample Settings

Accelerated testing is a form of testing commonly employed in industry, especially at Sandia National Laboratories, in order to extract information about product lifetime behavior that cannot be acquired under normal operating conditions due to the extensive durations of the intended life- times. As of the writing of this report, there is no known guideline for the design of accelerated tests at the laboratories and yet there is an entire field in the statistical literature on the optimal design of accelerated tests covering a wide range of limitations and constraints available for reference. A potential roadblock to incorporating this knowledge is the common difficulty at Sandia of having severely limited data available for such testing. Nearly all of the methodology presented in the statistical literature is based on asymptotic or large-sample theory and so may not be appropriate for the testing conditions present at Sandia. This report investigates optimal accelerated test plans derived based on small-sample or exact methodology for both a basic test setting as well as a more realistic setting and compares the resulting test plans to those derived based on the large- sample methodology from the literature. It is shown that the large-sample test plans are actually quite robust to the presence of limited data and are generally more flexible than the small-sample test plans.

36 MATERIALS SCIENCE↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Photometric Testing, Laboratory Teardowns, and Accelerated Lifetime Testing of OLED Luminaires (CALiPER Report 24, Supplemented)

OLED luminaires are fairly new to the lighting market. This testing of commercially-available products uses independent photometric testing to evaluate color, electrical, and photometric performance, and has been supplemented in 2017 with two additional OLED luminaires. The report also includes teardown testing and accelerated lifetime testing to help identify areas of improved energy performance, and potential failure points, respectively.

42 ENGINEERING↗

Machine-Learning Assisted Identification of Battery Life Models

Predictive battery life models are commonly utilized to extrapolate degradation trends observed during accelerated aging tests for simulation of degradation in real-world applications. Thus, fitting accelerated aging data as accurately as possible and with low uncertainty is crucial for making believable projections of battery lifetime, but it is challenging to identify algebraic expressions that accurately fit multivariate degradation trends. A review of models published in literature reveal some common expressions for fitting calendar aging data, which is only dependent on temperature and state-of-charge, but no consistency across many models for fitting cycle aging data, indicating the need for a statistically rigorous data driven approach for developing empirical models. This talk will describe a machine-learning assisted method for identification of predictive battery life models utilizing bilevel optimization and symbolic regression. Bilevel optimization with cross-validation is used to statistically determine cell- and stress-dependent model parameters, while symbolic regression identifies both linear and multiplicative candidate expressions to predict stress-dependent degradation rates by selecting low-order subsets of features from a generated feature library. Because model expressions are identified empirically, it is crucial to ensure resulting models behave according to physical expectations, so the stability of models for interpolation or extrapolation is interrogated qualitatively through simulation and quantitatively through cross-validation and uncertainty quantification via bootstrap resampling. This model identification approach substantially improves upon models identified purely using expert judgement in terms of both accuracy and uncertainty. Model simulation and validation is then conducted by deriving a state-equation form of the predictive model, enabling simulation of battery aging under dynamic stresses. This enables validation of the predictive battery model on lab-based tests with varying conditions or on drive-cycle or application-cycle testing protocols. Parameter uncertainty can be carried forward into model simulation, giving lifetime estimates and confidence windows for cell- or system-level lifetime. The financial impact of battery model uncertainty can be estimated by incorporating uncertainty into a technoeconomic model.

battery↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Marrying Quality Assurance with Design Engineering - A Winning Partnership! But, a Cultural Divide

Investors would like to be confident that a PV plant will work as promised before investing large sums of money. Data showing that PV modules can withstand thousands of hours of accelerated testing are a comfort, but are not sufficient to characterize the economic useful life (EUL) of the whole PV system. An inability to be confident of every aspect of the system can motivate less favorable contract terms. In the end, a winning partnership is obtained when a carefully engineered, durable design is married with a robust quality management system and the marriage is extended across all parts of the value chain. However, this marriage is challenging because of the conventional cultural divide between design engineers and quality management specialists. International standards are being developed to facilitate this partnership and include technology-specific requirements in the quality management systems used for component manufacture and system design, construction and operation.

14 SOLAR ENERGY↗

Reliability Assessment of Solid-State Circuit Breakers (CRADA CRD-21-21469, Project 4 Final Report)

Growth in power requirements and the complexity of emerging distribution systems are creating the need for new solid-state products for many applications. The qualification requirements, testing standards and life-cycle management practices of solid-state devices used in protection applications is not established. The project will leverage newly developed accelerated testing capabilities design specifically for protection applications to generate large data sets that will enable advanced digital techniques for data analysis and embedded health monitoring.

14 SOLAR ENERGY↗

Extreme Fast Charging: Effect of Positive Electrode Material on Crosstalk

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. We tested cells containing five positive electrode chemistries, LFP (olivine structure), LMO (spinel), LCO (layered), NMC811 (layered) and NCA (layered), using fast-charging protocols. After testing, the negative electrodes from cells containing positive electrodes crystallizing with a layered structure were found to have more lithium deposited on their surfaces. Further, those crystallizing with a layered structure also tended to have a larger increase in impedance than those crystallizing with a spinel or olivine structure. Characterization of the negative electrodes by X-ray photoelectron spectroscopy showed that using the concentrations of LiF and Li x PO y F z as metrics, the concentration of LiF in the SEI from the cell with different positive electrodes is LFP > LMO > LCO ~ NMC811 > NCA; and for Li x PO y F z , the order is LMO > LFP > NCA > NMC811 > LCO. Clearly, the positive-electrode material was influencing the amounts of these materials formed.

25 ENERGY STORAGE↗

Corrosion Fatigue Life Evaluation of 17-4PH in Support of Water Filled Turbine Hubs

High cycle corrosion fatigue (HCCF) life S-N tests were conducted on wrought 17-4PH in various water environments under accelerated testing conditions. For tests conducted in aerated Columbia River water and in aerated ASTM Type IV water, at ~10 6 cycles, the HCCF stress amplitude was ~70% of the value in air. For deaerated water, the value was ~80%. These values are consist with the small amount of literature data on HCCF life of 17-4PH in water environments. The measured fatigue life both in air and water are much better than the ASME trend curve of high cycle fatigue life of moderate and high strength steels. Measured values were also much better than found in a hydropower-relevant study in the literature on cast 17-4PH. The effect of Amersite 61W on HCCF life was evaluated and found to cause very low times to specimen failure compared to all other water environments.

13 HYDRO ENERGY↗

Comparison of Battery Life Across Real-World Automotive Drive-Cycles (Presentation)

Laboratories run around-the-clock aging tests to try to understand as quickly as possible how long new Li-ion battery designs will last under certain duty cycles. These tests may include factors such as duty cycles, climate, battery power profiles, and battery stress statistics. Such tests are generally accelerated and do not consider possible dwell time at high temperatures and states-of-charge.Battery life-predictive models provide guidance as to how long Li-ion batteries may last under real-world electric-drive vehicle applications. Worst-case aging scenarios are extracted from hundreds of real-world duty cycles developed from vehicle travel surveys. Vehicles examined included PHEV10 and PHEV40 EDVs under fixed (28 degrees C), limited cooling (forced ambient temperature), andaggressive cooling (20 degrees C chilled liquid) scenarios using either nightly charging or opportunity charging. The results show that battery life expectancy is 7.8 - 13.2 years for the PHEV10 using a nightly charge in Phoenix, AZ (hot climate), and that the 'aggressive' cooling scenario can extend battery life by 1-3 years, while the 'limited' cooling scenario shortens battery life by 1-2years. Frequent (opportunity) charging can reduce battery life by 1 year for the PHEV10, while frequent charging can extend battery life by one-half year.

25 ENERGY STORAGE↗

Equivalent radiation damage in zirconium irradiated in various reactors - 2016-0101

The physical properties and in-reactor performance of core components made from zirconium alloys are a function of the radiation-induced atomic displacements that occur during service. The vacancy and interstitial point defects and their clusters created by the atomic displacements modify the microstructure, and therefore physical properties such as strength and ductility, by forming dislocation loops. The rate of production of point defects also affects time-dependent properties such as creep and diffusion (mass transport). To simulate the effect of irradiation on core components, researchers have used materials test reactors for many years to irradiate and test materials. Such reactor tests can target an accumulated displacement damage dose to simulate the state of a material at a given stage in reactor life but at an accelerated rate. Each nuclear reactor has a specific neutron energy spectrum that also depends on the in-reactor location. Therefore, to use test reactor data to determine the effect of radiation damage on power reactor materials, one must convert the accumulated dose into a unit that is common in its effect on the material properties. For many property changes in nuclear reactor cores, this unit is displacements per atom. This paper compares the damage production for zirconium irradiated under differing neutron energy spectra in various power and test reactors. The damage rates as a function of different measures of neutron flux were used to relate atomic displacements in various materials test reactors to CANDU and light-water reactor conditions. (authors)

36 MATERIALS SCIENCE↗

Correlation of Qualification and Accelerated Testing with Field Degradation

Qualification testing of solar photovoltaic (PV) modules per IEC 61215 standard encompasses a set of well-defined accelerated stress tests (irradiation, environmental, mechanical and electrical) with strict pass/fail criteria based on functionality/performance, electrical and mechanical safety, and visual requirements. The qualification testing does not identify all the possible reliability failures or durability issues witnessed in the actual field. However, it does identify the major/catastrophic design quality issues (infant mortality), which could occur early in a module’s field life. Unfortunately, in the industry, there is no consensus-based standard or protocol available to validate manufacturers’ warranty period claims based on the end-of-life wear-out failure mechanisms. Being able to predict the field degradation rates and lifetime using mode-specific accelerated tests on moderately field-aged modules, for example 10 years, for certain commonly occurring degradation modes would be a powerful contribution to all the stakeholders of the PV industry. There is a need to formulate guidelines to find the correlation of accelerated testing with field degradation for individual degradation modes observed in the field. Potential approaches to fulfill this need were experimented in this project and are presented in this report. Two of the most commonly seen degradation modes – encapsulant browning and solder bond thermomechanical fatigue – are addressed in this report through presenting the accelerated testing methods and physical modelling approaches. Two accelerated test methods (UV and thermal cycling) were designed to induce the wear-out mechanisms in the modules and not infant mortality failures. To focus on the wear-out failure modes, the tests were performed on field-aged modules, instead of fresh modules, with known degradation rates and degradation modes. The degradation rates were measured based on the degradation rates of individual cell parameters (short-circuit current, I sc and series resistance, R s ) instead of the degradation rate of maximum power (P max ) which cannot be used to study any specific/limited degradation mode as the P max degradation could be caused by many different degradation modes. The key characteristic parameter considered for encapsulant discoloration and solder bond degradation is I sc and R s , respectively. The developed physical models/equations relating the testing degradation data and field weather data were utilized to determine the acceleration factor (AF) and to predict the degradation rate for a specific degradation mode of PV modules installed in two different climates, Arizona (hot) and New York (cold). The predicted degradation rates for encapsulant browning and solder bond degradation have also been validated against the actual measured field degradation rates. UV testing cost reduction: To determine acceleration factor, single UV chamber was used for accelerated UV testing at three different temperatures simultaneously, instead of three chambers for three temperatures (or one chamber sequentially which is an extremely time-consuming approach). A passive heating approach was successfully used to achieve and maintain multiple temperatures in the accelerated UV chamber. Foam insulation boards of varying thicknesses were utilized to obtain three different temperatures for UV testing. However, these foam materials tend to disintegrate in the presence of moisture. To alleviate this problem, silicone heating blankets with temperature controls and humidifier can be used if the UV testing is to be performed under hot-humid conditions instead of conventional hot-dry conditions. Thermal cycling testing cost reduction: Single thermal cycling chamber was used for accelerated thermal cycling testing at three different upper temperatures simultaneously, instead of three chambers for three upper temperatures (or one chamber sequentially which is an extremely time-consuming approach). An active heating approach based on silicone heating blankets was successfully used to achieve and maintain multiple upper temperatures in the accelerated thermal cycling chamber. Such blankets provide stable temperature control and thereby more reliable and repeatable for replicate experiments.

14 SOLAR ENERGY↗

Selected Test Results from the Encell Technology Nickel Iron Battery

The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

25 ENERGY STORAGE↗