Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Interpreting scattered neutron spectra on omega cryogenic implosions with measured backgrounds and higher-order scattering

Measurements of the areal density (⁠ρR⁠) of inertially confined implosions are critical to evaluate their performance. On OMEGA, ρR is inferred from measurements of the scattered neutron spectrum via neutron-time-of-flight (nTOF) and magnetic recoil spectrometer detectors. The nTOF measurements, in particular, have the ability to measure a wide range of neutron energies and thus scattering angles, with high precision. However, the neutrons that are backscattered into the detector must transit through the entire dense fuel assembly, and as a result are subject to rescattering effects, which have been heretofore neglected in the interpretation of OMEGA neutron spectra. At the backscatter edge, neglecting rescattering on OMEGA can lead to a ~10 to 20% reduction of the apparent areal density and therefore must be included in the analysis. The low ρR s on OMEGA also mean that backgrounds from non-target physics effects, such as scattering in the target chamber or slow scintillator decays, can significantly alter the measured signal. Here, we discuss how the Monte Carlo neutron spectrum postprocessor IRIS is used to include second-order scattering effects in the interpretation of the scattered neutron spectrum in OMEGA implosion experiments, and how dedicated implosion experiments are used to measure nTOF backgrounds in order to infer backscattered areal densities on OMEGA.

Deuterium↗

Hybrid MEMS-CMOS ion traps for NISQ computing

Surging interest in engineering quantum computers has stimulated significant and focused research on technologies needed to make them manufacturable and scalable. In the ion trap realm this has led to a transition from bulk three-dimensional macro-scale traps to chip-based ion traps and included important demonstrations of passive and active electronics, waveguides, detectors, and other integrated components. At the same time as these technologies are being developed the system sizes are demanding more ions to run noisy intermediate scale quantum (NISQ) algorithms, growing from around ten ions today to potentially a hundred or more in the near future. To realize the size and features needed for this growth, the geometric and material design space of microfabricated ion traps must expand. In this paper we describe present limitations and the approaches needed to overcome them, including how geometric complexity drives the number of metal levels, why routing congestion affects the size and location of shunting capacitors, and how RF power dissipation can limit the size of the trap array. Finally, we also give recommendations for future research needed to accommodate the demands of NISQ scale ion traps that are integrated with additional technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of Short-Lived Isomers from Photofission as a Method of Active Interrogation for Special Nuclear Materials

Isomeric fission products, such as 134m Te (T 1/2 = 164 ns) and 136m Xe (T 1/2 = 2.95 μs), are proposed as a signature of special nuclear materials in active interrogation applications. To test this conjecture, monoenergetic 9, 11, and 13 MeV photons from the HIγS facility are used to induce fission of 235 U, 238 U, and 239 Pu targets. The de-excitation γ rays of the isomers are measured using time-gated spectroscopy with high-purity germanium detectors. The 134m Te and 136m Xe isomers are detected and identified by the energy and decay half-life of their characteristic γ-ray transitions. The ratio of yields for these two signature γ rays, corresponding to 134m Te/( 136m Xe + 136 I), is found to be strongly correlated with the identity of the fissioning nuclei. These results show that fission-product isomers may be used in active interrogation to detect and identify special nuclear materials, even providing information on the isotopic enrichment. In conclusion, the feasibility of an active interrogation scenario using a bremsstrahlung beam is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Clustering of electromagnetic showers and particle interactions with graph neural networks in liquid argon time projection chambers

Liquid argon time projection chambers (LArTPCs) are a class of detectors that produce high resolution images of charged particles within their sensitive volume. In these images, the clustering of distinct particles into superstructures is of central importance to the current and future neutrino physics program. Electromagnetic (EM) activity typically exhibits spatially detached fragments of varying morphology and orientation that are challenging to efficiently assemble using traditional algorithms. Similarly, particles that are spatially removed from each other in the detector may originate from a common interaction. Graph neural networks (GNNs) were developed in recent years to find correlations between objects embedded in an arbitrary space. The graph particle aggregator (GrapPA) first leverages GNNs to predict the adjacency matrix of EM shower fragments and to identify the origin of showers, i.e., primary fragments. On the PILArNet public LArTPC simulation dataset, the algorithm achieves a shower clustering accuracy characterized by a mean purity of 99.4%, a mean efficiency of 99.6% and a primary identification accuracy of 99.8%. It yields a relative shower energy uncertainty of (4.1 + 1.4 / $\sqrt{\text{E(GeV)})}$% and a shower direction uncertainty of (2.1/ $\sqrt{\text{E(GeV)})}$°. Finally, the optimized algorithm is then applied to the related task of clustering particle instances into interactions and yields a mean purity of 99.8% and a mean efficiency of 99.5% for an interaction density of $\mathcal{O}(1)$ m –3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CatMass : software for calculating optimal sample masses for X-ray absorption spectroscopy experiments involving complex sample compositions

This paper presents software for calculating the optimal mass of samples with complex compositions ( e.g. supported metal catalysts) for X-ray absorption spectroscopy (XAS) and scattering measurements. The ability to calculate the sample mass and other relevant parameters needed for an XAS measurement allows experimentalists to be better prepared in terms of detector selection, energy range of scan and overall time needed to complete the measurement, thus increasing efficiency. CatMass builds on existing sample mass calculators allowing users to determine the optimum sample preparation, collection geometry, usable energy range for a scan and approximate edge step of the absorption event. Visualization tools present the absorption calculation results in a format familiar to XAS experimentalists, with the added ability to save calculations and plots for future reference or recalculation. CatMass is a program broadly applicable in catalysis and is helpful for users with complex samples due to composition/stoichiometry or multiple competing elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of ML FPGA Filter for Particle Identification and Tracking in Real Time

Real-time data processing is a frontier field in experimental particle physics. Machine Learning methods are widely used and have proven to be very powerful in particle physics. The growing computational power of modern FPGA boards allows us to add more sophisticated algorithms for real time data processing. Many tasks could be solved using modern Machine Learning (ML) algorithms which are naturally suited for FPGA architectures. The FPGA-based machine learning algorithm provides an extremely low, sub-microsecond, latency decision and makes information-rich data sets for event selection. We report work has started to evaluate an FPGA based Machine Learning (ML) algorithm for a real-time particle identification and tracking with Transition Radiation Detector (TRD) and e/m calorimeter. The first target is the GlueX experiment, with a plan to build a TRD based on GEM technology. GlueX trigger latency is 3.3 μs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects of Neutrino Cross Section Measurements Using the NuMI off axis at ICARUS [Poster]

ICARUS, a Liquid Argon Time Projection Chamber, will serve as the Far Detector of the short-baseline neutrino program using the Booster beamline at Fermilab. It is 103 mrad off-axis of the NuMI beamline. Prospects for cross-section measurements and the status of the trigger system using the PMT system to collect electron and muon neutrinos from NuMI will be shown. Accurate neutrino cross-section measurements on argon are required for precise measurements of neutrino oscillation physics such as CP- violation and the ordering of the neutrino masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of neutral current single π 0 production on argon with the MicroBooNE detector

We report the first measurement of π 0 production in neutral current (NC) interactions on argon with average neutrino energy of ≲1 GeV. We use data from the MicroBooNE detector’s 85-tonne active volume liquid argon time projection chamber situated in Fermilab’s Booster Neutrino Beam and exposed to 5.89 × 10 20 protons on target for this measurement. Measurements of NC π 0 events are reported for two exclusive event topologies without charged pions. Those include a topology with two photons from the decay of the π 0 and one proton and a topology with two photons and zero protons. Flux-averaged cross-sections for each exclusive topology and for their semi-inclusive combination are extracted (efficiency-correcting for two-plus proton final states), and the results are compared to predictions from the GENIE, NEUT, and NUWRO neutrino event generators. We measure cross sections of 1.243 ± 0.185 (syst) ±0.076 (stat), 0.444 ± 0.098 ± 0.047, and 0.624 ± 0.131 ± 0.075 [10 -38 cm 2 /Ar] for the semi-inclusive NCπ 0 , exclusive NCπ 0 +1p, and exclusive NCπ 0 +0p processes, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Specification of EBR-II Gamma Scan Data from the Precision Gamma Scanner

The gamma scan data stored in the FIPD was originally measured using the Precision Gamma Scanner (PGS) at the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). This system was originally manufactured in 1971 (when the facilities, now at INL, were operated by Argonne National Laboratory) and was upgraded on several occasions. It consists of a germanium gamma ray detector (the exact nature of which changed over time as technology improved), a variable-slit collimator that blocks the view of gamma emissions from all but the selected area of the target, and a computer-controlled system for translating a sample past the slit and logging the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shower Reconstruction for Cross-Section Measurements with Photon(s) in the Final State at SBND

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber operating in the Booster Neutrino Beam at Fermilab as part of the Short-Baseline Neutrino Program. Precise reconstruction of electromagnetic showers from photons and electrons is essential for searches for neutrino oscillations, cross-section measurements, and rare-process studies in liquid argon. In this poster, we present a unified set of SBND analyses enabled by the SPINE (Scalable Particle Imaging with Neural Embeddings) end-to-end machine-learning–based reconstruction framework, highlighting charged-current neutral pion (CC π⁰) production and neutral-current (NC) Δ radiative decay as complementary physics cases. Charged-current π⁰ interactions provide a high-statistics benchmark for validating photon reconstruction, constraining the electromagnetic energy scale, and modeling backgrounds to other cross-section measurements and BSM searches with one or more photons in the final state. We summarize progress toward the ongoing development of a CC π⁰ selection in SBND and, report on the current status of a search for NC resonant Δ production followed by radiative decay (Δ→Nγ) in SBND. This rare process, previously investigated in MicroBooNE, provides a stringent test of photon-only final-state reconstruction and is of interest in the context of the MiniBooNE low-energy excess. Together, these analyses demonstrate how modern machine-learning–based shower reconstruction enables a diverse and scalable physics program at SBND.

Chung, Seokju [Nevis Labs, Columbia U.]↗

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

Monte Carlo Study of Imaging Plate Response to Laser-Driven Aluminum Ion Beams

We measured the response of BAS-TR imaging plate (IP) to energetic aluminum ions up to 222 MeV, and compared it with predictions from a Monte Carlo simulation code using two different IP response models. Energetic aluminum ions were produced with an intense laser pulse, and the response was evaluated from cross-calibration between CR-39 track detector and IP energy spectrometer. For the first time, we obtained the response function of the BAS-TR IP for aluminum ions with a kinetic energy as high as 222 MeV. On close examination of the two IP response models, we confirm that the exponential model fits our experimental data better. Moreover, we find that the IP sensitivity in the exponential model is nearly constant in this energy range, suggesting that the response function can be determined even with little experimental data.

Won, Junho↗

Gamma Ray Detection In Liquid Argon Time Projection Chambers

Gamma rays are photons in excess of 100 keV of energy and can be produced by a variety of mechanisms like radioactive decay and inelastic neutrino-argon interactions. A reconstruc- tion of Compton scattering gamma rays was developed for use in liquid argon time projection chambers. This reconstruction was tested with detectors developed to demonstrate the ca- pabilities of Deep Underground Neutrino Experiment (DUNE) Near Detector Liquid Argon target (ND LAr). In October 2024, a radioactive fluorine-18 source was placed next to the Full Scale Demonstrator. The data obtained was used to test this reconstruction algorithm. It was able to determine the direction of the photons with an error of less than 10 percent. In addition to this work, there has been significant work on designing a liquid argon based Positron Emission Tomography (PET) scanner. PET scanners detect gamma rays emitted by a tracer chemical to help screen for diseases like cancer. In addition to the applications to medical imaging, this thesis briefly explores the applications of this reconstruction to de-excitation photons produced in interactions between neutrinos and argon nuclei. These applications could improve studies focusing on neutrinos originating from accelerators and supernovae.

Murphy, Thomas [Syracuse U.]↗

Homomorphic data compression for real time photon correlation analysis

The construction of highly coherent X-ray sources, combined with next-generation detectors that are larger and faster, has enabled new research opportunities across the scientific landscape. Among the techniques that benefit most from these advancements is X-ray photon correlation spectroscopy (XPCS), where faster acquisition unlocks the ability to study faster dynamics within samples. However, faster acquisition on larger detectors also introduces unprecedented challenges for online data processing and offline data storage. Such challenges are particularly prominent for XPCS, where real time analyses require simultaneous calculation of all the previously acquired data in the time series. We present a homomorphic compression scheme to effectively reduce the computational time and memory space required for XPCS analysis. Leveraging similarities in the mathematical expression between a matrix-based compression algorithm and the correlation calculation, our approach allows direct operation on the compressed data without their decompression. The offline compression scheme extends storage capacity by a factor of 40 while preserving key features in the lossy compressed data. Meanwhile, the online compression scheme reduces the computational time to below 1 ms, enabling real time calculation of the correlation functions at kHz framerate. Our demonstration of a homomorphic compression of scientific data provides an effective solution to the big data challenge at coherent light sources. Beyond the example shown in this work, the framework can be extended to facilitate real-time operations directly on a compressed data stream for other techniques.

36 MATERIALS SCIENCE↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗