Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Measurements by the plasma diagnostics package on STS-3

A comprehensive set of measurements about the orbiter environment are provided by the plasma diagnostics package (PDP). Ion and electron particle densities, energies, and spatial distribution functions; ion mass for identification of particular molecular ion species; and magnetic fields, electric fields and electromagnetic waves over a broad frequency range are studied. Shuttle environmental measurements will be made both on the pallet and, by use of the remote manipulator system (RMS), the PDP will be maneuvered in and external to the bay area to continue environmental measurements and to carry on a joint plasma experiment with the Utah State University fast-pulsed electron generator. Results of orbiter environment EMI measurements and S-band field strengths as well as preliminary results from wake search operations indicating wake boundary identifiers are reported.

Shawhan, S. D.↗

NOAA-9 Earth Radiation Budget Experiment (ERBE) scanner offsets determination

The Earth Radiation Budget Experiment (ERBE) instruments are designed to measure the components of the radiative exchange between the Sun, Earth and space. ERBE is comprised of three spacecraft, each carrying a nearly identical set of radiometers: a three-channel narrow-field-of-view scanner, a two-channel wide-field-of-view (limb-to-limb) non-scanning radiometer, a two-channel medium field-of view (1000 km) non-scanning radiometer, and a solar monitor. Ground testing showed the scanners to be susceptible to self-generated and externally generated electromagnetic noise. This paper describes the pre-launch corrective measures taken and the post-launch corrections to the NOAA-9 scanner data. The NOAA-9 scanner has met the mission objectives in accuracy and precision, in part because of the pre-launch reductions of and post-launch data corrections for the electromagnetic noise.

Avis, Lee M.↗

Proton emission in ultraperipheral Pb-Pb collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 5.02 TeV

The first measurements of proton emission accompanied by neutron emission in the electromagnetic dissociation (EMD) of 208 Pb nuclei in the ALICE experiment at the Large Hadron Collider are presented. The EMD protons and neutrons emitted at very forward rapidities are detected by the proton and neutron zero degree calorimeters of the ALICE experiment. The emission cross sections of zero, one, two, and three protons accompanied by at least one neutron were measured in ultraperipheral 208 Pb − 208 Pb collisions at a center-of-mass energy per nucleon pair $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 5.02TeV. The 0p and 3p cross sections are described by the RELDIS model within their measurement uncertainties, while the 1p and 2p cross sections are underestimated by the model by 17–25%. According to this model, these 0p, 1p, 2p, and 3p cross sections are associated, respectively, with the production of various isotopes of Pb, Tl, Hg, and Au in the EMD of 208 Pb . The cross sections of the emission of a single proton accompanied by the emission of one, two, or three neutrons in EMD were also measured. The data are significantly overestimated by the RELDIS model, which predicts that the (1p,1n), (1p,2n), and (1p,3n) cross sections are very similar to the cross sections for the production of the thallium isotopes 206,205,204 Tl.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma Measurement Strategies for Solar Sailcraft

Solar sailcraft offer enabling capabilities for achieving future space physics mission objectives. These sailcraft will be the largest platforms that space physics missions will potentially use. The electromagnetic interaction of the sailcraft with the local environment is of keen interest. Plasma measurement strategies for a validation mission and for operational missions are discussed.

Wright, Kenneth H.↗

Quasi-one-dimensional modes in strip plates: Theory and experiment

Using acoustic resonance spectroscopy we measure the elastic resonances of a strip rectangular plate with all its ends free. The experimental setup consist of a vector network analyzer, a high-fidelity audio amplifier, and electromagnetic-acoustic transducers. The one-dimensional modes are identified from the measured spectra by comparing them with theoretical predictions of compressional and bending modes of the plate modeled as a beam. The agreement between theory and experiment is excellent.

97 MATHEMATICS AND COMPUTING↗

Measurements of the dielectric properties of simulated comet material as part of the KOSI 10 experiment

The dielectric constant epsilon of the snow-mineral used for the comet simulation in the German KOSI 10 experiment was measured in the radio frequency range from 2 to 4 GHz. The traditional microwave bridge method was used, but instead of using a waveguide that contains the sample material small lambda/4 antennas were used as sensors. A change in the dielectric properties indicates a change in density and/or composition, respectively. The method is presented as an analytical tool for measuring such density or composition changes during alteration snow-dust materials. The KOSI (determined from the German: Kometen Simulation) experiments, performed in the Space simulator of the DLR/Institut for Raumsimulation, during the last years revealed many processes that presumably take place on comets. So far, modifications of the internal structure could be identified only during the post-experiment inspection via hardness tests. It was the aim of the KOSI 10 and KOSI 10a experiments to emphasize on a synoptic detection of events like particle emission or crust formation. The composition of the KOSI 10 sample material was an ice-mineral mixture with about 10 percent mineral (olivine) content. An excellent method to investigate the change of the density of the probe material during its exposure to the artificial sun in situ is to do it via the measurement of the dielectric constant. The traditional method to determine epsilon, by using a microwave-bridge to measure the transmission and the reflection factor of the sample material for electromagnetic waves in the radio frequency range, was modified, since the commonly used practice to fill the sample material into a waveguide was not compatible with the need for in situ measurements during the simulation experiment.

Ulamec, S.↗

Picosecond timing of microwave Cherenkov impulses from high-energy particle showers using dielectric-loaded waveguides

Here, we report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of ∼10 3 – 10 4 GeV were preshowered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid alumina (Al 2⁢ O 3 ) bars. In the 5–8 GHz 𝑇⁢𝐸 10 single-mode band determined by the presence of the dielectric in the waveguide, we observed band-limited microwave impulses with amplitude proportional to bunch energy. Signals in different waveguide elements measuring the same shower were used to estimate relative time differences with 2.3 ps precision. These measurements establish a basis for using arrays of alumina-loaded waveguide elements, with exceptional radiation hardness, as very high precision timing planes for high-energy physics detectors.

43 PARTICLE ACCELERATORS↗

A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat energy of various ignition sparks

This report describes a method developed at the Bureau of Standards for measuring the total energy liberated as heat in a spark gap by an ignition system. Since this heat energy is obtained from the electromagnetic energy stored in the windings of the magneto or coil, it is a measure of the effectiveness of the device as an electric generator. Part 2 gives the results of measurements in absolute units of the total heat supplied to a spark gap by ignition systems of different types operating at various speeds, under conditions substantially equivalent to those in the cylinder of a high-compression aviation engine.

Silsbee, F B↗

Hybrid sensor for metal grade measurement of a falling stream of solid waste particles

Highlights: Black-Right-Pointing-Pointer A new sensor system is developed for metal grade measurement of falling bottom ash particles. Black-Right-Pointing-Pointer The system is hybrid, consisting of an optical and an electromagnetic sensor. Black-Right-Pointing-Pointer Grade of ECS concentrated bottom ash in 1-6 mm sieve size accurately measured up to 143 p/s feed rate. Black-Right-Pointing-Pointer Accuracy reached was 2.4% with respect to manual analysis. Black-Right-Pointing-Pointer Measures for elimination of both stationary and stochastic errors are discussed. - Abstract: A hybrid sensor system for accurate detection of the metal grade of a stream of falling solid waste particles is investigated and experimentally verified. The system holds an infrared and an electromagnetic unit around a central tube and counts all the particles and only the metal particles, respectively. The count ratio together with the measured average particle mass ratio (k) of non-metal and metal particles is sufficient for calculation of grade. The performance of the system is accurately verified using synthetic mixtures of sand and metal particles. Towards an application a case study is performed using municipal solid waste incineration bottom ash in size fractions 1-6 mm, which presents a major challenge for nonferrous metal recovery. The particle count ratio was inherently accurate for particle feed rates up to 13 per second. The average value and spread of k for bottom ash was determined as 0.49 {+-} 0.07 and used to calculate grade within 2.4% from the manually analysed grade. At higher feed rates the sensors start missing particles which fall simultaneously through the central tube, but the hybrid system still counted highly repeatable. This allowed for implementation of a count correction ratio to eliminate the stationary error. In combination with averaging in measurement intervals for suppression of stochastic variations the hybrid system regained its accuracy for particle feed rates up to 143 per second. This performance and its special design, intended to render it insensitive to external interference and noise when applied in an eddy current separator, make the hybrid sensor suitable for applications such as quality control and sensor controlled separation.

42 ENGINEERING↗

Electromagnetic and Light Scattering by Nonspherical Particles XV: Celebrating 150 Years of Maxwell's Electromagnetics

The 15th Electromagnetic and Light Scattering Conference (ELS-XV) was held in Leipzig, Germany from 21 to 26 of June 2015. This conference built on the great success of the previous meetings held in Amsterdam (1995), Helsinki(1997) [2], New York City(1998) [3], Vigo (1999),Halifax (2000), Gainesville (2002), Bremen (2003), Salobreña (2005), St. Petersburg (2006), Bodrum (2007), Hatfield (2008), Helsinki (2010), Taormina (2011), and Lille as well as the workshops held in Bremen (1996,1998) and Moscow (1997). As usual, the main objective of this conference was to bring together scientists, engineers, and PhD students studying various aspects of electromagnetic scattering and to provide a relaxed atmosphere for in-depth discussion of theory, measurements, and applications. Furthermore, ELS-XV supported the United Nations "Year of Light" and celebrated the150th anniversary of Maxwell's electromagnetics. Maxwell's paper on "A Dynamical Theory of the Electromagnetic Field" was published in1865 and has widely been acknowledged as one of the supreme achievements in the history of science. The conference was attended by136 scientists from 22 countries. The scientific program included two plenary lectures, 16 invited reviews, 88 contributed oral talks, and 70 poster presentations. The program and the abstracts of conference presentations are available at the conference website http://www.els-xv-2015.net/home.html. Following the well-established ELS practice and with Elsevier's encouragement, we solicited full-size papers for a topical issue of the Journal of Quantitative Spectroscopy and Radiative Transfer (JQSRT). The result of this collective effort is now in the reader's hands. As always, every invited review and regular paper included in this topical issue has undergone the same rigorous peer review process as any other manuscript published in the JQSRT.

light scattering↗

SU-E-J-160: Comparing the Setup Accuracy of Non-Ionizing Patient Localization Systems with CBCT to Reduce Imaging Dose in Prone Breast Treatments

Purpose: CBCT is the current gold standard to verify prone breast patient setup. We investigated in a phantom if non-ionizing localization systems can replace ionizing localization systems for prone breast treatments. Methods: An anthropomorphic phantom was positioned on a prone breast board. Electromagnetic transponders were attached on the left chest surface. The CT images of the phantom were imported to the treatment planning system. The isocenter was set to the center of the transponders. The positions of the isocenter and transponders transferred to the transponder tracking system. The posterior phantom surface was contoured and exported to the optical surface tracking system. A CBCT was taken for the initial setup alignment on the treatment machine. Using the electromagnetic and optical localization systems, the deviation of the phantom setup from the original CT images was measured. This was compared with the difference between the original CT and kV-CBCT images. Results: For the electromagnetic localization system, the phantom position deviated from the original CT in 1.5 mm, 0.0 mm and 0.5 mm in the anterior-posterior (AP), superior-inferior (SI) and left-right (LR) directions. For the optical localization system, the phantom position deviated from the original CT in 2.0 mm, −2.0 mm and 0.1 mm in the AP, SI and LR directions. For the CBCT, the phantom position deviated from the original CT in 4.0 mm, 1.0 mm and −1.0 mm in the AP, SI and LR directions. The measured values from the non-ionizing localization systems differed from those with the CBCT less than 3.0 mm in all directions. Conclusions: This phantom study showed the feasibility of using a combination of non-ionizing localization systems to achieve a similar setup accuracy as CBCT for prone breast patients. This could potentially eliminate imaging dose. As a next step, we are expanding this study to actual patients. This work has been in part supported by Departmental Research Award RODEPT1-JS001, Department of Radiation Oncology, UC Davis Medical Center.

60 APPLIED LIFE SCIENCES↗

Representativeness and repeatability of microenvironmental personal and head exposures to radio-frequency electromagnetic fields

Highlights: • First time assessment of head exposure to RF-EMF in uncontrolled environments, in 15 microenvironments in Melbourne, Australia. • We show that our measurement protocol is repeatable over time. • We show that the paths selected in our protocol are representative for the larger areas in which they are defined. • Exposure to RF-EMF is higher in more dense urban areas than in less populated suburban areas in the outskirts of the city. The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r{sup 2} > 0.66 for two paths in the same area) and a high repeatability over time (r{sup 2} > 0.87 for repetitions of the same path). The median head exposure in the 900 MHz downlink band ranged between 0.06 V/m and 0.31 V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r{sup 2} < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89 V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05 V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

TH-CD-BRA-10: Towards Reference Dosimetry of MR-Linacs Using a Clinical Probe-Format Calorimeter

Purpose: To evaluate the influence of a 1.5 T magnetic field (B-field) on the response of a small-scale graphite calorimeter probe (GPC) developed for use as a novel clinical reference dosimeter. Characterization of the GPC was also assessed in a hybrid MRI-linac (MRL) clinical prototype by performing absolute dosimetry in multiple detector orientations. Methods: B-field influence was characterized using a variable-strength electromagnet system located 280 cm from the source of a clinical linac. The GPC was used to perform a total of 160 absolute dose measurements (6 MV, 920 MU/min) in a water phantom placed between the poles of the electromagnet. The magnitude of the B-field between the poles was varied in the range of 0 – 1.5 T. The relative response of the GPC was determined and compared to that of a thimble type ionization chamber (Exradin A1SL, Standard Imaging). Next, 65 dose measurements were performed using the GPC in a clinical MRL field (7 MV, 620 MU/min) to quantify the rotational dependence of the detector in the presence of a 1.5 T B-field. The GPC was rotated in steps of 90° inside a graphite phantom (SSD 140 cm, depth 2.5 cm) for two detector orientations (parallel and perpendicular to the B field). Results: Relative to the zero B-field condition, the A1SL chamber exhibited an average overresponse of +1.2 % ± 0.03 % at a B-field of 1.5 T, while the GPC under-responded on average by −0.5 % ± 0.9 %. For the MRL measurements, no significant differences were observed between the parallel and perpendicular orientations. In both cases, a rotational dependence of approximately ±1 % was measured. Conclusion: This work suggests that the B-field has minimal influence on the response of the GPC, making it a potentially attractive solution for clinical MRL reference dosimetry. This work has been supported in part by the CREATE Medical Physics Research Training Network NSERC grant RGPIN 432290, as well as NSERC grants RGPIN 298191 & 435608. JR is a scholar from The Terry Fox Foundation Strategic Training Initiative for Excellence in Radiation Research for the 21st Century (EIRR21).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible Magnetic Polymer Composite Substrate with Ba 1.5 Sr 1.5 Z Hexaferrite Particles of VHF/Low UHF Patch Antennas for UAVs and Medical Implant Devices

Our goal is to fabricate flexible magnetic polymer composites as antenna substrates for very high frequency (VHF)/low ultra high frequency (UHF) antennas for unmanned aerial vehicles (UAVs) and medical devices. Magnetodielectric materials, which have permeability (μ) similar to permittivity (ε), have attracted great attention, because they facilitate miniaturization of microwave devices while keeping or enhancing electromagnetic characteristics. Mechanically millled Ba 1.5 Sr 1.5 Co 2 Fe 24 O 41 (Ba 1.5 Sr 1.5 Z) hexaferrite particles were used to increase permeability in the interesting frequency band. The microwave properties of Ba 1.5 Sr 1.5 Z composites were predicted and measured. Hansen’s zero-order analysis of antenna bandwidth and electromagnetic field simulation showed that the hexaferrite-based flexible composite could enhance a bandwidth and achieve the miniaturization of antennas as well. The magnetic antenna substrates can be a good solution to integrate antennas into the UAVs whose dimensions are comparable to or larger than communication wavelength.

36 MATERIALS SCIENCE↗

Measuring Gravitation Using Polarization Spectroscopy

A proposed method of measuring gravitational acceleration would involve the application of polarization spectroscopy to an ultracold, vertically moving cloud of atoms (an atomic fountain). A related proposed method involving measurements of absorption of light pulses like those used in conventional atomic interferometry would yield an estimate of the number of atoms participating in the interferometric interaction. The basis of the first-mentioned proposed method is that the rotation of polarization of light is affected by the acceleration of atoms along the path of propagation of the light. The rotation of polarization is associated with a phase shift: When an atom moving in a laboratory reference interacts with an electromagnetic wave, the energy levels of the atom are Doppler-shifted, relative to where they would be if the atom were stationary. The Doppler shift gives rise to changes in the detuning of the light from the corresponding atomic transitions. This detuning, in turn, causes the electromagnetic wave to undergo a phase shift that can be measured by conventional means. One would infer the gravitational acceleration and/or the gradient of the gravitational acceleration from the phase measurements.

Matsko, Andrey↗

SERS Theory: The Chemical Effect of Rhodamine 6G Adsorption on Silver Surfaces on Its Raman Spectrum

The SERS spectra of small organic molecules can be very sensitive to the physisorption or chemisorption of the molecules onto metallic surfaces. However it is challenging to model the results, as typical SERS substrates have a broad distribution of possible surface sites, and the populations of these sites and the SERS enhancement factors associated with them are very difficult to determine, especially when electromagnetic hot spots dominate the observed spectra. However it is important to account for these effects if one is to make a quantitative interpretation of measured SERS spectra. Indeed, the influence of different sites is important to both the electromagnetic and chemical mechanisms in SERS, where the former mechanism is concerned with local field enhancement effects arising from plasmon excitation, while the latter arises from the effect of chemisorption induced charged transfer on the Raman intensities, as can be modeled using static limit Raman intensity calculations[1]. Extensive studies have been performed on simple organics like pyridine bound to gold and silver clusters, and it was found that both the chemical and electrodynamic enhancement factors associated with binding pyridine in various orientations result in noticeable changes in the SERS spectra compared to the gas phase spectrum of pyridine.[2] One of the most important benchmark molecules for SERS and TERS studies is Rhodamine 6G (R6G). This is a strongly fluorescent dye molecule in solution, but when adsorbed onto SERS substrates, its fluorescence is quenched, and the resulting SERS intensities are among the largest observed for any molecule. As a result R6G has played a crucial role in the development of single molecule SERS, and in the development of SERS substrates. [3, 4] Previously, the SERS spectrum of R6G has been modeled as if it were a gas phase molecule. Jensen and Schatz[5] incorporated resonant effects as well as vibronic effects and found that resonance excitation to the S1 excited state of R6G resulted in good agreement with spectra obtained from SERS experiments. In another study, intermolecular charge transfer was studied with R6G bound to a Ag2 cluster.[6] It is unclear if a cluster model as small as two silver atoms can accurately capture the surface effects of a nanoparticle with thousands of atoms. Recent single molecule, ultra high vacuum, tip enhanced Raman spectroscopy (SM-UHV-TERS) measurements for R6G[3] were moderately reproduced by gas phase resonance Raman calculations. Of particular importance in this work was the comparison of TERS spectra at room temperature with those at a low temperature of 10K. It was found that lowering the temperature led to both sharpening of the vibrational spectra, and shifts in the spectra (up to 20 cm-1 with some lines shifting red, some blue and some not at all), suggesting that the molecule transitions from a largely gas phase molecule at room temperature to being strongly chemisorbed at 10K. A potential energy distribution analysis performed by Chulhai and Jensen[3] showed that the modes that were shifted from the gas phase had vibrational activity associated with the ethylamine component of R6G, which is the likely moiety associated with Raman calculations. What remains unresolved concerning the SM-UHV-TERS studies of R6G is direct evidence that the chemical binding of R6G to a silver nanoparticle surfaces causes frequency shifts and/or intensity changes in the Raman scattering intensities of specific modes, especially those involving vibrations of the ethylamine moiety. The theoretical work described in this chapter directly addresses this issue by calculating Raman spectra for R6G interacting with a 20-atom silver cluster, and with a flat Ag(111) surface. Tetrahedral Ag20 is chosen for part of these studies as it provides a model nanoparticle structure that has a well-defined fragment of a (111) surface, as well as having edges and vertices that can be used to model coordinately unsaturated sites on a particle. In addition, Ag20 has been found to provide a reasonable reference structure for determining the chemical contribution to SERS enhancements.[1] Two different geometries of the Ag20/R6G system are considered in the present study, corresponding to two different binding configurations of R6G to a pristine Ag(111) surface. In addition, we study adsorption of R6G on a flat Ag(111) surface of using plane wave DFT calculations to determine optimized geometries and normal mode properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-51: Dose Response of Common Solid State Detectors in Homogeneous Transverse and Longitudinal Magnetic Fields

Purpose: Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is evaluated in varying transverse and longitudinal magnetic fields for eventual use in MR-Linac devices. Methods: A PTW 60003 and IBA PFD detector were modeled in the Monte Carlo code PENELOPE, incorporating a magnetic field which was varied in strength and oriented both transversely and longitudinally with respect to the incident photon beam. The detectors' long axis was in turn oriented either parallel or perpendicular to the photon beam. Dose to the active volume of each detector was scored, and its ratio to dose with zero magnetic field strength (dose response) was determined. Accuracy of the simulations was evaluated by measurements using both chambers taken at low field with a small electromagnet. Simulations were also performed in a water phantom to compare to the in air results. Results: Significant dose response was found in transverse field geometries, nearing 20% at 1.5T. The response is highly dependent on relative orientations to the magnetic field and photon beam, and on detector composition. Low field measurements confirm these results. In the presence of longitudinal magnetic fields, the detectors exhibit little dose response, reaching 0.5–1% at 1.5T regardless of detector orientation. Water tank simulations compared well to the in air simulations when not at the beam periphery, where in transverse magnetic fields only, the water tank simulations differed from the in air results. Conclusion: Transverse magnetic fields can cause large deviations in dose response, and are highly position orientation dependent. Comparatively, longitudinal magnetic fields exhibit little to no dose response in each detector as a function of magnetic field strength. Water tank simulations show longitudinal fields are generally easier to work with, but each detector must be evaluated separately.

07 ISOTOPE AND RADIATION SOURCES↗