Optimization and assessment of floating and floating-tracking PV systems integrated in on- and off-grid hybrid energy systems
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This case study was presented at the ICTP-IAEA VIRTUAL Course on Nuclear-Renewable Integrated Energy Systems: Phenomenology, Research and Development. It provides preliminary results on an analysis of hybridizing the two nuclear power plants owned by Xcel Energy and located in Minnesota. The analysis extends previous analyses that provided only price-taker results. Those assume adjusting the generation sold to the grid does not impact locational marginal electricity prices nor do they estimate impacts on the total net cost to serve the load. This presentation summarizes the new technique that was developed to both optimize the size and operations of the hybridized system and the resulting impacts on the grid when it is operated optimally.
This paper proposes a hierarchical coordinated control strategy for PV inverters to keep voltages in low-voltage (LV) distribution grids within specified limits. The top layer of the proposed architecture consists of the designed automatic voltage regulation (AVR) application, which has access to voltage measurements and grid parameters from the LV distribution grid, both current and historical. The AVR application solves a constrained optimization problem, which provides a set of local control set-points that bring the voltage across the grid within bounds. The middle layer consists of a local Volt/VAR controller, which is adjusted by the AVR app, while the bottom layer is the inner-loop controller of the PV inverter. The proposed method not only improves the voltage quality in the grid but also manages the reactive power outputs of PV inverters efficiently. Further, a digital twin of the cyber-physical system has also been employed that interacts with the control system to ensure its appropriate operation. The effectiveness of the proposed methodology is demonstrated on a representative low-voltage feeder located in Denmark.
Transmission constraints, increasing motivations to decarbonize, and concerns over peak electric vehicle (EV) load impacts on local grids have driven electric customers to consider behind-the-meter, hybrid power plant generation and storage at the distributed-grid level for EV charging. In this study, we develop capabilities to optimize hybrid power plant component capacities for EV charging. We then demonstrate these capabilities in a case study for Boulder, Colorado, using public EV charging data as well as wind and solar resource data. Our results show system designs that balance the cost of energy with load-meeting and peak shaving performance. Within the case study, systems designed for wind, solar photovoltaic (PV), and storage resulted in lower cost of energy than those optimized for PV and storage only. This indicates that in areas where wind resource exists, hybrid power plants that include wind, PV, and battery assets can better meet EV charging loads (including peak loads that are prone to overloading local grids) than PV and battery assets alone. Future work to address limitations in this paper include extending cost modeling to include performance losses (e.g., based on operations or weather) and charging station costs to estimate levelized cost of charging, and quantifying uncertainty and error in our aggregation methods for estimating EV charging loads at the hourly timescale.
Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.
This paper explores the solutions for minimizing renewable energy (RE) curtailment in the Texas Electric Reliability Council of Texas (ERCOT) grid. By utilizing current and future planning data from ERCOT and the System Advisor Model from the National Renewable Energy Laboratory, we examine how future renewable energy (RE) initiatives, combined with utility-scale energy storage, can reduce CO2 emissions while reshaping Texas’s energy mix. The study projects the energy landscape from 2023 to 2033, considering the planned phase-out of fossil fuel plants and the integration of new wind/solar projects. By comparing emissions under different load scenarios, with and without storage, we demonstrate storage’s role in optimizing RE utilization. The findings of this paper provide actionable guidance for energy stakeholders, underscoring the need to expand wind and solar projects with strategic storage solutions to maximize Texas's RE capacity and substantially reduce CO2 emissions.
Abstract As part of the ongoing research into the design of hardware for zero emission cycles, a first-stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design three-dimensional with objectives of increasing efficiency and decreasing heat load to the blade. Supercritical CO2 property tables are constructed from NIST REFPROP data for the condensable gas simulation in FINE/Turbo. A detailed mesh sensitivity study is performed for a baseline design to identify the proper-grid refinement and efficiently allocate resources for the optimization. Seventy design variables are selected for the initial population generation. Self-organizing maps are then used to focus the design variables on the most important ones affecting the objective functions. The optimization results in approximately 3000 three-dimensional Reynolds Averaged Navier Stokes simulations of different blade shapes with increases in efficiency of up to 0.85% and decreases in heat load of 14%. Families of blade shapes are identified for experimental testing in an annular rig at the Purdue Experimental Turbine Aerothermal Laboratory. A design to adapt the annular cascade for testing optimized geometries is introduced, which features eccentric radius sectors allowing for scaled-up geometries of sCO2 optimized blade profiles to be tested at design cycle representative conditions at high Reynolds numbers in dry air. Analysis into the effects of Reynolds number, working fluid, and geometric relations are presented to prove the efficacy of the test method.
The electrification of heavy-duty commercial vehicles (HDCVs) is key to enhancing air quality and reducing urban air pollution, but it also imposes significant demands on an electric grid not designed for such high loads. Without complementary infrastructure, electrification may yield limited air quality improvements. This article explores the critical role of microgrids—integrating solar photovoltaics and battery storage—in supporting HDCV electrification. We present an integrated framework to identify viable microgrid sites in a given region, estimate deployment costs, and optimize power use to reduce dependence on the grid. As a case study, we apply the framework to the region around the Port of Savannah, GA, USA, demonstrating how targeted microgrid deployment can enhance grid capacity, improve energy resiliency, and support electrified freight transport.
Total pressure loss is one of the most important parameters in the design of a turbine. This parameter effects not only the turbine performance, but consequently the engine power balance and engine performance. Computational Fluid Dynamics (CFD) can be an effective tool in predicting turbine total pressure loss, and also for performing sensitivity studies to achieve an optimal design with respect to pressure loss. In the present study, the AEROVISC code was used to predict the total pressure loss in the Turbine Technology Team Gas Generator Oxidizer Turbine (GGOT). The objectives in this study are two-fold. It is first necessary to determine an optimal methodology in predicting total pressure loss. The type of grid, grid density and distribution are parameters which may affect the loss prediction. Also, the effect of using a standard K-epsilon turbulence model with wall functions versus a two-layer turbulence model needs to be investigated. The use of grid embedding to resolve areas with high flow gradients needs to be explored. The second objective of the study is to apply the optimal methodology toward evaluating different tip leakage control concepts.
The electric grid was designed with the assumption that all energy generation sources would be relatively controllable, and grid operators would always be able to predict when and where those sources would be located. With the addition of renewable energy sources like wind and solar, which can be installed faster than traditional generation technologies, this is no longer the case. Furthermore, the fact that renewable energy sources are imperfectly predictable means that the grid has to adapt in real-time to changing patterns of power flow. We need a dynamic grid that is far more flexible. This video highlights three ARPA-E-funded approaches to improving the grid's flexibility: topology control software from Boston University that optimizes power flow, gas tube switches from General Electric that provide efficient power conversion, and flow batteries from Harvard University that offer grid-scale energy storage.
Renewables are taking a large proportion of generation capacity in U.S. power grids. As their randomness has increasing influence on power system operation, it is necessary to consider their impact on system expansion planning. To this end, this project studies the generation and transmission expansion co-optimization problem of the US Eastern Interconnection (EI) power grid with a high wind power penetration rate. In this project, the generation and transmission expansion problem for the EI system is modeled as a mixed-integer programming (MIP) problem. This study analyzed a time series creation method to capture the diversity of load and wind power across balancing regions in the EI system. The obtained time series can be easily introduced into the MIP co-optimization problem and then solved robustly through available MIP solvers. Simulation results show that the proposed time series generation method and the expansion co-optimization model and can improve the expansion result significantly after considering the diversity of wind and load across EI regions. The improved expansion plan that combines generation and transmission will aid system planners and policy makers to maximize the social welfare. This study shows that modelling load and wind variations and diversities across balancing regions will produce significantly different expansion result compared with former studies. For example, if wind is modeled in more details (by increasing the number of wind output levels) so that more wind blocks are considered in expansion planning, transmission expansion will be larger and the expansion timing will be earlier. Regarding generation expansion, more wind scenarios will slightly reduce wind generation expansion in the EI system and increase the expansion of other generation such as gas. Also, adopting detailed wind scenarios will reveal that it may be uneconomic to expand transmission networks for transmitting a large amount of wind power through a long distance in the EI system. Incorporating more details of renewables in expansion planning will inevitably increase the computational burden. Therefore, high performance computing (HPC) techniques are urgently needed for power system operation and planning optimization. As a scoping study task, this project tested some preliminary parallel computation techniques such as breaking down the simulation task into several sub-tasks based on chronology splitting or sample splitting, and then assigning these sub-tasks to different cores. Testing results show significant time reduction when a simulation task is split into several sub-tasks for parallel execution.
The optimization of ultrasonic nondestructive evaluation (NDE) simulation tools for composites has the potential to reduce both individual part inspection time and overall certification time for composite parts and structures. Inspection guidance based on simulation provides increased confidence in the veracity of inspection results in addition to time reductions. This paper outlines ongoing work targeted to advance this objective through the use of finite difference (FD) simulation techniques formulated for composite structures with realistic geometries. Two staggered grid explicit FD schemes which show promise for this purpose are assessed: the Lebedev FD scheme and the rotated staggered grid (RSG) FD scheme. Algorithmic points which provide challenges for complex geometries are addressed, in particular handling of traction free surfaces and bi-material interfaces present at lamina boundaries. Code execution time estimates are performed as well to guide feasible domain sizes relative to algorithm choice and available hardware. Three test cases are simulated: a delaminated plate, a cylinder, and a triclinic lamina. These tests demonstrate that the Lebedev FD scheme needs additional work to handle inter-laminar interfaces and traction free boundaries in the presence of stair-stepping approximations. In contrast, the simple structure of the RSG unit cell makes it more straightforward to construct a 3D simulation technique for curved composite laminates.
With the increasing penetration of intermittent renewable energy sources into the grid, there is a growing need for process systems-based strategies that integrate dispatchable and variable energy systems for supplying the demand while maintaining grid reliability. The proposed framework corresponds to a dynamic mixed-integer linear programming optimization approach that integrates coal-fired and natural gas-fired power plants, NaS batteries for energy storage, and solar/wind energy to supply the demand. This optimization approach considers an economic goal and constraints to provide power balance while maintaining the overall damage of the natural gas combined cycle (NGCC) power plant drum under a maximum stress as well as avoiding the overheating of the NGCC superheater and reheater. Renewable curtailment levels are also retained at minimum levels. Case studies are analyzed considering different loads and renewable penetration levels. The results show that the demand was met for all cases. Grid flexibility was mostly provided by the NGCC, while the batteries were used sparingly. In addition, considering a CO 2 equivalent analysis, the environmental performance was intrinsically connected to grid flexibility and the level of renewable penetration. Stress analysis results reinforced the necessity for an equipment health-related constraint.
Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.
Data compression plays a key role in reducing storage and I/O costs. Traditional lossy methods primarily target data on rectilinear grids and cannot leverage the spatial coherence in unstructured mesh data, leading to suboptimal compression ratios. We present a multi-component, error-bounded compression framework designed to enhance the compression of floating-point unstructured mesh data, which is common in scientific applications. Our approach involves interpolating mesh data onto a rectilinear grid and then separately compressing the grid interpolation and the interpolation residuals. This method is general, independent of mesh types and typologies, and can be seamlessly integrated with existing lossy compressors for improved performance. We evaluated our framework across twelve variables from two synthetic datasets and two real-world simulation datasets. The results indicate that the multi-component framework consistently outperforms state-of-the-art lossy compressors on unstructured data, achieving, on average, a 2.3 − 3.5× improvement in compression ratios, with error bounds ranging from 1 × 10 the −6 to 1×10−2. We further investigate impact of hyperparameters, such as grid spacing and error allocation, to deliver optimal compression ratios in diverse datasets.
Power system algorithms such as AC optimal power flow and coordinated volt/var control of the bulk power system are computationally intensive and become difficult to solve in operational time frames. The computational time required to run these algorithms increases exponentially as the size of the power system increases. The solution time for multiple subsystems is less than that for solving the entire system simultaneously, and the local nature of the voltage problem lends itself to such decomposition. This paper describes an algorithm that can be used to perform power system decomposition from the point of view of the voltage control problem. Our approach takes advantage of the dominant localized effect of voltage control and is based on clustering buses according to the electrical distances between them. One of the contributions of the paper is to use multidimensional scaling to compute n-dimensional Euclidean coordinates for each bus based on electrical distance to perform algorithms like K-means clustering. A simple coordinated reactive power control of photovoltaic inverters for voltage regulation is used to demonstrate the effectiveness of the proposed decomposition algorithm and its components. The proposed decomposition method is demonstrated on the IEEE 118-bus system.
Efficient and reliable scheduling of maintenance for power generation and transmission infrastructure is essential for minimizing operational costs and ensuring grid stability. This paper introduces an integrated optimization framework for coordinated maintenance scheduling of generators and transmission lines under resource and reliability constraints. The model minimizes a composite cost function including maintenance and generation costs, as well as penalties for delayed maintenance, while satisfying N−1 security constraints, operational limits, and crew availability. Case studies on the IEEE 300-bus test system demonstrate the effectiveness of the proposed approach in producing feasible and cost-effective maintenance schedules. To address scalability and combinatorial complexity, the model is mapped into a Quadratic Unconstrained Binary Optimization (QUBO) problem, enabling exploration of solution approaches based on Quantum Imaginary Time Evolution (QITE). While the QUBO reformulation provides a foundation for future quantum-inspired optimization, this study focuses primarily on the development and demonstration of the classical optimization framework and illustrates the potential applicability of QITE in large-scale maintenance scheduling.
This chapter introduces several approaches to crystallographic structure refinement from diffraction profile data including the Rietveld method, global optimization methods, and Bayesian modeling. First, the Rietveld method and related nonlinear least squares approaches to analyzing diffraction profiles are briefly discussed. We then review the most common algorithms within global optimization as alternative methods of structure solution: grid search, simulated annealing, and genetic algorithms. As the Rietveld method is the standard tool for analyzing diffraction profile data, we catalogue its challenges and limitations. A Bayesian approach to diffraction profile analysis is presented as an alternative, along with several sampling algorithms including Gibbs sampling, variants of Metropolis sampling, Hamiltonian Monte Carlo, and approximate Bayesian computing. These sampling algorithms are applied to the fitting of a neutron diffraction profile from a National Institute of Standards and Technology silicon standard reference material, and their results are compared.