Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHT SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Beam Diagnostic by Outside Beam Chamber Fields

Fields induced by a beam and penetrated outside the beam pipe can be used for a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can work as a beam pickup. This has very small beam-coupling impedance and avoids complications of having a feed-through. The signal can be reasonably high at low frequencies. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. Such kind of diagnostic can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗

Simple Low-Frequency Beam Pickup

Detection of the field induced by a beam outside of the beam pipe can be used as a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can be used as a beam pickup. This has a very small beam-coupling impedance and avoids complications of having a feedthrough. The signal can be reasonably high at low frequencies. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. These results should be relevant for impedance calculations of the slot in an antechamber and for slots in the PEP-II distributed ion pump screens. The design of the low-frequency beam position monitor is very simple. It can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗

Thermal trim for a luminaire

A luminaire with a thermal pathway to reduce the junction temperature of the luminaire's light source, and methods for so doing, are disclosed. The luminaire includes a can, a light engine, and a trim, that define a substantially continuous thermal pathway from the light engine to a surrounding environment. The can defines a can cavity and includes a can end region. The light engine is within the can cavity and includes a light source and a heat sink, including a heat sink end region, coupled thereto. The trim is at least partially disposed within the can cavity and includes a first trim end region coupled to the heat sink end region and a second trim end region coupled to the can end region. Thermal interface material may be located between: the heat sink and the trim, the trim and the can, and/or the heat sink and the light source.

42 ENGINEERING↗

Thermal trim for luminaire

A luminaire with a thermal pathway to reduce the junction temperature of the luminaire's light source, and methods for so doing, are disclosed. The luminaire includes a can, a light engine, and a trim, that define a substantially continuous thermal pathway from the light engine to a surrounding environment. The can defines a can cavity and includes a can end region. The light engine is within the can cavity and includes a light source and a heat sink, including a heat sink end region, coupled thereto. The trim is at least partially disposed within the can cavity and includes a first trim end region coupled to the heat sink end region and a second trim end region coupled to the can end region. Thermal interface material may be located between: the heat sink and the trim, the trim and the can, and/or the heat sink and the light source.

42 ENGINEERING↗

Meeting Report: International Workshop for New Opportunities in Hard X-ray Photoelectron Spectroscopy: HAXPES 2009

The third international workshop on hard X-ray photoelectron spectroscopy (HAXPES 2009) was held at Brookhaven National Laboratory, Upton, New York, from May 20-22, 2009. This three-day workshop brought together approximately 100 scientists from 14 countries to discuss progress and future prospects for this rapidly developing field of research. The conference was sponsored by the National Synchrotron Light Source, the National Synchrotron Light Source-II Project, Brookhaven National Laboratory Condensed Matter Physics and Materials Science Department, and the National Institute of Standards and Technology.

43 PARTICLE ACCELERATORS↗

Visible-Infrared Hyperspectral Image Projector

The VisIR HIP generates spatially-spectrally complex scenes. The generated scenes simulate real-world targets viewed by various remote sensing instruments. The VisIR HIP consists of two subsystems: a spectral engine and a spatial engine. The spectral engine generates spectrally complex uniform illumination that spans the wavelength range between 380 nm and 1,600 nm. The spatial engine generates two-dimensional gray-scale scenes. When combined, the two engines are capable of producing two-dimensional scenes with a unique spectrum at each pixel. The VisIR HIP can be used to calibrate any spectrally sensitive remote-sensing instrument. Tests were conducted on the Wide-field Imaging Interferometer Testbed at NASA s Goddard Space Flight Center. The device is a variation of the calibrated hyperspectral image projector developed by the National Institute of Standards and Technology in Gaithersburg, MD. It uses Gooch & Housego Visible and Infrared OL490 Agile Light Sources to generate arbitrary spectra. The two light sources are coupled to a digital light processing (DLP(TradeMark)) digital mirror device (DMD) that serves as the spatial engine. Scenes are displayed on the DMD synchronously with desired spectrum. Scene/spectrum combinations are displayed in rapid succession, over time intervals that are short compared to the integration time of the system under test.

Bolcar, Matthew↗

X-ray beam alignment device and method

The present invention provides a bright, focused visible light source that is part of a visible light alignment assembly that is coupled to an X-ray generator. The visible light source projects a bright, focused visible light beam from the X-ray generator through a collimator and object or part to be radiographed and to a detector or film, just as a subsequent X-ray beam eventually is. This allows the operator to quickly and easily visually assess the eventual position and coverage or spread of the X-ray beam and align the X-ray generator, collimator, object or part to be radiographed, and/or detector or film, with a minimum of test radiographs.

Henry, Nathaniel Frederick↗

Terawatt attosecond x-ray source driven by a plasma accelerator

Plasma accelerators can generate ultra-high-brightness electron beams that open the door to light sources with a smaller physical footprint and properties un-achievable with conventional accelerator technology. In this paper, we show that electron beams from Plasma WakeField Accelerators can generate few-cycle coherent tunable soft x-ray pulses with TW peak power and a duration of tens of attoseconds, an order of magnitude more powerful, shorter, and with better stability than state-of-the-art X-ray Free Electron Lasers (XFELs). Such a light source would significantly enhance the ability to experimentally investigate electron dynamics on ultrafast timescales, having a broad-ranging impact across multiple scientific fields. Rather than starting from noise as in typical XFELs, the x-ray emission in this approach is driven by coherent radiation from a pre-bunched, high peak current electron beam of attosecond duration. This relaxes the restrictive tolerances that have hindered progress toward utilizing plasma accelerators as coherent x-ray drivers thus far, presenting a new paradigm for advanced accelerator light source applications.

43 PARTICLE ACCELERATORS↗

Much Ado about Microbunching: Coherent Bunching in High Brightness Electron Beams

The push to provide ever brighter coherent radiation sources has led to the creation of correspondingly bright electron beams. With billions of electrons packed into normalized emittances (phase space) below one micron, collective effects may dominate both the preservation and use of such ultra-bright beams. An important class of collective effects is due to density modulations within the bunch, or microbunching. Microbunching may be deleterious, as in the case of the Microbunching Instability (MBI), or it may drive radiation sources of unprecedented intensity, as in the case of Free Electron Lasers (FELs). In this work we begin by describing models of microbunching due to inherent beam shot noise, which sparks both the MBI as well as SLAC's Linac Coherent Light Source, the world's first hard X-ray laser. We first use this model to propose a mechanism for reducing the inherent beam shot noise as well as for predicting MBI effects. We then describe experimental measurements of the resulting microbunching at LCLS, including optical radiation from the MBI, as well as the first gain length and harmonic measurements from a hard X-ray FEL. In the final chapters, we describe schemes that use external laser modulations to microbunch light sources of the future. In these sections we describe coherent light source schemes for both both linacs and storage rings.

43 PARTICLE ACCELERATORS↗

Optical Profilometers Using Adaptive Signal Processing

A method of adaptive signal processing has been proposed as the basis of a new generation of interferometric optical profilometers for measuring surfaces. The proposed profilometers would be portable, hand-held units. Sizes could be thus reduced because the adaptive-signal-processing method would make it possible to substitute lower-power coherent light sources (e.g., laser diodes) for white light sources and would eliminate the need for most of the optical components of current white-light profilometers. The adaptive-signal-processing method would make it possible to attain scanning ranges of the order of decimeters in the proposed profilometers.

Hall, Gregory A.↗

Using Lasers and X-rays to Reveal the Motion of Atoms and Electrons (LBNL Summer Lecture Series)

Summer Lecture Series 2009: The ultrafast motion of atoms and electrons lies at the heart of chemical reactions, advanced materials with exotic properties, and biological processes such as the first event in vision. Bob Schoenlein, Deputy Director for Science at the Advanced Light Source, will discuss how such processes are revealed by using laser pulses spanning a millionth of a billionth of a second, and how a new generation of light sources will bring the penetrating power of x-rays to the world of ultrafast science.

43 PARTICLE ACCELERATORS↗

Single-Particle Dynamics in Electron Storage Rings with Extremely Low Emittance

Electron storage rings are widely used for high luminosity colliders, damping rings in high-energy linear colliders, and synchrotron light sources. They have become essential facilities to study high-energy physics and material and medical sciences. To further increase the luminosity of colliders or the brightness of synchrotron light sources, the beam emittance is being continually pushed downward, recently to the nanometer region. In the next decade, another order of reduction is expected. This requirement of ultra-low emittance presents many design challenges in beam dynamics, including better analysis of maps and improvement of dynamic apertures. To meet these challenges, we have refined transfer maps of common elements in storage rings and developed a new method to compute the resonance driving terms as they are built up along a beamline. The method is successfully applied to a design of PEP-X as a future light source with 100-pm emittance. As a result, we discovered many unexpected cancelations of the fourth-order resonance terms driven by sextupoles within an achromat.

43 PARTICLE ACCELERATORS↗

Photolithography system including selective light array

A system, device, and method for imparting or transferring a geometric pattern on the surface of a substrate. The device comprises, a housing forming at least a partially enclosed space, a light source body comprising an array of light emitters, a base disposed below the light source body and configured for supporting the substrate having a photoresist layer thereon, and a controller for activating a predetermined number of individual light emitters corresponding to the predetermined geometric pattern. Each individual light emitter within the array of light emitters is selectively activatable to emit a light. The array of light emitters comprises a plurality of light-emitting diodes, a plurality of quantum dots, or both.

Young, Barbara Diane↗

Transmission x-ray microscopy at Diamond-Manchester I13 Imaging Branchline

Full-field Transmission X-ray Microscopy (TXM) has been shown to be a powerful method for obtaining quantitative internal structural and chemical information from materials at the nanoscale. The installation of a Full-field TXM station will extend the current microtomographic capabilities of the Diamond-Manchester I13 Imaging Branchline at Diamond Light Source (UK) into the sub-100 nm spatial resolution range using photon energies from 8 to 14 keV. The dedicated Full-field TXM station will be built in-house with contributions of Diamond Light Source support divisions and via collaboration with the X-ray Optics Group of Paul Scherrer Institut (Switzerland) which will develop state-of-the-art diffractive X-ray optical elements. Preliminary results of the I13 Full-field TXM station are shown. The Full-field TXM will become an important Diamond Light Source direct imaging asset for material science, energy science and biology at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid-State Lighting Using Side-by-Side White Phosphorescent Organic Light-Emitting Diodes

White organic light-emitting diodes (WOLEDs) have become increasingly popular for use in solid-state illumination, where diffuse, large area light sources that achieve a high color rendering index and luminous power efficiency are desirable. Color-tunable emission, where the light source combines emission from multiple, separately addressed color elements, is conveniently provided by WOLEDs for the purpose of adapting the lighting source to a particular illumination requirement. In this work, we demonstrate a method for side-by-side positioning of monochromatic blue and yellow phosphorescent OLED stripes that are combined to create tunable white light, using a high resolution mechanical peel-off patterning method. We achieve a peak luminous power efficiency of 17.1 ± 0.3 lm W –1 and an external quantum efficiency of 11.8 ± 0.2% and demonstrate color tunability of the 1960 Commission Internationale d’Eclairage chromaticity coordinates from (u,v) = (0.33,0.36) to (0.12,0.32). This corresponds to a tuning rnge of the color rendering index from 74 ± 1 to 86 ± 1 and the correlated color temperature from 2000 to 8000 ± 500 K. Here, due to the nondestructive nature of the peel-off technique, patterned devices exhibit a lifetime comparable to conventional, shadow mask-patterned devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of a flat substrate is changed by placing torques (couples) at each end. Depending on the applied couples, one can tune the shape close to a desired tangential cylinder, ellipse or parabola. We review the nature of the bending, requirements and approaches to the mechanical design, describe original optical and at-wavelength techniques for optimal tuning of bendable optics and alignment on the beamline, and provide beamline performance of the bendable optics used for sub-micro and nano focusing of soft x-rays.

42 ENGINEERING↗

Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research

Purpose: In preclinical radiation research, it is challenging to localize soft tissue targets based on cone beam computed tomography (CBCT) guidance. As a more effective method to localize soft tissue targets, we developed an online bioluminescence tomography (BLT) system for small-animal radiation research platform (SARRP). We demonstrated BLT-guided radiation therapy and validated targeting accuracy based on a newly developed reconstruction algorithm. Methods and Materials: The BLT system was designed to dock with the SARRP for image acquisition and to be detached before radiation delivery. A 3-mirror system was devised to reflect the bioluminescence emitted from the subject to a stationary charge-coupled device (CCD) camera. Multispectral BLT and the incomplete variables truncated conjugate gradient method with a permissible region shrinking strategy were used as the optimization scheme to reconstruct bioluminescent source distributions. To validate BLT targeting accuracy, a small cylindrical light source with high CBCT contrast was placed in a phantom and also in the abdomen of a mouse carcass. The center of mass (CoM) of the source was recovered from BLT and used to guide radiation delivery. The accuracy of the BLT-guided targeting was validated with films and compared with the CBCT-guided delivery. In vivo experiments were conducted to demonstrate BLT localization capability for various source geometries. Results: Online BLT was able to recover the CoM of the embedded light source with an average accuracy of 1 mm compared to that with CBCT localization. Differences between BLT- and CBCT-guided irradiation shown on the films were consistent with the source localization revealed in the BLT and CBCT images. In vivo results demonstrated that our BLT system could potentially be applied for multiple targets and tumors. Conclusions: The online BLT/CBCT/SARRP system provides an effective solution for soft tissue targeting, particularly for small, nonpalpable, or orthotopic tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quasiclassical Computations of Compton-Scattered Spectra

Quality X-ray sources are crucial to fundamental physics research, medical radiology, humanities research, and materials science. While synchrotron radiation (SR) facilities produce the state-of-the-art emissions with respect to brilliance and frequency tunability, the great expense required to build, maintain, and operate these structures greatly limits their accessibility to researchers. Much of the research conducted at SR facilities, however, may be conducted with inverse Compton sources (ICS). Accelerator-based Compton scattering light sources generate high-energy, high-brilliance emissions. Compton scattering is the process by which a photon scatters o? an electron. ICS offer an affordable, in-lab alternative to SR facilities. Even though SR facilities produce greater intensity emissions, Compton sources provide the same frequency tunability at the intensities suitable for the purposes of many researchers currently fighting for time at SR facilities, i.e., ICS provides intensities suitable for contrast imaging, X-ray fluorescence, X-ray-diffraction, and X-ray spectroscopy. The focus of this work is to create computational models to simulate Compton-scattered spectra. These models have been used to build a theoretical basis for methods of improving the quality of future Compton sources and to preform diagnostic analysis of existing light sources. The theoretical basis of each model is derived from first principles. The numerical methods employed by each model are defined. A full description of the various functionalities of each code will be addressed. Furthermore, an in-depth analysis of spectral bandwidth sources is discussed. The complex physics arising from an extremely high-intensity, nonlinear laser pulse is explored in detail. Methods of frequency modulation of the incident laser, i.e., a method for correcting the nonlinear broadening effects on the scattered spectrum, will also be discussed. The work will conclude with a an exploration of the ongoing research efforts regarding regimes of operation outside of the limits of these current models.

Johnson, Erik↗