Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Contamination effects study

The in-situ optical surface measurement system is a facility designed to study the deleterious effects of particulate materials on the surface reflectivities of optical materials in the vacuum ultraviolet (VUV). This arrangement is designed to simulate the on-orbit effects of contamination and degradation of optical surfaces. This simulation is accomplished through the use of non-coherent VUV sources illuminating optical surfaces located in a high vacuum chamber. Several sources of contamination are employed. The reflectivity is measured both at the specular reflection as well as at two scattered positions, forward and reverse. The system components are described and an operating procedure is given.

Source record↗

Prospects for a contamination-free ultravacuum facility in low-earth orbit

The old concept of using the wake of a spacecraft to obtain an ultrahigh vacuum is revisited. A wakeshield can be configured so that a surface of interest does not subtend any walls that could become contaminated, thus it should be possible to achieve a contamination-free, ultrahigh vacuum capability with infinite pumping speed even in the presence of high heat loads and moderate gas loads. This papar analyzes the conceptual design for a Space Ultravacuum Research Facility (SURF), both in a shuttle-attached mode and as a free flyer. It is shown that even in the shuttle-attached mode, it should be possible to obtain vacuum levels equivalent to 10 to the -9th to 10 to the -10th Torr with O and N2 as the primary constituents. As a free flyer the SURF will be limited primarily by the gas load from the process being performed. For chemical beam epitaxy it is shown that equivalent vacuum levels of 10 to the -14th Torr should be possible at 300 km.

Naumann, Robert J.↗

Noise-Contamination Detector

Deviations in periods of output from tracking filter measured. Signal-analyzing system measures degree to which sinusoid contaminated by noise. Noise-contamination detector indirectly measures noise in noisy sinusoidal signal by measuring average value of fractional absolute dither in period of signal. Developed to measure noise in outputs of vibration sensors used to test bearings and other components of rotating machinery.

Randall, Richard L.↗

X-Ray Fluorescence Surface-Contamination Detector

X-ray spectrum of contaminating element reveals presence. Proposed x-ray fluorescence spectrometer used to detect thin layer of Conoco HD-2 (or equivalent) grease on D6-ac steel. Source-and-detector assembly mounted on remote manipulator with other contamination-detecting equipment and scanned across surface of specimen. Output of detector fed through coaxial cable to standard pulse-height-analyzing equipment and processed further by small computer to obtain x-ray energy spectrum.

Eldridge, Hudson B.↗

Concentrating Gaseous Contaminants For Monitoring

Apparatus concentrates contaminants outgassing from specimens in vacuum and passes concentrated contaminants to gas-chromatography/mass-spectrometry system for analysis. Cold wall of collection chamber adsorbs gases from specimen in isothermal cell. When wall heated, plate desorbs gases so they can be analyzed. Collection chamber maintained at low pressure throughout adsorption and desorption process. Determines whether candidate materials for use in vacuum environments generate harmful substances.

Mahone, William C.↗

The rodent research animal holding facility as a barrier to environmental contamination

The rodent Research Animal Holding Facility (RAHF), developed by NASA Ames Research Center (ARC) to separately house rodents in a Spacelab, was verified as a barrier to environmental contaminants during a 12-day biocompatibility test. Environmental contaminants considered were solid particulates, microorganisms, ammonia, and typical animal odors. The 12-day test conducted in August 1988 was designed to verify that the rodent RAHF system would adequately support and maintain animal specimens during normal system operations. Additional objectives of this test were to demonstrate that: (1) the system would capture typical particulate debris produced by the animal; (2) microorganisms would be contained; and (3) the passage of animal odors was adequately controlled. In addition, the amount of carbon dioxide exhausted by the RAHF system was to be quantified. Of primary importance during the test was the demonstration that the RAHF would contain particles greater than 150 micrometers. This was verified after analyzing collection plates placed under exhaust air ducts and rodent cages during cage maintenance operations, e.g., waste tray and feeder changeouts. Microbiological testing identified no additional organisms in the test environment that could be traced to the RAHF. Odor containment was demonstrated to be less than barely detectable. Ammonia could not be detected in the exhaust air from the RAHF system. Carbon dioxide levels were verified to be less than 0.35 percent.

Savage, P. D., Jr.↗

Spacecraft external molecular contamination analysis

Control of contamination on and around spacecraft is required to avoid adverse effects on the performance of instruments and spacecraft systems. Recent work in this area is reviewed and discussed. Specific issues and limitations to be considered as part of the effort to predict contamination effects using modeling techniques are addressed. Significant results of Space Shuttle missions in the field of molecule/surface interactions as well as their implications for space station design and operation are reviewed.

Ehlers, H. K. F.↗

Satellite material contaminant optical properties

The Air Force Wright Research and Development Center and the Arnold Engineering Development Center are continuing a program for measuring optical effects of satellite material outgassing products on cryo-optic surfaces. Presented here are infrared (4000 to 700 cm(-1)) transmittance data for contaminant films condensed on a 77 K geranium window. From the transmittance data, the contaminant film refractive and absorptive indices (n, k) were derived using an analytical thin-film interference model with a nonlinear least-squares algorithm. To date 19 materials have been studied with the optical contents determined for 13 of those. The materials include adhesives, paints, composites, films, and lubricants. This program is continuing and properties for other materials will be available in the future.

Wood, B. E.↗

Planetary protection and back contamination control for a Mars rover sample return mission

A commitment to avoid the harmful contamination of outer space and avoid adverse changes in the environment of the earth has been long reflected in NASA's Planetary Protection policy. Working under guidelines developed by the Committee on Space Research (COSPAR), NASA has implemented the policy in an interactive process that has included the recommendations of the U.S. National Academy of Sciences. Measures taken to prevent the contamination of earth during the Apollo missions were perhaps the most visible manifestations of this policy, and provided numerous lessons for future sample return opportunities. This paper presents the current status of planetary protection policy within NASA, and a prospectus on how planetary protection issues might be addressed in relation to a Mars Rover Sample Return mission.

Rummel, John D.↗

The rodent Research Animal Holding Facility as a barrier to environmental contamination

The rodent Research Animal Holding Facility (RAHF), developed by NASA Ames Research Center (ARC) to separately house rodents in a Spacelab, was verified as a barrier to environmental contaminants during a 12-day biocompatibility test. Environmental contaminants considered were solid particulates, microorganisms, ammonia, and typical animal odors. The 12-day test conducted in August 1988 was designed to verify that the rodent RAHF system would adequately support and maintain animal specimens during normal system operations. Additional objectives of this test were to demonstrate that: (1) the system would capture typical particulate debris produced by the animal; (2) microorganisms would be contained; and (3) the passage of animal odors was adequately controlled. In addition, the amount of carbon dioxide exhausted by the RAHF system was to be quantified. Of primary importance during the test was the demonstration that the RAHF would contain particles greater than 150 micrometers. This was verified after analyzing collection plates placed under exhaust air ducts and and rodent cages during cage maintenance operations, e.g., waste tray and feeder changeouts. Microbiological testing identified no additional organisms in the test environment that could be traced to the RAHF. Odor containment was demonstrated to be less than barely detectable. Ammonia could not be detected in the exhaust air from the RAHF system. Carbon dioxide levels were verified to be less than 0.35 percent.

Savage, P. D., Jr.↗

The reactive bed plasma system for contamination control

The contamination control capabilities of the Reactive Bed Plasma (RBP) system is described by delineating the results of toxic chemical composition studies, aerosol filtration work, and other testing. The RBP system has demonstrated its capabilities to decompose toxic materials and process hazardous aerosols. The post-treatment requirements for the reaction products have possible solutions. Although additional work is required to meet NASA requirements, the RBP may be able to meet contamination control problems aboard the Space Station.

Birmingham, Joseph G.↗

Contamination control program for the Cosmic Background Explorer: An overview

Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.

Barney, Richard D.↗

Migration and generation of contaminants from launch through recovery: LDEF case history

The migration of contaminants to and between Long Duration Exposure Facility (LDEF) surfaces reveals new information relevant to all future space missions. The surface of the LDEF satellite closely paralleled over seven meters of the shuttle during one launch and one reentry. Transfer of contaminants from the shuttle bay to the payload were documented and partially quantified for both the launch and recovery separately. LDEF carried a load of volatile silicones and hydrocarbons into orbit which were then polymerized by UV radiation into tough, dark brown stains on exposed surfaces. The distribution of these stains is providing new information on deposition mechanisms that should be studied on future missions. Electrostatic effects, diffusional flow, and effects due to small surface temperature differences at the time of UV exposure are suggested. The types of functional groups present in the LDEF deposit it nearly identical to stains recovered from other spacecraft. These stains were remarkably stable in low Earth orbit even with atomic oxygen exposure if the amount of silicones present was sufficient to create a sealing layer of silicon dioxide over the dark brown stain beneath.

Crutcher, E. Russ↗

Contamination control program for the Cosmic Background Explorer

Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.

Barney, Richard D.↗

Contamination study

The time dependence of the angular reflectance from molecularly contaminated optical surfaces in the Vacuum Ultraviolet (VUV) is measured. The light scattering measurements are accomplished in situ on optical surfaces in real time during deposition of molecular contaminants. The measurements are taken using non-coherent VUV sources with the predominant wavelengths being the Krypton resonance lines at 1236 and 1600 A. Detection of the scattered light is accomplished using a set of three solar blind VUV photomultipliers. An in-plane VUV BRDF (Bidirectional Reflectance Distribution Functions) experiment is described and details of the ongoing program to characterize optical materials exposed to the space environment is reported.

Johnson, R. Barry↗

XPS study of the effect of hydrocarbon contamination on polytetrafluoroethylene (teflon) exposed to atomic oxygen

The presence of hydrocarbon contamination on the surface of polytetrafluoroethylene (PTFE) markedly affects the oxygen uptake, and hence the wettability, of this polymer when exposed to an oxygen plasma. As revealed by X-ray photoelectron spectroscopy (XPS) analysis, the oxygen-to-carbon ratio (O/C) for such a polymer can increase sharply, and correspondingly the fluorine-to-carbon ratio (F/C) can decrease sharply, at very short exposure times; at longer times, however, such changes in the O/C and F/C ratios reverse direction, and these ratios then assume values similar to those of the unexposed PTFE. The greater the extent of hydrocarbon contamination in the PTFE, the larger are the amplitudes of the 'spikes' in the O/C- and F/C-exposure time plots. In contrast, a pristine PTFE experiences a very small, monotonic increase of surface oxidation or O/C ratio with time of exposure to oxygen atoms, while the F/C ratio is virtually unchanged from that of the unexposed polymer (2.0). Unless the presence of adventitious hydrocarbon is taken into account, anomalous surface properties relating to polymer adhesion may be improperly ascribed to PTFE exposed to an oxygen plasma.

Golub, Morton A.↗

Biological Contamination of Mars: Issues and Recommendations

The ad hoc Task Group on Planetary Protection formed by the Space Studies Board (SSB) of the National Research Council focused on making recommendations concerning the protection of Mars from forward contamination (i.e., Earth to Mars) during upcoming missions by both the United States and the former Soviet Union. In so doing, it distinguished between missions whose goals include reconnaissance and measurement and those that specifically include experiments to detect life. The task group also discussed what additional knowledge will be needed in order to assure that future recommendations regarding contamination of Earth from Mars might be made with a higher degree of certainty than is now possible. Following a short introduction to the rationale underlying planetary exploration (Chapter 1) is a brief summary of approved and contemplated missions to Mars (Chapter 2). Chapter 3 briefly reviews the state of knowledge in several areas pertinent to the problem of planetary protection, in the limits of life on Earth and the abilities of known terrestrial organisms to withstand extreme environment conditions, as well as new approaches to detecting life forms. Chapter 5 includes a review and comments (made in light of current knowledge)- on the recommendations made in 'Recommendations on Quarantine Policy for Mars, Jupiter, Saturn, Uranus, Neptune, and Titan'. Updates to the recommendations made in 1978 are also given in Chapter 5. Chapter 6 gives additional recommendations concerning collection of essential data, spacecraft sterilization and bioburden assessment, and future research, as well as legal and social issues and NASA's overall planetary protection program.

Source record↗

ESCA study of the effect of hydrocarbon contamination on poly(tetrafluoroethylene) exposed to atomic oxygen plasma

The ESCA spectra and data obtained by Morra et al. (1989) on poly(tetrafluoroethylene) (PTFE) exposed to atomic oxygen plasma are closely reexamined. It is shown that the spikes observed in Morra et al. plots of O/C or F/C versus time of the exposure of PTFE to atomic oxygen plasma were not characteristic of PTFE per se but were instead a result of a contamination by hydrocarbon present in their PTFE samples. This was demonstrated experimentally by comparing data derived for a very clean PTFE sample exposed for 10, 20, and 30 min to oxygen plasma with data obtained on PTFE samples with very small amounts of hydrocarbon contamination.

Golub, Morton A.↗