Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Photonic Software Defined Radio

Wireless links are the most popular form of communications with an ever-growing demand for speed. This has resulted in an overpopulated Radio Frequency (RF) spectrum with not enough bandwidth to meet demand. The two main tactics utilized by the wireless community to overcome this problem is to 1) put more data in a given bandwidth, i.e. higher spectral efficiency and 2) use the available bandwidth more efficiently by tuning the user’s channel (i.e. carrier frequency) to an unused part of spectrum. Higher spectral efficiency is achieved by using complex signals that carry information on both the in-phase (I) carrier and quadrature-phase (Q) carrier, known as Quadrature Amplitude Modulation (QAM), and increasing the number of levels on each carrier, known as the constellation size (4QAM, 16QAM etc.). However higher constellation sizes and higher bandwidth require higher fidelity RF signals. This project looked at a photonic-based high-fidelity RF amplitude and phase modulator which modulates the amplitude and phase of femtosecond laser pulses to generate relatively high-power complex microwave waveforms at carrier frequencies up to 70GHz. The goal of the feasibility study was to build a proof-of-concept system in a laboratory setting that demonstrates the photonic generation of QAM signals at electronically tunable RF carrier frequencies. Our lab prototype achieved a signal-to-noise-and-distortion (SINAD) ratio of 39dB over a 500MHz bandwidth. The signal-to-noise ratio (SNR) of the system was measured at 42dB over a 500MHz bandwidth which is on par with state-of-the-art. The main limitation to the SINAD was the inadequate pre-compensation of the electronic Digital-to-Analog Converter (eDAC) and amplifier frequency response as well as the noise of the measurement equipment. This was backed up by simulations which showed that with perfect pre compensation and using ideal measurement equipment, a noise limited SINAD of 47dB could be achieved. We also showed, through simulations, that multiple DACs could be “optically stacked” to achieve 54dB SINAD.

42 ENGINEERING↗

Improving Soft-Tissue Contrast in Four-Dimensional Computed Tomography Images of Liver Cancer Patients Using a Deformable Image Registration Method

Purpose: To investigate a deformable image registration method to improve soft-tissue contrast in four-dimensional (4D) computed tomography (CT) images of the liver. Methods and Materials: Ten patients with hepatocellular carcinoma underwent 4D CT scan for radiotherapy treatment planning on a positron emission tomography/CT scanner. Four-dimensional CT images were binned into 10 equispaced phases. The exhale phase served as the reference phase, and images from the other nine phases were coregistered to the reference phase image using an intensity-based, automatic deformable image registration method. Then the coregistered images were combined to create a single, high-quality reconstructed CT image at exhale phase as the new reference for target delineation. The extent of image quality enhancement was quantified relative to the original CT by calculating the signal-to-noise ratio and the contrast-to-noise ratio. Results: The soft tissue image contrast was noticeably better after deformable image registration than in the original scans. Signal-to-noise ratios inside the liver region of interest increased for all patients by a factor of 3.0 (range, 2.3-3.7). The improvement in image quality was not linearly proportionate to the number of images averaged. Using only 6 phases can achieve at least 85% of the contrast enhancement that can be achieved using all 10 phases. We also found that contrast enhancement was inversely proportional to the original image quality (p = 0.006), and the contrast enhancement is attained with little loss of spatial resolution. Conclusions: This deformable image registration method is feasible to improve soft-tissue image quality in 4D CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GALAXY CLUSTERS DISCOVERED VIA THE SUNYAEV-ZEL'DOVICH EFFECT IN THE 2500-SQUARE-DEGREE SPT-SZ SURVEY

We present a catalog of galaxy clusters selected via their Sunyaev-Zel'dovich (SZ) effect signature from 2500 deg{sup 2} of South Pole Telescope (SPT) data. This work represents the complete sample of clusters detected at high significance in the 2500 deg{sup 2} SPT-SZ survey, which was completed in 2011. A total of 677 (409) cluster candidates are identified above a signal-to-noise threshold of ξ = 4.5 (5.0). Ground- and space-based optical and near-infrared (NIR) imaging confirms overdensities of similarly colored galaxies in the direction of 516 (or 76%) of the ξ > 4.5 candidates and 387 (or 95%) of the ξ > 5 candidates; the measured purity is consistent with expectations from simulations. Of these confirmed clusters, 415 were first identified in SPT data, including 251 new discoveries reported in this work. We estimate photometric redshifts for all candidates with identified optical and/or NIR counterparts; we additionally report redshifts derived from spectroscopic observations for 141 of these systems. The mass threshold of the catalog is roughly independent of redshift above z ∼ 0.25 leading to a sample of massive clusters that extends to high redshift. The median mass of the sample is M {sub 500c}(ρ{sub crit}) ∼3.5×10{sup 14} M{sub ⊙} h{sub 70}{sup −1}, the median redshift is z {sub med} = 0.55, and the highest-redshift systems are at z > 1.4. The combination of large redshift extent, clean selection, and high typical mass makes this cluster sample of particular interest for cosmological analyses and studies of cluster formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP ) OBSERVATIONS: POWER SPECTRA AND WMAP-DERIVED PARAMETERS

The WMAP mission has produced sky maps from seven years of observations at L2. We present the angular power spectra derived from the seven-year maps and discuss the cosmological conclusions that can be inferred from WMAP data alone. With the seven-year data, the temperature (TT) spectrum measurement has a signal-to-noise ratio per multipole that exceeds unity for l < 919; and in band powers of width {Delta}l = 10, the signal-to-noise ratio exceeds unity up to l = 1060. The third acoustic peak in the TT spectrum is now well measured by WMAP. In the context of a flat {Lambda}CDM model, this improvement allows us to place tighter constraints on the matter density from WMAP data alone, {Omega}{sub m} h {sup 2} = 0.1334{sup +0.0056}{sub -0.0055}, and on the epoch of matter-radiation equality, z{sub eq} = 3196{sup +134}{sub -133}. The temperature-polarization (TE) spectrum is detected in the seven-year data with a significance of 20{sigma}, compared to 13{sigma} with the five-year data. We now detect the second dip in the TE spectrum near l {approx} 450 with high confidence. The TB and EB spectra remain consistent with zero, thus demonstrating low systematic errors and foreground residuals in the data. The low-l EE spectrum, a measure of the optical depth due to reionization, is detected at 5.5{sigma} significance when averaged over l = 2-7: l(l + 1)C {sup EE}{sub l}/(2{pi}) = 0.074{sup +0.034}{sub -0.025} {mu}K{sup 2} (68% CL). We now detect the high-l, 24 {<=} l {<=} 800, EE spectrum at over 8{sigma}. The BB spectrum, an important probe of gravitational waves from inflation, remains consistent with zero; when averaged over l = 2-7, l(l + 1)C {sup BB}{sub l}/(2{pi}) < 0.055 {mu}K{sup 2} (95% CL). The upper limit on tensor modes from polarization data alone is a factor of two lower with the seven-year data than it was using the five-year data. The data remain consistent with the simple {Lambda}CDM model: the best-fit TT spectrum has an effective {chi}{sup 2} of 1227 for 1170 degrees of freedom, with a probability to exceed of 9.6%. The allowable volume in the six-dimensional space of {Lambda}CDM parameters has been reduced by a factor of 1.5 relative to the five-year volume, while the {Lambda}CDM model that allows for tensor modes and a running scalar spectral index has a factor of three lower volume when fit to the seven-year data. We test the parameter recovery process for bias and find that the scalar spectral index, n{sub s} , is biased high, but only by 0.09{sigma}, while the remaining parameters are biased by <0.15{sigma}. The improvement in the third peak measurement leads to tighter lower limits from WMAP on the number of relativistic degrees of freedom (e.g., neutrinos) in the early universe: N{sub eff}>2.7(95%CL). Also, using WMAP data alone, the primordial helium mass fraction is found to be Y{sub He} = 0.28{sup +0.14}{sub -0.15}, and with data from higher-resolution cosmic microwave background experiments included, we now establish the existence of pre-stellar helium at >3{sigma}. These new WMAP measurements provide important tests of big bang cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Methodology for deriving the telescope focus function and its uncertainty for a heterodyne pulsed Doppler lidar

Doppler lidars provide two measured parameters, radial velocity and signal-to-noise ratio, from which winds and turbulent properties are routinely derived. Attenuated backscatter, which gives quantitative information on aerosols, clouds, and precipitation in the atmosphere, can be used in conjunction with the winds and turbulent properties to create a sophisticated classification of the state of the atmospheric boundary layer. Calculating attenuated backscatter from the signal-to-noise ratio requires accurate knowledge of the telescope focus function, which is usually unavailable. Inaccurate assumptions of the telescope focus function can significantly deform attenuated backscatter profiles, even if the instrument is focused at infinity. Here, we present a methodology for deriving the telescope focus function using a co-located ceilometer for pulsed heterodyne Doppler lidars. The method was tested with Halo Photonics StreamLine and StreamLine XR Doppler lidars but should also be applicable to other pulsed heterodyne Doppler lidar systems. The method derives two parameters of the telescope focus function, the effective beam diameter and the effective focal length of the telescope. Additionally, the method provides uncertainty estimates for the retrieved attenuated backscatter profile arising from uncertainties in deriving the telescope function, together with standard measurement uncertainties from the signal-to-noise ratio. The method is best suited for locations where the absolute difference in aerosol extinction at the ceilometer and Doppler lidar wavelengths is small.

54 ENVIRONMENTAL SCIENCES↗

Optimal Gaussian squeezed states for atom interferometry in the presence of phase diffusion

We optimize the signal-to-noise ratio of a Mach-Zehnder atom interferometer with Gaussian squeezed input states in the presence interactions. For weak interactions, our results coincide with those of Huang and Moore [Y. P. Huang and M. G. Moore, Phys. Rev. Lett. 100, 250406 (2008)], with an optimal initial number variance {sigma}{sub o{proportional_to}}N{sup 1/3} and an optimal signal-to-noise ratio s{sub o{proportional_to}}N{sup 2/3} for the total atom number N. As the interaction strength u increases past unity, phase diffusion becomes dominant, leading to a transition in the optimal squeezing from initial number squeezing to initial phase squeezing with {sigma}{sub o{proportional_to}{radical}}(uN) and s{sub o{proportional_to}{radical}}(N/u) shot-noise scaling. The initial phase squeezing translates into hold-time number squeezing, which is less sensitive to interactions than coherent states and improves s{sub o} by a factor of {radical}(u).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of LSI to signal detection: The deltic DFPCC

The development of the DELTIC DFPCC serial mode signal processor is discussed. The processor is designed to detect in the presence of background noise a signal coded into the zero crossings of the waveform. The unique features of the DELTIC DFPCC include versatility in handling a variety of signals and relative simplicity in implementation. A theoretical performance model is presented which predicts the expected value of the output signal as a function of the input signal to noise ratio. Experimental results obtained with the prototype system, which was breadboarded with LSI, MSI and SSI components, are given. The device was compared with other LSI schemes for signal processing and it was concluded that the DELTIC DFPCC is simpler and in some cases more versatile than other systems. With established LSI technology, low frequency systems applicable to sonar and similar problems are feasible.

Gassaway, J. D.↗

Quality Control of Additively Manufactured Metallic Structures with Machine Learning of Thermography Images

Additive manufacturing (AM) of high-strength metals is currently based on the laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Quality control (QC) requires nondestructive evaluation of actual AM structures. Flash thermography is a potentially promising QC technique because it is scalable to arbitrary structure size. However, the detection sensitivity of this method is limited by noise. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatial–temporal blind source separation and spatial–temporal sparse dictionary learning methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced by the LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, the ML methods with higher accuracy require a longer runtime. However, this runtime is sufficiently short to perform QC within a realistic time frame.

36 MATERIALS SCIENCE↗

A laboratory validation study of the time-lapse oscillatory pumping test for leakage detection in geological repositories

Geologic repositories are extensively used for disposing byproducts in mineral and energy industries. The safety and reliability of these repositories are a primary concern to environmental regulators and the public. Time-lapse oscillatory pumping test (OPT) has been introduced recently as a pressure-based technique for detecting potential leakage in geologic repositories. By routinely conducting OPT at a number of pulsing frequencies, an operator may identify the potential repository anomalies in the frequency domain, alleviating the ambiguity caused by reservoir noise and improving the signal-to-noise ratio. Building on previous theoretical and field studies, this work performed a series of laboratory experiments to validate the concept of time-lapse OPT using a custom made, stainless steel tank under relatively high pressures. The experimental configuration simulates a miniature geologic storage repository consisting of three layers (i.e., injection zone, caprock, and above-zone aquifer). Here results show that leakage in the injection zone led to deviations in the power spectrum of observed pressure data, and the amplitude of which also increases with decreasing pulsing frequencies. The experimental results are further analyzed by developing a 3D flow model, using which the model parameters are estimated through frequency domain inversion.

58 GEOSCIENCES↗

Masses of Sunyaev-Zel’dovich galaxy clusters detected by the Atacama Cosmology Telescope: Stacked lensing measurements with Subaru HSC year 3 data

We present a stacked lensing analysis of 96 galaxy clusters selected by the thermal Sunyaev-Zel’dovich (SZ) effect in maps of the cosmic microwave background (CMB). We select foreground galaxy clusters with a 5 σ -level SZ threshold in CMB observations from the Atacama Cosmology Telescope, while we define background source galaxies for the lensing analysis with secure photometric redshift cuts in Year 3 data of the Subaru Hyper Suprime Cam survey. We detect the stacked lensing signal in the range of 0.1 < R [ h - 1 Mpc ] < 100 in each of three cluster redshift bins, 0.092 < z ≤ 0.445 , 0.445 < z ≤ 0.695 , and 0.695 < z ≤ 1.180 , with 32 galaxy clusters in each bin. The cumulative signal-to-noise ratios of the lensing signal are 14.6, 12.0, and 6.6, respectively. Using a halo-based forward model, we then constrain statistical relationships between the mass inferred from the SZ observation (i.e. SZ mass) and the total mass derived from our stacked lensing measurements. At the average SZ mass in the cluster sample ( 2.1 - 2.4 × 10 14 h - 1 M ⊙ ), our likelihood analysis shows that the average total mass differs from the SZ counterpart by a factor of 1.3 ± 0.2 , 1.6 ± 0.2 , and 1.6 ± 0.3 (68%) in the aforementioned redshift ranges, respectively. Our limits are consistent with previous lensing measurements, and we find that the cluster modeling choices can introduce a 1 σ -level difference in our parameter inferences.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Defects in Additively Manufactured Metallic Materials with Machine Learning of Pulsed Thermography Images

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Quality control (QC) requires nondestructive evaluation (NDE) of actual AM structures. Pulsed thermography is a potentially promising QC technique because it is scalable to arbitrary structure size. However, detection sensitivity of this method is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. The ML methods with higher accuracy require longer run time. However, this runtime is sufficiently short to perform QC within a realistic time frame.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials (Second Annual Progress Report)

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer, and through reconstruction of data obtained from experimental measurements. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and Inconel 718 plate produced with laser powder bed fusion (LPBF) method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBH’s have the same sizes as the imprinted defects in the LPBF specimens, but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects, and allow for estimation of their sizes and locations. Detection sensitivity of TT is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, we investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

Detection of Anomalies in Environmental Gamma Radiation Background with Hopfield Artificial Neural Network - Consortium on Nuclear Security Technologies (CONNECT) Q3 Report

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to investigate performance of a Hopfield Neural Network (HNN) in in detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign. One data set contained a 137 Cs source, and another dataset contained a 131 I source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Hopfield Artificial Neural Network for Anomaly Detection in Environmental Gamma Radiation Background: Consortium on Nuclear Security Technologies (CONNECT) (Q2 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore supervised machine learning (ML) algorithms for development of a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm for detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Anomalies in Gamma Background Radiation Data with K-Means and Self-Organizing Map Clustering Algorithms (Consortium on Nuclear Security Technologies (CONNECT) Q1 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. The challenge is that spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Diffraction Measurement of Reaction Products in Shock Compressed TATB on the NIF

The shock-induced reaction of high explosives to gaseous and solid reaction products is a rapid, complex process. Understanding solid reaction product structure and formation kinetics is essential in determining the high-pressure equation of state of these multicomponent systems. We use the National Ignition Facility (NIF) to shock compress ~500-µm thick pressed powder high-explosive TATB samples to 70-135 GPa and collect in situ structural data on detonation byproducts using the TARDIS X-ray diffraction diagnostic. Velocimetry is used to record the transmitted compression wave profile, which is well described by Cheetah hydrocode simulations coupled with a reactive flow model, providing strong evidence of reaction in the TATB sample. While an unambiguous determination of the product phases was not possible owing to the low signal-to-noise quality of the diffraction signal, X-ray diffraction data of the product phases formed within the first 50 ns of the reaction is most consistent with a mixture of amorphous products and crystalline hexagonal diamond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗