Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Chemical contamination remote sensing

A ground mobile laser test bed system was assembled to assess the feasibility of detection of various types of chemical contamination using Differential Scattering (DISC) and Differential Absorption (DIAL) Lidar techniques. Field experiments with the test bed system using chemical simulants were performed. Topographic reflection and range resolved DIAL detection of vapors as well as DISC detection of aerosols and surface contamination were achieved. Review of detection principles, design of the test bed system, and results of the experiments are discussed.

Carrico, J. P.↗

Genetic toxicity studies of organic chemicals found as contaminants in spacecraft cabin atmospheres

Astronauts can be exposed during spaceflight to organic chemical contaminants in the spacecraft cabin atmosphere. Toxic exposures may cause lesions in the cellular DNA which are subsequently expressed as sister-chromatid exchanges (SCE). Analysis of SCE is a sensitive short term assay techinque to detect and quantitate exposures to DNA damaging (mutagenic) substances. The increase in SCE incidence over baseline (control) levels is generally proportional to the concentration of the mutagen and to the duration of exposure. The BHK-21 baby hamster kidney cell line was the in vitro test system used. Test organics were added to the culture media for 18 hrs, in concentrations ranging from one to 20 ppm. Acetaldehyde and carbon disulfide were chosen for this study since they have occurred as atmospheric contaminants in many of the STS flights, and have been reported to have toxic and mutagenic effects in various test systems. Glutaraldehyde was chosen because few data are available on the mutagenicity of this common fixative, which is carried on STS flights for use in biological experiments. Acetaldehyde was a very strong inducer of SCE at concentrations of 2 ppm and above. Glutaraldehyde and carbon disulfide failed to induce SCE.

Torres, Joseph, Jr.↗

Contamination Barrier For Contour-Molding Material

Release agent prevents molding compound from adhering to or contaminating surface. Cleaning agent, Turco 4215 NCLT, forms barrier preventing silicone molding compound from sticking to surface and leaving contaminating residue. Also see MFS-29243.

Adams, James F.↗

Space station contamination considerations

The external induced environment generated by space station activity, or more specifically by gases, particles, and light background is discussed. These contaminant species must be controlled if sensitive systems, such as solar energy collectors or science experiments exposed to the external environment are to function properly. The requirements generally set limits on the level of gas species, matter deposited on surfaces and light background levels over various spectral regions. They also address environment monitoring and contamination controls during manufacturing. Limits on effluent release and system leakages are in turn derived from these requirements.

Leger, L.↗

Analysis of contamination data recorded by the IECM camera/photometer

The Camera/Photometer was one of the ten instruments comprising the Induced Environment Contamination Monitor (IECM) developed to monitor the contamination about the Space Shuttle Orbiter during early missions. This experiment consisted of two motion picture cameras, integrating photometers, and associated electronics enclosed in pressurized canisters and separated by 40 cm in order to make stereoscopic observation of particulates. The objectives of the experiment were to record the occurrence of particulates and to determine their velocities, sizes and origins, as well as to measure the background brightness due to unresolved particles. Particle tracks were detected on over 1800 data frames recorded during continuous operations throughout STS-2, -3, -4, and -9. This report discusses the analysis techniques employed in reducing subsequent results, with an emphasis placed on particle size and velocity data. It also describes the operation of the overall experiment and some of the results obtained.

Clifton, K. Stuart↗

Preliminary study of niobium alloy contamination by transport through helium

Transport of gaseous contaminants through the working fluid to or from sensitive refractory alloys is theoretically possible during long time operation of Brayton and Stirling space power generation systems which use a gas as the working fluid. A test was designed which could give an answer to whether transport of contaminants through the working fluid was a potential major problem. The findings of that preliminary study are summarized.

Scheuermann, C. M.↗

Space station particulate contamination environment

The origin of particulate contamination on the Space Station will mostly be from pre-launch operations. The adherence and subsequent release of these particles during space flight are discussed. Particle size, release velocity, and release direction are important in determining particle behavior in the vicinity of the vehicle. The particulate environment at the principal science instrument locations is compared to the space shuttle bay environment. Recommendations for possibly decreasing the particulate contamination are presented.

Miller, E. R.↗

Optical contamination measurements on early Shuttle missions

Two camera/photometers were included as part of the Induced Environment Contamination Monitor on STS-2,-3,-4, and -9 orbital missions to record photographically Shuttle-induced particulate and background contamination. The cameras collected stereoscopic data continuously during the on-orbit phases of these missions making exposures every 150 s. The results recorded throughout a 32-deg field-of-view indicate high particle concentrations during early mission operations. These decay to a quiescent rate of 500 particles of greater than 10-micron radius observed per orbit. Preliminary size and velocity distributions of measured particles are presented as are measurements of background brightness due to unresolved particles in the visible spectral region.

Clifton, K. Stuart↗

AIS radiometry and the problem of contamination from mixed spectral orders

The spectral radiance of test areas under solar illumination is ascertained in view of Airborne Imaging Spectrometer (AIS) data from Mono Lake, CA, establishing an atmospheric correction method for major absorbers on the basis of the spectrometric data themselves. The apparent low contrast of all atmospheric absorption bands leads to a study of contamination from overlapping spectral orders in the AIS data; this contamination is found unambiguously above 1500 nm with a magnitude that is a factor of 1.5-2.0 greater than the expected uncontaminated signal alone.

Conel, J. E.↗

Infrared reflectance spectra of Na2S with contaminant Na2CO3 - Effects of adsorbed H2O and CO2 and relation to studies of Io

A previously reported laboratory determination of the IR spectrum of Na2S is presently noted to have been incorrectly interpreted, due to the inadvertent contamination of the sample with Na2CO3. New Na2S spectra are presented, and the Na2CO3 spectrum is examined in order to demonstrate that this phase is the primary sample contaminant. Na2S is a candidate surface component on the Jupiter satellite, Io, in view of its apparent high IR brightness and spectral neutrality in the 1-5 micron range.

Nash, Douglas B.↗

Self-contained space qualifiable optical contamination monitor

Experiments operating in the VUV as well as those employing cryocooled optical surfaces are the most seriously affected by spacecraft contamination due to outgassing of foreign materials, reaction byproducts of thruster firings, system venting emissions, etc. Attention is presently given to a self-contained optical contamination monitor, furnishing in-flight and/or real-time monitoring of VUV reflectivity and transmittance. The time-lining of measurement results with other spacecraft events will allow the direct evaluation of spacecraft operation effects on critical optical surfaces.

Jarratt, R. V., Jr.↗

Effects of water-contaminated air on blowoff limits of opposed jet hydrogen-air diffusion flames

The effects of water-contaminated air on the extinction and flame restoration of the central portion of N2-diluted H2 versus air counterflow diffusion flames are investigated using a coaxial tubular opposed jet burner. The results show that the replacement of N2 contaminant in air by water on a mole for mole basis decreases the maximum sustainable H2 mass flow, just prior to extinction, of the flame. This result contrasts strongly with the analogous substitution of water for N2 in a relatively hot premixed H2-O2-N2 flame, which was shown by Koroll and Mulpuru (1986) to lead to a significant, kinetically controlled increase in laminar burning velocity.

Pellett, Gerald L.↗

The effects of contamination on gaseous X-ray detectors

Results are presented which detail how the performance of a proportional counter degrades when oxygen is added as a contaminant. It is demonstrated that argon based gas fillings are much less sensitive to electronegative impurities than are xenon filled detectors which can show significant deterioration for contamination levels as low as 10 ppm. The data are particularly relevant to X-ray astronomy, where sealed systems must operate for long periods of time.

Ramsey, B. D.↗

Spectrograph Measures Contamination Of Optical Elements

Scanning-monochromator spectrograph designed to measure contamination on surfaces of optical elements as function of time. Repeatedly exposes samples to environment, then measures their transmittances or reflectances over range of wavelengths. Intended for use at vacuum-ultraviolet wavelengths to evaluate effects of outgassing, heating, and cooling on optical instruments. Principle of operation also applicable to spectral monitoring of time-dependent contamination at other wavelengths and in laboratory, industrial, or other settings.

Flint, Bruce K.↗

Contamination control requirements document JSC 30426 recommended updates

Contamination control requirements for the Space Station have been evolving over the last few years. Workshops, comments by experimenters and continuing analysis have resulted in recommending changes to the November 19, 1986 version of Space Station External Contamination Control Requirements, JSC 30426. These are summarized and presented, so that the requirements can be revised as soon as possible, to minimize costly design impacts on the Space Station.

Rantanen, Ray↗

The possible contamination of Jupiter

The Galileo probe, though at present its future is uncertain, would, if not sterilized, represent a good chance of contaminating Jupiter. Most scientists opposed to sterilizing the probe argue that to order the probe sterilized would be the death of the project, since sterilization would entail a reconstruction of the probe, and there are not enough funds to accomplish this. These scientists, however, are ignoring a relatively simple and inexpensive alternative to the traditional heat sterilization method. The main threat of contamination comes from Galileo's exterior surfaces: the shell of the probe and its parachute. The probe innermost components would not represent a threat since the probe is sealed. In light of the fact that only the exterior of Galileo would have to be sterilized, heat would not have to be used as a method of sterilization. Instead, various gas mixtures could be sprayed entirely over the probe and its parachute, gases which would kill any and all bacteria. This idea is more thoroughly examined.

Garcia, Joe↗

Contamination effects of GPS Navstar solar array performance

The solar arrays on Navstars 1 to 6 have been limiting the electrical power capabilities in the extended life (beyond the 5 year design life). The departure from predicted performance consists of an extra 2.5 percent per year degradation beyond the radiation model estimates. This degradation is unusual in showing a linear rather than exponential decay with time. The performance of the arrays on these satellites has been examined in order to predict future behavior and to make refined projections on the Navstar 7 to 11 solar arrays. Evidence obtained from flight experiments on Navstar 5 and 6, and from laboratory experiments, suggests that contamination of the solar arrays while on orbit may be responsible. The evidence for photo-induced contamination of spacecraft surfaces is presented, and the effect on solar array output in the case of the GPS satellites is shown to be consistent with the observed anomalies.

Marvin, Dean C.↗