Ultrasonic modulus determination in composite media

A nondestructive test procedure for determining the elastic properties of anisotropic media is presented. The technique is based on transit time measurements for multiple angles of incidence and a numerical solution of the resulting coupled nonlinear equations for modulus determination. Methods for compensating for energy flux deviation from the wave normal and the resulting differences group and phase velocity are devised.

Kline, R. A.↗

An evaluation of flight path management automation in transport category aircraft

A desk-top simulation of a Boeing 757/767 Electronic Flight Instrumentation System (EFIS) and Control Display Unit (CDU) was used in an experiment to compare three modes of communication for the clearance amendment process: standard voice procedures, a textual delivery method, and a graphical delivery method. Eight qualified Boeing 757/767 pilots served as subjects. Each flew nine landing scenarios with three amendments given in each scenario. Both acceptable and unacceptable clearance amendments were presented in order to assess situational awareness. Times for comprehension and execution of the amendment were recorded along with workload ratings, responses to unacceptable amendments, and subjective impressions. The graphical mode was found to be superior in terms of the time measures and subjective ratings. No difference was found between the modes in the ability to detect unacceptable clearances.

Chandra, D.↗

Changes in renal function and fluid and electrolyte regulation in space flight

The cephalad fluid redistribution resulting from weightlessness has a number of physiologic consequences. Plasma volume is reduced soon after weightlessness is reached, and red blood cell mass reduction follows. Plasma atrial natriuretic peptide, which inhibits aldosterone secretion, was elevated during space flight while plasma aldosterone was below preflight levels. Serum sodium was also reduced and potassium was elevated. Antidiuretic hormone (ADH) was markedly elevated at almost all measurement times in the first eight days of flight, but plasma volume did not return to preflight levels.

Leach, C. S.↗

SO2 on Venus: A final cross-calibration with Pioneer Venus

In the present reporting period we have met with the Pioneer Venus PI to collaborate on the recalibration of the UV spectrometer of Pioneer Venus. The associated data reduction and analysis activities have been completed. The sensitivity of the UV spectrometer has been steadily declining since orbit insertion of Pioneer Venus in 1978 due to aging of the detector tubes. The sensitivity decline is a strong function of wavelength and the rate of decline is also a function of time. Measures were taken to reduce the light dose received by the instrument to slow down the sensitivity decline. The stellar calibration using the bright UV star Hadar in 1990 indicates that the sensitivity decline may have slowed down more than have been previously estimated. The derived amount of SO2 from Pioneer Venus depends on the accuracy of the absolute sensitivity of the UV spectrometer. The previous cross calibration between IUE and Pioneer Venus led to the use of the same solar flux data for reducing and modelling data from both IUE and Pioneer Venus. The comparison between the 1991 IUE results and the Pioneer Venus stellar calibration carried out in 1990 will allow a more accurate determination of sensitivity decline of the PV UV spectrometer. The result of this comparison will be crucial in determining the trend of SO2 in the Venus atmosphere.

Stern, S. Alan↗

A powerful local shear instability in weakly magnetized disks. III - Long-term evolution in a shearing sheet. IV - Nonaxisymmetric perturbations

The nonlinear evolution of the recently identified accretion disk magnetic shear instability is investigated through a series of numerical simulations. Finite-difference computations of the equations of compressible MHD are carried out on an axisymmetric shearing sheet system with periodic boundary conditions designed to approximate a local region within an accretion disk. Initial field configurations that include some net vertical component evolve into a nonlinear, exponentially growing solution with large poloidal velocities and magnetic fields with energies comparable to the thermal energy density. The stability of a purely azimuthal field configuration is examined, and it is found that nonaxisymmetric instability is present, but with a growth time measured in tens of orbital periods. In general, the most rapid growth occurs for very small radial and azimuthal wavenumbers, leading to coherent magnetic field structure in planes parallel to the disk. It is suggested that this instability is a key ingredient for the generation of magnetic fields in disks.

Hawley, John F.↗

Lidar for expendable launch vehicles

A lidar wind measurement system is described which can be used as an alternative to the current Jimsphere/Rawinsonde method. The decrease in wind measurement time provides significant benefits to launch vehicle operations. The faster acquisition time associated with the lidar system provides better estimates of wind persistency and gust prediction.

Lee, Michael S.↗

Thin film diamond temperature sensor array for harsh aerospace environment

The feasibility of using polycrystalline CVD diamond films as temperature sensors in harsh aerospace environment associated with hypersonic flights was tested using patterned diamond resistors, fabricated on flat or curved oxidized Si surfaces, as temperature sensors at temperatures between 20 and 1000 C. In this temperature range, the measured resistance was found to vary over 3 orders of magnitude and the temperature coefficient of resistance to change from 0.017/K to 0.003/K. After an annealing treatment, the resistance change was reproducible within 1 percent on the entire temperature range for short measuring times.

Aslam, M.↗

Solid state neutron dosimeter for space applications

One of the most important contributions to the radiation exposure of astronauts engaged in space flight is the significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Under NASA sponsorship, we are developing a solid state neutron sensor capable of being incorporated into a very compact, flight instrument to provide high quality real time measurement of this important radiation flux. The dosimeter uses a special, high neutron sensitivity, PIN diode that is insensitive to the other forms of ionizing radiation. The dosimeter will have the ability to measure and record neutron dose over a range of 50 microgray to tens of milligrays (5 millirads to several rads) over a flight of up to 30 days. The performance characteristics of the PIN diode with a detailed description of the overall dosimeter is presented.

Nagarkar, V.↗

Pressure dependence of the electro-optic response function in partially exposed polymer dispersed ferroelectric liquid crystals

Ferroelectric liquid crystals in a new configuration, termed partially exposed polymer dispersed ferroelectric liquid crystal (PEPDFLC), respond to external pressures and demonstrate pressure-induced electro-optic switching response. When the PEPDFLC thin film is sandwiched between two transparent conducting electrodes, one a glass plate and the other a flexible sheet such as polyvenylidene fluoride, the switching characteristics of the thin film are a function of the pressure applied to the flexible transparent electrode and the bias voltage across the electrodes. Response time measurements reveal a linear dependence of the change in electric field with external pressure.

Parmar, D. S.↗

Measuring Frequency Instability Of A Large Antenna

Frequency instability of antenna under test determined from measurement of phase deviation between outputs of two antennas. Fiber-optic system used to minimize spurious component of frequency instability contributed by propagation of signal from reference antenna to Allan-variance-measuring instrument. Intended primarily to reveal contributions of wind and air-temperature effects on antenna and beam-waveguide structures to overall frequency instabilities of received signals. Technique simpler, less expensive, potentially capable of providing instability data in shorter measuring times, and more precise.

Otoshi, Tom Y.↗

Investigation of advanced fault insertion and simulator methods

The cooperative agreement partly supported research leading to the open-literature publication cited. Additional efforts under the agreement included research into fault modeling of semiconductor devices. Results of this research are presented in this report which is summarized in the following paragraphs. As a result of the cited research, it appears that semiconductor failure mechanism data is abundant but of little use in developing pin-level device models. Failure mode data on the other hand does exist but is too sparse to be of any statistical use in developing fault models. What is significant in the failure mode data is that, unlike classical logic, MSI and LSI devices do exhibit more than 'stuck-at' and open/short failure modes. Specifically they are dominated by parametric failures and functional anomalies that can include intermittent faults and multiple-pin failures. The report discusses methods of developing composite pin-level models based on extrapolation of semiconductor device failure mechanisms, failure modes, results of temperature stress testing and functional modeling. Limitations of this model particularly with regard to determination of fault detection coverage and latency time measurement are discussed. Indicated research directions are presented.

Dunn, W. R.↗

Analysis of DE-1 PWI electric field data

The measurement of low frequency electric field oscillations may be accomplished with the Plasma Wave Instrument (PWI) on DE 1. Oscillations at a frequency around 1 Hz are below the range of the conventional plasma wave receivers, but they can be detected by using a special processing of the quasi-static electric field data. With this processing it is also possible to determine if the electric field oscillations are predominately parallel or perpendicular to the ambient magnetic field. The quasi-static electric field in the DE 1 spin/orbit plane is measured with a long-wire 'double probe'. This antenna is perpendicular to the satellite spin axis, which in turn is approximately perpendicular to the geomagnetic field in the polar magnetosphere. The electric field data are digitally sampled at a frequency of 16 Hz. The measured electric field signal, which has had phase reversals introduced by the rotating antenna, is multiplied by the sine of the rotation angle between the antenna and the magnetic field. This is called the 'perpendicular' signal. The measured time series is also multiplied with the cosine of the angle to produce a separate 'parallel' signal. These two separate time series are then processed to determine the frequency power spectrum.

Weimer, Daniel↗

Space simulation techniques and facilities for SAX STM test campaign

SAX is a satellite for X-Ray astronomy. It is a major element of the overall basic Science Program of the Italian Space Agency (ASI) and is being developed with the contribution of the Netherlands Agency for Aerospace Programs (NIVR). The scientific objectives of SAX are to carry out systematic and comprehensive observations of celestial X-Ray sources over the 0.1 - 300 KeV energy range with special emphasis on spectral and timing measurements. The satellite will also monitor the X-Ray sky to investigate long-term source variability and to permit localization and study of X-Ray transients. Alenia Spazio is developing the satellite that is intended for launch in the second half of 1995 in a low, near-equatorial Earth orbit. At system level a Structural Thermal Model (STM) has been conceived to verify the environmental requirements by validating the mechanical and thermal analytical models and qualifying satellite structure and thermal control. In particular, the following tests have been carried out in Alenia Spazio, CEA/CESTA and ESTEC facilities: Modal Survey, Centrifuge, Acoustic, Sinusoidal/Random Vibration and Thermal Balance. The paper, after a short introduction of the SAX satellite, summarizes the environmental qualification program performed on the SAX STM. It presents test objectives, methodologies and relevant test configurations. Peculiar aspects of the test campaign are highlighted. Problems encountered and solutions adopted in performing the tests are described as well. Furthermore, test results are presented and assessed.

Giordano, Pietro↗

Effects of weightlessness on human baroreflex function

Impaired cardiovascular function, characterized by orthostatic intolerance and reduced exercise capacity, is a result of space travel. We hypothesized that postflight baroreflex dysfunction may contribute. We studied the vagally mediated carotid baroreceptor-cardiac reflex response of 6 astronauts before, during, and after the ten day SLS-l mission. A series of R-waves triggered pressure and suction steps (from 40 to minus 65 mmHg) were delivered to a neck chamber during held expirtation. Resulting R-R interval changes were plotted against carotid distending pressure (systolic - neck pressure), and curve parameters calculated. After an initial rise, the operational point declined consistently during the flight and reached a nadir on landing day, but had recovered to preflight levels by L + 4. Slope and range of the response declined throughout the flight, were slightly recovered by the time measurements were made on landing day, but still were reduced on L + 4. These data indicate that space flight results in a significant impairment of the carotid baroreceptor cardiac reflex response.

Fritsch, Janice M.↗

Advanced technologies in the ASI MLRO towards a new generation laser ranging system

Matera Laser Ranging Observatory (MLRO) is a high performance, highly automated optical and astronomical observatory currently under design and development by AlliedSignal for the Italian Space Agency (ASI). It is projected to become operational at the Centro Geodesia Spaziale in Matera, Italy, in 1997. MLRO, based on a 1.5-meter astronomical quality telescope, will perform ranging to spacecraft in earthbound orbits, lunar reflectors, and specially equipped deep space missions. The primary emphasis during design is to incorporate state-of-the-art technologies to produce an intelligent, automated, high accuracy ranging system that will mimic the characteristic features of a fifth generation laser ranging system. The telescope has multiple ports and foci to support future experiments in the areas of laser communications, lidar, astrometry, etc. The key features providing state-of-the-art ranging performance include: a diode-pumped picosecond (50 ps) laser, high speed (3-5 GHz) optoelectronic detection and signal processing, and a high accuracy (6 ps) high resolution (less than 2 ps) time measurement capability. The above combination of technologies is expected to yield millimeter laser ranging precision and accuracy on targets up to 300,000 km, surpassing the best operational instrument performance to date by a factor of five or more. Distributed processing and control using a state-of-the-art computing environment provides the framework for efficient operation, system optimization, and diagnostics. A computationally intelligent environment permits optimal planning, scheduling, tracking, and data processing. It also supports remote access, monitor, and control for joint experiments with other observatories.

Varghese, Thomas↗

European plans for new clocks in space

An outline of the future European space research program where precise clocks are necessary is presented, pointing out how space applications are posing impressive requirements as regards clock mass, power, ruggedness, long life, accuracy and, in some cases, spectral purity. The material presented was gathered in some laboratories; useful information was obtained from the Space Agencies of France (CNES), Germany (DARA) and Italy (ASI), but the bulk is coming from a recent exercise promoted inside ESA (the European Space Agency) and aimed to prefigure space research activities at the beginning of the next millennium. This exercise was called Horizon 2000 plus; the outcomings were summarized in two reports, presented by ESA in may 1994. Precise clocks and time measurements are needed not only for deep-space or out-ward space missions, but are essential tools also for Earth oriented activities. In this latter field, the European views and needs were discussed in October 1994, in a meeting organized by ESA and devoted to Earth Observation problems. By a scrutiny of these reports, an analysis was performed on the missions requiring a precise clock on board and the driving requirements were pointed out, leading to a survey of the necessary PTTI developments that, to some extent, are in the realm of possibility but that pose serious challenges. In this report the use of frequency standards in the satellite navigation systems is not considered.

Leschiutta, Sigfrido M.↗

Particle simulation on heterogeneous distributed supercomputers

We describe the implementation and performance of a three dimensional particle simulation distributed between a Thinking Machines CM-2 and a Cray Y-MP. These are connected by a combination of two high-speed networks: a high-performance parallel interface (HIPPI) and an optical network (UltraNet). This is the first application to use this configuration at NASA Ames Research Center. We describe our experience implementing and using the application and report the results of several timing measurements. We show that the distribution of applications across disparate supercomputing platforms is feasible and has reasonable performance. In addition, several practical aspects of the computing environment are discussed.

Becker, Jeffrey C.↗

Improved Raman-Scattering Gas-Species Monitor

Improved Raman-scattering instrument provides real-time measurements of concentration of gas species of interest mixed with other gases. High efficiency achieved by multiple passes of laser beam, fast collection optics. Costs less, weighs less, and operates more easily. In original application, instrument used to determine whether flammable or explosive concentration of leaking hydrogen present in atmosphere that contains varying concentrations of helium, air, and possibly other gases in addition to hydrogen.

Adler-Golden, Steven↗