Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optimal Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Framework for Multi Layer Control in Python (FMLC) v1.0

This package is developed as a backend for multi-layer and multi-time domain controller. One example are controller based on [Model Predictive Control] (MPC) where different modules with different time constants have to be coordinated to allow optimal control. In a simple example, the Weather Forecast must be acquired and processed, the MPC is computed, and finally the control is applied. All these modules typically run on the same time step (Time step: 5 minutes), but are different instances within the framework. The framework allows parallelization using the `multiprocessing` module. However, another real-time controller (Time step: 1 second) must be applied to react on instant system disturbances beyond the MPC time step. Last, a supervisory MPC controller (Time step: 1 hour) might be added to ensure global optimality.

Gehbauer, Christoph↗

Mode Selective Excitation Using Coherent Control Spectroscopy

Femtosecond time-resolved coherent anti-Stokes Raman scattering (fs-CARS) gives access to ultrafast molecular dynamics. However, femtosecond laser pulses are spectrally broad and therefore coherently excite several molecular modes. While the temporal resolution is high, usually no mode-selective excitation is possible. This paper demonstrates the feasibility of selectively exciting specific molecular vibrations in solution phase with shaped fs laser excitation using a feedback-controlled optimization technique guided by an evolutionary algorithm. This approach is also used to obtain molecule-specific CARS spectra from a mixture of different substances. The optimized phase structures of the fs pulses are characterized to get insight into the control process. Possible applications of the spectrum control are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Developing an Energy-Conscious Traffic Signal Control System for Optimized Fuel Consumption in Connected Vehicle Environments

The project titled “Developing an Energy-Conscious Traffic Signal Control System for Optimized Fuel Consumption in Connected Vehicle Environments” addresses energy-related challenges associated with adaptive traffic control systems by integrating connected vehicles (CV) and connected infrastructure (CI). The system developed in this project, a CV-based adaptive traffic control system, aims to improve fuel consumption in mixed traffic environments by capitalizing on emerging CV and CI communication technologies, as well as leveraging recent advances in Artificial Intelligence (AI), optimization, and edge computing. The system was tested at the MLK Smart Corridor, an urban testbed managed by the University of Tennessee at Chattanooga (UTC) and the City of Chattanooga. The system was validated through extensive simulations, both Software-in-the-Loop (SILS) and Hardware-in-the-Loop (HILS), and was further implemented and tested in real-world conditions at several intersections along the corridor. The Fuel Consumption Performance Index (FC-PI) and the Ecological Performance Index (Eco-PI) were developed as the key components for evaluating the system’s impact on fuel consumption and emissions. These metrics provided a comprehensive means of understanding the impact of traffic signal control optimization in mixed traffic environments. The report presents an in-depth analysis of the Eco-PI, FC-PI, adaptive traffic control system integration, and the testing and field implementation of the system. The results demonstrate significant reductions in fuel consumption and emissions, showcasing the system’s capability to contribute to more sustainable urban traffic management. The report also documents the challenges encountered and recommendations for scaling and further improving the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving convergence of the Matrix Power Control Algorithm for random vibration testing

Herein, this paper describes modifications to the Matrix Power Control Algorithm (MPCA) to improve convergence for Random Vibration Control (RVC) testing. In particular, this paper presents Multiple-Input Multiple-Output (MIMO) implementations of MPCA in simulation and experiment. An Euler–Bernoulli beam model was simulated with applied base excitations and the Box Assembly with Removable Component (BARC) was used in experiment to validate results. The Bayesian optimization package Dragonfly was used to optimize control parameters. Additionally, a moving-average was employed and optimized to improve the measured response feedback for MPCA, reduce the number of averages needed to be taken between control updates, and further improve convergence. The key results of this paper show that the performance of MPCA can be improved by tuning the control parameters and by applying an optimized moving-average. Furthermore, it is demonstrated that convergence can be achieved within 12 drive-frames, which greatly enhances vibration control capability.

42 ENGINEERING↗

Balancing Power Absorption Against Structural Loads With Viscous Drag and Power-Takeoff Efficiency Considerations

The focus of this paper is to balance power absorption against structural loading for a novel fixed-bottom oscillating surge wave energy converter in both regular and irregular wave environments. The power-to-load ratio will be evaluated using pseudospectral control (PSC) to determine the optimum power-takeoff (PTO) torque based on a multiterm objective function. This paper extends the pseudospectral optimal control problem to not just maximize the time-averaged absorbed power but also include measures for the surge-foundation force and PTO torque in the optimization. The objective function may now potentially include three competing terms that the optimizer must balance. Separate weighting factors are attached to the surge-foundation force and PTO control torque that can be used to tune the optimizer performance to emphasize either power absorption or load shedding. To correct the pitch equation of motion, derived from linear hydrodynamic theory, a quadratic-viscous-drag torque has been included in the system dynamics; however, to continue the use of quadratic programming solvers, an iteratively obtained linearized drag coefficient was utilized that provided good accuracy in the predicted pitch motion. Furthermore, the analysis considers the use of a nonideal PTO unit to more accurately evaluate controller performance. The PTO efficiency is not directly included in the objective function but rather the weighting factors are utilized to limit the PTO torque amplitudes, thereby reducing the losses resulting from the bidirectional energy flow through a nonideal PTO. Furthermore, results from PSC show that shedding a portion of the available wave energy can lead to greater reductions in structural loads, peak-to-average power ratio, and reactive power requirement.

16 TIDAL AND WAVE POWER↗

Power-to-load balancing for asymmetric heave wave energy converters with nonideal power take-off

The aim of this study is to maximize the power-to-load ratio for asymmetric heave wave energy converters. Linear hydrodynamic theory was used to calculate bounds of the expected time-averaged power (TAP) and corresponding surge-restraining force, pitch-restraining torque, and power take-off (PTO) control force with the assumption of sinusoidal displacement. This paper formulates an optimal control problem to handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads in regular and irregular waves. Penalty weights are placed on the surge-restraining force, pitch-restraining torque, and PTO actuation force, thereby allowing the control focus to concentrate on either power absorption or load mitigation. The penalty weights are used to control peak structural and actuator loads that were found to curb the additional losses in power absorption associated with a nonideal PTO. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results for 'The Berkeley Wedge' in the form of output TAP, reactive TAP needed to drive WEC motion, and the amplitudes of the surge-restraining force, pitch-restraining torque, and PTO control force are shown.

16 TIDAL AND WAVE POWER↗

Optimal shielding design for minimum materials cost or mass

The mathematical underpinnings of cost optimal radiation shielding designs based on an extension of optimal control theory are presented, a heuristic algorithm to iteratively solve the resulting optimal design equations is suggested, and computational results for a simple test case are discussed. A typical radiation shielding design problem can have infinitely many solutions, all satisfying the problem's specified set of radiation attenuation requirements. Each such design has its own total materials cost. For a design to be optimal, no admissible change in its deployment of shielding materials can result in a lower cost. This applies in particular to very small changes, which can be restated using the calculus of variations as the Euler-Lagrange equations. Furthermore, the associated Hamiltonian function and application of Pontryagin's theorem lead to conditions for a shield to be optimal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictive Scheduling for Electric Vehicles Considering Uncertainty of Load and User Behaviors

Un-coordinated Electric Vehicle (EV) charging can create unexpected load in local distribution grid, which may degrade the power quality and system reliability. The uncertainty of EV load, user behaviors and other baseload in distribution grid, is one of challenges that impedes optimal control for EV charging problem. Previous researches did not fully solve this problem due to lack of real-world EV charging data and proper stochastic model to describe these behaviors. In this paper, we propose a new predictive EV scheduling algorithm (PESA) inspired by Model Predictive Control (MPC), which includes a dynamic load estimation module and a predictive optimization module. The user-related EV load and base load are dynamically estimated based on the historical data. At each time interval, the predictive optimization program will be computed for optimal schedules given the estimated parameters. Only the first element from the algorithm outputs will be implemented according to MPC paradigm. Current-multiplexing function in each Electric Vehicle Supply Equipment (EVSE) is considered and accordingly a virtual load is modeled to handle the uncertainties of future EV energy demands. This system is validated by the real-world EV charging data collected on UCLA campus and the experimental results indicate that our proposed model not only reduces load variation up to 40% but also maintains a high level of robustness. Finally, IEC 61850 standard is utilized to standardize the data models involved, which brings significance to more reliable and large-scale implementation.

Wang, Bin↗

Lower and upper threshold limit for artificial neural network based chilled and condenser water temperatures set-point control in a chilled water system

In this study, an ANN (artificial neural network) based real-time optimized control algorithm for a chilled water cooling system was developed and applied in an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, the cooling tower’s CndWT (condenser water temperature) and the chiller’s ChWT (chilled water temperature) were set as system control variables. To evaluate algorithm performance, the electric consumption and the COP (coefficient of performance) were compared and analyzed when ChWT and CndWTs were controlled conventionally and controlled based on the ANN. During the analysis, unexpected abnormal data was observed due to insufficient training data and limited consideration of OWBT (outdoor air wet-bulb temperature) when determining the CndWT set-point. Therefore, it is necessary to further build training data from a wider range of conditions and to set the lower limit of CndWT set-point to at least +3.6 °C above OWBT when the OWBT is higher than 23 °C, so that further energy savings can be achieved.

42 ENGINEERING↗

Harnessing deep reinforcement learning to construct time-dependent optimal fields for quantum control dynamics

Here, we present an efficient deep reinforcement learning (DRL) approach to automatically construct time-dependent optimal control fields that enable desired transitions in dynamical chemical systems. Our DRL approach gives impressive performance in constructing optimal control fields, even for cases that are difficult to converge with existing gradient-based approaches. We provide a detailed description of the algorithms and hyperparameters as well as performance metrics for our DRL-based approach. Our results demonstrate that DRL can be employed as an effective artificial intelligence approach to efficiently and autonomously design control fields in quantum dynamical chemical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Building thermal model development of typical house in U.S. for virtual storage control of aggregated building loads based on limited available information

A building thermal model is an essential component for achieving optimal control of a building’s heating, ventilation, and air conditioning (HVAC). A self-learning grey-box model has been developed by implementing data-driven techniques and utilizing limited available information about the building. In previous research, detailed foreknown knowledge/information, e.g. physical and thermal properties of building materials, as well as sufficient number of observation points, e.g. indoor temperature sensors in different zones, are available for making the decision of model structure and parameters searching range easier. The availability of measured data and a narrowed searching range of model parameters, e.g. resistance and capacity for each wall, made the adopted algorithms quickly achieve near optimal values, which closely approximate the actual heat transfer of a building. Meanwhile, the details of pre-processing of the key inputs were seldom explained. Compared to the previous research, in this study, the available information is assumed to be limited which can fill the requirement for large scale virtual storage control of real residential community in near future, where it may be impractically or over time-consuming to acquire the detailed information for each single house. The developed model is validated by comparing the results to measured data in a recently-built home typical of the southeastern United States.

Cui, Borui↗

Toward real-time optimization through model reduction and model discrepancy sensitivities

Optimization problems arise in a range of scenarios, from optimal control to model parameter estimation. In many applications, such as the development of digital twins, it is essential to solve these optimization problems within wall-clock-time limitations. However, this is often unattainable for complex systems, such as those modeled by nonlinear partial differential equations. One strategy for mitigating this issue is to construct a reduced-order model (ROM) that enables more rapid optimization. In particular, the use of nonintrusive ROMs—those that do not require access to the full-order model at evaluation time—is popular because they facilitate the computation of optimization solutions within the wall-clock time requirements. However, the optimization solution will be unreliable if the iterates move outside the ROM training data. This article proposes the use of hyper-differential sensitivity analysis with respect to model discrepancy (HDSA-MD) as a computationally efficient tool to augment ROM-constrained optimization and improve its reliability. The proposed approach consists of two phases: (i) an offline phase where several full-order model evaluations are computed to train the ROM, and (ii) an online phase where a ROM-constrained optimization problem is solved, a limited number of full-order model evaluations are computed, and HDSA-MD is used to enhance the optimization solution. Numerical results are demonstrated for two examples, atmospheric contaminant control and wildfire ignition location estimation, in which a ROM is trained offline using inaccurate atmospheric data. In conclusion, the HDSA-MD update yields a significant improvement in the ROM-constrained optimization solution using only one full-order model evaluation online with corrected atmospheric data.

PDE-constrained optimization↗

Metal-organic framework supported single-site nickel catalysts for butene dimerization

Homotopic sites in a well-controlled environment are not only ideal systems for mechanistic studies, but also allow optimal control of catalytic transformations. Sites having only a single metal cation and sites consisting of metal oxo complexes with few nickel (Ni) cations supported on the nodes of UiO-66 metal-organic framework (Ni-UiO-66) are studied for 1-butene dimerization. Monomeric Ni sites, which bind to the Zr 6 node via two Zr-OH(µ3) linkages, are active and selective for the dimerization of 1-butene to linear and mono-branched C 8 isomers. Ni oxo complexes with few Ni cations show lower activity and promote the oligomerization of transiently formed C 8 isomers. In conclusion, Kohn-Sham density function theory calculations combined with spectroscopic measurements and kinetic analyses indicate that dimerization follows a Cossee-Arlman reaction mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

beluga

beluga is an open-source optimal control software that uses publicly available, indirect methods from GitHub. beluga's indirect optimization engine has been reworked to follow a lazy functional paradigm. This improves the software's flexibility and enables users to create their own optimization processes without modification of the source code. beluga is general-purpose and therefore very broad in scope and application. SAND2020-12847 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Sparapany, Michael↗

Validation of HVAC Hardware-in-the-Loop Simulation for Advanced Control Strategies in Smart Homes: Preprint

Residences with smart thermostats can use advanced control strategies to manage their cooling/heating demand, but it is difficult to evaluate optimal control strategies for flexible heating, ventilation, and air conditioning (HVAC) systems in a traditional laboratory setting. The HVAC hardware-in-the-loop (HIL) system combines physical HVAC equipment and a physical thermostat with a simulated house to enable realistic operation of the hardware in any climate. This HIL platform allows researchers to evaluate advanced control strategies for homes with different construction or vintage types, as well as different climates and occupancy schedules. To demonstrate the capabilities of the HVAC HIL system, experimental results with a SEER 16, HSPF 9.5, 3 ton single-speed air source heat pump are validated against past field data collected from a heavily instrumented, unoccupied, retrofit house located in Sacramento, California. Three different cooling strategies are recreated in the HVAC HIL platform, including two different pre-cooling schedules that were designed to shift energy use away from the evening peak. The room temperatures, heat pump energy use, and run time show good agreement between the field data and HIL experimental results for three strategies.

cooling strategies↗

A Pulse Generation Framework with Augmented Program-aware Basis Gates and Criticality Analysis

Near-term intermediate scale quantum (NISQ) de- vices are subject to considerable noise and short coherence time. Consequently, it is critical to minimize circuit execution latency. Traditionally, each basis gate of a transpiled circuit is decoded into a fixed episode of the device control pulses. Recently, people started to investigate merged pulse generation for customized gates through quantum optimal control (QOC). However, existing QOC approaches face the challenges of (i) restricted search space due to prohibitive compilation overhead; (ii) suboptimal end-to-end performance due to aggressive local optimization and falsely introduced dependency among the customized gates; (iii) inadequate adaptivity towards system calibration, which is critical for NISQ devices. In this work, we propose PAQOC, a novel QOC framework that can (i) automatically detect frequently encountered gate patterns in the logical circuit by modeling the problem as a subgraph mining process and reuse these patterns to enable much larger search space exploration (i.e., program aware); (ii) systemically construct customized gate-set based on the impact to the overall program latency (i.e., criticality-aware); and (iii) quickly adapt to system re-calibration thanks to the small-scale pattern-based gate generation (i.e., adaptivity-aware). PAQOC achieves a good tradeoff between circuit performance and compilation time, allowing fully automatic, single stop, ad- hoc customized pulse generation for more efficient execution of user programs on NISQ devices. Evaluations using fifteen applications show that PAQOC can achieve on average 1.95× speedup of the circuit latency and achieve on average 36.7% reduction in compilation overhead. With PAQOC, circuits can run faster with reduced noise, allowing deeper circuits to be tested within the coherence time of present NISQ platforms.

Chen, Yanhao↗

Neural network accelerator for quantum control

Efficient quantum control is necessary for practical quantum computing implementations with current technologies. Conventional algorithms for determining optimal control parameters are computationally expensive, largely excluding them from use outside of the simulation. Existing hardware solutions structured as lookup tables are imprecise and costly. By designing a machine learning model to approximate the results of traditional tools, a more efficient method can be produced. Such a model can then be synthesized into a hardware accelerator for use in quantum systems. In this study, we demonstrate a machine learning algorithm for predicting optimal pulse parameters. This algorithm is lightweight enough to fit on a low-resource FPGA and perform inference with a latency of 175 ns and pipeline interval of 5 ns with > 0.99 gate fidelity. In the long term, such an accelerator could be used near quantum computing hardware where traditional computers cannot operate, enabling quantum control at a reasonable cost at low latencies without incurring large data bandwidths outside of the cryogenic environment.

43 PARTICLE ACCELERATORS↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗