Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2021 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2021, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 1,400 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 90% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (676 GW) and battery storage (~420 GW) are – by far – the fastest growing resources in the queues; combined they accounted for nearly 85% of new capacity entering the queues in 2021. Substantial wind (247 GW) capacity is also seeking interconnection, 31% of which is for offshore projects (77 GW). In total, about 930 GW of zero-carbon generating capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 286 GW of solar hybrids (primarily solar+battery) and 19 GW of wind hybrids are currently active in the queues; nearly half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 23% of the projects seeking connection from 2000 to 2016 have subsequently been built. Completion percentages appear to be declining and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: for the regions with available data, the typical duration from connection request to commercial operation increased from ~2.1 years for projects built in 2000-2010 to ~3.7 years for those built in 2011-2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating Benefits and Challenges of Converting Retiring Coal Plants into Nuclear Plants

A coal-to-nuclear (C2N) transition means siting a nuclear reactor at the site of a recently retired coal power plant. Three overarching questions from the C2N transition guide this research: where in the United States are retired coal facilities located and what factors make a site feasible for transition; what factors of technology, cost, and project timeline drive investor economics over such a decision; and how will C2N impact local communities? The study team evaluated the siting characteristics of recently retired plants and those operating coal-fired power plant sites run by a utility or an independent power producer utilizing publicly available data to screen U.S. coal power plant sites to nuclear-feasible locations. After screening all retired coal sites to a set of 157 potential candidates and screening operating sites to a set of 237 candidates, the study team estimates that 80% of retired and operating coal power plant sites that were evaluated have the basic characteristics needed to be considered amenable to host an advanced nuclear reactor. For the recently retired plant sites evaluated, this represents a capacity potential of 64.8 GWe to be backfit at 125 sites. For the operating plant sites evaluated, this represents a capacity potential of 198.5 GWe to be backfit at 190 sites. This report evaluates a case study for the detailed impacts and potential outcomes from a C2N transition. Based on the nuclear technology choices and sizes evaluated to replace a large coal plant of 1,200 MWe generation capacity at the case study site, nuclear overnight costs of capital could decrease by 15% to 35% when compared to a greenfield construction project, through the reuse of infrastructure from the coal facility. Nuclear replacement designs can have a lower capacity size because nuclear power plants run at higher capacity factors than coal power plants. In the case study replacing coal capacity with 924 GWe of nuclear capacity, the study team found regional economic activity could increase by as much as $\$275 million$ and add 650 new, permanent jobs to the region of analysis. The evaluated site choice in the report is hypothetical for analysis purposes only and based on available data and documented assumptions. Consequently, the findings only inform at a general level. A community, investor, or other interested stakeholder can use these results to set up a detailed, in-depth analysis for a specific application of interest, such as evaluating a C2N transition of a specific coal power plant and a specific nuclear technology design. The report was subjected to independent peer reviews by experts in systems engineering and regional economic modeling to evaluate analysis and assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utility-Scale Solar, 2023 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2023 Edition” presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC (PV plants of 5 MWAC or less, including residential rooftop systems, are covered separately in Berkeley Lab’s companion annual report, Tracking the Sun). Highlights of this year’s update include: -10.4 GWAC of new utility-scale PV capacity came online in 2022, bringing cumulative installed capacity to more than 61.7 GWAC across 46 states. -94% of all new utility-scale PV capacity added in 2022 uses single-axis tracking. -Median installed project costs declined to $\$1.32$/WAC (or $\$1.07$/WDC) in 2022. -Plant-level capacity factors vary widely, from 9% to 35% (on an AC basis), with a sample median of 24%. The report explores drivers of this variation. -Utility-scale PV’s LCOE fell to $\$39$/MWh in 2022 ($\$29$/MWh if factoring in the federal investment tax credit, or ITC). -PPA prices have largely followed the decline in solar’s LCOE over time, but have recently stagnated and even moved slightly higher. Prices from a sample of recent contracts average around $\$20-30$/MWh (levelized) in the West and $\$30-40$/MWh elsewhere in the continental US. -In 2022, solar’s average market value (defined in the report to include only energy and capacity value) rose by 40% to $\$71$/MWh and exceeded average wholesale prices in 4 of the 7 ISOs/RTOs and 11 of 18 other balancing authorities analyzed. -Adding battery storage is one way to increase the value of solar. Our public data file tracks metadata and PPA prices from ~100 PV+battery hybrid projects that are already online or that have secured offtake arrangements. -the end of 2022, there were at least 947 GW of utility-scale solar power capacity within the interconnection queues across the nation, 456 GW of which include batteries. For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrospun Si and Si/C Fiber Anodes for Li-Ion Batteries

Due to structural changes in silicon during lithiation/delithiation, most Li-ion battery anodes containing silicon show rapid gravimetric capacity fade upon charge/discharge cycling. Herein, we report on a new Si powder anode in the form of electrospun fibers with only poly(acrylic acid) (PAA) binder and no electrically conductive carbon. The performance of this anode was contrasted to a fiber mat composed of Si powder, PAA binder, and a small amount of carbon powder. Fiber mat electrodes were evaluated in half-cells with a Li metal counter/reference electrode. Without the addition of conductive carbon, a stable capacity of about 1500 mAh/g (normalized to the total weight of the anode) was obtained at 1C for 50 charge/discharge cycles when the areal loading of silicon was 0.30 mgSi/cm2, whereas a capacity of 800 mAh/g was obtained when the Si loading was increased to ~1.0 mgSi/cm2. On a Si weight basis, these capacities correspond to >3500 mAh/gSi. The capacities were significantly higher than those found with a slurry-cast powdered Si anode with PAA binder. There was no change in fiber anode performance (gravimetric capacity and constant capacity with cycling) when a small amount of electrically conductive carbon was added to the electrospun fiber anodes when the Si loading was ≤1.0 mgSi/cm2.

Mondal, Abhishek N.↗

Understanding Economic and Deployment Benefits of Wind-PV Hybrid Power Plants

The least-cost approach to decarbonizing the U.S. electricity supply will likely involve a significantly expanded share of variable renewable energy (VRE) generation. Many strategies and approaches have been identified to address integration challenges in a VRE-dominated system, including standalone and coupled battery systems. In this study, we explored the current and future potential of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Analysis results include temporal complementarity of wind and PV resources across the contiguous United States, with an emphasis on metrics that quantify reductions in variability that can be achieved through hybridization. We further use a price-taker model with simulated hourly energy and capacity prices to determine the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. We find that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60-80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility. Finally, capacity expansion modeling of PV-wind systems indicates that hybridization can reduce transmission expansion requirements associated with a heavily decarbonized U.S. electricity system.

complementarity↗

Market mechanism to enable grid-aware dispatch of Aggregators in radial distribution networks

This paper presents a market-based optimization framework wherein Aggregators can compete for nodal capacity across a distribution feeder and guarantee that allocated flexible capacity cannot cause overloads or congestion. This mechanism, thus, allows Aggregators with allocated capacity to pursue a number of services at the whole-sale market level to maximize revenue of flexible resources. Based on Aggregator bids of capacity (MW) and network access price ($/MW), the distribution system operator (DSO) formulates an optimization problem that prioritizes capacity to the different Aggregators across the network while implicitly considering AC network constraints. This grid-aware allocation is obtained by incorporating a convex inner approximation into the optimization framework that prioritizes hosting capacity to different Aggregators. We adapt concepts from transmission-level capacity market clearing, utility demand charges, and Internet-like bandwidth allocation rules to distribution system operations by incorporating nodal voltage and transformer constraints into the optimization framework. Simulation based results on IEEE distribution networks showcase the effectiveness of the approach.

Nazir, Mohammad Nawaf↗

How structural differences influence cross-model consistency: An electric sector case study

Multiple models are often employed to describe a range of possible outcomes for one or more scenarios, yielding insights into causal relationships and their uncertainties. Electric sector capacity expansion scenarios are a common topic of such efforts due to the economic influence of the electric sector, but model results typically span a broad solution space despite efforts to harmonize input assumptions, making decision implications difficult to discern. This study investigates the relationship between input harmonization and cross-model scenario consistency under disparate electric sector scenarios. We compare cross-model consistency between two state-of-the-art electric sector capacity expansion models (GCAM-USA and ReEDS) for six electric sector scenarios comprising alternate assumptions about fossil fuel resource availability, technology innovation, and long-term economy-wide transitions under four harmonization configurations varying model representations of electricity demand, fuel prices, renewable resources, and capacity retirements. These comparisons reveal that cross-model consistency can vary across scenarios under a given harmonization configuration, suggesting that harmonization efforts must often be scenario-specific if comparable cross-model consistency is desired. Model structural differences can hinder consistency, and the impact of these differences can depend on the scenario. Ultimately, thorough harmonization can reveal insights into cross-model consistency, which can be used to tighten uncertainty bounds and improve the decision-making implications of multi-model activities.

Cohen, Stuart↗

On the Electrochemical Properties of Carbon-Coated NaCrO 2 for Na-Ion Batteries

NaCrO 2 is a promising cathode for Na-ion batteries. However, further studies of the mechanisms controlling its specific capacities and cycle stability are needed for real-world applications in the future. This study reveals, for the first time, that the typical specific capacity of ~110 mAh/g reported by many researchers when the charge/discharge voltage window is set between 2.0 and 3.6 V vs. Na/Na + is actually controlled by the low electronic conductivity at the electrode/electrolyte interface. Through wet solution mixing of NaCrO 2 particles with carbon precursors, uniform carbon coating can be formed on the surface of NaCrO 2 particles, leading to unprecedented specific capacities at 140 mAh/g, which is the highest specific capacity ever reported in the literature with the lower and upper cutoff voltages at the aforementioned values. However, such carbon-coated NaCrO 2 with ultrahigh specific capacity does not improve cycle stability because with the specific capacity at 140 mAh/g the Na deintercalation during charge is more than 50% Na ions per formula unit of NaCrO 2 which leads to irreversible redox reactions. The insights from this study provide a future direction to enhance the long-term cycle stability of NaCrO 2 through integrating carbon coating and doping.

25 ENERGY STORAGE↗

TiO2 Nanocrystal-Framed Li 2 TiSiO 5 Platelets for Low-Voltage Lithium Battery Anode

Titanium-based anode materials are attracting considerable attention for use in high-performance lithium-ion batteries, but the compromised energy density caused by high voltage plateaus and unsatisfactory capacities severely retards their practical applications. Herein, a molten-salt synthesis of Li 2 TiSiO 5 crystalline platelets and a subsequent selective facet modification by in situ growth of TiO 2 nanocrystal frames are facilely achieved. The discharge voltage plateau at around 0.5 V renders the Li 2 TiSiO 5 anode safe compared with graphite and confers a high energy density compared with zero-strain Li 4 Ti 5 O 12 anode. With the optimized size, structure, and content of modified TiO2 nanocrystals associated with the exposed (001) plane of Li 2 TiSiO 5 , the Li 2 TiSiO 5 -based anodes can deliver a capacity of above 300 mAh g -1 , enhanced rate performance, and a capacity retention of 66% after 10 000 cycles. In situ X-ray diffraction and ex situ transmission electron microscopy have demonstrated the structural stability of the anodes upon charge/discharge. Further theoretical calculation reveals 3D migration paths of Li + ions in Li 2 TiSiO 5 . The selective modification of in situ grown TiO2 nanocrystals on certain facets of crystallites opens a new door for the development of electrode materials possessing superior electrochemical properties.

anodes↗

Sodium Rich Vanadium Oxy‐Fluorophosphate – Na 3.2 Ni 0.2 V 1.8 (PO 4 ) 2 F 2 O – as Advanced Cathode for Sodium Ion Batteries

Abstract Conventional sodium‐based layered oxide cathodes are extremely air sensitive and possess poor electrochemical performance along with safety concerns when operating at high voltage. The polyanion phosphate, Na 3 V 2 (PO 4 ) 3 stands out as an excellent candidate due to its high nominal voltage, ambient air stability, and long cycle life. The caveat is that Na 3 V 2 (PO 4 ) 3 can only exhibit reversible capacities in the range of 100 mAh g −1 , 20% below its theoretical capacity. Here, the synthesis and characterizations are reported for the first time of the sodium‐rich vanadium oxyfluorophosphate, Na 3.2 Ni 0.2 V 1.8 (PO 4 ) 2 F 2 O, a tailored derivative compound of Na 3 V 2 (PO 4 ) 3 , with extensive electrochemical and structural analyses. Na 3.2 Ni 0.2 V 1.8 (PO 4 ) 2 F 2 O delivers an initial reversible capacity of 117 mAh g −1 between 2.5 and 4.5 V under the 1C rate at room temperature, with 85% capacity retention after 900 cycles. The cycling stability is further improved when the material is cycled at 50 °C within 2.8–4.3 V for 100 cycles. When paired with a presodiated hard carbon, Na 3.2 Ni 0.2 V 1.8 (PO 4 ) 2 F 2 O cycled with a capacity retention of 85% after 500 cycles. Cosubstitution of the transition metal and fluorine in Na 3.2 Ni 0.2 V 1.8 (PO 4 ) 2 F 2 O as well as the sodium‐rich structure are the major factors behind the improvement of specific capacity and cycling stability, which paves the way for this cathode in sodium‐ion batteries.

25 ENERGY STORAGE↗

A High-Performance Na-Al Battery Based on Reversible NaAlCl4 Catholyte

This work demonstrates a high-capacity and safe Na-Al battery pairing sodium metal anode and reversible NaAlCl4 catholyte for grid scale energy storage applications. The energy-rich sodium anode allows the full play of the aluminum cathode, resulting in a full-cell capacity of 308 mAh/g at a discharge voltage of 1.6 V. Benefiting from the use of ??-alumina solid electrolyte (BASE), molten sodium anode and reversible Al deposition/stripping from NaAlCl4 catholyte, the battery presents a stable Coulombic efficiency of 100% and energy efficiency of ~95%. At a rate of C/3 (6.77 mA/cm2), the cell maintains 282 mAh/g (447 Wh/kg) after 200 cycles with an excellent capacity retention of 97.6%. Moreover, we elucidate pathways to build sodium-anode-free cells from the discharged state under dry air, which further extends the feasibility of this battery for stationary storage applications. These findings are expected to provide a new platform for the development of practical Al batteries.

Zhan, Xiaowen↗

Enhanced Electrochemical Performance of Disordered Rocksalt Cathodes in a Localized High‐Concentration Electrolyte

Abstract Lithium (Li)‐rich transition metal oxide cathodes with a cation disordered rock salt structure (DRX) are increasingly gaining popularity for advanced Li batteries as they offer high capacity and cost benefits over the commonly used layered Li transition metal oxide cathodes. However, the performance of DRX cathodes and their applications are limited by severe side reactions between the cathode and the state‐of‐the‐art carbonate‐based electrolytes at high voltage of 4.8 V, transition metal dissolution, and structural instability of the cathode particles. In this work, an advanced localized high‐concentration electrolyte (LHCE) is developed to form a stable cathode‐electrolyte interphase and mitigate structural instability of the Li 1.13 Mn 0.66 Ti 0.21 O 2 (LMTO) DRX during electrochemical cycling. Li||LMTO half cells with the LHCE demonstrate increased capacity, cycling stability, and superior rate capability compared with cells containing a conventional carbonate electrolyte. For instance, the Li||LMTO cells cycled in LHCE show a higher initial capacity of 205.2 mAh g −1 and a better capacity retention of 72.5% after 200 cycles at a current density of 20 mA g −1 than those with the conventional electrolyte (initial capacity of 187.7 mAh g −1 and capacity retention of 19.9%). This work paves the way to the development of practical DRX cathode‐based high‐energy Li batteries.

25 ENERGY STORAGE↗

Enhancing Li + Transport in NMC811||Graphite Lithium–Ion Batteries at Low Temperatures by Using Low–Polarity–Solvent Electrolytes

LiNi x Co y MnzO 2 (x+y+z=1)||graphite lithium-ion battery (LIB) chemistry promises practical applications. However, its low-temperature (≤ –20°C) performance is poor because the increased resistance encountered by Li + transport in and across the bulk electrolytes and the electrolyte/electrode interphases induces capacity loss and battery failures. Though tremendous efforts have been made, there is still no effective way to reduce the charge transfer resistance (R ct ) which dominates low-temperature LIBs performance. In this work, we propose a strategy of using low-polarity-solvent electrolytes which have weak interactions between the solvents and the Li + to reduce R ct , achieving facile Li + transport at sub-zero temperatures. The exemplary electrolyte enables LiNi 0.8 Mn 0.1 Co 0.1 O 2 ||graphite cells to deliver a capacity of ≈113 mAh g –1 (98% full-cell capacity) at 25°C and to remain 82% of their room-temperature capacity at –20°C without lithium plating at 1/3C. They also retain 84% of their capacity at –30°C and 78% of their capacity at –40°C and show stable cycling at 50°C.

25 ENERGY STORAGE↗

Biopolymer‐assisted Synthesis of P‐doped TiO 2 Nanoparticles for High‐performance Lithium‐ion Batteries: A Comprehensive Study

Abstract TiO 2 material has gained significant attention for large‐scale energy storage due to its abundant, low‐cost, and environmentally friendly properties, as well as the availability of various nanostructures. Phosphorus doping has been established as an effective technique for improving electronic conductivity and managing the slow ionic diffusion kinetics of TiO 2 . In this study, non‐doped and phosphorus doped TiO 2 materials were synthesized using sodium alginate biopolymer as chelating agent. The prepared materials were evaluated as anode materials for lithium‐ion batteries (LIBs). The electrodes exhibit remarkable electrochemical performance, including a high reversible capacity of 235 mAh g −1 at 0.1 C and excellent first coulombic efficiency of 99 %. An integrated approach, combining operando XRD and ex‐situ XAS, comprehensively investigates the relationship between phosphorus doping, material structure, and electrochemical performance, reinforced by analytical tools and first principles calculations. Furthermore, a full cell was designed using 2 %P‐doped TiO 2 anode and LiFePO 4 cathode. The output voltage was about 1.6 V with high initial specific capacity of 148 mAh g −1 , high rate‐capability of 120 mAh g −1 at 1 C, and high‐capacity retention of 96 % after 1000 cycles at 1 C.

El Halya, Nabil↗

Removal of phosphorus using biochar derived from Fenton sludge: Mechanism and performance insights

Abstract A phosphorus removal biochar adsorbent was prepared from Fenton sludge. The adsorption process was optimized, and its phosphorus adsorption mechanism was discussed. It was found that the phosphorus adsorption performance of biochar prepared from single Fenton sludge (FBC‐400) was better than that of co‐pyrolysis of Fenton sludge and bamboo powder. The optimum condition was that Fenton sludge pyrolyzed at 400°C (FBC‐400). FBC‐400 had a larger specific surface area than that prepared by co‐pyrolysis with bamboo powder. And the high content of iron element could provide a higher surface charge of the biochar, thereby increasing the electrostatic adsorption of phosphorus onto FBC‐400. The phosphorus adsorption was highly pH dependent by FBC‐400, which can enhance electrostatic adsorption and increase adsorption capacity in acidic conditions. The effect of coexisting anion on adsorption performance was mainly affected by CO 3 2− , reducing the adsorption capacity by at least 49%, whereas other anions had no obvious interference. The adsorption process of FBC‐400 accorded with the pseudo‐second‐order kinetic model and the Langmuir model, which indicated that the adsorption process was monolayer adsorption and mainly chemical adsorption, and the maximum saturated phosphorus adsorption capacity was 8.77 mg g −1 . The mechanisms for phosphorus adsorption were electrostatic adsorption and inner‐sphere complexing. 1 M NaOH was used for desorption, and the adsorption capacity remained at 81% in the fifth cycle. Practitioner Points The Fenton sludge biochar usage as an adsorbent could be a win‐win strategy to convert waste biomass to valuable ‐ product. The adsorption process accorded with the Langmuir model, the maximum phosphorus adsorption capacity was 8.77 mg/g at 25°C. The adsorption mechanisms were electrostatic adsorption and inner‐sphere complexing. 1M NaOH was used for desorption, and the adsorption capacity remained at 81% in the fifth cycle.

Liu, Yanfang↗

Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Optimization of catholyte for halide-based all-solid-state batteries

Halide solid electrolytes gain significant attention due to their high ionic conductivity, low processing temperature, dry air compatibility, and high-voltage stability. However, low cathode active material (CAM) loading in the composite cathode constrains the realization of high energy density for halide-based all-solid-state batteries. In this study, three halide materials, raw Li 3 YBrCl 5 (LYBC-R, <30μm), milled LYBC (LYBC-M, <5 μm) and freeze-dried Li 3 InCl 6 (LIC, <500 nm), were used as catholytes, combined with LYBC-M as the electrolyte and LiIn alloy as the anode. The CAM:catholyte ratio was investigated as well as stack pressure and operating temperature. Our study demonstrates that particle size of the catholyte plays an important role only for high CAM loading or high C-rate cycling. At moderate CAM loading (65 and 70wt% LiNi 0.83 Mn 0.06 Co 0.11 O 2 ) and 0.1 C-rate, all the three catholytes perform well, providing initial discharge capacities >177 mAh/g. At high CAM loading (85wt%) and 0.1 C-rate, a cathode with the nano-scale LIC catholyte provides discharge capacity of 175 mAh/g, while the larger particle size catholytes suffer significantly reduced capacity. Both LYBC and LIC catholytes provided capacity retention >80% after 200 cycles at 0.5C. These results imply that cathode particle size is critically important for performance at high CAM loading. Furthermore, both electrolyte and cathode were tape cast to scale up size and prepare realistic layer thicknesses. A small amount of binder was used in both layers, to balance the electrochemical performance and mechanical properties. Further, the discharge capacity of a tape cell was 152mA h/g at 0.1C with a capacity retention of 81.8% after 20 cycles at 0.5C. The results demonstrate the excellent performance of LYBC as an electrolyte, and provide guidance for halide-based cathode design.