Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Demonstrating SolarPILOT's Python API Through Heliostat Optimal Aimpoint Strategy Use Case: Preprint

SolarPILOT is a software package that generates heliostat field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL's System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application's graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called "LK." This paper presents a new, full-featured Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT's capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instances with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layout; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying heliostat field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating heliostat field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed tower CSP analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot's functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize CSP tower research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Stochastic Ensemble Generation for Improved Characterization of Representing Geologic Variability in a Reservoir: IBDP Case Study for SMART Initiative

This document is a poster covering the findings from activities on training data generation, specifically geologic ensemble generation. The generated geologic realizations captured the range of possible permeability distributions of the subsurface at the Illinois Basin - Decatur Project (IBDP) site, based on available well log variabilities. The percentages of reservoirs and baffles in the injection zone and a truncation of baffle permeability led to more variance in the simulations. This will be used to build forward modeling, history matching, and optimization workflows. The geologic realizations were also ranked according to dynamic measures of hydraulic diffusivity, and simulations confirm a greater contrast between the reservoir and the baffles during injection.

stochastic ensemble generation↗

SetEnvironment

SAND2025-11727O SetEnvironment software is a utility library module that uses ConfigParserEnhanced, also a library module, to read specifically formatted .ini files for setting the user's environment. It creates a consistent environment with an expected set of variables and module loads, which is important for testing. Environment variable operations include set, append, prepend, unset, remove, and others and uses the Python os.environ methods. The module operations are performed with a wrapper. Systems using the Lmod package can generate a module function, which can also perform module operations specified in the text file. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

McLendon III, William↗

Vegetation Warming Experiment: 15N Uptake Experiment Arctagrostis latifolia 15N Uptake, Utqiagvik (Barrow), Alaska, 2018

This dataset consists of atom percentage of 15N in excess of natural abundance after injection and incubation, uptake rate of 15N during incubation period and percent recovery of 15N labeled ammonia in A. latifolia tissues in vegetation warming experiment enclosures and paired control plots located on the BEO, Utqiagvik, Alaska. Vegetation warming chambers (Zero Power) were deployed on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. These chambers (Figure 1) consistently elevated air temperatures by approximately 4°C using a self-venting system described by Lewin et al (2017). Five chambers were deployed from June 17, 2018 to September 24, 2018 on the BEO within a 1 km2 area centered on 71.275N, -156.641W. Each chamber was co-located with an ambient plot where temperatures were not manipulated on patches of tundra containing the target species Arctagrostis latifolia. An intensive field campaign in late July investigated the impact of warming had on A. latifolia biomass, chemistry, and uptake of 15N labeled ammonia that was injected into the surface soils for one week. Initial measurements were taken on July 21, 2018. Harvest occurred on July 27, 2018. Water-extractable nutrients in soils were measured in July following harvests of A. latifolia plants and underlying soils. Availability of ammonia, nitrate, and phosphate throughout the growing season was measured by extracting nutrients bound to anion and cation binding resins deployed from July through September. Environmental variables (thaw depth, surface soil temperatures, surface soil moisture) were measured. Leaf traits and root traits of A. latifolia were also measured. Files include one *.csv data file and one *.pdf user guide. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: 15N Uptake Experiment Inorganic Nitrogen and Phosphorus on Resins, Utqiagvik (Barrow), Alaska, 2018

This dataset consists of inorganic ammonia, nitrate, and phosphate bound to anion and cation binding resins deployed from July through September 2018 in the surface soils of vegetation warming experiment enclosures and paired control plots. Vegetation warming chambers (Zero Power) were deployed on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. These chambers (Figure 1) consistently elevated air temperatures by approximately 4°C using a self-venting system described by Lewin et al (2017). Five chambers were deployed from June 17, 2018 to September 24, 2018 on the BEO within a 1 km2 area centered on 71.275N, -156.641W. Each chamber was co-located with an ambient plot where temperatures were not manipulated on patches of tundra containing the target species Arctagrostis latifolia. An intensive field campaign in late July investigated the impact of warming had on A. latifolia biomass, chemistry, and uptake of 15N labeled ammonia that was injected into the surface soils for one week. Initial measurements were taken on July 21, 2018. Harvest occurred on July 27, 2018. Water-extractable nutrients in soils were measured in July following harvests of A. latifolia plants and underlying soils. Availability of ammonia, nitrate, and phosphate throughout the growing season was measured by extracting nutrients bound to anion and cation binding resins deployed from July through September. Environmental variables (thaw depth, surface soil temperatures, surface soil moisture) were measured. Leaf traits and root traits of A. latifolia were also measured. Included is one *.csv data file and one *.pdf user guide. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: 15N Uptake Experiment Environmental Observations and Thaw Depth, Utqiagvik (Barrow), Alaska, 2018

This dataset consists of measured soil thaw depth, soil temperature, soil moisture, and Arctagrostis latifolia height in vegetation warming experiment enclosures and paired control plots. Vegetation warming chambers (Zero Power) were deployed on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska. These chambers (Figure 1) consistently elevated air temperatures by approximately 4°C using a self-venting system described by Lewin et al (2017). Five chambers were deployed from June 17, 2018 to September 24, 2018 on the BEO within a 1 km2 area centered on 71.275N, -156.641W. Each chamber was co-located with an ambient plot where temperatures were not manipulated on patches of tundra containing the target species Arctagrostis latifolia. An intensive field campaign in late July investigated the impact of warming had on A. latifolia biomass, chemistry, and uptake of 15N labeled ammonia that was injected into the surface soils for one week. Initial measurements were taken on July 21, 2018. Harvest occurred on July 27, 2018. Water-extractable nutrients in soils were measured in July following harvests of A. latifolia plants and underlying soils. Availability of ammonia, nitrate, and phosphate throughout the growing season was measured by extracting nutrients bound to anion and cation binding resins deployed from July through September. Environmental variables (thaw depth, surface soil temperatures, surface soil moisture) were measured. Leaf traits and root traits of A. latifolia were also measured. Included are two *.csv data files and one *.pdf user guide. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

From EXOSAT to the High Energy Astrophysics Science Archive (HEASARC): X-ray Astronomy Comes of Age

In May 1983 the European Space Agency launched EXOSAT, its first X-ray astronomy observatory. Even though it lasted only 3 short years, this mission brought not only new capabilities that resulted in unexpected discoveries, but also a pioneering approach to operations and archiving that changed X-ray astronomy from observations led by small instrument teams, to an observatory approach open to the entire community through a guest observer program. The community use of the observatory was supported by a small dedicated team of scientists, the precursor to the data center activities created to support e.g. Chandra and XMM-Newton. The new science capabilities of EX OS AT included a 90 hr highly eccentric high earth orbit that allow unprecedented continuous coverage of sources as well as direct communication with the satellite that allowed real time decisions to respond to unexpected events through targets of opportunity. The advantages of this orbit demonstrated by EXOSAT resulted in Chandra and XMM-Newton selecting similar orbits. The three instruments on board the EXOSAT observatory were complementary, designed to give complete coverage over a wide energy band pass of 0.05-50 keY. An onboard processor could be programmed to give multiple data modes that could be optimized in response to science discoveries: These new capabilities resulted in many new discoveries including the first comprehensive study of AGN variability, new orbital periods in X-ray binaries and cataclysmic variables, new black holes, quasi-periodic oscillations from neutron stars and black holes and broad band X-ray spectroscopy. The EXOSAT team generated a well-organized database accessible worldwide over the nascent internet, allowing remote selection of data products, making samples and undertaking surveys from the data. The HEASARC was established by NASA at Goddard Space Flight Center in 1990 as the repository of NASA X-ray and Gamma-ray data. The proven EXOSAT database system became the core of the HEASARC infrastructure. The HEASARC pioneered many concepts now taken for granted including standardized formats using FITS files, restoring data from earlier missions, multi-mission analysis tools and a searchable archive over the world wide web.

White, Nicholas E.↗

Particle Swarm Optimisation for group structure optimization for radiotherapy shielding

Neutron transport simulations are ubiquitous in nuclear engineering because they allow one to model experimental systems and render a model platform for easy perturbation of experimental designs. In addition, simulations allow one to gain experimental insight without actually having to go through the trouble of building a physical experiment. Neutron transport simulations can be stochastic or deterministic based. Stochastic neutron transport simulations are typically simulated using the Monte Carlo method and yield very accurate solutions but are computationally expensive, while deterministic methods are typically faster but can be less accurate. Here we focus on optimizing the accuracy of deterministic neutron transport simulations for radiotherapy simulations. Deterministic neutron transport requires discretization of angle, energy, and space to appropriately analyze the system one is trying to model. Discretization of energy is challenging because of the highly variable neutron flux at certain neutron energies. Improper discretization of energy in the transport model can lead to erroneous results and therefore inaccurate interpretations of the solution. In this study, we evaluate Particle Swarm Optimization (PSO) as a mechanism for selecting optimal group structures for radiotherapy shielding. We tested the particle swarm optimization algorithm on radiotherapy shielding problems using Los Alamos National Laboratory's (LANL) main deterministic transport code PARTISN. Results show that the optimized energy group structures generated from the optimization algorithm outperformed LANL's standard energy group structures, and therefore demonstrate utility in using PSO to expedite computation times due to the increased accuracy obtained with a smaller but optimized group structure. (authors)

43 PARTICLE ACCELERATORS↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

TEAMER: Water Tunnel Data from Testing the Pterofin Skimmer Concept

Pterofin's Skimmer concept relies on a flapping and pitching hydrofoil to extract hydrokinetic energy from water flows. The concept aims to utilize unsteady fluid dynamics phenomena (added mass, shed vorticity, and unsteady boundary layer development) to achieve higher lift coefficients, enabling increased power density of the hydrokinetic device and a fundamental shift in the rpm/torque scaling of the power take off compared with turbines. The Applied Research Laboratory at Penn State, in collaboration with Pterofin, designed and built a proof-of-concept flapping/pitching mechanism which was subsequently tested in ARL's 12-inch water tunnel facility. The mechanical power supplied to or extracted from the mechanism was measured for a range of hydrofoils provided by Pterofin over operating conditions including reduced frequency, Reynolds number, and the ratio between pitching and flapping amplitudes. The power lost to friction in the mechanism was removed from the net power measurement by means of a bare hub tare, with the resultant hydrodynamic power being used to calculate a mechanism-independent and non-dimensional power coefficient. The product of this effort is a dataset describing the power coefficient of a hydrofoil having simultaneous pitching and flapping motions, both of which are approximately sinusoidal. Power coefficients were collected for a range of primary design variables including: - Reduced frequency: 0.01 to 0.95 - Pitching/flapping peak angle ratio: 1.5 to 3.0 - Chord-based Reynolds number: 60,000 to 560,000 Secondary design variables relating to the hydrofoil geometry were explored including: - Aspect ratio - Planform shape - Section thickness distribution - Hydrofoil position relative to the pitching axis - Hydrofoil sweep angle relative to the pitching axis Measured data are provided in mean and time series formats. MATLAB scripts are provided which can be used to generate figures of time-averaged and phase-averaged hydrodynamic power coefficients calculated from the measured data. A complete description of the experiment and data reduction can be found in the Post Access Report for the Pterofin Skimmer test effort which will be available on the TEAMER website. This work was supported by the Pacific Energy Ocean Trust via a TEAMER award.

16 TIDAL AND WAVE POWER↗

On the uncertainties in helium generation predictions for fission and fusion alloys

With ongoing advances in fusion and advanced fission reactors, quantifying irradiation effects in materials is critical. Transmutation-induced helium in cladding and structural materials can drive swelling and embrittlement, thereby reducing these components’ lifespans. Yet most studies ignore the considerable uncertainties in predicting helium generation rates. In this work, we created a code wrapper, F-SCATTER, that automatically performs simulations in FISPACT-II. We used this tool to investigate potential variance in helium generation rate, or He/dpa, calculations based on deviations in alloy composition, irradiating neutron flux spectrum, computational methodology, and nuclear data sources. We used 12 wt% Cr HT9 steel as the reference case and observed a 6.5%–98.3% He/dpa spread based on compositional variation within a single chemical specification, a 1.8%–11.5% He/dpa variation upon the incorporation of a 15% artificial uncertainty in flux at each energy, and a He/dpa difference as high as 231% when using ENDF/B-VIII.0 versus TENDL-2021 data libraries. Similar results were found for other prominent iron-based alloys, including Grade 91, castable nano-structured alloy, and 316H—where additional variations exist based on reactor type (e.g. thermal, fast, or fusion) and alloying elements such as carbon, nitrogen, and nickel. Based on the simulated results, we conclude that a significant part of the heat-to-heat variability in swelling responses of Fe-based alloys can be driven by impurity content in alloy compositions, and, therefore, chemical control should be a key element in supply chain design for advanced nuclear energy systems. Furthermore, we provide critical recommendations on best practices for evaluating and reporting helium production and lattice damage rates when computing predictions with multiphysics programs such as FISPACT-II.

FISPACT-II↗

Introducing the GeoRePORT Resource Size Tool: Reporting on Geothermal Resource Size Estimations Using the Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT): Preprint

The Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT) was developed with funding from the U.S. Department of Energy Geothermal Technologies Office to assist in identifying and pursuing long-term investment strategies through the development of a resource reporting protocol. The assessment protocols used in GeoRePORT allow for comparison of project attributes across locations and geological settings to understand the feasibility of geothermal development. This work introduces the Resource Size Tool, a new feature within the GeoRePORT package that compiles two independent methods for estimating geothermal resource size in terms of energy capacity in MW. Energy production potential for twenty-three case studies was estimated with the Resource Size Tool in order to 1) generate a reasonable range of resource size estimates for a particular geothermal field; 2) illustrate the advantages and limitations of each methodology (such as data input requirements, estimate accuracy and precision, and the appropriate circumstances of use); and 3) test the ability of the resource size tool to provide useful and accurate information for geothermal stakeholders. The tool employs two methods widely used in the geothermal industry: (1) USGS Volumetric and (2) Power Density. Results from our case studies show general overlap between these two methods in terms of resource size estimates; however, they also reveal key differences between the two approaches that should be considered when using such estimates to drive development. First, the two methods rely on different input parameters and therefore one method may be more appropriate and/or accurate for a given project than the other. Second, the Power Density method was found to generate wider ranges of resource size predictions, more consistently aligning with actual power production of the field but with larger scales of error; whereas the USGS Volumetric method predicts narrower ranges but tends to overestimate when compared to current MW production. Future work will refine variables used in the methods with input data from other sections of GeoRePORT and modify uncertainty levels based on the particular datasets used for a given project.

geological↗

Cybersecurity Value-at-Risk Framework

As more variable renewable energy sources are added to the grid, the role of hydropower as a reliable baseline and firming resource is growing more critical. However, the U.S hydropower fleet is not fully prepared to face modern issues such as cybersecurity threats. Hydropower accounts for 37% of U.S. utility-scale renewable electricity but is challenged by diverse infrastructure and legacy devices that predate modern security practices. While new cybersecurity solutions cannot simply be added to current hydropower generation and operation technologies, custom cybersecurity assessments can reveal system-specific threats and risk probabilities and identify mitigating enhancements.

cybersecurity valuation methodology↗

Julia as a unifying end-to-end workflow language on the Frontier exascale system

We evaluate Julia as a single language and ecosystem paradigm powered by LLVM to develop workflow components for high-performance computing. We run a Gray-Scott, 2-variable diffusion-reaction application using a memory-bound, 7-point stencil kernel on Frontier, the US Department of Energy’s first exascale supercomputer. We evaluate the performance, scaling, and trade-offs of (i) the computational kernel on AMD’s MI250x GPUs, (ii) weak scaling up to 4,096 MPI processes/GPUs or 512 nodes, (iii) parallel I/O writes using the ADIOS2 library bindings, and (iv) Jupyter Notebooks for interactive analysis. Results suggest that although Julia generates a reasonable LLVM-IR, a nearly 50% performance difference exists vs. native AMD HIP stencil codes when running on the GPUs. As expected, we observed near-zero overhead when using MPI and parallel I/O bindings for system-wide installed implementations. Consequently, Julia emerges as a compelling high-performance and high-productivity workflow composition language, as measured on the fastest supercomputer in the world.

Godoy, William↗

Report on technical development in ANL for innovative creep testing and measurement

This report summarizes a research effort undertaken by Argonne National Laboratory to accelerate the development of creep data package for ASME code qualification. Progress on the fabrication of a 3-sample load train and the application of a direct current potential drop (DCPD) technique to measure large creep strains are reported. Specifically: (1) The 3-sample load train, with three sets of Linear Variable Differential Transformers (LVDT), has been fabricated and assembled. (2) A DCPD method for creep-strain measurement up to 50% has been demonstrated. The DCPD data matches very well to LVDT results, suggesting its potential application in future creep testing. The technical developments contribute towards shortening the time needed to generate a creep data package for an ASME code case of the laser powder bed fusion 316H stainless steel, an effort under the US Department of Energy’s Advanced Materials and Manufacturing Technologies (AMMT) program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cybersecurity Value-at-Risk Framework: Preprint

As more variable renewable energy sources are added to the grid, the critical role of hydropower as a reliable baseline and firming resource is rapidly growing. However, the U.S hydropower fleet is not fully prepared to face modern issues such as cybersecurity threats. Hydropower accounts for 37% of U.S. utility-scale renewable electricity but is challenged by diverse infrastructure and legacy devices that predate modern security practices. While new cybersecurity solutions cannot simply be added to current hydropower generation and operation technologies, custom cybersecurity assessments can reveal system-specific threats and risk probabilities and identify mitigating enhancements.

cybersecurity valuation↗