Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Measurements of the effective electron density in an electron beam ion trap using extreme ultraviolet spectra and optical imaging

In an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, n e,eff , experienced by the ions, the electron beam size, the nominal electron density n e , and the ion distribution around the beam, i.e., the so-called ion cloud, must be measured. We use imaging techniques in the extreme ultraviolet (EUV) and optical to determine these. The electron beam width is measured using 3 d → 3 p emission from Fe xii and xiii between 185 and 205 Å. These transitions are fast and the EUV emission occurs only within the electron beam. The measured spatial emission profile and variable electron current yield a nominal electron density range of n e ~ 10 11 –10 13 cm –3 . We determine the size of the ion cloud using optical emission from metastable levels of ions with radiative lifetimes longer than the ion orbital periods. Here, the resulting emission maps out the spatial distribution of the ion cloud. We find a typical electron beam radius of ~60 μm and an ion cloud radius of ~300 μ m. These yield a spatially averaged effective electron density, ne,eff, experienced by the ions in EBIT spanning ~ 5 × 10 9 –5 × 10 11 cm –3 .

47 OTHER INSTRUMENTATION↗

Vacuum ultraviolet Mach-Zehnder interferometer with CaF2 optics

CaF2 beam splitters and compensation and test cell windows have been installed in a VUV Mach-Zehnder interferometer. Results of an evaluation of their performance in the VUV, namely, a measurement of the oscillator strength (f value) of the resonance transition at atomic xenon at 146.9610 nm are reported.

Smith, P. L.↗

Synthesis of Electron-Optical Systems with Compression of Sheet Beam for Terahertz TWTs

Electron-optical systems are synthesized to form a converging sheet electron beam with a compression of 15 and 20, a cross section of 0.05 × 2 mm, and a current density of 100 A/cm{sup 2} in the presence of complete magnetic shielding of field-emission cathode. Deformation of low-perveance flux in the presence of magnetic field in the drift tunnel of slow-wave structure is analyzed with the aid of 3D computer simulation of the electron-optical system with the sheet electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved optical standing-wave beam splitters for dilute Bose–Einstein condensates

Bose–Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses’ amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. Here, in simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transformation of a generalized Bessel–Laguerre–Gaussian beam by a paraxial ABCD optical system

An analytical expression of a Generalized Bessel–Laguerre–Gaussian (GBLG) beam passing through a paraxial ABCD optical system is developed by using the generalized Huygens–Fresnel diffraction integral. This result is regarded as the main finding of this paper. Several studies such as the propagation of fundamental Gaussian, flat-topped Gaussian, Bessel–Gaussian, Generalized Bessel–Gaussian and Laguerre–Gaussian beams, through an ABCD optical system, are derived as particular cases of our principle investigation. Numerical simulations are performed, in this work, to illustrate the propagation properties of GBLG beam through a free space, a thin lens, a Fractional Fourier transform system and a quadratic graded-index system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

Optically induced free carrier light modulator

Signal carrier laser beam is optically modulated by a second laser beam of different frequency acting on a free carrier source to which the signal carrier laser is directed. The second laser beam affects the transmission characteristics of the free carrier source to light from the signal carrier laser, thus modulating it.

Gruber, C. L.↗

Calculation of the parameters of the X-ray diffraction station with adaptive segmented optics on the side beam from the wiggler of the Sibir'-2 storage ring

The mounting of an X-ray diffraction station on the side beam of a 19-pole superconducting wiggler makes it possible not only to use the central synchrotron radiation beam with a wavelength of 0.5 Angstrom-Sign , but also to solve problems requiring softer X rays at a synchrotron radiation (SR) intensity exceeding that for the beams from the bending magnet. A numerical simulation of the formation of photon beams from a source and their transmission through the elements of the station (and through the station as a whole) allows one to calculate the parameters of the station, compare it with the existing analogs, determine its potential and actual efficiency of its elements, and estimate the adjustment quality. A numerical simulation of the SR source on the side beam from the wiggler and the focusing channel (segmented condenser mirror, monochromator with sagittal focusing by the segmented second crystal, and segmented focusing mirror) has been performed. The sizes of the focus and the divergence of rays in it are determined with allowance for the finite sizes of segments. The intensity of radiation with a wavelength {lambda} = 1.0 Angstrom-Sign in the focus is determined taking into account the loss in the SR extraction channel and in the focusing channel. The values of the critical wavelength for the side beam from the wiggler and the wavelength resolution are calculated. The intensities in the X-ray diffraction pattern and its angular resolution are found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The matter in extreme conditions instrument at the Linac Coherent Light Source

The LCLS beam provides revolutionary capabilities for studying the transient behavior of matter in extreme conditions. The particular strength of the Matter in Extreme Conditions instrument is that it combines the unique LCLS beam with high-power optical laser beams, and a suite of dedicated diagnostics tailored for this field of science. In this paper an overview of the beamline, the capabilities of the instrumentation, and selected highlights of experiments and commissioning results are presented.

43 PARTICLE ACCELERATORS↗

Laser Beam Steering/shaping for Free Space Optical Communication

The 2-D Optical Phased Array (OPA) antenna based on a Liquid Crystal On Silicon (LCoS) device can be considered for use in free space optical communication as an active beam controlling device. Several examples of the functionality of the device include: beam steering in the horizontal and elevation direction; high resolution wavefront compensation in a large telescope; and beam shaping with the computer generated kinoform. Various issues related to the diffraction efficiency, steering range, steering accuracy as well as the magnitude of wavefront compensation are discussed.

Wang, Xinghua↗

Enhancing X-Ray Generation by Electron-Beam-Laser Interaction in an Optical Bragg Structure

We demonstrate that x-ray radiation emitted by relativistic electrons scattered by a counter-propagating laser pulse guided by an adequate Bragg structure surpasses by about 2 orders of magnitude the energy generated by a conventional free-space Gaussian-beam configuration, given the same e beam and injected laser power in both configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual wavelength laser damage testing for high energy lasers.

As high energy laser systems evolve towards higher energies, fundamental material properties such as the laser-induced damage threshold (LIDT) of the optics limit the overall system performance. The Z-Backlighter Laser Facility at Sandia National Laboratories uses a pair of such kiljoule-class Nd:Phosphate Glass lasers for x-ray radiography of high energy density physics events on the Z-Accelerator. These two systems, the Z-Beamlet system operating at 527nm/ 1ns and the Z-Petawatt system operating at 1054nm/ 0.5ps, can be combined for some experimental applications. In these scenarios, dichroic beam combining optics and subsequent dual wavelength high reflectors will see a high fluence from combined simultaneous laser exposure and may even see lingering effects when used for pump-probe configurations. Only recently have researchers begun to explore such concerns, looking at individual and simultaneous exposures of optics to 1064 and third harmonic 355nm light from Nd:YAG [1]. However, to our knowledge, measurements of simultaneous and delayed dual wavelength damage thresholds on such optics have not been performed for exposure to 1054nm and its second harmonic light, especially when the pulses are of disparate pulse duration. The Z-Backlighter Facility has an instrumented damage tester setup to examine the issues of laser-induced damage thresholds in a variety of such situations [2] . Using this damage tester, we have measured the LIDT of dual wavelength high reflectors at 1054nm/0.5ps and 532nm/7ns, separately and spatially combined, both co-temporal and delayed, with single and multiple exposures. We found that the LIDT of the sample at 1054nm/0.5ps can be significantly lowered, from 1.32J/cm{sup 2} damage fluence with 1054/0.5ps only to 1.05 J/cm{sup 2} with the simultaneous presence of 532nm/7ns laser light at a fluence of 8.1 J/cm{sup 2}. This reduction of LIDT of the sample at 1054nm/0.5ps continues as the fluence of 532nm/7ns laser light simultaneously present increases. The reduction of LIDT does not occur when the 2 pulses are temporally separated. This paper will also present dual wavelength LIDT results of commercial dichroic beam-combining optics simultaneously exposed with laser light at 1054nm/2.5ns and 532nm/7ns.

43 PARTICLE ACCELERATORS↗

High voltage holding in the negative ion sources with cesium deposition

High voltage holding of the large surface-plasma negative ion source with cesium deposition was studied. It was found that heating of ion-optical system electrodes to temperature >100 °C facilitates the source conditioning by high voltage pulses in vacuum and by beam shots. The procedure of electrode conditioning and the data on high-voltage holding in the negative ion source with small cesium seed are described. The mechanism of high voltage holding improvement by depletion of cesium coverage is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical tailoring of xFEL beams

There is an inherent flexibility unique to free electron lasers (FELs) that lends well to experimental approaches normally too difficult for other light sources to accomplish. This includes the ability to optically shape the electron bunch prior to final its acceleration for the final FEL process. Optical pulse shaping of the electron bunch can enable both femtosecond and attosecond level FEL pulse control. Pulse shaping is currently implemented, not optically but mechanically, in LCLS-I with an adjustable foil slit that physically spoils the momentum phase of the electron bunch. This selectively suppresses the downstream FEL process of spoiled electrons. Such a mechanical spoiling method fails for both the soft x-ray regime as well as the high repetition rates that are planned in LCLS-II. Our proposed optical spoiling method circumvents this limitation by making use of the existing ultrafast laser beam that is typically used for adjusting the energy spread for the initial electron bunch. Using Fourier domain shaping we can nearly arbitrarily shape the laser pulses to affect the electron bunch. This can selectively spoil electrons within each bunch. Here we demonstrate the viability of this approach with a programmable acousto-optic dispersive filter. This method is not only well suited for LCLS-II but also has several advantages over mechanical spoiling, including lack of radiation concerns, experiment specific FEL pulse shapes, and real-time adjustment for applications that require high duty-cycle variation such as lock-in amplification of small signals.

43 PARTICLE ACCELERATORS↗

Aperture alignment in autocollimator-based deflectometric profilometers

During the last ten years, deflectometric profilometers have become indispensable tools for the precision form measurement of optical surfaces. They have proven to be especially suitable for characterizing beam-shaping optical surfaces for x-ray beamline applications at synchrotrons and free electron lasers. Deflectometric profilometers use surface slope (angle) to assess topography and utilize commercial autocollimators for the contactless slope measurement. To this purpose, the autocollimator beam is deflected by a movable optical square (or pentaprism) towards the surface where a co-moving aperture limits and defines the beam footprint. In this paper, we focus on the precise and reproducible alignment of the aperture relative to the autocollimator's optical axis. Its alignment needs to be maintained while it is scanned across the surface under test. The reproducibility of the autocollimator's measuring conditions during calibration and during its use in the profilometer is of crucial importance to providing precise and traceable angle metrology. In the first part of the paper, we present the aperture alignment procedure developed at the Advanced Light Source, Lawrence Berkeley National Laboratory, USA, for the use of their deflectometric profilometers. In the second part, we investigate the topic further by providing extensive ray tracing simulations and calibrations of a commercial autocollimator performed at the Physikalisch-Technische Bundesanstalt, Germany, for evaluating the effects of the positioning of the aperture on the autocollimator's angle response. The investigations which we performed are crucial for reaching fundamental metrological limits in deflectometric profilometry.

47 OTHER INSTRUMENTATION↗

Beam Characterization and Coherent Optical Transition Radiation Studies at the Advanced Photon Source Linac

The Advanced Photon Source facility includes a 450-MeV S-band linac with the option for injection from a photocathode (PC) rf gun. A diode-pumped, twice-frequency doubled Nd:glass regen laser (263 nm) is used with the Cu PC to generate the ele ctron beams. Characterization of these beams and studies of the microbunching instability following beam compression in the four-dipole magnetic chicane are described. A suite of diagnostics is employed including a three-screen emittance section, a FIR co herent transition radiation autocorrelator, electron spectrometers, and an optical diagnostics end station. An energy chirp impressed on the beam is used to compress the 1-2 ps, rms bunch as it passes through the chicane. With compression, bunch lengths o f 170-200 fs, rms at 450 pC are measured, and coherent optical transition radiation (COTR) due to the microbunching instability is observed. Mitigation techniques of the COTR in the beam profile diagnostics are demonstrated both spectrally and temporally. At 100 pC without compression normalized transverse emittances of 1.8 and 2.7 microns are observed in the x and y planes, in reasonable agreement with initial ASTRA simulations.

43 PARTICLE ACCELERATORS↗