Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resonances”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.

Lumpkin, Alex H.↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

Thomas Jefferson National Accelerator Facility (Jeffer- son Lab) currently studies the feasibility of upgrading its energy to 22 GeV. It considers addition of six more linac passes. The highest energy passes will share two new arcs designed using the Fixed-Field Alternating Gradient (FFA) technology. The FFA arcs are built using permanent combined-function magnets. They will be connected to the linacs through transition sections that will match the optics of all six passes to the linacs. With the high number of con- straints and the limited space available, we are investigating a parametric resonance technique to match the optics quasi- independently at each energy. A resonance is excited at each individual energy to selectively control its optics. The reso- nant dipole and quadrupole kick harmonics are imposed for all energies simultaneously using Panofsky corrector mag- nets placed throughout the FFA arcs. This paper presents the current progress on that transition section design

Deitrick, K.↗

Geometry Optimization for a Quadrupole Resonator at Jefferson Lab

The quadrupole resonator (QPR) is a sample characterization tool to measure the RF properties of superconducting materials using the calorime-try method at different temperatures, magnetic fields, and frequencies. Such resonators are cur-rently operating at CERN and HZB but suffer from Lorentz force detuning and modes overlap-ping, resulting in higher uncertainties in surface resistance measurement. Using the two CERN's QPR model iterations, the geometry was opti-mized via electromagnetic and mechanical simu-lations to eliminate these issues. The new QPR version was modelled for an increasing range of magnetic fields. The magnetic field is concentrat-ed at the center of the sample to reduce the un-certainty in surface resistance measurements sig-nificantly. This paper discusses the QPR geome-try optimization for the new version of QPR, which is now progressing toward fabrication.

Bira, S.↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ERDE: The Earth-Field Resonance Detection and Evaluation Devices

Researchers at Los Alamos have developed the Earth-field Resonance Detection and Evaluation devices, or ERDE (German for “Earth”) which brings portable chemical analysis and identification into the field. ERDE uses the Earth’s magnetic field to perform nuclear magnetic resonance measurements without the need for sample preparation, costly cryogens, or calibration procedures, meaning it is extremely user-friendly. In fact, using the Earth’s magnetic field allows detection and identification of chemical species through non-magnetic pipes without sampling, reducing the likelihood of costly biofouling. This innovative new device brings together these outstanding benefits to improve processes in the detection of noxious chemicals in water supplies as well as the identification of toxic materials anywhere. There are two fully-functional ERDE prototypes and efforts are underway to miniaturize the system further for improved portability, increased sensitivity, and expanded capabilities. The Laboratory is seeking qualified licensing or CRADA partners to finalize development of this system.

47 OTHER INSTRUMENTATION↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bayesian Monte-Carlo Framework: New Methods for Resonance Parameter Evaluation [Slides]

BMC evaluation is a tool to address imperfect data & models, non-linear models, and non-normal PDFs. ENDF-6 format does not allow non-normal parameter PDFs. Storing posterior sets allow for variance, covariance, skewness, etc. To better predict criticality, we could document non-normal parameter PDFs (i.e. asymmetric uncertainty), consider non-linear sensitivity of $\kappa$ eff to resonance parameters, and reduce uncertainty in key resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to Improve the Evaluated Nuclear Data of Copper Isotopes in the Resolved and Unresolved Resonance Regions

The evaluated nuclear data of the 63,65 Cu isotopes have been updated in the resolved and unresolved resonance energy regions with the goal of improving the fidelity between calculated and measured critical benchmarks. Particular focus was devoted to the 63 Cu(n, γ) cross sections because of their large sensitivity to the reactivity in the benchmark calculations. By focusing on these cross sections, the set of parameters in both resolved and unresolved resonance regions were fitted to available experimental data. The newly updated evaluations were compared to the currently available ENDF/B-VIII.0 evaluations in reactivity calculations for copper-sensitive integral benchmarks. An initial study of the sensitivity of the benchmarks to the angular distributions was performed, finding it necessary to describe the angular distributions more accurately above 100 keV. This investigation uncovered the need for more accurate data for the 63 Cu(n, γ) cross section above 100 keV. An increase in the capture cross section was found to improve agreement for the considered benchmarks.

07 ISOTOPE AND RADIATION SOURCES↗

Third Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of Nucleon Resonance Electroexcitations at Jefferson Lab

Nucleons are the most fundamental three-body systems in Nature. During the last decade crucial progress has been achieved in the exploration of the spectrum and the structure of nucleon resonances. Studies of exclusive ?N, ?+??p, K?, and K? electroproduction off protons on the evolution of the electrocouplings with photon virtuality Q2 using the CLAS spectrometer has revealed a complex interplay between an inner core of three dressed quarks surrounded by an external meson-baryon cloud. CLAS12 is the only facility capable of extending these results on the electrocouplings into the unexplored Q2 range, spanning the domain of quark momenta where ? 50% of hadron mass is generated. The increase of the CEBAF energy and the upgrade of the CLAS12 spectrometer to measure exclusive electroproduction channels at higher luminosity and photon virtualities will offer a unique opportunity to explore how the dominant part of hadron mass and the bound three-quark structure of the resonant states emerge from QCD.

Achenbach, Patrick↗

Magnetic Field Sensing via Optically Detected Magnetic Resonance and Spin Relaxometry Using Nitrogen Vacancies in Nanodiamonds

Quantum sensing is broadly defined as the use of quantum materials, quantum coherence, and/or quantum entanglement to measure physical quantities and/or to enhance the sensitivity of classical analytical measurements. Certain materials exhibit interesting quantum properties that have the potential to be utilized in quantum sensing applications. One such quantum property is electronic spin, which is utilized in this work. Here, we built a custom apparatus capable of conducting both optically detected magnetic resonance (ODMR) and spin relaxometry. The quantum material investigated was an ensemble of nitrogen vacancies (NV) in nanodiamonds. We have characterized the system and measured ODMR spectra for different strengths of the applied DC magnetic field and clearly observed the expected splitting of the resonances due to Zeeman splitting. We also have measured the spin relaxation times for two different powers of the applied AC magnetic field. The lower power dataset exhibited expected exponential temporal dependence of the relaxation of a modified spin state, whereas the higher power dataset exhibited stretched exponential dependence of the evolution of the modified spin state, indicating the presence of high-power phenomena that emerge that retard the relaxation of the spin state.

Lander, Gary↗

Bench testing of an early prototype pitch resonator WEC

This report describes a series of tests performed on a "pitch resonator'" concept for a wave energy converter. The overall testing campaign goals centered on risk reduction for the pitch resonator wave energy converter concept and model validation. Two modes of testing are captured in this report: one using a single degree of freedom test rig and one in which a six degree of freedom Stewart platform was employed.

16 TIDAL AND WAVE POWER↗

Resonance Trajectories and Island Tune Spectra in the Tune Domain

Island tune spectra are introduced, beginning with curves of resonance trajectories plotted in the (Q x , Q I ) tune domain plane (where Q x is horizontal tune and Q I is island tune) for many resonance orders N. A slice in the (Q x , Q I ) plane delivers a Q I -spectrum at a fixed horizontal tune, with one spectral line for every appropriate value of N.

43 PARTICLE ACCELERATORS↗

Resonance Electroexcitations at High Momentum Transfers with Jefferson Lab at 22 GeV

Studies of nucleon resonance electroexcitation amplitudes are providing insight into many facets of strong QCD dynamics. These amplitudes have become available from the analyses of exclusive electroproduction experiments at Jefferson Lab with CLAS in the range of momentum transfers up to 5 GeV and are currently extended to momentum transfers up to 10 GeV by measurements with CLAS12. A 22-GeV upgrade of CEBAF at Jefferson Lab will offer unique opportunities to explore momentum transfers up to 30 GeV corresponding to the full range of distances where nucleon resonance states are generated in strong QCD. These studies can shed light on the emergence of the dominant part of hadron mass.

Achenbach, Patrick [Thomas Jefferson National Acce↗

Reinforcement Learning for In-Spill Optimization of the Mu2e Resonant Extraction: Compensating Non-Stationarity

We present design considerations and challenges for the fast machine learning component of a third-order resonant beam extraction regulation system being commissioned to deliver steady beam rates to the mu2e experiment at Fermilab. Dedicated quadrupoles drive the tune toward the 29/3 resonance each spill, extracting beam at kV multiwire septa. The overall Spill Regulation System consists of (1) a “slow” process using ~100-spill averages to adjust the base quad ramp infrequently, (2) a feedforward harmonic content compensator, and (3) the “fast” ML agent reacting during each ongoing spill with on-the-fly additive corrections to the sum of (1) and (2). We have demonstrated improved beam-rate steadying for a fast ML agent compared to a PID controller using a quasi-physical spill simulation, and demonstrated distillation of that simulation into a predictive surrogate model. Current work includes a data-and-training pipeline to generate data-aware surrogates with real-world dynamics, even as the dynamics shift unpredictably. The surrogates are to act as RL environments against which to train our fast ML control agents before deploying them on FPGA in the live system. Further current efforts focus on modeling and controlling beam loss around the storage ring, understanding additional available hardware inputs to the model, and the interplay of these with beam-steadying performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Removing Coherent ZZ Crosstalk Via a Simple Driven Coupling Resonator

The interaction between computational and non-computational states of nearby coupled qubits in popular NISQ-era superconducting qubit chip platforms, gives rise to an unwanted static ZZ interaction. This always-on term is a common source of coherent errors, in turn limiting the computational potential of such chips. However, it is still unclear how to eliminate such crosstalk noise efficiently and without added complexity. We here discuss experimental results from a recently-proposed technique addressing this issue: using a simple high-coherence coupling resonator, driven so as to induce a controllable phase interaction between the qubits, the inherent crosstalk can be cancelled. Coupled with cross-resonance gates, such a scheme is a potential avenue towards high fidelity entangling operations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

COMSOL Simulation of Optical Whispering Gallery Mode (WGM) Resonator

We simulate whispering-gallery mode coupling in a Si$_3$N$_4$--LiNbO$_3$ waveguide--resonator system using 2D and 3D COMSOL models. Results show that the TM$_{00}$ mode couples far more efficiently than TE$_{00}$ due to weaker confinement and stronger evanescent overlap, with critical coupling reached near a 0.20~µm gap. The study highlights polarization dependence, geometric sensitivity, and birefringence as key factors shaping resonant behavior.

42 ENGINEERING↗