Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Physics - Plasma physics , Mathematics and Computing, Physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Illustration of Neutronic Decoupling in Fresh Fuel Storage Environments [Slides]

Operations beyond static storage of fuel assemblies occur in SFPs (moving around the pool, inspection, etc.). These assemblies are assumed suitably distanced at 30 cm. When assemblies are separated by enough water, the neutrons from one cannot cause fission in another, which results in neutronic decoupling. This assumption was investigated for PWR and BWR assemblies as part of ORNL-TM/2021/2330.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality and Radiation Shielding Impacts of ENDF/B-VIII.0 [Slides]

Several impacts of ENDF/B-VIII.0 on Radiation Shielding Applications were observed by researchers. Most reaction rates, attenuation ratios, and dose rates are similar for ENDF/B-VII.1 and ENDF/B-VIII.0. A significant reduction in reactor dosimetry results was noted. Investigation continues to reveal underlying data for discrepancies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE Sensitivity Tutorial [Slides]

In sensitivity analysis, we seek to quantify the degree to which fundamental data (i.e., nuclear data) influence a system’s response. In uncertainty analysis, we seek to quantify the degree to which uncertainty in fundamental data contributes to uncertainty in a system’s response. In SCALE, the TSUNAMI suite provides tools for sensitivity and uncertainty analysis, similarity analysis, and nuclear data and covariance adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cumulative χ 2 Metric for VALID for ENDF/B-VII.1 and ENDF/B-VIII.0 in SCALE 6.3b9 [Slides]

Quantifying the performance of a new evaluation is difficult and doing so for a new library is significantly more challenging. Cumulative χ 2 metric is an established approach to comparing distributions. In this case, C/E results from different libraries. Andrei Trkov and Roberto Capote have published cumulative χ 2 results for ENDF/B-VIII.0. Cumulative χ 2 metric was recently calculated for VALID library maintained at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte-Carlo Evaluation Framework for Imperfect Nuclear Data [Slides]

BMC evaluation is a tool used to address imperfect data and models, non-linear models, and non-normal PDFs. ENDF-6 format does not allow non-normal parameter PDFs. Storing posterior sets allows for variance, covariance, skewness, etc. To better predict criticality, we should document non-normal parameter PDFs (i.e. asymmetric uncertainty) and consider non-linear sensitivity of $k_{\text{eff}}$ to resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte-Carlo Framework: New Methods for Resonance Parameter Evaluation [Slides]

BMC evaluation is a tool to address imperfect data & models, non-linear models, and non-normal PDFs. ENDF-6 format does not allow non-normal parameter PDFs. Storing posterior sets allow for variance, covariance, skewness, etc. To better predict criticality, we could document non-normal parameter PDFs (i.e. asymmetric uncertainty), consider non-linear sensitivity of $\kappa$ eff to resonance parameters, and reduce uncertainty in key resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ORNL Neutron Cross Section Measurements of 90 Zr NCSP ND-1 Task [Slides]

Luiz Leal's idea to integrate the experimental uncertainties, covariances, and sensitivities in this workflow and centralize the process at one location led to the creation of a cohesive tool for data testing. It has been practiced for more than two decades by the NCS and ND groups at ORNL. The development and use of the ORNL codes TSUNAMI and TSURFER within SCALE made it possible. Today, it has been extended to SAMINT which enables the coupling of differential and integral data evaluation in a continuous-energy framework.

43 PARTICLE ACCELERATORS↗

Advances in Nuclear Data Evaluation Theory for NCSP [Slides]

The generalized form of the Bayes’ Theorem improves UQ for NCSP of differential and/or integral data evaluations and of applications. It is being implemented in an API for use by SCALE, SAMMY, etc. Extended R-matrix formalism improves evaluations of RRR including direct reactions, direct capture, and the Reich-Moore approx., doorway state reactions with applications to RPI data on lead isotopes. Extended R-Matrix formalism will be implemented into SAMMY post modernization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Horizontal Split Table Conceptual Design for Validation of Nuclear Data used in Advanced Reactors [Slides]

A methodology to create conceptual designs of benchmark critical experiments for advanced reactors nuclear data testing and validation was developed. A first concept was explored, pebble-bed high-temperature gas cooled reactor, based on the HTR-10 reactor. The very high correlation is a proof of concept that the design is similar to the application, and performing such critical experiments would help nuclear data testing and validation. This proof-of-concept was included in the IER-539 CED-1:Preliminary Design of a New Horizontal Split Table report. Other concepts could be explored if needed, such as Molten-salt reactor, Sodium-cooled fast reactor or Heat pipe reactors/Microreactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Expanded Validation of Uranium Systems with the KENO Monte Carlo Codes and SCALE 6.2.4 [Slides]

There is likely a trend in bias for uranium-fueled systems as a function of spectrum, but probably not as a function of enrichment. Some enrichment trends appear, but are potentially the result of outlier experimental results; further investigation is needed where possible. There are good examples in this data of markedly different biases from different systems. Future work includes review and vetting for inclusion in the VALID library and analysis with TSUNAMI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAMMY Modernization Efforts [Slides]

This presentation details several SAMMY modernization and maintenance goals, as well as the efforts made towards these goals and future plans for SAMMY.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to the n+ 63,65 Cu Evaluations: RRR and Angular Distributions [Slides]

This work updates the evaluation of n+ 63,65 Cu for neutron energies in the resolved resonance region (RRR) and slightly higher energies. The updates strive to improve the statistical properties of the resonance parameters and the continuity of the evaluation between the RRR and the high-energy region while preserving or improving critical assembly benchmark performance. We will review our work on the resonance parameters and present the current status of our angular distribution analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Slide Rule Update - Phase 4 Plutonium Configurations – Delayed Gamma [Slides]

The fourth phase of Slide-Rule update gives a calculation scheme for DFG doses and its application to five plutonium material, as well as comparisons between radiation transport and depletion codes such as MCNP, SCALE, COG and FISPACT. Overall, DFG dose rates calculated by each laboratory led to consistent results. Extra effort is under way to identify the cause of the remaining differences, especially for case 2, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Simulation of MC-Small Design

In order to design a lightweight, highly portable neutron multiplicity counter for use in higher risk regions by mobile field teams, a redesign of the MC-15 is being performed, with the goal of producing a detector below 30 lbs for ease of transport. To achieve this, multiple MCNP® simulations were run, evaluating the number and positioning of the He-3 tubes in the detector as well as the amount of high-density polyethylene (HDPE) surrounding the tubes. Based on these simulations, the proposed redesign of the MC-15 (aka MC-Small) possesses 11 tubes and is 13 in wide, 3.21 in thick and 13 in tall. Including the changes to the positioning of the tubes and the removal of HDPE from less sensitive regions of the detectors (i.e. bases of tubes, back of detector), this resulted in an efficiency of 0.56% when measuring a bare Cf-252 source 19.69 in away, only 28% less efficient (relatively) than the MC-15 while weighing 18 lbs, 12 lbs less than the weight of the MC-15.

42 ENGINEERING↗

Error Study of FlecSim Using the Method of Manufactured Solutions [Slides]

Error was calculated using exact solution chosen with the method of manufactured solutions. Hydrodynamics match expected order of accuracy for spatial error within 1.5% for all variables tested. Radiation transport matches expected order of temporal accuracy within 0.5% for all variables tested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗