Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lifetime”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Long-term orbital lifetime predictions

Long-term orbital lifetime predictions are analyzed. Predictions were made for three satellites: the Solar Max Mission (SMM), the Long Duration Exposure Facility (LDEF), and the Pegasus Boiler Plate (BP). A technique is discussed for determining an appropriate ballistic coefficient to use in the lifetime prediction. The orbital decay rate should be monitored regularly. Ballistic coefficient updates should be done whenever there is a significant change in the actual decay rate or in the solar activity prediction.

Dreher, P. E.↗

Predicting Lifetimes Of CMOS ASIC's From Test Data

Concise report discusses recent developments in use of semiempirical mathematical models to predict rates of failure and operating lifetimes of complementary metal oxide/semiconductor (CMOS) application-specific integrated circuits (ASIC's). Each model represents specific mechanism of failure. Once failure mechanisms and models relevant to given ASIC chosen, adjustable parameters in models fitted to life-test data acquired from representative integrated-circuit structures on test coupons fabricated along with ASIC's. Then design parameters of ASIC's incorporated into models, and models yield lifetimes.

Buehler, Martin G.↗

Positron lifetime spectroscopy for investigation of thin polymer coatings

In the aerospace industry, applications for polymer coatings are increasing. They are now used for thermal control on aerospace structures and for protective insulating layers on optical and microelectronic components. However, the effectiveness of polymer coatings depends strongly on their microstructure and adhesion to the substrates. Currently, no technique exists to adequately monitor the quality of these coatings. We have adapted positron lifetime spectroscopy to investigate the quality of thin coatings. Results of measurements on thin (25-micron) polyurethane coatings on aluminum and steel substrates have been compared with measurements on thicker (0.2-cm) self-standing polyurethane discs. In all cases, we find positron lifetime groups centered around 560 psec, which corresponds to the presence of 0.9-A(exp 3) free-volume cells. However, the number of these free-volume cells in thin coatings is larger than in thick discs. This suggests that some of these cells may be located in the interfacial regions between the coatings and the substrates. These results and their structural implications are discussed in this report.

Singh, Jag J.↗

Radiative lifetimes, branching rations, and absolute transition probabilities in Cr II and Zn II

New absolute atomic transition probability measurements are reported for 12 transitions in Cr II and two transitions in Zn II. These transition probabilities are determined by combining branching ratios measured by classical techniques and radiative lifetimes measured by time-resolved laser-induced fluorescence. The measurements are compared with branching fractions, radiative lifetimes, and transition probabilities in the literature. The 206 nm resonance multiplets in Cr II and Zn II are included in this work. These multiplets are very useful in determining the distribution of the elements in the gas versus grain phases in the interstellar medium.

Bergeson, S. D.↗

Positron lifetime spectroscopy in thin polymer coatings

Polymer coatings are finding increasing applications in aerospace industry. The effectiveness of coatings depends strongly on their microstructure and adhesion to the substrates. Currently, there is no technique for adequately monitoring the quality of the coatings. We adapted positron lifetime spectroscopy for the investigation of thin coatings. Results of measurements on 0.001-in-thick polyurethane coatings on aluminum and steel substrates and thicker (0.080-in.) self-standing polyurethane discs were compared. In all cases, we find positron lifetime groups centered around 560 ps, corresponding to the presence of 0.9 A exp 3 free volume cells. However, the number of free volume cells in thin coatings is larger, suggesting that the morphology of thin coatings is different from that of bulk polyurethane. These results and their structural implications are discussed.

Singh, Jag J.↗

Lifetimes and eigenstates in atmospheric chemistry

The time scales and mode of the atmosphere's response to chemical perturbations are defined by the eigenvalues and eigenvectors of the system. The eigenstates of a simplified one-box CH4-CO-OH system are analyzed. The longest time constant (smallest eigenvalue) always exceeds the lifetime defined by the steady-state loss frequency for CH4, the longest lived gas. Thus, the extent of a CH4 perturbation -- the methane response time -- is always longer than predicted by the steady-state lifetime and is independent of size of the perturbation in the linear limit. This lengthening of the atmospheric recovery time can be diagnosed by how close we are to a chemically unstable troposphere, i.e., how much OH production exceeds that minimum needed to oxidize just the global emissions of CH4, CO, and other hydrocarbons and species.

Prather, Michael J.↗

Heuristic Modeling for TRMM Lifetime Predictions

Analysis time for computing the expected mission lifetimes of proposed frequently maneuvering, tightly altitude constrained, Earth orbiting spacecraft have been significantly reduced by means of a heuristic modeling method implemented in a commercial-off-the-shelf spreadsheet product (QuattroPro) running on a personal computer (PC). The method uses a look-up table to estimate the maneuver frequency per month as a function of the spacecraft ballistic coefficient and the solar flux index, then computes the associated fuel use by a simple engine model. Maneuver frequency data points are produced by means of a single 1-month run of traditional mission analysis software for each of the 12 to 25 data points required for the table. As the data point computations are required only a mission design start-up and on the occasion of significant mission redesigns, the dependence on time consuming traditional modeling methods is dramatically reduced. Results to date have agreed with traditional methods to within 1 to 1.5 percent. The spreadsheet approach is applicable to a wide variety of Earth orbiting spacecraft with tight altitude constraints. It will be particularly useful to such missions as the Tropical Rainfall Measurement Mission scheduled for launch in 1997, whose mission lifetime calculations are heavily dependent on frequently revised solar flux predictions.

Jordan, P. S.↗

Microstructural Characterization of Polymers by Positron Lifetime Spectroscopy

Positrons provide a versatile probe for monitoring microstructural features of molecular solids. In this paper, we report on positron lifetime measurements in two different types of polymers. The first group comprises polyacrylates processed on earth and in space. The second group includes fully-compatible and totally-incompatible Semi-Interpenetrating polymer networks of thermosetting and thermoplastic polyimides. On the basis of lifetime measurements, it is concluded that free volumes are a direct reflection of physical/electromagnetic properties of the host polymers.

Singh, Jag J.↗

Microstructural Characterization of Semi-Interpenetrating Polymer Networks by Positron Lifetime Spectroscopy

Thermoset and thermoplastic polyimides have complementary physical and mechanical properties. Whereas thermoset polyimides are brittle and generally easier to process, thermoplastic polyimides are tough but harder to process. A combination of these two types of polyimides may help produce polymers more suitable for aerospace applications. Semi-Interpenetrating Polymer Networks (S-IPN) of thermoset LaRC(TM)-RP46 and thermoplastic LaRC(TM)-IA polyimides were prepared in weight percent ratios ranging from 100:0 to 0:100. Positron lifetime measurements were made in these samples to correlate their free volume features with physical and mechanical properties. As expected, positronium atoms are not formed in these samples. The second lifetime component has been used to infer the positron trap dimensions. The 'free volume' goes through a minimum at a ratio of about 50:50, and this suggests that S-IPN samples are not merely solid solutions of the two polymers. These data and related structural properties of the S-IPN samples are discussed.

Singh, Jag J.↗

The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445 N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

Jones, William R., Jr.↗

The Effect of ODC-Free Cleaning Techniques on Bearing Lifetimes in the Parched Elastohydrodynamic Regime

A parched elastohydrodynamic rig was used to determine relative bearing lifetimes as a function of cleaning procedures in a series of accelerated tests. Two ODC-free cleaning procedures (super critical CO2 and ultraviolet-ozone) were compared to a CFC-113 control. Bearings (52100 steel) were run in the counter rotating mode (equivalent to 4600 rpm) with a full complement (i.e. no retainer) and a single charge of lubricant (Krytox 143 AC). Test conditions included: an air atmosphere, 445N load, approx. 1.0 GPa mean Hertz stress. There was approximately a 50% reduction in life with bearings cleaned with UV/ozone and a 70% reduction in life with SFE CO2 when compared to the Freon control. Possible reasons for these decreases in lifetimes are presented.

Jones, William R., Jr.↗

Stressed-Oxidation Lifetime of Different SiC Fiber, CVI Matrix SiC Minicomposites in Air

The stressed-oxidation lifetime properties of several minicomposites composed of single fiber tows with a CVI SiC matrix were compared. The minicomposites were made up of Nicalon(Tm) and Hi-Nicalon(Tm) SiC fibers with carbon or BN interphases. Constant load stress-rupture tests were performed between 600 and 13000 C in air for all of the minicomposite systems. Cyclic load testing was performed on the Hi-Nicalon minicomposite systems. The factors controlling the different lifetime behaviors: fiber rupture properties, interphase oxidation, fiber degradation, and fiber-matrix bonding, are discussed in light of different minicomposite constituents. All of the systems were subject to intermediate temperature embrittlement. The Hi-Nicalon fiber, BN interphase system, performed the best for constant load conditions. For cyclic load conditions, both the BN- interphase and C-interphase minicomposites displayed poor, but different failure behavior.

Morscher, Gregory N.↗

Effects of Orbital Lifetime Reduction on the Long-Term Earth Satellite Population as Modeled by EVOLVE 4.0

The latest update of the NASA orbital debris environment model, EVOLVE 4.0, has been used to study the effect of various proposed debris mitigation measures, including the NASA 25-year guideline. EVOLVE 4.0, which includes updates of the NASA breakup, solar activity, and the orbit propagator models, a GEO analysis option, and non-fragmentation debris source models, allows for the statistical modeling and predicted growth of the particle population >1 mm in characteristic length in LEO and GEO orbits. The initial implementation of this &odel has been to study the sensitivity of the overall LEO debris environment to mitigation measures designed to limit the lifetime of intact objects in LEO orbits. The mitigation measures test matrix for this study included several commonly accepted testing schemes, i.e., the variance of the maximum LEO lifetime from 10 to 50 years, the date of the initial implementation of this policy, the shut off of all explosions at some specified date, and the inclusion of disposal orbits. All are timely studies in that all scenarios have been suggested by researchers and satellite operators as options for the removal of debris from LEO orbits.

Krisko, Paula H.↗

Long Holographic Lifetimes in Bacteriorhodopsin Films

The D85N genetic variant of bacteriorhodopsin displays a nearly permanent lifetime of the photochromic P490 state. We present pump-probe measurements that demonstrate this behavior. However, experimental diffraction efficiency measurements made from holograms recorded in a hydrated D85N film show markedly different decay behavior, suggesting a molecular diffusion process occurring in the film. Holograms recorded with different grating frequencies display correspondingly different decay times which support this hypothesis. A thin D85N film was then fabricated which was chemically crosslinked, resulting in the elimination of diffusion of BR molecules within the polymer matrix. This film exhibits a grating lifetime on the order of weeks or more, thus allowing the long term holographic storage of information in a BR film.

Downie, John D.↗

Measurement of Metastable Lifetimes of Highly-Charged Ions

The present work is part of a series of measurements of metastable lifetimes of highly-charged ions (HCIs) which contribute to optical absorption, emission and energy balance in the Interstellar Medium (ISM), stellar atmospheres, etc. Measurements were carried out using the 14-GHz electron cyclotron resonance ion source (ECRIS) at the JPL HCI facility. The ECR provides useful currents of charge states such as C(sup(1-6)+), Mg(sup(1-6)+) and Fe(sup(1-17)+). In this work the HCI beam is focused into a Kingdon electrostatic ion trap for measuring lifetimes via optical decays.

Smith, Steven J.↗

Measurement of the metastable lifetime for the 2s^2 2p^2 ^1So level in O^2+

The radiative lifetime of the 1S0 level was found to be 540 +/- 27 ms. This is in good agreement with a previous measurement and with a number of theoretical calculations. Metastable lifetimes, when combined with collisional excitation rates, can provide a diagnostic for electron density Ne in a stellar or solar plasma.

atomic data solar plasmas↗

Improving Lifetime of Quasi-CW Laser Diode Arrays for Pumping 2-Micron Solid State Lasers

Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data on the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

Amzajerdian, Farzin↗

Signal generation and mixing electronics for frequency-domain lifetime and spectral fluorometry

The present invention additionally comprises a method and apparatus for generating and mixing signals for frequency-domain lifetime and spectral fluorometry. The present invention comprises a plurality of signal generators that generate a plurality of signals where the signal generators modulate the amplitude and/or the frequency of the signals. The present invention uses one of these signals to drive an excitation signal that the present invention then directs and transmits at a target mixture, which absorbs the energy from the excitation signal. The property of fluorescence causes the target mixture to emit an emitted signal that the present invention detects with a signal detector. The present invention uses a plurality of mixers to produce a processor reference signal and a data signal. The present invention then uses a processor to compare the processor reference signal with the data signal by analyzing the differences in the phase and the differences in the amplitude between the two signals. The processor then extracts the fluorescence lifetime and fluorescence spectrum of the emitted signal from the phase and amplitude information using a chemometric analysis.

Cruce, Tommy C.↗