Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A Combined XRD/XRF Instrument for Lunar Resource Assessment

Robotic surface missions to the Moon should be capable of measuring mineral as well as chemical abundances in regolith samples. Although much is already known about the lunar regolith, our data are far from comprehensive. Most of the regolith samples returned to Earth for analysis had lost the upper surface, or it was intermixed with deeper regolith. This upper surface is the part of the regolith most recently exposed to the solar wind; as such it will be important to resource assessment. In addition, it may be far easier to mine and process the uppermost few centimeters of regolith over a broad area than to engage in deep excavation of a smaller area. The most direct means of analyzing the regolith surface will be by studies in situ. In addition, the analysis of the impact-origin regolith surfaces, the Fe-rich glasses of mare pyroclastic deposits, are of resource interest, but are inadequately known; none of the extensive surface-exposed pyroclastic deposits of the Moon have been systematically sampled, although we know something about such deposits from the Apollo 17 site. Because of the potential importance of pyroclastic deposits, methods to quantify glass as well as mineral abundances will be important to resource evaluation. Combined x ray diffraction (XRD) and x ray fluorescence (XRF) analysis will address many resource characterization problems on the Moon. XRF methods are valuable for obtaining full major-element abundances with high precision. Such data, collected in parallel with quantitative mineralogy, permit unambiguous determination of both mineral and chemical abundances where concentrations are high enough to be of resource grade. Collection of both XRD and XRF data from a single sample provides simultaneous chemical and mineralogic information. These data can be used to correlate quantitative chemistry and mineralogy as a set of simultaneous linear equations, the solution of which can lead to full characterization of the sample. The use of Rietveld methods for XRD data analysis can provide a powerful tool for quantitative mineralogy and for obtaining crystallographic data on complex minerals.

Vaniman, D. T.↗

Mars sample return mission: What level of complexity

The complexity of the U.S. Sample Return Mission is ultimately dependent on current mission funding and the projected direction of the U.S. space program. Despite these uncertainties, it is important to examine mission scenarios to address desired scientific objectives that can be summarized in the following list: (1) determine existence of climatic records in geologic records; (2) does Mars have a subpermafrost groundwater system; (3) fundamental questions on the existence of Mars biology; (4) what is the internal structure of Mars; (5) determine the systems for regolith formation; and (6) what is the contribution of meteorites to Martian geology and climate are presented. To address these objectives, the sample size, quantity and location must be established and whether this should be the only data searched for on the Martian surface. With this in mind, three mission scenarios are briefly discussed, in order of increasing complexity.

Ciesla, Thomas M.↗

Seal Sample Fixtures

The development of the International Space Station is critically dependent upon development and testing of materials that will require exposure to the space environment. The seals between the modules are one of the more important examples. The choice of seals depends upon the seal materials' susceptibility to atomic oxygen, UV radiation, and the combined external space environment. Also, the choice of thermal control materials depends on their susceptibility to the space environment. The Space Environmental Branch at MSFC developed a flight experiment to provide information on the effects of the space environment on seal and thermal control materials. The experiment, called the Passive Optical Sample Array (POSA), involved exposing several different material samples to the atomic oxygen, UV radiation, and combined effects of the space environment. The POSA experiment is currently flying on the Russian Mir space station. It was necessary during the assembly of POSA to develop an understanding of available fabrication and metrology techniques in order to develop several monitoring systems for the experiment. The report briefly describes the tasks and the work performed in preparing the samples for the POSA experiment.

White, Edwin↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

Electric Field Effects in Self-Propagating High-Temperature Synthesis under Microgravity Conditions

Self-propagating high-temperature synthesis (SHS) has been used to form many materials. SHS generally involves mixing reactants together (e.g., metal powders) and igniting the mixture such that a combustion (deflagration) wave passes though the mixture. The imposition of an electric field (AC or DC) across SHS reactants has been shown to have a marked effect on the dynamics of wave propagation and on the nature, composition, and homogeneity of the product . The use of an electric field with SHS has been termed "field-assisted SHS". Combustion wave velocities and temperatures are directly affected by the field, which is typically perpendicular to the average wave velocity. The degree of activation by the field (e.g., combustion rate) is related to the current density distribution within the sample, and is therefore related to the temperature-dependent spatial distribution of the effective electrical conductivity of reactants and products. Furthermore, the field can influence other important SHS-related phenomena including capillary flow, mass-transport in porous media, and Marangoni flows. These phenomena are influenced by gravity in conventional SHS processes (i.e., without electric fields). As a result the influence of the field on SHS under reduced gravity is expected to be different than under normal gravity. It is also known that heat loss rates from samples, which can depend significantly on gravity, can influence final products in SHS. This research program is focused on studying field-assisted SHS under reduced gravity conditions. The broad objective of this research program is to understand the role of an electric field in SHS reactions under conditions where gravity-related effects are suppressed. The research will allow increased understanding of fundamental aspects of field-assisted SHS processes as well as synthesis of materials that cannot be formed in normal gravity.

Unuvar, C.↗

Micrometeoroid and Lunar Secondary Ejecta Flux Measurements: Comparison of Three Acoustic Systems

This report examines the inherent capability of three large-area acoustic sensor systems and their applicability for micrometeoroids (MM) and lunar secondary ejecta (SE) detection and characterization for future lunar exploration activities. Discussion is limited to instruments that can be fabricated and deployed with low resource requirements. Previously deployed impact detection probes typically have instrumented capture areas less than 0.2 square meters. Since the particle flux decreases rapidly with increased particle size, such small-area sensors rarely encounter particles in the size range above 50 microns, and even their sampling the population above 10 microns is typically limited. Characterizing the sparse dust population in the size range above 50 microns requires a very large-area capture instrument. However it is also important that such an instrument simultaneously measures the population of the smaller particles, so as to provide a complete instantaneous snapshot of the population. For lunar or planetary surface studies, the system constraints are significant. The instrument must be as large as possible to sample the population of the largest MM. This is needed to reliably assess the particle impact risks and to develop cost-effective shielding designs for habitats, astronauts, and critical instrument. The instrument should also have very high sensitivity to measure the flux of small and slow SE particles. is the SE environment is currently poorly characterized, and possess a contamination risk to machinery and personnel involved in exploration. Deployment also requires that the instrument add very little additional mass to the spacecraft. Three acoustic systems are being explored for this application.

Corsaro, R. D.↗

Minimum Arc Threshold Voltage Experiments on Extravehicular Mobility Unit Samples

The International Space Station (ISS) is now under construction in Low Earth Orbit (LEO). The process of building the ISS requires that astronauts carry out many Extravehicular Activities. To protect the astronauts form the hazardous space environment, they are required to wear a suit known as the Extravehicular Mobility Unit (EMU). For most Extra-Vehicular Activities (EVAs) the EMU is tethered to ISS via a steel safety tether. During the course of an EVA it is common for the safety tether to contact exposed metal on both the ISS and the EMU. In this case, the single point ground of the EMU would be at the same potential as the ISS with respect to the LEO Plasma. In the event that the metal structure of the ISS begins to charge negative of the plasma potential as a result of electron collection by the ISS photovoltaic arrays, then the EMU would also be driven to a negative potential. Anodized aluminum components on the EMU would then begin to develop a charge across their amortization layer as ions from the plasma are collected. In the case where large negative potentials are applied to the EMU, dielectric breakdown may occur as a large voltage difference is developed across the thin amortization layer (oxide). The resulting arc plasma may in turn couple to the charge accumulated on the nearby ISS anodized debris shields and thereby generate a large current flow through the metal EMU structure. Current flow through the EMU could result in an electrocution hazard for the Crew Member inside the EMU - and therefore represents an important safety concern. To address this concern, a series of experiments have been undertaken. In each experiment specially prepared anodized aluminum samples were placed in a LEO representative plasma and charged until dielectric breakdown occurred in the form of an arc. This process was repeated a number of times for three sets of samples. During each test the arc voltage and current were monitored. A statistical treatment of the arc voltage threshold will be presented. In addition, safe operating voltages for the EMU are suggested.

Schneider, Todd↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

C-13O-16/C-12O-18 ratios in nine H II regions.

Investigation of carbon monoxide spectra in sources where the C-12O-18 line is observed at an intensity typically about one-sixth that of the C-13O-16 line. This pair of lines affords the opportunity of studying the relative abundance of their constituents, especially the astrophysically important C-12/C-13 ratio. Data are presented on a total of nine sources which together constitute a reasonable sample of the regions with strong molecular spectra.

Penzias, A. A.↗

Applicability of ERTS for surveying Antarctic iceberg resources

The author has identified the following significant results. This investigation explores the applicability of ERTS to (1) determine the Antarctic sea ice and environmental behavior that may influence the harvesting of icebergs, and (2) monitor iceberg locations, characteristics, and evolution. From image sampling, it is found that the potential applicability of ERTS to the research, planning, and harvesting operations can contribute importantly to the promise derived from broader scope studies for the use of Antarctic iceberg to relieve fresh Thermal sensor bands will provide coverage in daylight and darkness. Several years of comprehensive monitoring will be necessary to characterize sea ice and environmental behavior and iceberg evolution. Live ERTS services will assist harvesting control and claming operations and offer a means for harmonizing entitlements to iceberg resources. The valuable ERTS services will be more cost effective than other means and will be easily justified and borne by the iceberg harvesting operation.

Hult, J. L.↗

Wheat signature modeling and analysis for improved training statistics

The author has identified the following significant results. The spectral, spatial, and temporal characteristics of wheat and other signatures in LANDSAT multispectral scanner data were examined through empirical analysis and simulation. Irrigation patterns varied widely within Kansas; 88 percent of wheat acreage in Finney was irrigated and 24 percent in Morton, as opposed to less than 3 percent for western 2/3's of the State. The irrigation practice was definitely correlated with the observed spectral response; wheat variety differences produced observable spectral differences due to leaf coloration and different dates of maturation. Between-field differences were generally greater than within-field differences, and boundary pixels produced spectral features distinct from those within field centers. Multiclass boundary pixels contributed much of the observed bias in proportion estimates. The variability between signatures obtained by different draws of training data decreased as the sample size became larger; also, the resulting signatures became more robust and the particular decision threshold value became less important.

Nalepka, R. F.↗

LANDSAT detection of hydrothermal alteration in the Nogal Canyon Cauldron, New Mexico

In 1974 a circular-shaped iron oxide anomaly was observed in an image of a LANDSAT frame centered near Truth or Consequences, New Mexico. Field examination of the anomaly has shown that it coincides with a zone of hydrothermal alteration on the northern edge of the Nogal Canyon Cauldron. The altered area contains clay minerals ranging in colors from white to vivid red, the latter presumably resulting from hematite staining. In situ gas measurements showed no evidence of active hydrogen sulfide seepage. Preliminary geochemical analyses of grab samples have detected no significant amounts of mineralization. Whereas this area does not at present appear to be economically important, it provides an example of how LANDSAT can be utilized in reconnaissance mapping for cauldrons, calderas, and other volcanic features which display hydrothermal alteration.

Vincent, R. K.↗

Extinction-sedimentation inversion technique for measuring size distribution of artificial fogs

In measuring the size distribution of artificial fog particles, it is important that the natural state of the particles not be disturbed by the measuring device, such as occurs when samples are drawn through tubes. This paper describes a method for carrying out such a measurement by allowing the fog particles to settle in quiet air inside an enclosure through which traverses a parallel beam of light for measuring the optical depth as a function of time. An analytic function fit to the optical depth time decay curve can be directly inverted to yield the size distribution. Results of one such experiment performed on artificial fogs are shown as an example. The forwardscattering corrections to the measured extinction coefficient are also discussed with the aim of optimizing the experimental design so that the error due to forwardscattering is minimized.

Deepak, A.↗

Land-surface temperature measurement from space - Physical principles and inverse modeling

To apply the multiple-wavelength (split-window) method used for satellite measurement of sea-surface temperature from thermal-infrared data to land-surface temperatures, the authors statistically analyze simulations using an atmospheric radiative transfer model. The range of atmospheric conditions and surface temperatures simulated is wide enough to cover variations in clear atmospheric properties and surface temperatures, both of which are larger over land than over sea. Surface elevation is also included in the simulation as the most important topographic effect. Land covers characterized by measured or modeled spectral emissivities include snow, clay, sands, and tree leaf samples. The empirical inverse model can estimate the surface temperature with a standard deviation less than 0.3 K and a maximum error less than 1 K, for viewing angles up to 40 degrees from nadir under cloud-free conditions, given satellite measurements in three infrared channels. A band in the region from 10.2 to 11.0 microns will usually give the most reliable single-band estimate of surface temperature. In addition, a band in either the 3.5-4.0-micron region or in the 11.5-12.6-micron region must be included for accurate atmospheric correction, and a band below the ozone absorption feature at 9.6 microns (e.g., 8.2-8.8 microns) will increase the accuracy of the estimate of surface temperature.

Wan, Zhengming↗

Mars Rover imaging systems and directional filtering

Computer literature searches were carried out at Duke University and NASA Langley Research Center. The purpose is to enhance personal knowledge based on the technical problems of pattern recognition and image understanding which must be solved for the Mars Rover and Sample Return Mission. Intensive study effort of a large collection of relevant literature resulted in a compilation of all important documents in one place. Furthermore, the documents are being classified into: Mars Rover; computer vision (theory); imaging systems; pattern recognition methodologies; and other smart techniques (AI, neural networks, fuzzy logic, etc).

Wang, Paul P.↗

Neutron stars and the distance to gamma-ray bursters

Assuming that gamma-ray bursts originate from galactic neutron stars, an analytic method for studying their statistical properties is outlined. If a significant fraction of all neutron stars are born with space velocities of less than approximately 100 km/s, as suggested by studies of pulsar statistics, then the sampling distance to gamma-ray burst sources should be less than about several hundred pc. These results have important implications on theories of radio-pulsar evolution and magnetic-field decay.

Dermer, Charles D.↗

Modes of formation of lunar light plains and the detection of cryptomaria deposits

The early volcanic and impact histories of the Moon are closely linked and the record preserved in surface morphology and samples is tightly convolved because of the interaction of the two processes. The deconvolution of the record is an important goal in order to assess early volcanic flux and the mode of emplacement of large crater and basin deposits. For example, lunar light plains have been variously interpreted as volcanic, impact, and volcanic covered by impact deposits. The development of criteria for the determination of the origin of light plains and the detection of cryptomaria is a key to the deconvolution of this early record. We outline the various hypotheses for the origin of and potential modes of occurrence of light plains and cryptomaria, and develop criteria for their recognition and documentation. We use the example of the Schiller-Schickard and Balmer cryptomaria to illustrate the application of these techniques to the problem of light plains interpretation and cryptomaria documentation.

Head, James W.↗