Towards robust and scalable dispatch modeling of long-duration energy storage
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
As the electrification of transportation expands, electric vehicle (EV) charging as residential loads will continue to grow. Residential EV charging has the potential to increase feeder peak loads and decrease voltage quality. As a result of this growing energy demand driven by EV, utilities may employ the use of smart charge management (SCM) controls to modify charging load profiles and mitigate these grid impacts. It is important that utilities understand both the potential benefits-as well as possible implementation challenges-before considering this technology as a solution to managing growing EV loads. In order for an SCM strategy to be an effective solution, the potential benefits must outweigh the implementation challenges. This study establishes and tests a novel framework to assess the implementation requirements of different SCM controls. It identifies a range of requirements specific to various SCM controls and implementation approaches to compare the relative challenges associated with the deployment of each. When paired with analysis on the effectiveness of the ability of each control to mitigate grid impacts from EV charging, this assessment is critical in comparing the value potential of different SCM controls.
Systems, methods, and computer media for managing frequency response in a power grid are provided herein. Individual grid-connected electrical devices can be turned on and/or off by corresponding frequency-responsive load controllers when frequency deviations beyond a threshold are detected. Each controller selects, for the corresponding electrical device, a frequency threshold from available frequencies in a frequency range. If the selected frequency falls within a deadband frequency range, then the controller sets the frequency threshold to a frequency outside of the deadband (e.g., to a closest available frequency outside of the deadband). On a system-wide level, this approximates a uniform distribution of frequency thresholds over the entire frequency range, including the deadband, and achieves the proper power-to-frequency relationship for grid stability. A supervisory coordinator can determine the frequency range from which a frequency threshold is selected based on aggregated power information for devices and controllers throughout the grid.
Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.
The increasing integration of renewable energy sources in modern power systems has led to a decline in system inertia, raising concerns about frequency stability following large disturbances. Determining critical inertia is essential to prevent excessive frequency decline and ensure grid stability. This paper evaluates four different methods for calculating critical inertia, using the Electric Reliability Council of Texas (ERCOT) system as a test case. The results highlight the importance of employing multiple methodologies to capture the full spectrum of inertia requirements.
The Advanced Grid Interactive Load Efficiency project team, led by Energy Northwest, was awarded funding as part of the fourth round of the Clean Energy Fund program to investigate, co-create, and complete a preliminary design for grid-interactive efficient buildings (GEBs) for a number of schools served by Grays Harbor PUD. The project team has evaluated different combinations of systems at selected school buildings and the potential to respond to grid and customer needs, and develop a preliminary system technical design, including specifying desired GEB technology options, determining communication and electrical interface requirements, assessing control software sensor requirements, and interfacing with building management systems. PNNL led the techno-economic assessment efforts, leveraging its advanced modeling and analytical methods and tools developed for building-to-grid integration. This report documents the economic assessment for different GEB design options, encompassing an in-depth examination of use cases and value propositions, assumptions and inputs, models, methods, case studies, as well as key findings.
This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.
Systems engineering today faces a wide array of challenges, ranging from new operational environments to disruptive technological — necessitating approaches to improve research and development (R&D) efforts. Yet, emphasizing the Aristotelian argument that the “whole is greater than the sum of its parts” seems to offer a conceptual foundation creating new R&D solutions. Invoking systems theoretic concepts of emergence and hierarchy and analytic characteristics of traceability, rigor, and comprehensiveness is potentially beneficial for guiding R&D strategy and development to bridge the gap between theoretical problem spaces and engineering-based solutions. In response, this article describes systems–theoretic process analysis (STPA) as an example of one such approach to aid in early-systems R&D discussions. STPA—a ‘top-down’ process that abstracts real complex system operations into hierarchical control structures, functional control loops, and control actions—uses control loop logic to analyze how control actions (designed for desired system behaviors) may become violated and drive the complex system toward states of higher risk. By analyzing how needed controls are not provided (or out of sequence or stopped too soon) and unneeded controls are provided (or engaged too long), STPA can help early-system R&D discussions by exploring how requirements and desired actions interact to either mitigate or potentially increase states of risk that can lead to unacceptable losses. This article will demonstrate STPA's benefit for early-system R&D strategy and development discussion by describing such diverse use cases as cyber security, nuclear fuel transportation, and US electric grid performance. Together, the traceability, rigor, and comprehensiveness of STPA serve as useful tools for improving R&D strategy and development discussions. In conclusion, leveraging STPA as well as related systems engineering techniques can be helpful in early R&D planning and strategy development to better triangulate deeper theoretical meaning or evaluate empirical results to better inform systems engineering solutions.
Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.
With the emergent need for clean and reliable energy resources, hybrid energy systems, such as the microgrid, are widely adopted in the United States. A microgrid can consist of various distributed energy resources, for instance, combined heat and power (CHP) systems. Here, the CHP module is a distributed cogeneration technology that produces electricity and recaptures heat generated as a by-product. It is an energy-efficient technology converting heat that would otherwise be wasted to valuable thermal energy. For an optimal system configuration, this study develops a novel co-design optimization framework for CHP-based cogeneration microgrids. The framework provides the stakeholder with a method to optimize investments and attain resilient operations. The proposed co-design framework has a mixed integer programming (MIP) model that outputs decisions for both plant designs and operating controls. The microgrid considered in this study contains six components: the CHP, boiler, heat recovery unit, thermal storage system, power storage system, and photovoltaic plant. After solving the MIP model, the optimal design parameters of each component can be found to minimize the total installation cost of all components in the microgrid. Furthermore, the online costs from energy production, operation, maintenance, machine startup, and disruption-induced unsatisfied loads are minimized by solving the optimal control decisions for operations. Case studies based on designing a CHP-based microgrid with empirical data are conducted. Moreover, we consider both nominal and disruptive operational scenarios to validate the performance of the proposed co-design framework in terms of a cost-effective, resilient system.
Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.
Long-duration energy storage (LDES) could play a pivotal role in the transformation of electricity grids with high shares of variable renewable energy (VRE) such as solar and wind. However, the weather-dependent nature of VRE introduces challenges for grid balancing and stability, which LDES - along with short-duration energy storage (SDES) - can help address. However, modeling LDES in production cost models (PCMs) is particularly challenging due to the need for high temporal resolution over extended optimization windows while preserving chronology, which ensures the alignment of energy storage operations with VRE generation over multi-day periods. This report compares traditional dispatch methods with advanced LDES dispatch strategies, such as the extended horizon approach, across different PCM platforms and examines tradeoffs and scalability. The comparison reveals that the traditional 1-day optimization horizon within the PCM leads to inefficient utilization of LDES. In contrast, extending the optimization horizon as much as possible significantly reduces curtailment and improves storage dispatch, especially in renewable-dense systems. There is also promise in using state-of-charge or end volume targets set by an external model, however this requires an additional modeling set and generally increases computational burden. This paper presents a comparison of these various methods in a number of power systems, showing algorithms initially in small test systems and scaling up to large, country-wide simulations. Overall, the research presents the trade-offs of various computational methods and illustrates how LDES may play an essential role in power systems of the future.
To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.
Abstract Electrifying the transportation sector is crucial for reducing greenhouse gas emissions and offers numerous benefits including increased energy efficiency, lower total ownership costs, enhanced national energy security, and improved air quality. Despite the availability of necessary technologies, fully integrating the transportation and electricity sectors presents challenges in understanding all benefits and risks. Previous studies have not highlighted the role of coupling between these sectors. To better understand this coupling, this work reviews the structure of the current fossil-fuel-based transportation sector (including its dependence on the electricity sector) and case studies of its vulnerabilities to key risks. By adopting a systemic perspective, we uncover the indispensable interplay between the transportation and electricity sectors, shedding light on previously neglected dynamics. Leveraging the principles of grid architecture (GA), we introduce a hierarchical approach to assess vulnerabilities within the prevailing fuel-based transportation system and elucidate pathways for enhancement through electrification.
Grid operators and electric utilities are increasingly driven to develop automated processes and introduce decision support tools to reduce cognitive demand on System Operations staff and aid in the operational decision-making process. However, System Operation staff are traditionally hesitant to implement and accept new solutions, automation processes, and tools within the control room. This paper explores high-value opportunities to advance automation in electric grid control rooms for the purpose of improving grid safety, reliability, and resiliency during normal and emergency operating conditions.
The attractive features of natural gas as well as the growing electric power demand worldwide have created increasing interest in natural-gas-based distributed generation applications for electric distribution networks. Here, this paper investigates the interdependency between a residential natural gas network and an electric distribution network that are linked together via fuel cells. The modeling of the natural gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the natural gas network and the electric distribution grid, subject to the constraints imposed by both networks. In addition, a probabilistic model for both gas and electricity demands is developed based on historical electricity and natural gas demand data. A K-means clustering method is used to determine the hourly load states to solve the joint probabilistic optimization problem. Simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution network and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.
Power outages have become increasingly frequent, intense, and prolonged in the US due to climate change, aging electrical grids, and rising energy demand. However, largely due to the absence of granular spatiotemporal outage data, we lack data-driven evidence and analytics-based metrics to quantify power system vulnerability. This limitation has hindered the ability to effectively evaluate and address vulnerability to power outages in US communities. Here, in this work, we collected ∼179 million power outage records at 15-min intervals across 3022 US contiguous counties (96.15 % of the area) from 2014 to 2023. We developed a power system vulnerability assessment framework based on three dimensions (intensity, frequency, and duration) and applied interpretable machine learning models (XGBoost and SHAP) to compute Power System Vulnerability Index (PSVI) at the county level. Our analysis reveals a consistent increase in power system vulnerability across the US counties over the past decade. We identified 318 counties across 45 states as hotspots for high power system vulnerability, particularly in the West Coast (California and Washington), the East Coast (Florida and the Northeast area), the Great Lakes megalopolis (Chicago-Detroit metropolitan areas), and the Gulf of Mexico (Texas). Our heterogeneity analysis indicates that urban counties and those located along regional transmission boundaries tend to exhibit significantly higher vulnerability. Our results highlight the significance of the proposed PSVI for evaluating the vulnerability of communities to power outages. The findings underscore the widespread and pervasive impact of power outages across the country and offer crucial insights to support infrastructure operators, policymakers, and emergency managers in formulating policies and programs aimed at enhancing the resilience of the US power infrastructure.
This report summarizes the work performed under a project funded by U.S. DOE Solar Energy Technologies Office (SETO) to use grid edge measurements to calibrate distribution system models for improved planning and grid integration of solar PV. Several physics-based data-driven algorithms are developed to identify inaccuracies in models and to bring increased visibility into distribution system planning. This includes phase identification, secondary system topology and parameter estimation, meter-to-transformer pairing, medium-voltage reconfiguration detection, determination of regulator and capacitor settings, PV system detection, PV parameter and setting estimation, PV dynamic models, and improved load modeling. Each of the algorithms is tested using simulation data and demonstrated on real feeders with our utility partners. The final algorithms demonstrate the potential for future planning and operations of the electric power grid to be more automated and data-driven, with more granularity, higher accuracy, and more comprehensive visibility into the system.