Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tuple checkout with notify in coordination namespace system

A system and method for notifying a process about a creation or removal event of a named data element (NDE) in a coordination namespace distributed memory system. A controller runs methods to: generate a tuple corresponding to data generated by a requesting process, the tuple having a tuple name and data value; and generate a notification indicator in a pending notification list to indicate to one or more processes a notification of the creation or removal event associated with the corresponding tuple. Upon detecting the event performed on the tuple by a second process, the method further searches for NDEs in the distributed memory system having the same tuple name, and in response to determining an existence of an associated pending notification record in a pending notification list of records, notify each corresponding process of the one or more processes indicated in the list of the creation or removal event.

Jacob, Philip↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation: Preprint

Utilities have been installing microgrids due to the advancements in the distributed energy resources technologies. Microgrids also improve the resiliency of the system due to their capability to isolate themselves from the grid and run in islanded mode of operation. Microgrid controllers are management systems that can run the microgrids under varied operating condition and enable the smooth operation of microgrids under various system conditions. It is of high value to de-risk the installation of such controllers. Hardware-in-the-loop evaluation is used by controller developers and utilities to evaluate the controllers under stressful conditions to understand the performance and to understand the necessary improvements to the microgrid controller. In this research work, the team has leveraged the existing infrastructure of real-time simulation at the Energy Systems Integration Facility (ESIF) and the capability of the microgrid controller to control assets over the Internet Protocol (IP) to evaluate a university developed microgrid controller in an efficient and cost-effective manner. The full paper will provide the complete setup, the experimental use cases and the results. In this abstract, one use case will be expalined, and the results from the use case is provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, Volt/VAr optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder-head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure (AMI)↗

Seamless Transition of Critical Infrastructures using Droop Controlled Grid-forming Inverters

Seamless recovery of power to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. Here, this article proposes a seamless transition strategy using a single and unified mode-dependent droop controlled grid-forming inverters. The control strategy achieves the following objectives: 1) regulates the output active and reactive power by the droop-controlled inverters to a desired value while operating in on-grid mode; 2) seamless transition and recovery of power injections into the load after grid failure by inverters that operates in grid-forming mode all the time; 3) requires only a single bit of information on the grid/network status for the mode transition. A framework for assessing the stability of the system and to guide the choice of parameters for controllers is developed using control-oriented modeling. A controller hardware-in-the-loop-based real-time simulation study on a test system based on the realistic electrical network of a commercial-scale medical center is conducted for initial prototyping of the control strategy. A hardware experiment is conducted with two 3 - $\phi$, 480 -V, 125 -kVA grid-forming inverters, a 3 - $\phi$, 480 -V, 270 -kVA grid simulator, a physical grid switch, and a physical load bank. The experimental data establishes the effectiveness of the always grid-forming operation and control of inverters in meeting power delivery objectives when on-grid and off-grid under various kinds of loads and scenarios while minimizing transients during transitions. Furthermore, performance comparison with existing strategies showcases the advantage of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Adaptive Neurocontrol for Grid-Following Inverters

The new generation of power systems involve a large number of autonomous operating units with the flow of data being restricted by privacy concerns or infrastructure hurdles. The systems are also time-varying so the control should adjust in a timely manner to avoid failures that usually have very negative economical implications. Adaptive neurocontrol which takes elements from adaptive control (great for time-varying problems) and model identification (could be in the form of neural network) by using local available data is a compelling tool. In this work, we summarize analytical results for adaptive neurocontrol, followed with numerical verification of how the method could work for future grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Upcycling waste PET into functional multiblock copolymers through controlled macromolecular design

Poly(ethylene terephthalate) (PET) oligomers derived from glycolysis depolymerization were converted into multiblock copolymers through diisocyanate-mediated coupling with dihydroxy-terminated oligomers, enabling precise control over copolymer sequence distribution, connectivity, and mechanical performance. Here, we demonstrate that telechelic PET oligomers isolated directly from depolymerized consumer waste can serve as reactive building blocks for the formation of segmented multiblock copolymers, eliminating the need to revert to monomeric feedstocks. Dihydroxy-terminated PET oligomers (Mw ≈ 8 kg mol−1) were coupled with poly(ethylene oxide) (PEO, Mw ≈ 4 kg mol−1) to form PET-PEO multiblock copolymers with high molar mass (Mw ≈ 160 kg mol−1). We further show that the timing of end-capping reactions provides a key control parameter that governs the competition between chain extension and termination, thereby dictating the resulting multiblock architecture and molecular-weight evolution. Evaluation of their mechanical properties reveals that virgin PET exhibits high modulus (∼3 GPa) and strength (43 MPa) but limited ductility (<10% elongation). In contrast, PET–PEO multiblock copolymers retain comparable tensile strength (44 MPa), albeit while exhibiting dramatically enhanced ductility (>90% elongation), forming tougher materials with efficient stress transfer between the rigid PET domains and the flexible PEO segments. When incorporated into PET/PEO blends at low loadings, the multiblock copolymers serve as effective compatibilizers, yielding materials with an intermediate modulus (1.1–1.2 GPa) and improved elongation compared to uncompatibilized blends. Furthermore, the presence of PEO blocks increases water uptake and gas permeability relative to virgin PET, reflecting the tunability of molecular transport through the copolymeric blocks. To our knowledge, this represents the first report of PET–PEO multiblock copolymers derived from post-consumer PET for gas transport applications. These results demonstrate that multiblock copolymer formation from telechelic PET oligomers provides a versatile platform for tailoring the mechanical and transport behavior of polyester-based materials through controlled macromolecular design and establishes a generalizable strategy for transforming consumer plastic waste into functional segmented polymers without requiring complete depolymerization to monomers.

Watson-Sanders, Shelby [Department of Chemistry, U↗

Geographically Dependent Sustainability Indicators for Comparison of Conventional Vegetable Production to Controlled-Environment Agriculture

Many food system lifecycle analyses distill agricultural production and supply chain impacts into single-value sustainability metrics for various food categories. These studies provide an overview of the food supply system that highlight striking results such as the GHG impacts of meat production. The supply chain impacts of vegetable production occupy the middle ground; higher than average food loss and waste, lower than average overall energy use, etc. However, aggregated results obscure the sustainability implications of the location of food production, especially for vegetables. Moreover, the increasing instability of food production systems are not captured, as illustrated by a recent Washington Post article. According to a UC Merced study conducted for the state, California farmers left nearly 400,000 acres of agricultural land unplanted last year because of a lack of water. The result, the study found, was a direct economic cost to farmers of $1.1 billion and the loss of nearly 9,000 agricultural jobs. (The Washington Post, March 21, 2022.) Previous work quantified the food-energy-water nexus implications of transitioning vegetable production from large, centralized agricultural operations to smaller distributed production in controlled-environment farms (CEA). The importance of location-specific data is especially evident for water use. Water impacts of the food system are primarily local to the region where food is produced, water impacts vary significantly between locations, and water stress is a major concern in locations that currently host large agricultural operations. Location-specific data is needed to accurately assess the water impacts of transitioning to CEA. The location of farms in relation to consumers impacts transportation energy use, food loss and waste, and requirements for food processing (e.g., to reduce weight, preserve foods for long storage, and package foods to reduce damage and loss) Reducing transport is particularly relevant for agricultural products that could be grown in CEAs (fruits, vegetables, protein). Access to nutritious food is not evenly distributed in the population. Remote communities, communities in harsh environments, and economically-disadvantaged communities often have poor access to healthy foods. CEA is ideally suited to these environments. However, the energy and water use of CEA, while in many respects lower overall than conventional supply chains, are concentrated within communities and could have significant local impacts. This paper reports on development of sustainability metrics that seek to capture the tradeoffs between the current supply chain and a CEA supply chain for vegetables; focusing on the location-dependent implications of water use, the transition from largely fossil fuel based energy use to electricity, and the food access, resilience and wellbeing implications of urban versus rural food production.

controlled-environment agriculture↗

A Mixed Integer Linear Programming-basedDistributed Energy Management for Three-phaseUnbalanced Active Distribution Network

A mixed integer linear programming (MILP)–baseddistributed energy management for three-phase unbalancedactive distribution network is proposed. Modern distributionnetworks have becoming more and more active with increasingdeployment of microgrids, distributed energy resources (DERs)as well as controllable loads. Considering various ownership andcontrol models of microgrids, DERs and controllable loads, adistributed energy management was formulated using the alternatingdirection method of multipliers (ADMM) algorithm. ByADMM, the distribution management system (DMS) and theseactive components are coordinated through price signals, whichare adjusted according to the generation-load mismatch per nodeper phase. To enable resolution of the ADMM-based distributedoptimization using more accessible and popular MILP solver,different linearization techniques were proposed to linearize theaugmented Lagrangian terms and other nonlinear terms. Resultsof case studies on a three-phase active distribution network withthree microgrids and several DERs and controllable loads validatedthe effectiveness of proposed MILP-based distributed energymanagement. In addition, the capability of proposed method inmitigating phase power unbalance has been demonstrated.

Liu, Guodong↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services: Preprint

This paper develops a hierarchical control fram-ework to aggregate and control behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. Even though the increasing penetration of DERs will strain the power networks in terms of voltage regul-ation and coordination issues with existing transmission-level conventional generators, the distribution-level DERs can also be utilized to help provide flexibility to the power network while providing cost savings to the DER owners. Therefore, this paper develops a model-predictive control strategy to determine the available power flexibility, and to utilize the flexibility in an aggregated form to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

14 SOLAR ENERGY↗

Multi-Edge Graph Convolutional Networks for Power Systems

The exponential electrification of transportation has contributed to highly intermittent load variations in the distribution grid. This uncertainty has raised challenges for distribution system operation and control. Accurate nodal voltage estimation is highly essential for the safe and reliable operation of the grid. Graph convolutional networks have been used in machine-learning-based models for power grid applications like voltage estimation for their ability to capture the network topology of the grid. This paper presents a novel multi-edge graph convolutional layer that considers resistance and reactance as edge attributes. This layer is created by modifying the message-passing function within the graph convolutional network. The novel layer is then used to create a multi-edge graph convolutional network-based surrogate model for estimating voltage in the distribution network with highly uncertain electric vehicle loads. Results indicate improved performance of the multi-edge graph convolutional network model when compared to a standard graph convolutional network model.

Ravi, Abhijith↗