Bridging Structural and Chemical Insights: Integrating In Situ Electron Microscopy and X-ray Spectroscopy for Catalysis Research

Environmental transmission electron microscopy probes the local structure, composition, and chemistry of materials under gas environments, while ambient-pressure X-ray photoelectron spectroscopy provides ensemble chemical and electronic structure information in gaseous conditions. Both techniques utilize similar differential pumping schemes to mitigate electron scattering by the gas phase, allowing for unique opportunities to correlate gas–surface interactions across comparable pressure ranges. Their integration has advanced the understanding of various catalytic reactions, including the water–gas-shift reaction, CO oxidation, and surface passivation dynamics. In conclusion, this Mini-Review discusses their methodological advancements, challenges, and potential for further integration with other in situ techniques to address complex catalytic phenomena and guide catalyst design.

36 MATERIALS SCIENCE↗

Potential of artificial intelligence in reducing energy and carbon emissions of commercial buildings at scale

Artificial intelligence has emerged as a technology to enhance productivity and improve life quality. However, its role in building energy efficiency and carbon emission reduction has not been systematically studied. This study evaluated artificial intelligence’s potential in the building sector, focusing on medium office buildings in the United States. A methodology was developed to assess and quantify potential emissions reductions. Key areas identified were equipment, occupancy influence, control and operation, and design and construction. Six scenarios were used to estimate energy and emissions savings across representative climate zones. Here we show that artificial intelligence could reduce cost premiums, enhancing high energy efficiency and net zero building penetration. Adopting artificial intelligence could reduce energy consumption and carbon emissions by approximately 8% to 19% in 2050. Combining with energy policy and low-carbon power generation could approximately reduce energy consumption by 40% and carbon emissions by 90% compared to business-as-usual scenarios in 2050.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

10 kV Class 14 MHz Isolated Power Supply

This paper presents a single-switch based isolated power supply, utilizing a PCB based core-less transformer to achieve high inter-winding isolation and low common-mode capacitance. Detailed design procedure, considering the transformer to achieve full range ZVS, minimize voltage stress and minimize RMS currents is presented. The proposed methodology is experimentally validated at 14 MHz, with a load variation of 10:1 in output power and a maximum output power of 4 W. The proposed power supply is useful in applications such as MV gate drives and sensors.

Tessaro Andrade, Elvey [ORNL] (ORCID:0009000225919↗

Integration of physiologically relevant photosynthetic energy flows into whole genome models of light‐driven metabolism

SUMMARY Characterizing photosynthetic productivity is necessary to understand the ecological contributions and biotechnology potential of plants, algae, and cyanobacteria. Light capture efficiency and photophysiology have long been characterized by measurements of chlorophyll fluorescence dynamics. However, these investigations typically do not consider the metabolic network downstream of light harvesting. By contrast, genome‐scale metabolic models capture species‐specific metabolic capabilities but have yet to incorporate the rapid regulation of the light harvesting apparatus. Here, we combine chlorophyll fluorescence parameters defining photosynthetic and non‐photosynthetic yield of absorbed light energy with a metabolic model of the pennate diatom Phaeodactylum tricornutum. This integration increases the model predictive accuracy regarding growth rate, intracellular oxygen production and consumption, and metabolic pathway usage. Through the quantification of excess electron transport, we uncover the sequential activation of non‐radiative energy dissipation processes, cross‐compartment electron shuttling, and non‐photochemical quenching as the rapid photoacclimation strategy in P. tricornutum. Interestingly, the photon absorption thresholds that trigger the transition between these mechanisms were consistent at low and high incident photon fluxes. We use this understanding to explore engineering strategies for rerouting cellular resources and excess light energy towards bioproducts in silico . Overall, we present a methodology for incorporating a common, informative data type into computational models of light‐driven metabolism and show its utilization within the design–build–test–learn cycle for engineering of photosynthetic organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Fabrication, Modeling, and Testing of a Prototype Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output year round; lithium-ion batteries are uneconomical at these durations. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (>1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A laboratory-scale silo prototype was built and validated the congruent transient finite element analysis (FEA) model. The performance of a commercial-scale silo was then characterized using the validated model. The commercial-scale model predicted a storage efficiency above 95% after 5 days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

clean energy↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

Development of a high-fidelity multi-cycle model of the NuScale small modular reactor using VERA

With growing renewables penetration, there is increased interest in flexible power operation for nuclear reactors. For multi-unit SMRs, in particular the NuScale SMR, which is an integral pressurized water reactor, there are opportunities to optimize flexible power operation across multiple units to limit the degradation of structural and control components. Here, we focus on degradation of in-core components, specifically the control rods and reactor pressure vessel. To perform these studies a high-fidelity, multi-cycle representation of the NuScale SMR is required, with a detailed representation of the structural and control components. To this end, the NuScale SMR has been modelled using the Virtual Environment for Reactor Applications (VERA) software. The entire transition to equilibrium is simulated, from Cycle 1 through to the equilibrium cycle. The equilibrium cycle model shows a good agreement with the NuScale design certification application (DCA) results, with differences attributable to a combination of using public domain data for the present study, and methodological differences. K-effective, power distributions, reactivity coefficients, and boron letdown curves are compared and all found to closely match. This shows that the VERA model is suitable for further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Addressing Human and Organizational Factors in Nuclear Industry Modernization: An Operationally Focused Approach to Process and Methodology

Utility owners and operators of commercial nuclear power plants in the United States (U.S.) are and will be modernizing their nuclear power plants by performing a digital transformation involving design of an integrated set of systems that together enable a technology centric operating plant. The Plant Modernization Pathway of the U.S. Department of Energy Light Water Reactor Sustainability Program has a strategic action plan that lays the groundwork for a digital transformation of the nuclear industry. The model for this transformation is an advanced concept of operations, with an end point vision, “To achieve the maximum aggregate benefit enabled by this digital transformation.” To achieve this, the digital infrastructure for a nuclear plant must be designed as an integrated set of systems that together enable a technology centric operating model. The digital transformation process obviously needs to involve technology considerations and systems engineering, but it also needs to include human and organizational expertise. Thus, human and organizational factors, including sociotechnical systems methods and techniques (e.g., Cognitive Systems Engineering, Systems Theoretic Accident Modeling and Processes, human systems integration, and Macroergonomics) need to be considered for digital transformation projects in order to effectively integrate human and organizational expertise efforts into the new work system that results from nuclear power plant digital modernization. That is, the work system is the basic unit of sociotechnical systems analysis and contains three components: personnel, technical, and organization and management. These components should be jointly optimized with respect to the interdependence of systems performance criteria of effectiveness, efficiency and safety. Joint optimization can be achieved through the application of three human and organization functions: knowledge representation, knowledge elicitation, and cross-functional integration. This report provides a strategic framework for effective integration of human and organizational expertise within nuclear power plant digital modernization efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flexible FlueCO2

Carbon dioxide (CO2) emission reductions remain a significant challenge on the path to clean energy. There are increasing legislative, social, and environmental factors motivating CO2 emissions reduction from power plants with carbon capture and storage (CCS). CCS in natural gas combined cycle (NGCC) power plants is critical to achieve a net-zero carbon electricity grid. Enhanced 45Q tax credits provide new incentives, but currently available technologies are unable to profitably operate in grids with deep variable renewable penetration which require flexible NGCC operation. Luna Labs has developed the FlueCO2 membrane to enable a profitable NGCC-CCS process. The FlueCO2 membrane couples steam transport across the membrane to CO2 transport in the opposite direction, enabling high capture efficiencies and low energy costs even at low CO2 concentrations. The dual-phase membrane can operate in the range of typical flue gas temperatures and pressures and does not require temperature or pressure cycling. Luna Labs’ FlueCO2 technology enables flexible and profitable operation of NGCC plants with lower capital investment and impact on electricity prices. In this Phase 1 project, Luna Labs utilized experimental testing, modeling, process simulation, and standardized costing methodologies to evaluate the techno-economic value of a 650 MW greenfield NGCC plant with FlueCO2 (NGCC-FlueCO2). Key design requirements for operation were established and plant performance under load-leveling conditions was validated through computational fluid dynamics and process modeling. Luna Labs developed a dynamic modeling tool which modeled plant operational modes across a variety of tax structures and electricity pricing scenarios to project the overall Net Present Value (NPV) of the NGCC-FlueCO2. FlueCO2 minimizes the impact of CCS integration on plant operation by integrating directly into the NGCC heat recovery steam generator (HRSG). By tapping into the plant’s low-pressure (LP) steam, operators can divert LP steam to the greenfield NGCC and/or CCS process in response to dynamic markets. Since FlueCO2 will not significantly affect HRSG (or NGCC) operation, CCS only turns off during peak power demand (>$250/MWh). Under baseload conditions, FlueCO2 lowers the capital (37%), energy (36%) and carbon capture (<$40/tonne) costs and can increase the overall plant lifetime NPV by approximately ~$1B in comparison with NGCC solvent-based capture reference cases (NETL Case 31B). Luna Labs has shared its costing tools with several interested partners and customers, which follows a generalizable approach to costing analysis.

Kelly, Jesse↗

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Robotic Planning under Uncertainty in Spatiotemporal Environments in Expeditionary Science

In the expeditionary sciences, spatiotemporally varying environments -- hydrothermal plumes, algal blooms, lava flows, or animal migrations -- are ubiquitous. Mobile robots are uniquely well-suited to study these dynamic, mesoscale natural environments. We formalize expeditionary science as a sequential decision-making problem, modeled using the language of partially-observable Markov decision processes (POMDPs). Solving the expeditionary science POMDP under real-world constraints requires efficient probabilistic modeling and decision-making in problems with complex dynamics and observational models. Previous work in informative path planning, adaptive sampling, and experimental design have shown compelling results, largely in static environments, using data-driven models and information-based rewards. However, these methodologies do not trivially extend to expeditionary science in spatiotemporal environments: they generally do not make use of scientific knowledge such as equations of state dynamics, they focus on information gathering as opposed to scientific task execution, and they make use of decision-making approaches that scale poorly to large, continuous problems with long planning horizons and real-time operational constraints. In this work, we discuss these and other challenges related to probabilistic modeling and decision-making in expeditionary science, and present some of our preliminary work that addresses these gaps. We ground our results in a real expeditionary science deployment of an autonomous underwater vehicle (AUV) in the deep ocean for hydrothermal vent discovery and characterization. Our concluding thoughts highlight remaining work to be done, and the challenges that merit consideration by the reinforcement learning and decision-making community.

Preston, Victoria↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MARVEL Instrumentation, Control, and Software Considerations

This paper details the various I&C considerations and design decisions made throughout the MARVEL (Micro-reactor Applications Research Validation and Evaluation) project, including sensor and actuator selection, safety-related functionality, digital control hardware and software, and testing methodologies. Key challenges such as managing radiation, temperature, and space constraints are discussed, along with the trade-offs between using standard equipment and custom solutions. The successful integration of off-the-shelf components, the emphasis on minimizing safety-related instrumentation, and the lessons learned from prototyping and testing are highlighted. The authors aim to provide insights that can benefit future micro-reactor designs and emphasize the importance of real-world testing in advancing reactor technology.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

From Well Log to Formation Model: A Novel Laboratory Calibrated Methodology with Demonstration

This work demonstrates how the characterization and modeling of both elastic and creep properties are essential to describe zones in layered rock formations as either low-stress targets for stimulation or high-stress barriers to fracture growth. Prediction of fracture height is critical for designing stimulation operations in oil and gas wells. Ideally, fractures are placed in target zones which will produce hydrocarbons and should not propagate into zones expected to be unproductive or to produce unwanted fluids such as water which in turn must be treated and/or disposed. The essential task in designing stimulation plans is predicting which zones have low horizontal stresses and which will be high-stress barriers to fracture growth. Despite this importance, there are gaps in current knowledge and a complete workflow from laboratory characterization to a finite element model which includes time dependent rock deformation is required. While the research and methodology presented here also have application to CO 2or hydrogen storage, wastewater injection, and geothermal applications, the focus will be on hydrocarbon extraction. This thesis presents the results of a characterization-to-prediction workflow for the Caney shale, which is an emerging hydrocarbon resource in Oklahoma, USA. It begins with an investigation to enable critical evaluation of the Caney zonation into nominally “brittle” and “ductile” zones based on properties observed from well logs. It shows none of the zones are consistently “brittle” or “ductile” mechanical behavior based on the variety of definitions of these terms. However, the nominally ductile zones are weaker and more prone to creep. A laboratory investigation of samples including strength, elastic, and creep properties, is then used in a finite element model of stress evolution. The model includes both elastic deformation and viscoplastic creep. Results predict the least creep-prone layers to have the lowest horizontal stresses, therefore comprising hydraulic fracturing targets. The most creep-prone layers attain a horizontal stress similar to the vertical stress and therefore are predicted to be high stress barriers to hydraulic fracture stimulation. In addition to defining stimulation target intervals, the model shows how as tectonic strain rate increases, there is a transition from creep-dominated stresses to stresses dominated by elasticity.

Benge, Margaret↗

Graph Theory and IC Component Design Analysis

Graph analysis in large integrated circuit (IC) designs is an essential tool for verifying design logic and timing via dynamic timing analysis (DTA). IC designs resemble graphs with each logic gate as a vertex and the conductive connections between gates as edges. Using DTA digital statistical correlations, graph condensation, and graph partitioning, it is possible to identify high-entropy component centers and paths within an IC design. Identification of high-entropy component centers (HECC) enables focused DTA, effectively lowering the computational complexity of DTA on large integrated circuit graphs. In this paper, a devised methodology termed IC layout subgraph component center identification (CCI) is used to identify described. CCI lowers DTA computationally complexity by condensing IC graphs into reduced subgraphs in which dominant logic functions are verified.

42 ENGINEERING↗

Active learning of chemical reaction networks via probabilistic graphical models and Boolean reaction circuits

Discerning networks of many reactions among multiple interconverting species is challenging. Here, we present a reaction network identification methodology. Our methodology enumerates all stoichiometrically and chemically feasible reactions and requires statistical evidence from effluent concentrations for the inclusion or exclusion of each from the reaction network, contrasting with the commonly seen incremental approach and other work of relying heavily upon chemical intuition and assuming the reactions occurring. Using graph theory alongside an active learning design of experiments that propose maximally informative feeds, we identify the underlying reaction network with minimal laboratory runs. Here, we introduce chemistry-probabilistic graphical modeling and Boolean reaction circuits to statistically quantify which reactions occur from effluent concentrations. Our methodology accurately discerns active reactions, as showcased upon a laboratory network of cross-ketonization of furoic and lauric acid and validated upon simulated networks of thermal and CO 2 -assisted ethane dehydrogenation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuum Damage Mechanics Modeling of High-Temperature Flaw Propagation: Application to Creep Crack Growth In 316H Standardized Specimens and Nuclear Reactor Components

Predicting creep crack growth (CCG) of flaws found during operation in high-temperature alloy components is essential for assessing the remaining lifetime of those components. While defect assessment procedures are available for this purpose in design codes, these are limited in their range of applicability. This study assesses the application of a local damage-based finite-element methodology as a more general technique for the prediction of CCG at high temperatures on a variety of structural configurations. Numerical results for stainless steel 316H, which are validated against experimental data, show the promise of this approach. This integration of continuum damage mechanics (CDM) based methodologies, together with adequate inelastic models, into assessment procedures can therefore inform the characterization of CCG under complex operating conditions, while avoiding excessive conservatism. This article shows that such modeling frameworks can be calibrated to experimental data and used to demonstrate that the degree of tri-axiality ahead of a growing creep crack affects its rate of growth. The framework is also successfully employed in characterizing CCG in a realistic reactor pressure vessel geometry under an arbitrary loading condition. These results are particularly relevant to the nuclear power industry for defect assessment and inspections as part of codified practices of structural components with flaws in high-temperature reactors.

42 ENGINEERING↗

The Importance of Addressing Disagreements Between Nominal and Effective Treatments During Bat Mortality Minimization Validation Studies

As the wind energy industry grows, so too does our need for effective and low-cost bat mortality minimization solutions. Despite knowledge gaps in our understanding of what drives bats to collide with spinning turbines, minimization solutions have shown success during validation studies. Curtailment has been consistently effective, reducing bat mortality from 33%-79%, depending on the curtailment scenario and species present. Several validation studies have demonstrated deterrent solutions, specifically ultrasonic deterrents, to be effective, but overall, more variable compared to curtailment solutions. Further, a study combining curtailment with ultrasonic deterrents produced encouraging results, finding that adding ultrasonic deterrents to turbines that were designated to curtail, significantly reduced mortality rates compared to curtailment only turbines. Despite positive results, the strength of inference achieved with validation studies is limited by methodological constraints associated with appropriately assigning fatalities to treatments. Because of the temporal separation between when a bat collides with a turbine and when it is discovered during a ground-based carcass survey, we must assign carcasses to a treatment that ran during the prior night(s). This process may introduce errors at multiple stages. First, for studies that rotate treatments among turbines, mortality surveyors must be confident that carcasses are 'fresh' such that mortalities are correctly assigned to the treatment from the previous night(s). Second, we must reconcile any misalignments between how we assign treatments and how we implement treatments (e.g., turbines assigned with a deterrent treatment may be implemented as another treatment when deterrent devices are not operating as designed). Finally, for curtailment solutions, it is critical to recognize that measured effects are a function of not just the treatment as implemented but the proportion of the night the treatment is realized (e.g., if wind speeds are greater than the curtailment treatment cut-in speed for the entire night, we cannot expect there to me any differences in mortality reduction relative to control turbines). Using a dataset collected between June and October 2017, that rotated 3 treatments (Deterrent Only, 5 m/s Curtail only, and 5 m/s Curtail & Deterrent) and 1 control condition across 16 turbines each night, we explored the importance and implications of accounting for potential errors in assigning fatalities to treatments. We present preliminary results comparing the mortality associated with error-corrected treatments and control conditions highlighting how the measured effect of a treatment (mortality) greatly depends on site specific implementation.

bats↗