Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Preparation of: I. intercalative metal oxide/conductive polymer composites as electrode materials for rechargeable batteries; II. sodium rich manganese oxide hydrate with capacity for aqueous Na-ion electrochemical energy storage

The present invention is directed at intercalative metal oxide/conductive polymer composites suitable for use as electrode materials for rechargeable batteries. The composites can be prepared by agitation of the metal oxide and the conductive polymer in aqueous media. The present invention is also directed at a sodium rich layered manganese oxide hydrate prepared by annealing manganese (II, III) oxide and sodium hydroxide. The sodium rich manganese (III, IV) oxide so formed indicates an enhanced capacity for Na-ion storage suitable for the use of electrode materials for aqueous energy storage.

Xiaowei, Teng↗

Multinonmetal-Doped V 2 O 5 Nanocomposites for Lithium-Ion Battery Cathodes

Lithium-ion batteries (LIBs) are critical for portable electronics and electric vehicles, demanding higher energy density to meet increasing energy storage needs. Current commercial cathode materials, such as LiFePO 4 and LiCoO 2 , are limited by a single electron transfer, restricting their energy density. Vanadium pentoxide (V 2 O 5 ) emerges as a promising high-capacity cathode due to its high theoretical capacity of 443 mA h g –1 with three Li storage capacities, significantly surpassing conventional materials. However, the practical application of V 2 O 5 is hindered by a large structural evolution and rapid capacity fading during full lithium intercalation. Here, this study introduces a multinonmetal doping (MNM) strategy to enhance V 2 O 5 cathodes by incorporating all-nonmetal dopants (B, P, and Si) and graphene (G). MNM-V 2 O 5 -G exhibits increased surface oxygen defects, improving charge transfer kinetics and thus enhancing the rate performance and cycling stability. Our results provide valuable insights into the role of surface oxygen defects in stabilizing V 2 O 5 with element doping. This research highlights the potential of multinonmetal doping to improve LIB cathode materials, offering a promising pathway for design of high-energy-density V 2 O 5 cathodes and advancing the development of next-generation energy storage solutions.

25 ENERGY STORAGE↗

Reversible hydrogen storage in multilayer graphane: Lattice dynamics, compressibility, and heat capacity studies

Multilayer graphane (hydride of graphite) is a crystalline hydrocarbon of composition CH, which can be synthesized from graphite and molecular hydrogen at pressures above 2GPa [V.E. Antonov et al. Carbon 100 (2016) 465]. Using X-ray diffraction, this compound was tentatively identified as the “graphane II” phase of 3D-graphane predicted by ab initio calculations [X.-D. Wen et al. PNAS 108 (2011) 6833] and consisting of layers of 2D-graphane in the “chair” conformation. When heated in a vacuum, the compound does not form any intermediate hydrocarbons and reversibly decomposes back into graphite and hydrogen at 770–920 K. In the present work, almost single-phase samples of graphite hydride and deuteride were synthesized at 7.4 GPa and 870 K. Their investigation by inelastic neutron scattering supplemented by ab initio calculations gave spectra g(E) of the phonon density of states with a gap of about 15 meV at approx. 100 meV, which is a unique identifier for the chair form of graphane. The equation of state V(P) of the hydride was studied at room temperature and hydrogen pressures up to 53 GPa by synchrotron X-ray diffraction in a diamond anvil cell. Further, the graphane II phase did not react with the surrounding hydrogen and did not undergo any phase transformations upon the compression and after heating to 1500 K at 53GPa. The high thermal and pressure stability of this exotic phase makes it an important part of the C–H system. The obtained g(E) spectra of graphite hydride and deuteride were used to calculate temperature dependences of their heat capacity. Measurements of the heat capacity at temperatures 120–673 K confirmed the good accuracy of these calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

Analysis of cryogenic propellant logistics.

Large launch vehicle cryogenic propellant logistics including storage and production capacity optimization, cost and heat loss analyses by computer simulation

PROPELLANT STORAGE↗

Adsorption of Natural Gas in Metal–Organic Frameworks: Selectivity, Cyclability, and Comparison to Methane Adsorption

Evaluation of metal–organic frameworks (MOFs) for adsorbed natural gas (ANG) technology employs pure methane as a surrogate for natural gas (NG). This approximation is problematic, as it ignores the impact of other heavier hydrocarbons present in NG, such as ethane and propane, which generally have more favorable adsorption interactions with MOFs compared to methane. Herein, using quantitative Raman spectroscopic analysis and Monte Carlo calculations, we demonstrate the adsorption selectivity of high-performing MOFs, such as MOF-5, MOF-177, and SNU-70, for a methane and ethane mixture (95:5) that mimics the composition of NG. The impact of selectivity on the storage and deliverable capacities of these adsorbents during successive cycles of adsorption and desorption, simulating the filling and emptying of an ANG tank, is also demonstrated. Finally, the study reveals a gradual reduction in the storage performance of MOFs, particularly with smaller pore volumes, due to ethane accumulation over long-term cycling, until a steady state is reached with substantially degraded storage performance.

03 NATURAL GAS↗

Electrical characterization of the Magellan batteries after storage

Two 22 cell batteries designed by Martin Marietta were tested. The batteries were rated at 26.5 Amp-Hr. The battery design is characterized by the following: Gates Aerospace 42B030AB15, 11 pos/12 neg, Pellon 2536 separator, passivated pos/teflonated neg. The tests can be summarized as follows: (1) no noticeable capacity loss after storage period; and (2) batteries exhibited larger non-uniformity of cell voltages during constant current charge.

Deligiannis, Frank↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Effects of Deep Reductions in Energy Storage Costs on Highly Reliable Wind and Solar Electricity Systems.

We use 36 years (1980-2015) of hourly weather data over the contiguous United States (CONUS) to assess the impact of low-cost energy storage on highly reliable electricity systems that use only variable renewable energy (VRE; wind and solar photovoltaics). Even assuming perfect transmission of wind and solar generation aggregated over CONUS, energy storage costs would need to decrease several hundred-fold from current costs (to ~$1/kWh) in fully VRE electricity systems to yield highly reliable electricity without extensive curtailment of VRE generation. The role of energy storage changes from high-cost storage competing with curtailment to fill short-term gaps between VRE generation and hourly demand to near-free storage serving as seasonal storage for VRE resources. Energy storage faces "double penalties" in VRE/storage systems: with increasing capacity, (1) the additional storage is used less frequently and (2) hourly electricity costs would become less volatile, thus reducing price arbitrage opportunities for the additional storage.

14 SOLAR ENERGY↗

CO 2 /Brine/Rock Interactions in the Cedar Keys-Lawson Formation

It has been reported that among the various geologic storage options, deep saline aquifers have the largest estimated capacity for CO 2 storage. Obtaining knowledge of possible artificially geochemically induced changes to the permeability and porosity of host CO 2 storage deposits will enable us to gain insight on long-term reservoir behavior under CO 2 storage conditions. An experimental study of the interaction of CO 2 /brine/rock on saline formations was conducted in a static system under CO 2 storage conditions. Chemical interactions in the Cedar Keys-Lawson Formation carbonate during exposure to CO 2 and brine under sequestration conditions were studied. Samples were exposed to the simulated in-situ reaction conditions for one and six months. The samples were exposed to a model brine at 55 °C and CO 2 pressure of 23.8 MPa (3,500 psig). Computed tomography (CT), x-ray diffraction (XRD), scanning electron microscopy (SEM)-energy dispersive x-ray spectroscopy (EDS), brine composition, core porosity, and core permeability analyses were conducted prior to and after the exposure experiments. Preliminary permeability measurements obtained from the core samples showed changes after they were exposed to CO 2 -saturated brine for one and six months. This observation suggests that mineral dissolution and mineral precipitation could occur in the host deposit altering its characteristics for CO 2 storage over time. The 3D images of the pore space clearly illustrate the degree of dissolution that occurred during exposure. It is noted that the dissolution that occurred during the six-month exposure could have enhanced the connectivity between voids. This may contribute the increase of permeability after the CO 2 /brine exposure. In addition, the primary minerals comprising the core are dolomite and gypsum. Both minerals could dissolve in the CO 2 /brine environment resulting in the increase of permeability after the six-month exposure.

58 GEOSCIENCES↗

The Bess-Polar II Long Duration Flight Above Antarctica

The Balloon-borne Experiment with a Superconducting Spectrometer, BESS, has been developed to study elementary particle phenomena in the early universe through measurements of low energy antiprotons to investigate their origin and through a search for antihelium. The BESS collaboration carried out nine northern latitude flights between 1993 and 2002. BESS-Polar is an advanced program of the BESS collaboration to study these topics with much greater precision using long duration flights above Antarctica. The BESS-Polar spectrometer was successfully developed to accumulate much larger numbers of events during long duration flights around the South Pole. Approximately a factor of four reductions in the amount of material in the particle beam enables measurement of much lower energy antiprotons down to 100 MeV (at top of atmosphere). The first BESS-Polar flight (BESS-Polar I) of 8.5 days was carried out above Antarctica in December 2004. recording 900 million cosmic-ray events. The second BESS-Polar flight (BESS-Polar 11) was successfully carried out in the austral summer season of 2007-2008. Based on experience with BESS-Polar I, the spectrometer was improved in performance and achieved long term stability during the flight. A newly constructed magnet with a larger liquid He capacity and improved thermal insulation and an upgraded data storage system with larger capacity of hard disk drives (HDDs) enabled longer observation time. BESS-Polar II was launched on December 22, 2007 from Williams Field, McMurdo Station, in Antarctica. The spectrometer worked properly and observed cosmic rays for about 24.5 days at float altitude, recording 4.6 billion events on the HDDs until the limit of the magnet operation was reached on January 16, 2008. The flight was terminated and the spectrometer was safely landed on the West Antarctic ice sheet (1000 km from the South Pole) on January 21, 2008. Here, the BESS-Polar instrument is discussed, highlighting improvements made for BESS-Polar II, and overviews of the flight and performance are reported.

Sasaki, Makoto↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Space Exploration Applications for Development of High Capacity Cryocoolers

Long term storage of cryogens is necessary to enable NASAs long duration crewed missions to both the lunar and Martian surfaces. Such missions require in-space transport systems such as Nuclear Thermal Propulsion (NTP), and descent/ascent vehicles for transportation to and from the lunar and Martian surfaces. NTP systems and Lunar/Martian landers utilize cryogenic fluids to minimize architectural volume and mass. To further enhance the capability of these cryogenic systems, the Agency is putting emphasis on reusability, which requires the NTP and ascent/descent elements be replenished on-orbit via tankers or propellant depots, or on the lunar or Martian surface using liquefied in-situ produced propellants. NTP is one of the leading propulsion option for human Mars missions and requires liquid hydrogen to be stored on-orbit for over four years. For such a long duration mission, near “Zero Boil-Off” (ZBO) must be achieved which requires an optimized suite of passive Cryogenic Fluid Management technologies and active cooling (cryocoolers). Tens of Watts of 20K cooling is required to achieve ZBO conditions for NTP, however two-stage cooling using both 20K and 90K systems can lead to a significant reduction in both active cooling mass and power. The use of in-situ resources for lunar and Martian missions will require 150 Watts of 90K cooling for oxygen liquefaction and 300 Watts of 20K cooling for hydrogen liquefaction (lunar only). Descent/Ascent vehicles, propellant depots, and tankers will also require the use of cryocoolers to achieve ZBO conditions. To support these programs, NASA is developing high capacity 20K and 90K reverse turbo-Brayton cycle cryocoolers which offer a scalable, high efficiency, low vibration solution.

cryocooler↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design analysis of a particle-based thermal energy storage system for concentrating solar power or grid energy storage

Energy storage is becoming indispensable for expanding renewable energy integration, and it is critical to the future low-carbon energy supply. Large-capacity, grid scale energy storage can support the integration of solar and wind power and support grid resilience with the diminishing capacity of baseload fossil power plants. With the development of thermal energy storage (TES) for concentrating solar power systems, standalone TES for grid integration becomes attractive due to the declining renewable generation cost and an increasing need for energy storage. The standalone TES system introduced in this paper can play a big role in the carbon-free energy future with capacity larger than batteries and cost likely lower than other energy storage methods such as pumped storage hydropower and compressed air energy storage, both of which also have geological limitations. To this end, we describe a TES system that uses stable, inexpensive solid particles as a TES media to provide scalable, low cost energy storage. The particle-based TES has the ability to drive various thermal power cycles including conventional steam-Rankine, air Brayton turbine with combined-cycle ability, or the emerging supercritical carbon dioxide Brayton power cycle. This work describes the containment design method including a concrete silo and an internal-insulation layer for the particle-TES system. The economic analysis shows significantly low storage cost when the particle-TES is integrated with Brayton combined-cycle power generation. The paper shows the design approach of the particle-TES system and its economic potential for bulk energy storage. The advantage of the particle-TES system as a promising bulk energy storage method is its ability to economically support dispatchable renewable grid penetration for larger capacity and longer discharging hours than current battery storage technologies.

25 ENERGY STORAGE↗

Advances and perspectives of hard carbon anode modulated by defect/hetero elemental engineering for sodium ion batteries

Sodium-ion batteries (SIBs) serve as a promising complement to lithium-ion batteries for large-scale energy storage, leveraging the abundance of sodium resources and notable safety advantages. The key advancement in SIB industrialization hinges on identifying a cost-effective and high-performance anode material, similar to the graphite anode in lithium-ion batteries. Hard carbon emerges as prime anode materials for SIBs, boasting high specific capacity, low sodium storage potential, and wide availability. However, practical applications of hard carbon encounters challenges such as low initial Coulombic efficiency (ICE), inadequate long-term cycling stability, and poor rate performance. Recent research has focused on the optimization of hard carbon electrodes through functional design. In this comprehensive review, we have meticulously examined the progress in enhancing sodium storage performance through microstructural modulation within hard carbon, encompassing four pivotal aspects: heteroatom doping, incorporation of oxygen functional groups, surface coating, and intrinsic defect engineering. Progress in implementing these strategies is scrutinized, while the merits and challenges of each defect engineering approach are discussed. In conclusion, this review also looks into forthcoming opportunities and challenges in the practical application process of hard carbon electrodes in SIBs.

25 ENERGY STORAGE↗

Gas storage using fullerene based adsorbents

This invention is directed to the synthesis of high bulk density high gas absorption capacity adsorbents for gas storage applications. Specifically, this invention is concerned with novel gas absorbents with high gravimetric and volumetric gas adsorption capacities which are made from fullerene-based materials. By pressing fullerene powder into pellet form using a conventional press, then polymerizing it by subjecting the fullerene to high temperature and high inert gas pressure, the resulting fullerene-based materials have high bulk densities and high gas adsorption capacities. By pre-chemical modification or post-polymerization activation processes, the gas adsorption capacities of the fullerene-based adsorbents can be further enhanced. These materials are suitable for low pressure gas storage applications, such as oxygen storage for home oxygen therapy uses or on-board vehicle natural gas storage. They are also suitable for storing gases and vapors such as hydrogen, nitrogen, carbon dioxide, and water vapor.

Loutfy, Raouf O.↗