Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Investigating a Renewable-Resource-Targeting Mobile Aquaculture System Using Route Optimization Based on Optimal Foraging Theory

Aquaculture systems require careful consideration of location, which determines water conditions, pollution impacts, and hazardous conditions. Mobility may be able to address these factors while also supporting the targeting of renewable energy sources such as wind, wave, and solar power throughout the year. In this paper, a purpose-built mobile aquaculture ship is identified and modeled with a combination of renewable energy harvesting capabilities as a case study with the objective of assessing the potential benefits of targeting high renewable energy potentials to power aquaculture operations. A route optimization algorithm is created and tuned to simulate the mobility of the aquaculture platform and cost-basis comparisons are made to a stationary system. The small spatial variability in renewable energy potential when combining multiple resources significantly limits the benefits of a mobile, renewable-targeting aquaculture system. On the other hand, the consistent energy harvest from a blend of renewable energy types (13 kW installed wind capacity, 661 m 2 installed solar, and 1 m characteristic width wave-energy converter) suggests that the potential benefits of a mobile platform for offshore aquaculture (mitigation of environmental and social concerns, any potential positive impact on yields, hazard avoidance, etc.) can likely be pursued without significant increases in energy harvester costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The role of ferrites in wireless charging systems for electric vehicles

This review examines the critical role of magnetic ceramic ferrites in wireless charging systems (WCS) for electric vehicles (EVs). With the increasing shift towards electrifying motor vehicles, advanced charging systems are needed to optimize EV range and performance. Magnetic materials are vital in WCS, as they act as a coupler that enhances power transfer. However, design limitations in weight and size motivate the need for systems tailored to meet a range of specifications. Additionally, ferrite systems can be tailored by altering composition, microstructure, and processing. Furthermore, this review examines advanced manufacturing techniques for improved ferrite design and identifies future directions for ferrite core research to meet future WCS needs.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Power Generation Enhancement through Latching Control for a Sliding Magnet-Based Wave Energy Converter

A Surface-Riding Wave Energy Converter (SR-WEC) featuring a sliding magnet inside a pitching cylindrical hull is investigated as an easily deployable small power device to support small-scale marine operations. This study extends the earlier development of the system by authors to enhance power performance through the application of end spring and latching control. The inclusion of springs at the tube’s end enhances the magnet release and travel speeds as well as the average power output compared to systems without them. Further improvement of power output can also be achieved by employing optimal latching control. We introduced constant-angle and variable-angle unlatching strategies to determine optimal parameters in combination with passive and reactive power take-off (PTO) controls to assess their effectiveness. The optimized latching control and end spring can increase 60–80% more power output compared with the case without them under certain PTO damping. Additionally, we discussed the effects of limiting peak powers and associated energy leaks with latching.

Lee, Yongseok↗

Implementation of a High-Fidelity Interface Resolving Method in Nek5000

The development and utilization of computational fluid dynamics (CFD) models for large, high-temperature electric melters in the Waste Treatment and Immobilization Plant (WTP) in eastern Washington State have proven to be valuable for various purposes. These models allow for a better understanding of the physio-chemical processes occurring within the melter vessels and can contribute to improving operational efficiency, throughput, and addressing operational issues related to vitrification. The CFD models employed for these melter vessels incorporate multiphase fluid flow and heat transfer simulations in different regions, including the plenum, cold cap, and molten glass regions. As the tank waste and glass formers are introduced into the melter, a reacting batch layer known as the cold cap forms on top of the molten glass. To enhance the melt rate, forced convection bubblers located at the bottom of the melters generate convection currents that help homogenize the molten glass and provide heat to the cold cap. As the bubbles rise through the highly viscous glass, they adopt a spherical-cap shape [1]. Meanwhile, the conversion of the batch to glass generates significant amounts of gases (such as water vapor, carbon dioxide, sulfur dioxide, and NOx) due to thermal decomposition [2]. These gases become trapped between the cold cap and molten glass, forming a foam layer [3]. For modeling multiphase flow in CFD and heat transfer simulations of waste glass melters at different scales, efforts are underway to augment the capabilities of the Nek5000 [4] and NekRS [5] open-source codes [6]. Nek5000/NekRS is a scalable and efficient spectral element code that has been successfully applied to a wide range of fluid dynamics problems. By leveraging the Nek5000/NekRS software, it becomes possible to model the melter systems more affordably and with lower computational requirements compared to currently utilized commercial CFD software. The specific objectives of this ongoing effort include: 1. Implementation of a level set method in Nek5000/NekRS: The level set method is a numerical technique commonly employed in CFD simulations to track and represent the interface between different phases or materials accurately. By incorporating this method into Nek5000/NekRS, the ability to simulate multiphase flows in waste glass melters at a high level of fidelity can be achieved. 2. Demonstration of capability for air bubbling through molten glass: As part of the development process, a specific case of air bubbling through molten glass will be simulated using the augmented Nek5000/NekRS code. This demonstration aims to showcase the ability of the software to accurately capture and analyze the complex phenomena involved in the multiphase flow within waste glass melters. By achieving these objectives, the improved Nek5000/NekRS code will offer a powerful computational tool for simulating and analyzing waste glass melter systems, enabling better understanding, optimization, and troubleshooting of these vitrification processes. The ability to accurately model and simulate multiphase flows has broad relevance across many industries and scientific domains, and the improved functionality can contribute to advancements in various fields beyond waste glass melter simulations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Networked Microgrid Optimal Design and Operations Tool: Regulatory and Business Environment Study

Microgrids aim to increase the resilience of the electric supply to the loads within the microgrid through the ability to disconnect from the distribution utility in the event of a power outage and by supplying power to the microgrid loads from a combination of multiple power generation assets and storage systems. Microgrids can also improve reliability at the distribution level by reducing the load on the system under stress conditions. Networking two or more microgrids has the potential to increase reliability and resilience at a reduced cost by taking advantage of economies of scale and increasing the diversity of the generation assets and loads. This report is part of a collaborative effort among several U.S. Department of Energy national laboratories to develop a networked microgrid (NMG) Optimal Design and Operations (OD&O) tool. This tool addresses the goal defined in the Grid Modernization Multi-Year Program Plan to develop a suite of tools that addresses functional requirements for system optimal design and the operations of NMGs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Optimization, and Control of a 100 kW Electric Traction Motor Meeting or Exceeding DOE 2025 Targets

The overall objective of the electric motor portion of the Electric Drives Technology consortium is to research, develop, and test electric motors for use in electric vehicle applications capable of a peak power greater than 100 kW, power density greater than or equal to 50 kW/l, and a cost less than 3.3 $/kW. To meet the electric traction motor power density and cost targets a number of approaches were pursued simultaneously throughout the course of this project which address all of the major volumetric power density variables. The specific research thrusts at the Illinois Institute of Technology (IIT) are the following: multiphysics design for increased power density through maximum utilization of active materials, synthesis of electric machine windings and PM flux barriers with controlled space harmonics, high slot fill windings for increased current loadings or efficiency, aggressive cooling strategies, and design studies and prototype construction of candidate electric machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Auxiliary Circuit Elements for Achieving Zero Voltage Switching in a Wireless Power Transfer System

The auxiliary resonant commutated pole (ARCP) is being used to achieve zero voltage switching (ZVS) of power switches for improved efficiency and/or to reduce dv/dt at the switch node for better electromagnetic interference (EMI) performance and overall system reliability. This paper shows how an ARCP circuit can be used in a wireless power transfer system to achieve ZVS. Detailed analysis of ARCP circuit operation is presented to determine the requirements for achieving ZVS in the main switches of a wireless electric vehicle charging system. Based on this analysis, a design algorithm is developed to optimize the design of the ZVS assisting circuit components. The designed ARCP achieves soft switching of the MOSFETs in the primary inverter of an 85 kHz, 10 kW series-series compensated, stationary wireless power transfer system.

Saha, Tarak↗

Optimized System for On-Route Fast Charging of Battery-Electric Shuttle Buses

Electrifying cars, buses, and trucks is an attractive means of reducing energy use and emissions because it involves more efficient drivetrain components and minimal restructuring of the transportation network. Transit buses, driving fixed routes, help minimize driver range anxiety by properly sizing energy storage systems. A major challenge to fully electrifying transit buses is providing the amount of energy they consume in a day of driving. To enable a full day of operation without charging, batteries need to be large, which could be expensive and heavy. This work utilizes real-world transit bus data used in a battery-electric drivetrain model to co-optimize charger locations, charger power levels, and vehicle battery sizes.

ADVANCED PROPULSION SYSTEMS↗

Adapting Optimal Velocity Tracking Control to Account for WEC Constraints and Power-Take-Off Efficiencies: Preprint

Wave energy converters (WECs) come in many different forms, from point absorbers, oscillating water columns, to bulge wave devices. This paper focuses on the control of point absorber WECs, which typically have a narrow-banded frequency response and, therefore, control is well placed to improve the energy capture of such WECs. The acausal nature of the control problem means that theoretically optimal control is almost impossible to achieve inpractice; however optimal velocity tracking (OVT) offers a simple and robust approximation to optimal control that can achieve better power capture than passive linear damping methods, albeit with necessarily higher force demands. OVT is a form of impedance matching and the magnitude of the power-take off (PTO) force demand is often not linearly proportional to the WEC velocity, which can lead to PTO force and speed combinations far from the optimalPTO efficiency. The highly non-linear PTO force and speed to efficiency mapping can, without remedial measures, severely diminish the effectiveness of OVT techniques. In this paper, limits to the movement and force of the PTO are demonstrated, allowing OVT to be more easily applied in practice. The effect of PTO efficiency is explored, and a potential solution to the problem of adapting control to account for efficiency is presented. Both aspects of the work presented highlight the requirement for co-design of the WEC, PTO, and controller.

conversion efficiency↗

Insights into Methodologies and Stochastic Optimization of Thermal Energy Storage-Coupled Advanced Reactor Systems: A Comparison of Methods for Accessing Long-Term Sub-System Sizing Adequacy

This paper investigates the potential of coupling Thermal Energy Storage (TES) with Advanced Reactors (ARs) to address uncertainties posed by climate change in deep decarbonized power systems. The TES Use-case Team at Idaho National Laboratory (INL) has examined the potential of storing thermal energy from ARs during low demand periods and optimizing discharge during peak-priced hours, in both steady-state and transient conditions. Building on this groundwork, this study bridges the gaps in optimal sizing of the sub-system of TES-coupled AR systems using Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON), INL?s framework for grid optimization. By applying this framework, we present statistically-robust optimal charge, discharge including balance of plant (BOP), and storage sizing for the High-Temperature Gas-Cooled Reactor (HTGR) with 203 MWth output. To this end, we generated synthetic price samples for 30 years using 2018 ? 2021 real-time market data from ERCOT, PJM and MISO. Our results reveals that the TES-coupled HTGR system is highly effective in maximizing revenue from electricity sales. We observed a substantial increase of 40 % in ERCOT and a noteworthy 15 % increase in PJM and MISO when compared to the conventional BOP without TES. This improvement is achieved through regionally-tailored sub-system sizing, which ranges from 398 to 416 MWth for the discharge system and 610 to 1029 MWth for the TES. We find that the average electricity price directly impacts the overall economics, while price volatility influences storage size. Additional sensitivity analyses were performed to access the impact of key assumptions on system economics and sizing, differentiating the optimization window (i.e., 24 ? 219 hours of chronological observations) and by imposing storage continuity condition in tracking TES cycles. We observed that at the 120-hour of the optimization window, a reasonable balance between computation time and accuracy was achieved. Our analysis also highlights the significance of conducting multi-day cycle analysis (> 120-hour) for TES to capture interaction between electricity prices and storage dynamics, providing a comprehensive understanding of TES behavior that AR developers should integrate into their plant designs.

25 ENERGY STORAGE↗

Environmental and economic optima of solar home systems design: A combined LCA and LCC approach

Here, we compare the economic and environmental optimal design of Solar Home Systems (SHSs) and explore the role of economic incentives (such as tariffs and technology costs) in approximating the two optima. To achieve that, we present a methodology for the environmental and economic evaluation of grid-connected SHSs: user-scale electric systems involving a photovoltaic (PV) power system and a battery energy storage system. The proposed methodology is based on a mixed integer linear programming (MILP) optimization, life cycle assessment and life cycle costing. This methodological framework is applied to a case study involving a typical SHS installation in Italy. The results of the environmental optimal design brought to the evaluation of a 3.25 kW PV assisted by 8.66 kWh of nickel cobalt manganese batteries, whereas the costs of the SHS are minimized by a small PV system (less than 1 kW). Results underline that the environmental optimal configurations rely on battery technologies, which entails a significant cost compared to the grid connection. In contrast, the economic optimal design solutions is less impactful than the grid mix both from an environmental and economic points of view. Thanks to a reduction of batteries and PV costs, the environmental impact of the economic optimal design is expected to decrease in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVALUATING FACILITY ENERGY EFFICIENCY AND RESILIENCE OPPORTUNITIES WITH FEDS AND MCOR

Energy resilience has become increasingly important for critical building infrastructure, in response to concerns over potential disruptions to the electrical grid from threats both natural and man-made. Energy efficiency can provide a valuable resource for reducing critical loads and therefore lowering the cost of supplying alternative power. This paper highlights two tools that are well-suited for analyzing building energy efficiency and resilience opportunities and presents a case study for their combined application. The Facility Energy Decision System (FEDS) and Microgrid Component Optimization for Resilience (MCOR) tools can be used together to simulate building systems, identify energy efficiency measures, and evaluate resilience options for powering a site during an outage.

FEDS, MCOR, Energy Efficiency, Resilience, Simulat↗

Oxy-Combustion System Process Optimization

The overall objective of this work is to develop a new chemical absorbent-based, high pressure, CO 2 purification system to remove the residual oxygen that currently contaminates the recovered CO 2 , and to optimize the Pressurized Oxy-Combustion (POxC) process to minimize the Cost of Electricity (COE) generated in this advanced combustion process. TDA developed and validated the performance of the oxygen removal system for CO 2 purification. In collaboration with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI), we optimized the POxC process, including thermal management, heat integration, and power cycle optimization using process design and modeling supported with Aspen Plus® process simulations. The techno-economic analysis results indicate that the pressurized oxycombustion coal power plant with Ion-transport membrane (ITM) air separation unit (ASU) (Case 2 – 30.55%) does not show an advantage over a cryogenic ASU (Case 1 – 31.24%) while TDA’s sorption-based ASU (Case 4 - 32.61%) shows a significant advantage over the cryogenic ASU (Case 1 – 331.24%). The specific plant costs show a wide range with a low of $2544/kW for Case 11C (TDA ASU, co-sequestering the SO x , and ultra-supercritical steam cycle) to a high of $2975/kW for Case 12A (cryogenic ASU and sCO 2 cycle). In general, the ITM ASU based cases have lower specific plant costs than the corresponding cryogenic ASU based cases while the TDA ASU based cases show the lowest specific plant costs. The main reason for lowering these costs is the higher overall plant thermal efficiency which decreases the plant cost on a $ per kW basis. Next comparing the cases with different power cycle working fluid conditions in terms of temperature and pressure while all utilizing steam, similar trends as the plant costs may be observed. However, with the supercritical CO 2 (sCO 2 ) cycle, the increase in thermal efficiency of the sCO 2 cycle was not able to offset its increase in plant cost making the plant costs higher than those of the corresponding steam cycle cases. The Cost of Electricity (COE) again shows similar trends as the specific plant costs. The COE for Case 11C at $110.1/MWh is also the lowest, but among all cases that do not co-sequester the SO x , Case 12C (TDA ASU and sCO 2 cycle) has the lowest COE at $\$$117.5/MWh while the highest is for Case 8A (cryogenic ASU and supercritical steam cycle) at $130.4/MWh.

20 FOSSIL-FUELED POWER PLANTS↗