Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Analysis of MIR-18 results for physical and biological dosimetry: radiation shielding effectiveness in LEO

We compare models of radiation transport and biological response to physical and biological dosimetry results from astronauts on the Mir space station. Transport models are shown to be in good agreement with physical measurements and indicate that the ratio of equivalent dose from the Galactic Cosmic Rays (GCR) to protons is about 3/2:1 and that this ratio will increase for exposures to internal organs. Two biological response models are used to compare to the Mir biodosimetry for chromosome aberration in lymphocyte cells; a track-structure model and the linear-quadratic model with linear energy transfer (LET) dependent weighting coefficients. These models are fit to in vitro data for aberration formation in human lymphocytes by photons and charged particles. Both models are found to be in reasonable agreement with data for aberrations in lymphocytes of Mir crew members: however there are differences between the use of LET dependent weighting factors and track structure models for assigning radiation quality factors. The major difference in the models is the increased effectiveness predicted by the track model for low charge and energy ions with LET near 10 keV/micrometers. The results of our calculations indicate that aluminum shielding, although providing important mitigation of the effects of trapped radiation, provides no protective effect from the galactic cosmic rays (GCR) in low-earth orbit (LEO) using either equivalent dose or the number of chromosome aberrations as a measure until about 100 g/cm 2 of material is used.

Flight Experiment↗

Flight Data Update on Long-Term Compound Stability in Dual Sorbent Tubes

Dual Sorbent Tubes (DSTs) are currently the primary method for collecting volatile organic compounds in the cabin air of the International Space Station (ISS). Data from groundbased analysis of these archival air samplers provide a major component of the assessment of ISS air quality by the NASA toxicologist. At the 2005 ICES conference data from the positive control DSTs, returned on Soyuz 7S and 8S, were presented. Positive control tubes are dosed, preflight, with known concentrations of representative contaminant compounds and they are launched to ISS in the DST kit as trip controls. Upon return of the DST kit to the ground, results from analysis of the trip (positive) and laboratory control tubes are used to determine the recoveries: concentration of dosed compounds retained in the tube. Results from positive controls, returned on 7S and 8S showed substantial losses of some compounds dosed into the tubes 156 to 240 days prior to the analysis. Low recoveries are expected for spacecraft air contaminants with similar properties to the poorly recovered dosed compounds. It was shown that compound losses in the control tubes were consistent, which led to the generation of acceptable correction factors for spacecraft air contaminants. Correction factors decrease the accuracy of derived compound concentrations and substantial error could arise under some conditions. An investigation into the mechanism for compound loss is necessary before design modifications can be implemented to improve the DST performance. This paper will update results from the DSTs returned on Soyuz 9S and 10S missions during the latter part of 2005. The data acquired from these returned DSTs will be compared to the 7S and 8S data presented last year. Discussion will focus on the reliability of correction factors and identify any trends in the data. This paper will describe the experimental design and plans to identify the compound loss mechanism.

James, John T.↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reassessment of Dose Contributions from the M-Area Glass Special Waste Form Buried in the E-Area Low-Level Waste Facility

During a recent revision to the groundwater (GW) and inadvertent human intruder (IHI) screening analysis report (Aleman and Hamm, 2023), weaknesses within the screening logic were observed resulting in U-235 being brought back into the list of radionuclides requiring inventory limits within the M-Area Glass SWF. In addition, while reviewing the earlier vadose zone (VZ) transport analysis efforts, an input deck error was observed in the U-234G VZ transport simulation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

Measurements of the radiation dose to LDEF by means of passive dosimetry

A very simple experiment was fielded on LDEF to measure the energetic radiation dose by means of passive dosimetry. It consisted of two identical packets of 16 LiF thermoluminescent dosimeters (TLD) arranged in planar arrays. One array was placed on the leading edge of the spacecraft, the other on the trailing edge. These arrays were installed in opaque packets of 1 mil Al foil and Kapton tape mounted behind an Al plate of 30 mils thickness. The nominal energy thresholds were 14 MeV for protons and 650 keV for electrons. In addition to the flight arrays, two control arrays were prepared which were kept with the flight arrays as long as possible during experimental integration and then stored in the lab. The flight and control arrays were read out alternating in groups of four; it was found that the control dose was negligible. The flight and control detectors were exposed to a 55 MeV proton beam in order to provide a recalibration of the detectors. It was found that the post-flight and pre-flight calibrations were in good agreement. A comparison of results with the prediction shows that the measured dose was a factor of 4 to 5 low. It is possible that there was in-flight annealing of the TLDs as a result of the long mission and perhaps temperature excursions of the sensors. The East-West effect was larger than expected. The ratio of 1.65 is approximately what was expected for the protons alone. Electrons should reduce the dose ratio since electrons add equally to the leading and trailing edge dose. A possible explanation is that the electron dose was negligible compared to the proton dose.

Blake, J. B.↗

Irradiation damage concurrent challenges with RAFM and ODS steels for fusion reactor first-wall/blanket: a review

Reduced activation ferritic martensitic (RAFM) and oxide dispersion strengthened (ODS) steels are the most promising candidates for fusion first-wall/blanket (FW/B) structures. The performance of these steels will deteriorate during service due to neutron damage and transmutation-induced gases, such as helium/hydrogen, at elevated operating temperatures. Here, after highlighting the operating conditions of fusion reactor concepts and a brief overview, the main irradiation-induced degradation challenges associated with RAFM/ODS steels are discussed. Their long-term degradation scenarios such as (a) low-temperature hardening embrittlement (LTHE)—including dose-temperature dependent yield stress, tensile elongations, necking ductility, test temperature effect on hardening, Charpy impact ductile-to-brittle transition temperature and fracture toughness, (b) intermediate temperature cavity swelling, (c) the effect of helium on LTHE and cavity swelling, (d) irradiation creep and (e) tritium management issues are reviewed. The potential causes of LTHE are discussed, which highlights the need for advanced characterisation techniques. The mechanical properties, including the tensile/Charpy impact of RAFM and ODS steels, are compared to show that the current generation of ODS steels also suffers from LTHE, and shows irradiation hardening up to high temperatures of ~400 °C–500 °C. To minimise this, future ODS steel development for FW/B-specific application should target materials with a lower Cr concentration (to minimise α'), and minimise other elements that could form embrittling phases under irradiation. RAFM steel-designing activities targeting improvements in creep and LTHE are reviewed. The need to better understand the synergistic effects of helium on the thermo-mechanical properties in the entire temperature range of FW/B is highlighted. Because fusion operating conditions will be complex, including stresses due to the magnetic field, primary loads like coolant pressure, secondary loads from thermal gradients, and due to spatial variation in damage levels and gas production rates, an experimentally validated multiscale modelling approach is suggested as a pathway to future reactor component designing such as for the fusion neutron science facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the Appropriate Emergency Planning Attributes for Microreactors

Micro-reactor designs incorporate design features that provide very low reactor decay heat power at 24 hours after shutdown that is manageable in comparison with larger reactors. This attribute translates into a low probability of core damage negligible offsite dose. This paper provides the conceptual framework for appropriately structuring emergency planning requirements for micro-reactors while ensuring the U.S. Nuclear Regulatory Commission’s (NRC) commitment to safety is met. Due to the diversity in reactor designs comprising the micro-reactor community, this paper identifies the necessary concepts that should be considered to ensure emergency plans for micro-reactors are appropriate for the risk. This paper does not mandate specific design features for micro-reactors but provides reactor designers a conceptual framework for a scalable, graded approach to Emergency Planning Standards that should be considered in their individual designs in order to support simplified emergency plans. Given that accident source terms associated with micro-reactors are essentially negligible when compared with those for large light water reactors, revisions to emergency planning standards are justified. A graded approach to implementing emergency planning guidance can be used to appropriately structure micro-reactor emergency plans and reduce the size of the emergency planning zone and plume exposure pathway. Appropriately structuring emergency planning requirements will better optimize licensee and offsite agencies emergency planning resources and reduce the resources associated with emergency planning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of Hypothetical Processes for the Production of 131 I and 99 Mo from Activation Targets

For over six decades, medical isotope production has been a high-priority focus of many research reactors across the globe. The majority of these isotopes were produced using highly-enriched uranium (HEU) or low enriched uranium (LEU) – delivering millions of doses of diagnostic and therapeutic isotopes. As a consequence of this production, however, six decades of isotope production has resulted in massive quantities of spent uranium material worldwide with no known disposition pathway creating growing proliferation concerns. Supported by the National Nuclear Security Administration’s (NNSA) Material Management and Minimization (M3) program, there has been increased focus in the production of high-priority isotopes without special nuclear materials or without uranium altogether. Isotope production via activation can potentially fulfill regional isotope demands – particularly in under-developed regions without access to isotope supply chains. The benefits of this approach would be a reduction in uranium proliferation risks, less special nuclear material wastes, and reduced risk of supply disruption in the likely event that major isotope producers will again go off-line as has happened in recent years due to a number of factors.

07 ISOTOPE AND RADIATION SOURCES↗

On the validity of equivalent electron fluence for GaAs solar cells

A simple model for particulate radiation damage in shallow-junction heteroface GaAs solar cells is used to evaluate the equivalent electron fluence concept especially in the sense of additivity of electron and proton exposure. It is found that spatial dependent factors for low-energy proton exposure results in a dose dependent equivalent fluence ratio so that additivity within the equivalent fluence concept is generally not possible.

Wilson, J. W.↗

Trapped Radiation Model Uncertainties: Model-Data and Model-Model Comparisons

The standard AP8 and AE8 models for predicting trapped proton and electron environments have been compared with several sets of flight data to evaluate model uncertainties. Model comparisons are made with flux and dose measurements made on various U.S. low-Earth orbit satellites (APEX, CRRES, DMSP. LDEF, NOAA) and Space Shuttle flights, on Russian satellites (Photon-8, Cosmos-1887, Cosmos-2044), and on the Russian Mir space station. This report gives the details of the model-data comparisons -- summary results in terms of empirical model uncertainty factors that can be applied for spacecraft design applications are given in a companion report. The results of model-model comparisons are also presented from standard AP8 and AE8 model predictions compared with the European Space Agency versions of AP8 and AE8 and with Russian trapped radiation models.

Armstrong, T. W.↗

Trapped Radiation Model Uncertainties: Model-Data and Model-Model Comparisons

The standard AP8 and AE8 models for predicting trapped proton and electron environments have been compared with several sets of flight data to evaluate model uncertainties. Model comparisons are made with flux and dose measurements made on various U.S. low-Earth orbit satellites (APEX, CRRES, DMSP, LDEF, NOAA) and Space Shuttle flights, on Russian satellites (Photon-8, Cosmos-1887, Cosmos-2044), and on the Russian Mir Space Station. This report gives the details of the model-data comparisons-summary results in terms of empirical model uncertainty factors that can be applied for spacecraft design applications are given in a combination report. The results of model-model comparisons are also presented from standard AP8 and AE8 model predictions compared with the European Space Agency versions of AP8 and AE8 and with Russian-trapped radiation models.

Armstrong, T. W.↗

Optically stimulated luminescence and thermoluminescence efficiencies for high-energy heavy charged particle irradiation in Al2O3:C

The thermally and optically stimulated luminescence (TL and OSL) response to high energy heavy-charged particles (HCPs) was investigated for two types of Al2O3:C luminescence dosimeters. The OSL signal was measured in both continuous-wave (CW) and pulsed mode. The efficiencies of the HCPs at producing TL or OSL, relative to gamma radiation, were obtained using four different HCPs beams (150 MeV/u 4He, 400 MeV/u 12C, 490 MeV/u 28Si, and 500 MeV/u 56Fe). The efficiencies were determined as a function of the HCP linear energy transfer (LET). It was observed that the efficiency depends on the type of detector, measurement technique, and the choice of signal. Additionally, it is shown that the shape of the CW-OSL decay curve from Al2O3:C depends on the type of radiation, and, in principle, this can be used to extract information concerning the LET of an unknown radiation field. The response of the dosimeters to low-LET radiation was also investigated for doses in the range from about 1-1000 Gy. These data were used to explain the different efficiency values obtained for the different materials and techniques, as well as the LET dependence of the CW-OSL decay curve shape. c2003 Elsevier Ltd. All rights reserved.

Thermoluminescent Dosimetry/instrumentation/method↗

Antimicrobial Materials for Advanced Microbial Control in Spacecraft Water Systems

Microbial detection, identification, and control are essential for the maintenance and preservation of spacecraft water systems. Requirements set by NASA put limitations on the energy, mass, materials, noise, cost, and crew time that can be devoted to microbial control. Efforts are being made to attain real-time detection and identification of microbial contamination in microgravity environments. Research for evaluating technologies for capability enhancement on-orbit is currently focused on the use of adenosine triphosphate (ATP) analysis for detection purposes and polymerase chain reaction (peR) for microbial identification. Additional research is being conducted on how to control for microbial contamination on a continual basis. Existing microbial control methods in spacecraft utilize iodine or ionic silver biocides, physical disinfection, and point-of-use sterilization filters. Although these methods are effective, they require re-dosing due to loss of efficacy, have low human toxicity thresholds, produce poor taste, and consume valuable mass and crew time. Thus, alternative methods for microbial control are needed. This project also explores ultraviolet light-emitting diodes (UV-LEDs), surface passivation methods for maintaining residual biocide levels, and several antimicrobial materials aimed at improving current microbial control techniques, as well as addressing other materials presently under analysis and future directions to be pursued.

Birmele, Michele↗

NAIRAS Model Updates and Improvements to the Prediction of the Ionizing Radiation Environment from the Earth's Surface to Geospace

- NAIRAS Model Description - Nowcast of Aerospace Ionizing RAdiation System (NAIRAS) Model - Running in real-time on LaRC computer cluster since 2011, results hosted on Space Environment Technologies server/website - Running in real-time at CCMC since 2020 - Key Model Features - Global ionizing radiation environment model - Physics-based HZETRN (High Charge (Z) and Energy TRaNsport) code - Real-time inclusion of solar energetic particle (SEP) radiation - Real-time solar-magnetospheric effects on radiation (cutoff model by Kress et al. [2004, 2010]) - New/Current Model Development - Improved SEP dose nowcast and forecast - Extend to low-Earth orbit (LEO) environment - Single-Event Effects (SEE) radiation risk assessment quantities - Run-on-Request (RoR) @ CCMC

Christopher J. Mertens↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗