NASA NTRS · 20000032457
Trapped Radiation Model Uncertainties: Model-Data and Model-Model Comparisons
Abstract
The standard AP8 and AE8 models for predicting trapped proton and electron environments have been compared with several sets of flight data to evaluate model uncertainties. Model comparisons are made with flux and dose measurements made on various U.S. low-Earth orbit satellites (APEX, CRRES, DMSP, LDEF, NOAA) and Space Shuttle flights, on Russian satellites (Photon-8, Cosmos-1887, Cosmos-2044), and on the Russian Mir Space Station. This report gives the details of the model-data comparisons-summary results in terms of empirical model uncertainty factors that can be applied for spacecraft design applications are given in a combination report. The results of model-model comparisons are also presented from standard AP8 and AE8 model predictions compared with the European Space Agency versions of AP8 and AE8 and with Russian-trapped radiation models.
Keep this discovery
Explore connections, maps & timelines
Armstrong, T. W., Colborn, B. L.. 2000-03-01. Trapped Radiation Model Uncertainties: Model-Data and Model-Model Comparisons. https://ntrs.nasa.gov/citations/20000032457
Cite the original work for its findings. Save a collection to share your selection of sources.