Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Visual motion integration for perception and pursuit

To examine the relationship between visual motion processing for perception and pursuit, we measured the pursuit eye-movement and perceptual responses to the same complex-motion stimuli. We show that humans can both perceive and pursue the motion of line-figure objects, even when partial occlusion makes the resulting image motion vastly different from the underlying object motion. Our results show that both perception and pursuit can perform largely accurate motion integration, i.e. the selective combination of local motion signals across the visual field to derive global object motion. Furthermore, because we manipulated perceived motion while keeping image motion identical, the observed parallel changes in perception and pursuit show that the motion signals driving steady-state pursuit and perception are linked. These findings disprove current pursuit models whose control strategy is to minimize retinal image motion, and suggest a new framework for the interplay between visual cortex and cerebellum in visuomotor control.

NASA Center ARC↗

Earth System Digital Twins (ESDT) Technology for NASA Earth Science

For NASA's Advanced Information Systems Technology (AIST) Program, an Earth System Digital Twin (ESDT) is defined as an interactive and integrated multidomain, multiscale, digital replica of the state and temporal evolution of Earth systems. It dynamically integrates: relevant Earth system models and simulations; other relevant models (e.g., related to the world's infrastructure); continuous and timely (including near real time and direct readout) observations (e.g., space, air, ground, over/underwater, Internet of Things (IoT), socioeconomic); long-time records; as well as analytics and artificial intelligence tools. Effective ESDTs enable users to run hypothetical scenarios to improve the understanding, prediction of and mitigation/response to Earth system processes, natural phenomena and human activities as well as their many interactions. An ESDT is a type of integrated information system that, for example, enables continuous assessment of impact from naturally occurring and/or human activities on physical and natural environments. AIST ESDT strategic goals are to: 1. Develop information system frameworks to provide continuous and accurate representations of systems as they change over time; 2. Mirror various Earth Science systems and utilize the combination of Data Analytics, Artificial Intelligence, Digital Thread, and state-of-the-art models to help predict the Earth’s response to various phenomena; 3. Provide the tools to conduct "what if" investigations that can result in actionable predictions. The AIST ESDT thrust is developing capabilities toward the development of future digital twins of the Earth or of subcomponents of the Earth. This will enable the development of an overarching framework that will integrate New Observing Strategies (NOS) to enable new observation measurements, i.e., multi-source, coordinated, dynamic and responsive to needs and requests defined by Analytic Collaborative Frameworks (ACF) that enable agile science investigations fusing and analyzing very large amounts of diverse data. NOS and ACF capabilities along with open access to various science, infrastructure and human data, interconnected modeling, data assimilation, simulations, surrogate modeling, high-performance computing and advanced visualization, will define a powerful framework that could be utilized for local, regional or global and/or thematic digital twins. This presentation will describe a general overview of the AIST ESDT vision including prior work done in the areas of NOS and ACF as well as current and upcoming ESDT projects.

Jacqueline Le Moigne↗

Standard measures in Analogs of Spaceflight

Standard measures are defined as research measures (physiological, performance, or otherwise) that quantify the subject’s health and performance before, during, and after a spaceflight or a spaceflight analog mission. The Standard Measures Cross-Cutting Project (SMCCP) collects and analyzes standard measures that support assessment and quantification of health risks and efficacy of countermeasures and technologies required to prevent or mitigate adverse outcomes from exposure to the spaceflight environment. SMCCP uses the following spaceflight analogs: - Human Exploration Research Analog (HERA) in Houston, TX: 4-person isolation/confinement; nominal mission duration of 45 days; run by the Human Research Program (HRP). SMCCP uses weekly questionnaires to gather data on the crewmembers’ emotional and mental state and collects blood samples biweekly to measure crewmembers’ serum cortisol levels at the start, middle, and end of the mission. - Institute for Biomedical Problems (IBMP) Ground-Based Experimental Complex, called NEK, in Moscow, Russia: 6-person isolation/confinement; duration of 8 months; run by IBMP. Standard measures data collected during NEK are the same as for HERA above. - :envihab in Cologne, Germany: 12-person bed rest facility; closed environment; 30 to 60-day campaigns; run by the German Aerospace Center (DLR). For bedrest studies, SMCCP uses the international standard measures as documented in the International Academy of Astronautics publication titled Guidelines for Standardization of Bed Rest Studies in the Spaceflight Context (June 2014). These international standard measures evaluate potential changes in bone, muscle, cardiovascular, and visual systems, as well as changes in psychology and nutrition. The international standard measures complement those collected during studies by individual investigators and allow comparison of responses across different bed rest and countermeasures durations. In this presentation, we will review available SMCCP data collected during the recent isolation studies in HERA (C6) and NEK (SIRIUS-21), and during the SANS (SM1, SM2) bed rest studies in :envihab. These standard measures datasets are made available to concurrent investigators in the given mission or campaign via data sharing agreements and/or data sharing plans and to other investigators that have been granted retrospective access to the data (researchers with IRB approved protocols, risk custodians) to advance understanding of physiological and behavioral risks associated with these spaceflight analogs.

Standard Measures↗

Intrusion Monitoring in Process Control Systems

To protect process control networks from cyber intrusions, preventive security measures such as perimeter defenses (for example, network firewalls and demilitarized zones) and secure versions of process control network protocols have been increasingly adopted or proposed. Although system hardening and fixing known vulnerabilities of existing systems are crucial to secure process control systems, intrusion monitoring is essential to ensure that the preventive measures are not compromised or bypassed. Our approach involves a multilayer security architecture for monitoring process control systems to achieve accurate and effective situational awareness. Also, we leverage some of the characteristics of process control systems such as the regularity of network traffic patterns to perform intrusion detection, with the potential to detect unknown attacks. To facilitate human analysts to gain a better understanding of anomalous network traffic patterns, we present a visualization tool that supports multiple usercustomizable views and animation for analyzing network packet traces.

97 MATHEMATICS AND COMPUTING↗

Benefits of Advanced Control Room Technologies: Phase One Upgrades to the HSSL, Research Plan, and Performance Measures

Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control room. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report describes the initial upgrades to the HSSL and outlines the methodology for a pilot test of the HSSL configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15%,respectively.Mean M-ADC for ADC measured from 4D-DWI and M-ADC measured from FB-DWI were (2.29±0.04)*0.001*mm2/s and (3.80±0.01)*0.001*mm2/s,respectively.ADC value ground-truth is 2.24*0.001*mm2/s from the input of the simulation. Conclusion: A respiratory correlated 4D-DWI technique has been initially evaluated in phantoms and a human subject.Comparing to free breathing DWI,4D-DWI can lead to more accurate measurement of ADC.

60 APPLIED LIFE SCIENCES↗

Assessment of BoneTtissue Mineralization by Conventional X-ray Microcomputed tomography: Comparison with Synchrotron Radiation Microcomputed Tomography and Ash Measurements

Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.

43 PARTICLE ACCELERATORS↗

Evaluating Safety with Automated Vehicles at Signalized Intersections: Application of Adaptive Cruise Control in Mixed Traffic

Automated Vehicles (AV) can potentially improve the performance of transportation system by reducing human errors and enhancing mobility and safety. In lower levels of automation, humans are still controlling the vehicle and receiving some advisory information regarding their surrounding environment. This paper investigates the safety impact of low and high levels of AVs, and their interaction with conventional human-driven vehicles at intersections. In order to enhance our understanding of the future interactions between conventional vehicles with AVs, we developed a framework to simulate the mixed traffic environment. Different market penetration scenarios are simulated using VENTOS (VEhicular NeTwork Open Simulator) software. A modified Wiedemann car-following model was calibrated to represent the behavior of human drivers of both conventional and low-level AVs, while an Adaptive Cruise Control model was used to represent high-level AVs. Notably, this study investigates purely the automation improvement in the system. We modified the acceleration and deceleration regimes of the Wiedemann model and tuned it by harnessing real-world connected vehicle data. Next, the simulation was calibrated utilizing two measures of driving volatility to ensure it closely represents the volatility measures of the real-world data. To evaluate the safety performance of a representative intersection under different scenarios, the number of longitudinal conflicts and driving volatility are used as surrogate safety indicators. The results reveal that increase in market penetration rate of LAVs and HAVs substantially improves intersection safety performance by reducing the number of conflicts and driving volatility.

Arvin, Ramin↗

Radiation-Induced Micro-RNA Expression Changes in Peripheral Blood Cells of Radiotherapy Patients

Purpose: MicroRNAs (miRNAs), a class of noncoding small RNAs that regulate gene expression, are involved in numerous physiologic processes in normal and malignant cells. Our in vivo study measured miRNA and gene expression changes in human blood cells in response to ionizing radiation, to develop miRNA signatures that can be used as biomarkers for radiation exposure. Methods and Materials: Blood from 8 radiotherapy patients in complete remission 1 or 2 was collected immediately before and 4 hours after total body irradiation with 1.25 Gy x-rays. Both miRNA and gene expression changes were measured by means of quantitative polymerase chain reaction and microarray hybridization, respectively. Hierarchic clustering, multidimensional scaling, class prediction, and gene ontology analysis were performed to investigate the potential of miRNAs to serve as radiation biomarkers and to elucidate their likely physiologic roles in the radiation response. Results: The expression levels of 45 miRNAs were statistically significantly upregulated 4 hours after irradiation with 1.25 Gy x-rays, 27 of them in every patient. Nonirradiated and irradiated samples form separate clusters in hierarchic clustering and multidimensional scaling. Out of 223 differentially expressed genes, 37 were both downregulated and predicted targets of the upregulated miRNAs. Paired and unpaired miRNA-based classifiers that we developed can predict the class membership of a sample with unknown irradiation status, with accuracies of 100% when all 45 upregulated miRNAs are included. Both miRNA control of and gene involvement in biologic processes such as hemopoiesis and the immune response are increased after irradiation, whereas metabolic processes are underrepresented among all differentially expressed genes and the genes controlled by miRNAs. Conclusions: Exposure to ionizing radiation leads to the upregulation of the expression of a considerable proportion of the human miRNAome of peripheral blood cells. These miRNA expression signatures can be used as biomarkers of radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-to-End Assessment of Artemis-1 Development Flight Instrumentation

As the space industry continues to strive for more efficient launch vehicles they must rely on increasingly accurate predictive models. Verification of models typically requires physical testing. Flight data measurements offer the most real and therefore the most accurate data for model correlation. As NASA prepares for the inaugural launch of their new Space Launch System (SLS), Artemis-1, they must rely heavily on predictive system models to ensure flight safety. Artemis-1 will be an unmanned scientific mission with the intent of blazing a trail for future manned missions. NASA has implemented a system of Development Flight Instrumentation (DFI) in the hopes of recovering useful flight data during liftoff and ascent to aid in correlating their predictive models to ensure human safety in future missions. An end-to-end assessment of the DFI system was performed to verify data acquired during Artemis-1 would be adequate for the targeted flight test objectives (FTOs). This was accomplished using a computational simulation of all sensors and Data Acquisition (DAQ) parameters to investigate any potential problem areas in the current architecture. Input nominal signals were approximated and injected into the system model. Synthesized acquired signals were recovered to verify FTO success.

Flight measurement↗

STS-47 Mission Highlights Resource Tape

The mission of the STS-47 flight is highlighted in this video. The flight crew consisted of: Cmdr. 'Hoot' Gibson, Pilot Kurt Brown, Payload Cmdr. Jan Davis, Payload Specialist. M. Mohri (Japanese Astronaut), and Mission Specialists Jay Apt and May Jemison. The primary goal of this mission was the set-up and carrying out of experiments in the accompanying Japanese Spacelab (SL-J) in cooperation with the Japanese Space Program. Dr. Mohri is the first professional Japanese astronaut to fly in space. Vice President Dan Quayle and his wife are shown addressing the astronauts of the Space Shuttle Endeavour with a small pre-launch speech. On this flight many different physical, physiological, and biological spaceborne experiments were performed. These experiments included: a gas evaporation in low gravity environment experiment; a brainwave signals from carp experiment; several human eye movement and visual physiological tests; various physiological tests on a variety of insects and frogs; a embryology experiments on tadpoles; several experiments concerned with fluid dynamics; an imaging furnace test with heated glass containing gold particles (flow measurement); a Solid Surface Combustion Experiment; and a protein crystal growth experiment. Launch, in-orbit, and landing footage is shown, along with a variety of crew activities. One feature that astronauts were able to videotape was the actual in-orbit movement of the side wing flaps of the Space Shuttle.

Source record↗

An infrared system for monitoring Drosophila motility during microgravity

Presently, the precise mechanisms of the aging process are unknown. Examination and comprehension of the aging process in other species could lead to significant advances in the understanding of human aging. Drosophila melanogaster (fruit fly), commonly used for aging studies, is a widely studied organism in terms of behavior, development, and genetics. Previous microgravity experiments have shown a significant decrease in the life span of young male Drosophila after microgravity exposure. This decrease in lifespan may be related to locomotor activity, a convenient measure of overall physiological performance. This study describes the design and performance of a Drosophila Infrared Motility Monitoring System (DIMMS). The DIMMS uses a unique design of two infrared (IR) beams per fly to measure the locomotor activity of 240 flies. Locomotor activity is measured in terms of number of IR crossings per unit time, instantaneous velocity, and continuous velocity. Ground-based results using the DIMMS equipment agree well with previous values for Drosophila locomotor velocity. DIMMS is an improvement over equipment previously used due to its ability to continuously monitor locomotor activity throughout short-duration microgravity exposure. DIMMS is also lightweight, compact, and power efficient. DIMMS has been flight tested onboard NASA's KC-135 reduced gravity research aircraft and a Nike-Orion sounding rocket.

unmanned↗

Options for low–global-warming-potential and natural refrigerants- Performance for heat pump application and analysis of systemic irreversibilities

There is growing interest in substituting existing refrigerants with low global warming potential (GWP) refrigerants, including naturally occurring fluids, to reduce the impact of human activities on climate change. In this study we have evaluated prospective low-GWP refrigerants in four distinct heat pump cycles using the First and Second laws of thermodynamics. The essence of the study is to establish the performance of the low-GWP refrigerants when deployed in a heat pump system. Exergy analysis provides a true measure of lost work, or systemic inefficiencies, vividly quantifying areas of improvement and identifying the preferred cycle for a refrigerant. The combined knowledge of the properties of the phase boundary on either side of the critical point (DOI:10.1.18462/iir.icr.2019.442), and exergy analysis of prospective cycles is necessary for a better perspective on discriminating among refrigerants as hydrochlorofluorocarbons are phased out and replacement refrigerants must be found.

Nawaz, Kashif↗

Shifting the Paradigm for Long Term Monitoring at Legacy Sites to Improve Performance while Reducing Cost

A major issue facing many government and private industry sites that were previously contaminated with radioactive and chemical wastes is that often the sites cannot be cleaned up enough to permit unrestricted human access. These sites will require long-term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality in a cost effective manner. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site (SRS), the larger DOE complex, and many large federal and private sites. Currently, most monitoring strategies are focused on laboratory measurements of contaminants measured in groundwater samples collected from wells. This approach is expensive, and provides limited and lagging information about the effectiveness of cleanup activities and the behavior of the residual contamination. Over the last twenty years, DOE and other federal agencies have made significant investments in the development of various types of sensors and strategies that would allow for remote analysis of contaminants in groundwater, but these approaches do not promise significant reductions in risk or cost. Scientists at SRS have developed a new paradigm to simultaneously improve the performance of long term monitoring systems while lowering the overall cost of monitoring. This alternative approach incorporates traditional point measurements of contaminant concentration with measurements of controlling variables including boundary conditions, master variables, and traditional plume/contaminant variables. Boundary conditions are the overall driving forces that control plume movement and therefore provide leading indication to changes in plume stability. These variables include metrics associated with meteorology, hydrology, hydrogeology, and land use. Master variables are the key variables that control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. A robust suite of relatively inexpensive tools is commercially available to measure these variables. Traditional plume/contaminant variables are various measures of contaminant concentration including traditional analysis of chemicals in groundwater samples. An innovative long term monitoring strategy has been developed for acidic or caustic groundwater plumes contaminated with metals and/or radionuclides. Not only should the proposed strategy be more effective at early identification of potential risks, this strategy should be significantly more cost effective because measurement of controlling boundary conditions and master variables is relatively simple. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume &#x27;ages&#x27;. This transformational long-term monitoring paradigm will generate significant cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Proceedings of the 2009 Performance Metrics for Intelligent Systems Workshop

The Performance Metrics for Intelligent Systems (PerMIS) workshop is dedicated to defining measures and methodologies of evaluating performance of intelligent systems. As the only workshop of its kind, PerMIS has proved to be an excellent forum for sharing lessons learned and discussions as well as fostering collaborations between researchers and practitioners from industry, academia and government agencies. The main theme of the ninth iteration of the workshop, PerMIS'09, seeks to address the question: 'Does performance measurement accelerate the pace of advancement for intelligent systems?' In addition to the main theme, as in previous years, the workshop will focus on applications of performance measures to practical problems in commercial, industrial, homeland security, and military applications. The PerMIS'09 program consists of six plenary addresses and six general and special sessions. The topics that are to be discussed by the speakers cover a wide array of themes centered on many intricate facets of intelligent system research. The presentations will emphasize and showcase the interdisciplinary nature of intelligent systems research and why it is not straightforward to evaluate such interconnected system of systems. The three days of twelve sessions will span themes from manufacturing, mobile robotics, human-system interaction, theory of mind, testing and evaluation of unmanned systems, to name a few.

42 ENGINEERING↗

Shifting the Paradigm for Long Term Monitoring at Legacy Sites to Improve Performance while Reducing Costs - 13422

A major issue facing many government and private industry sites that were previously contaminated with radioactive and chemical wastes is that often the sites cannot be cleaned up enough to permit unrestricted human access. These sites will require long-term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality in a cost effective manner. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site (SRS), the larger DOE complex, and many large federal and private sites. Currently, most monitoring strategies are focused on laboratory measurements of contaminants measured in groundwater samples collected from wells. This approach is expensive, and provides limited and lagging information about the effectiveness of cleanup activities and the behavior of the residual contamination. Over the last twenty years, DOE and other federal agencies have made significant investments in the development of various types of sensors and strategies that would allow for remote analysis of contaminants in groundwater, but these approaches do not promise significant reductions in risk or cost. Scientists at SRS have developed a new paradigm to simultaneously improve the performance of long term monitoring systems while lowering the overall cost of monitoring. This alternative approach incorporates traditional point measurements of contaminant concentration with measurements of controlling variables including boundary conditions, master variables, and traditional plume/contaminant variables. Boundary conditions are the overall driving forces that control plume movement and therefore provide leading indication to changes in plume stability. These variables include metrics associated with meteorology, hydrology, hydrogeology, and land use. Master variables are the key variables that control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. A robust suite of relatively inexpensive tools is commercially available to measure these variables. Traditional plume/contaminant variables are various measures of contaminant concentration including traditional analysis of chemicals in groundwater samples. An innovative long term monitoring strategy has been developed for acidic or caustic groundwater plumes contaminated with metals and/or radionuclides. Not only should the proposed strategy be more effective at early identification of potential risks, this strategy should be significantly more cost effective because measurement of controlling boundary conditions and master variables is relatively simple. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate significant cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance. (authors)

54 ENVIRONMENTAL SCIENCES↗

In-situ irradiation-induced studies of grain growth kinetics of nanocrystalline UO 2

The thermal conductivity of UO 2 fuel needs to be high enough to dissipate the heat generated from the fission reaction. Since grain size affects thermal conductivity and grain size can evolve with irradiation, it is critical to understand in-reactor UO 2 grain growth. Most studies of grain growth in UO 2 are based on thermally driven processes at elevated temperatures. However, studies have shown that grain growth can occur even at cryogenic temperatures by ballistic processes. Such irradiation-induced grain growth in UO 2 is yet to be studied. Advanced in-situ Kr ion irradiation and transmission electron microscopy were systematically performed on nanocrystalline UO 2 thin films at temperatures ranging from 50 K to 1073 K; grain growth was observed at all temperatures. A combination of manual and machine learning techniques was used to measure and plot grain size evolution against irradiation fluence at various irradiation temperatures. The machine learning method has significantly improved the analysis efficiency and reduced human labors. The grain diameter data were fitted using classical grain growth and thermal spike models to describe grain growth kinetics with and without irradiation effect. Grain growth during low temperature irradiation (≤ 475 K) can be well described by the thermal spike model. Above 475 K, there were additional thermally assisted processes that further accelerate the grain growth. At the highest irradiation temperature about 1075 K, both irradiation-induced dislocation loops and cavities/bubbles were observed to form in the UO 2 . In this report, the effects of irradiation-induced defects on grain growth kinetics are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗