Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bridges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Evaluation of wireless data communications at KSC

This project is motivated by the need for temporary or emergency provisioning of LAN service at KSC. The main goal of the project was to evaluate existing wireless bridge equipment in the KSC environment. Wireless bridge equipment can be used to make a wireless connection between two remotely located LAN segments. This report describes the experimental setup used to evaluate the equipment, including antenna connections, workstation connections, bridge software and workstation software The rangefinder program on the bridge was used to gather data about how the RF propagation environment at KSC affects the performance of the wireless bridge. Data was gathered for indoor as well as outdoor propagation. The report concludes with recommendations on how to take into account the particular terrain and building structures at KSC to design future applications of wireless bridges.

Gejji, Raghvendra R.↗

Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

Moreno, Michelle↗

Assessment of the Uniqueness of Wind Tunnel Strain-Gage Balance Load Predictions

A new test was developed to assess the uniqueness of wind tunnel strain-gage balance load predictions that are obtained from regression models of calibration data. The test helps balance users to gain confidence in load predictions of non-traditional balance designs. It also makes it possible to better evaluate load predictions of traditional balances that are not used as originally intended. The test works for both the Iterative and Non-Iterative Methods that are used in the aerospace testing community for the prediction of balance loads. It is based on the hypothesis that the total number of independently applied balance load components must always match the total number of independently measured bridge outputs or bridge output combinations. This hypothesis is supported by a control volume analysis of the inputs and outputs of a strain-gage balance. It is concluded from the control volume analysis that the loads and bridge outputs of a balance calibration data set must separately be tested for linear independence because it cannot always be guaranteed that a linearly independent load component set will result in linearly independent bridge output measurements. Simple linear math models for the loads and bridge outputs in combination with the variance inflation factor are used to test for linear independence. A highly unique and reversible mapping between the applied load component set and the measured bridge output set is guaranteed to exist if the maximum variance inflation factor of both sets is less than the literature recommended threshold of five. Data from the calibration of a six{component force balance is used to illustrate the application of the new test to real-world data.

strain-gage balance↗

Power converter circuitry for photovoltaic devices

Power converter circuitry includes a direct current (DC) input comprising a first DC input node and a second DC input node, an alternating current (AC) output comprising a first AC output node coupled to the first DC input node and a second AC output node, a first boost switch coupled between the second DC input node and a boost intermediate node, a second boost switch coupled between the boost intermediate node and a common node, a boost inductor coupled between the boost intermediate node and the first DC input node, a link capacitor coupled between the second DC input node and the common node, a first half-bridge switch coupled between the second DC input node and a half-bridge intermediate node, a second half-bridge switch coupled between the half-bridge intermediate node and the common node, and a half-bridge inductor coupled between the half-bridge intermediate node and the second AC output node.

Ayyanar, Rajapandian↗

3D‐Printed Carbon Nanoneedle Electrodes for Dopamine Detection in Drosophila

In vivo electrochemistry in small brain regions or synapses requires nanoelectrodes with long straight tips for submicron scale measurements. Nanoelectrodes can be fabricated using a Nanoscribe two-photon printer, but annealed tips curl if they are long and thin. We propose a new pulling-force strategy to fabricate a straight carbon nanoneedle structure. A micron-width bridge is printed between two blocks. The annealed structure shrinks during pyrolysis, and the blocks create a pulling force to form a long, thin, and straight carbon bridge. Parameterization study and COMSOL modeling indicate changes in the block size, bridge size and length affect the pulling force and bridge shrinkage. Electrodes were printed on niobium wires, insulated with aluminum oxide, and the bridge cut with focused ion beam (FIB) to expose the nanoneedle tip. Annealed needle diameters ranged from 400 nm to 5.25 μm and length varied from 50.5 μm to 146 μm. The electrochemical properties are similar to glassy carbon, with good performance for dopamine detection with fast-scan cyclic voltammetry. Nanoelectrodes enable biological applications, such as dopamine detection in a specific Drosophila brain region. Long and thin nanoneedles are generally useful for other applications such as cellular sensing, drug delivery, or gas sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Democratizing uncertainty quantification

Uncertainty Quantification (UQ) is vital to safety-critical model-based analyses, but the widespread adoption of sophisticated UQ methods is limited by technical complexity. In this paper, we introduce UM-Bridge (the UQ and Modeling Bridge), a high-level abstraction and software protocol that facilitates universal interoperability of UQ software with simulation codes. It breaks down the technical complexity of advanced UQ applications and enables separation of concerns between experts. UM-Bridge democratizes UQ by allowing effective interdisciplinary collaboration, accelerating the development of advanced UQ methods, and making it easy to perform UQ analyses from prototype to High Performance Computing (HPC) scale. In addition, we present a library of ready-to-run UQ benchmark problems, all easily accessible through UM-Bridge. These benchmarks support UQ methodology research, enabling reproducible performance comparisons. We demonstrate UM-Bridge with several scientific applications, harnessing HPC resources even using UQ codes not designed with HPC support.

Benchmarks↗

Electroreduction-Driven Formation and Connectivity of Polyoxometalate Coordination Networks

We present the synthesis of metal oxide coordination networks based on Preyssler-type polyoxoanions ([NaP 5 W 30 O 110 ] 14– and [NaP 5 MoW 29 O 110 ] 14– ) bridged with metal–aquo complexes ([M(H 2 O) n ] m+ , M m+ = Co 2+ , Ni 2+ , Zn 2+ , Y 3+ ), induced by electrochemical reduction. Networks bridged with first-row transition metals are isostructural with a previously reported Co-bridged structure, while the Y 3+ -bridged structure is new. All networks feature an uncommon binding motif of the metal cation to the oxygen atoms at cap positions, which we hypothesize is due to increased electron density at the cap upon reduction. Oxidation of a Zn 2+ -bridged network resulted in a new structure in which Zn 2+ –O cap bonds are lost, indicating the importance of reduction in the connectivity of these polyoxometalate-based coordination networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Binuclear Acetoniminato Derivatives of Iron and Chromium Carbonyls: A Theoretical Study

The structures and energetics of binuclear acetoniminato metal carbonyl derivatives of the types (Me 2 C═N) 2 Fe 2 (CO) n and (Me 2 C═N) 2 Cr 2 (CO) n have been investigated by density functional theory. The (Me 2 C═N) 2 Fe 2 (CO) 6 structure, with bridging Me 2 C═N ligands using only their nitrogen atoms to bridge an Fe═Fe bond related to experimentally known species, as well as a related (Me 2 C═N) 2 Cr 2 (CO) 8 structure, appear to be energetically preferred. Among carbonyl-richer systems, the iron system energetically prefers a {Me 2 C═NC(O)} 2 Fe 2 (CO) 6 structure with bridging Me 2 C═NC(O) ligands, whereas the chromium system energetically prefers a structure with a 2,3-diazabutadiene ligand having each nitrogen atom bonded to a Cr(CO) 5 moiety. Preferred structures for systems with fewer CO groups include the tetracarbonyl (Me 2 C═N) 2 Fe 2 (CO) 4 in which one of the bridging Me 2 C═N uses its C═N double bond to bond to an iron atom, as well as (Me 2 C═N)2Cr 2 (CO) n (n = 7, 6) structures with chromium–chromium multiple bonds bridged by Me2C═N groups.

Carbonyls↗

Prediction of the structures and heats of formation of MO 2 , MO 3 , and M 2 O 5 for M = V, Nb, Ta, Pa

Structures for the mono-, di-, and tri-bridge isomers of M 2 O 5 as well as those for the MO 2 and MO 3 fragments for M = V, Nb, Ta, and Pa were optimized at the density functional theory (DFT) level. Single point CCSD(T) calculations extrapolated to the complete basis set (CBS) limit at the DFT geometries were used to predict the energetics. Here, the lowest energy dimer isomer was the di-bridge for M = V and Nb and the tri-bridge for M = Ta and Pa. The di-bridge isomers were predicted to be composed of MO 2 + and MO 3 - fragments, whereas the mono- and tri-bridge are two MO 2 + fragments linked by an O 2 - . The heats of formation of M 2 O 5 dimers, as well as MO 2 and MO 3 neutral and ionic species were predicted using the Feller–Peterson–Dixon (FPD) approach. The heats of formation of the MF 5 species were calculated to provide additional benchmarks. Dimerization energies to form the M 2 O 5 dimers are predicted to become more negative going down group 5 and range from -29 to -45 kcal mol -1 . The ionization energies (IEs) for VO 2 and TaO 2 are essentially the same at 8.75 eV whereas the IEs for NbO 2 and PaO 2 are 8.10 and 6.25 eV, respectively. The predicted adiabatic electron affinities (AEAs) range from 3.75 eV to 4.45 eV for the MO 3 species and vertical detachment energies from 4.21 to 4.59 eV for MO 3 - . The calculated M[double bond, length as m-dash]O bond dissociation energies increase from 143 kcal mol -1 for M = V to ~170 kcal mol -1 for M = Nb and Ta to ~200 kcal mol -1 for M = Pa. The M–O bond dissociation energies are all similar ranging from 97 to 107 kcal mol -1 . Natural bond analysis provided insights into the types of chemical bonds in terms of their ionic character. Pa 2 O 5 is predicted to behave like an actinyl species dominated by the interactions of approximately linear PaO 2 + groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Site-specific electronic structure of covalently linked bimetallic dyads from nitrogen K-edge x-ray absorption spectroscopy

A nitrogen K-edge x-ray absorption near-edge structure (XANES) survey is presented for tetrapyrido[3,2-a:',3'-c:3'',2''-h:2''',3'''-j]phenazine (tpphz)-bridged bimetallic assemblies that couple chromophore and catalyst transition metal complexes for light driven catalysis, as well as their individual molecular constituents. We demonstrate the high N site sensitivity of the N pre-edge XANES features, which are energetically well-separated for the phenazine bridge N atoms and for the individual metal-bound N atoms of the inner coordination sphere ligands. By comparison with the time-dependent density functional theory calculated spectra, we determine the origins of these distinguishable spectral features. We find that metal coordination generates large shifts toward higher energy for the metal-bound N atoms, with increasing shift for 3d < 4d < 5d metal bonding. This is attributed to increasing ligand-to-metal σ donation that increases the effective charge of the bound N atoms and stabilizes the N 1s core electrons. In contrast, the phenazine bridge N pre-edge peak is found at a lower energy due to stabilization of the low energy electron accepting orbital localized on the phenazine motif. While no sensitivity to ground state electronic coupling between the individual molecular subunits was observed, the spectra are sensitive to structural distortions of the tpphz bridge. Here these results demonstrate N K-edge XANES as a local probe of electronic structure in large bridging ligand motifs, able to distinctly investigate the ligand-centered orbitals involved in metal-to-ligand and ligand-to-ligand electron transfer following light absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Basin & Range Investigation for Developing Geothermal Energy

Hidden geothermal systems represent a potentially prolific energy resource that could support critical U.S. public and government energy priorities. Basin and Range Investigations for Developing Geothermal Energy (BRIDGE) addressed some the challenges associated with hidden system exploration by prioritizing cost-effective exploration early on through strategic workflow and informed decision-making that mitigates early risk and shifts resources to later exploration stages (e.g., drilling). Sandia National Laboratories partnered with U.S. Navy Geothermal Office, Geologic Geothermal Group, and independent consultants, with additional collaboration with U.S. Geological Survey and private industry. The primary tool of the BRIDGE project was to deploy a regional-scale airborne electromagnetic method to investigate the shallow resistivity structure in areas with high prospectivity. This was followed up at several prospects by a multidisciplinary exploration approach, including additional geologic, geophysical and geochemical studies. A central tenet to the BRIDGE methodology is that zones of low resistivity frequently occur over geothermal systems in the Basin and Range, and when paired with other data constraints, imaging these zones can enable discovery of these systems. In addition to exploring greenfield areas (i.e., Grover Point), the BRIDGE project also flew HTEM resistivity surveys over known geothermal systems including those with established power plants (Don A. Campbell and Salt Wells) and prospects that are known to the literature but remain undeveloped, at least in part, due to a lack of understanding on the location of their producible reservoirs. BRIDGE produced a comprehensive set of data from prospects identified in the Nevada Play Fairway Analysis along with conceptual models for top ranking prospects, wherein all of the observations are used to inform an interpreted model of the system. These models present a range of possible system parameters such as temperature and size, and they are further informed by system analogues in the Basin and Range province and elsewhere. The results of this work leave space for further exploration that may now occur at prospects ‘down the list’ rather than distribution exploration resources evenly across all prospects.

15 GEOTHERMAL ENERGY↗

High power density dc/dc converter: Selection of converter topology

The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

Divan, Deepakraj M.↗

A Limited In-Flight Evaluation of the Constant Current Loop Strain Measurement Method

For many years, the Wheatstone bridge has been used successfully to measure electrical resistance and changes in that resistance. However, the inherent problem of varying lead wire resistance can cause errors when the Wheatstone bridge is used to measure strain in a flight environment. The constant current loop signal-conditioning card was developed to overcome that difficulty. This paper describes a limited evaluation of the constant current loop strain measurement method as used in the F-16XL ship 2 Supersonic Laminar Flow Control flight project. Several identical strain gages were installed in close proximity on a shock fence which was mounted under the left wing of the F- 1 6XL ship 2. Two strain gage bridges were configured using the constant current loop, and two were configured using the Wheatstone bridge circuitry. Flight data comparing the output from the constant current loop configured gages to that of the Wheatstone bridges with respect to signal output, error, and noise are given. Results indicate that the constant current loop strain measurement method enables an increased output, unaffected by lead wire resistance variations, to be obtained from strain gages.

Olney, Candida D.↗

Stability of Shapes Held by Surface Tension and Subjected to Flow

Results of three problems are summarized in this contribution. Each involves the fundamental capillary instability of an interfacial bridge and is an extension of previous work. The first two problems concern equilibrium shapes of liquid bridges near the stability boundary corresponding to maximum length (Plateau-Rayleigh limit). For the first problem, a previously formulated nonlinear theory to account for imposed gravity and interfacial shear disturbances in an isothermal environment is quantitatively tested in experiment. For the second problem, the liquid bridge is subjected to a shear that models the effect of a thermocapillary flow generated by a ring heater in a liquid encapsulated float-zone configuration. In the absence of gravity, this symmetric perturbation can stabilize the bridge to lengths on the order of 30 percent beyond the Plateau-Rayleigh limit, which is on the order of heretofore unexplained Shuttle observations. The third problem considers the dynamics of collapse and pinchoff of a film bridge (no gravity), which happens in the absence of stabilization. Here, we summarize experimental efforts to measure the self-similar cone-and-crater structure predicted by a previous theory.

Chen, Yi-Ju↗

Computer-aided design of a proton pump

The use of transmembrane proton gradients in energy transduction is an almost universal feature of life on earth. These proton gradients are established and maintained by specialized assemblies of proteins which actively pump protons across membranes. One broad class of proton pumps uses captured light energy to drive the proton pumping. Our goal is to elucidate the minimum structural requirements of a light-driven proton-pump. There are two basic components to a simple light-driven proton pump: a source of photo-generated protons and a "gate-keeper" which prevents these protons from reattaching themselves to their source. A wide variety of molecules in the membrane, even as simple as polycyclic aromatic hydrocarbons, are capable of releasing protons when illuminated. Our work is therefore focused on the design of the "gate-keeper." Our initial model involves a pair of proton acceptors, coupled to each other by a transient water bridge, and supported in the membrane by a small bundle of peptide helices. Upon illumination, the proton source transfers its proton to the:- first acceptor of the gate-keeper. While the reverse reaction is highly probable, all that is needed to ensure irreversibility is a nonvanishing probability that the proton will be transferred to the second acceptor across a transient water bridge. Back transfer of the proton to the first acceptor, and thence to the proton source, is impeded by the free energy required to move the proton uphill towards the. proton source and by the disruption of the transient water bridge. As a prototypical water-bridged proton transfer system, we are studying the transfer of a proton across a water bridge from a formic acid to a formate anion. With a pK(sub alpha), of 3.7. formic acid is a good model for the acidic amino acids glutamate and aspartate which are good candidates for gate-keeper proton acceptors. Simulations of proton transfer reactions in a membrane are complicated by the quantum mechanical nature of the process breaking and forming chemical bonds.

New, Michael H.↗

SiC-Based Miniature High-Temperature Cantilever Anemometer

The figure depicts a miniature cantilever-type anemometer that has been developed as a prototype of compact, relatively nonintrusive anemometers that can function at temperatures up to 600 C and that can be expected to be commercially mass-producible at low cost. The design of this anemometer, and especially the packaging aspect of the design, is intended to enable measurement of turbulence in the high-temperature, high-vibration environment of a turbine engine or in any similar environment. The main structural components of the anemometer include a single-crystal SiC cantilever and two polycrystalline SiC clamping plates, all made from chemical-vapor-deposited silicon carbide. Fabrication of these components from the same basic material eliminates thermal-expansion mismatch, which has introduced spurious thermomechanical stresses in cantilever-type anemometers of prior design. The clamping plates are heavily oxidized to improve electrical insulation at high temperature. A cavity that serves as a receptacle for the clamped end of the cantilever is etched into one end of one clamping plate. Trenches that collectively constitute a socket for a multipin electrical plug (for connection to external electronic circuitry) are etched into the opposite end of this clamping plate. Metal strips for electrical contact are deposited on one face of the other clamping plate. Piezoresistive single-crystal SiC thin-film strain gauges are etched in the n-type SiC epilayer in a Wheatstone-bridge configuration. Metal contact pads on the cantilever that extend into the clamping-receptacle area, are obtained by deposition and patterning using standard semiconductor photolithography and etching methods. The cantilever and the two clamping plates are assembled into a sandwich structure that is then clamped in a stainless-steel housing. The Wheatstone- bridge carrying SiC cantilever with the metal contact pads on the piezoresistors is slid into the receptacle in the bottom clamping plate. The top clamping plate is brought into contact with the bottom plate so that the narrow section of the metal strips on the top clamp plate aligns with the metal contact pads on the cantilever. When the parts are clamped together, the metal strips provide electrical connections between the Wheatstone-bridge contact points and the sides the trenches that constitute the socket for the multipin electrical plug. Hence, to connect the Wheatstone bridge to external circuitry for processing of the anemometer readout, one need only insert the plug in the socket. In operation, the cantilever end of the stainless-steel housing is mounted flush with an engine wall and the unclamped portion of the cantilever is exposed into the flow. The cantilever is deflected in direct proportion to the force induced by component of flow parallel to the engine wall and perpendicular to the broad exposed face of the cantilever. The maximum strain on the cantilever occurs at the clamped edge and is measured by the piezoresistors, which are located there. The corresponding changes in resistance manifest themselves in the output of the Wheatstone bridge.

Okojie, Robert S.↗

A Novel Method for Characterizing Fatigue Delamination Growth Under Mode I Using the Double Cantilever Beam Specimen

A novel method is proposed to obtain Mode I delamination growth rate from a Double Cantilever Beam (DCB) specimen. In the proposed method, Unidirectional (UD) DCB specimens are tested in fatigue at different initial maximum energy release rates levels. The growth rate data obtained in the first increments of crack growth at each maximum energy release rate level are used to generate a Paris Law equation, which characterizes delamination growth rate without fiber-bridging, and can also be used to determine a delamination onset curve. The remaining delamination growth rate data from each test are used to determine a modified Paris law, which characterizes the delamination growth rate in a DCB specimen, explicitly accounting for fiber-bridging. The proposed expression captures well the scatter in experimental data obtained using the DCB specimens, suggesting its adequacy. The Paris Law characterizing delamination growth rate without fiber-bridging predicts higher delamination growth rates for the same maximum energy release rate applied, leading to a conservative estimate for delamination growth. This is particularly relevant, since in generic ply interfaces, fiber-bridging is less predominant than in UD DCB specimens. Failing to account for fiber-bridging in UD DCB specimens may underestimate the delamination growth rate, yielding non-conservative predictions.

Carvalho, Nelson↗

Determining True Sensor Spatial Resolution of Very High Resolution Optical Imagery

Some satellite data is delivered in images with gridded pixels. This gridded pixel size is often assumed to be the spatial resolution of the satellite sensor; however, this is not always the case. An image can be grided to any arbitrary pixel size, but the sensor resolution will remain constant. For example, an image with a pixel grid size much smaller than the sensor resolution will appear blurry along what should be sharp transitions. This discrepancy between an image’s pixel size and true sensor spatial resolution can be the source of much confusion and even misinformation among data users, which may lead them to waste time and resources on using images that do not suit their spatial resolution needs. This presentation will highlight our evaluation of the true spatial resolution of various government and commercial images in the pixel size range of 0.3 m to 60 m. Images evaluated include ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels). Our evaluation of true sensor spatial resolution, or ‘footprint size’ is based on the sensor’s line spread function (LSF). We calculate the width at half the height of the LSF to find the full width at half maximum (FWHM). The FWHM is how we report sensor spatial resolution. Different objects are examined for constructing the LSF depending on the sensor spatial resolution. Coarser resolution sensors in this evaluation such as Sentinel-2 and Landsat 8/9 are examined at bridges over a dark water background. The bright bridge acts as a line impulse, giving a sensor’s line spread function (LSF) in one direction. Additionally, we simulate the impacts of bridge width on the apparent LSF to obtain a true LSF without the effects of bridge width for these sensors. Finer resolution sensors will image the irregularities in bridges such as trusses, sidewalks, and in some cases painted lines, interfering with the LSF construction. Instead, these sensors are evaluated at large (60 m – 140 m) black and white checkerboards known as Cal/Val sites. At these locations, the image’s transition from black to white is extracted as an edge spread function (ESF). We calculate the derivative of this ESF to obtain the sensor’s LSF. From there, we find the FWHM as we do for the coarser resolution images. With the FWHM and pixel size, we determine how over- or under-sampled the images are. When the ratio of a sensor’s spatial resolution and the gridded image’s pixel size is less than 1, the image is considered under-sampled. In this case, each pixel’s information is unique but only a portion of that pixel’s ground area has been measured. On the other side, if the ratio is greater than 1, the image is considered over-sampled. That is, each pixel’s information is sourced from within the ground extent of the pixel and some extent outside additionally. We will show the true spatial resolution and the extent of over-/under-sampling in the imagery from ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels).

Alana Semple↗