Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei↗

SU-F-T-178: Optimized Design of a Diamond Detector Specifically Dedicated to the Dose Distribution Measurements in Clinical Proton Pencil Beams

Purpose: In proton-therapy, pencil beam scanning (PBS) dosimetry presents a real challenge due to the small size of the beam (about 3 to 8 mm in FWHM), the pulsed high dose rate (up to 100 Gy/s) and the proton energy variation (about 30 MeV to 250 MeV). In the framework of French INSERM DEDIPRO project, a specifically dedicated single crystal diamond dosimeter (SCDDo) was developed with the objective of obtaining accurate measurements of the dose distribution in PBS modality. Methods: Monte Carlo simulations with MCNPX were performed. A small proton beam of 5 mm in FWHM was simulated as well as diamond devices with various size, thickness and holder composition. The calculated doses-to-diamond were compared with the doses-to-water in order to reduce the perturbation effects. Monte-Carlo simulations lead to an optimized SCDDo design for small proton beams dosimetry. Following the optimized design, SCDDos were mounted in water-equivalent holders with electrical connection adapted to standard electrometer. First, SCDDos performances (stability, repeatability, signal-to-background ratio…) were evaluated with conventional photon beams. Then, characterizations (dose linearity, dose rate dependence…) with wide proton beams were performed at proton-therapy center (IC-CPO) from Curie Institute (France) with the passive proton delivery technique, in order to confirm dosimetric requirements. Finally, depth-dose distributions were measured in a water tank, for native and modulated Bragg Peaks with the collimator of 12 cm, and compared to a commercial PPC05 parallel-plate ionization chamber reference detector. Lateral-dose profiles were also measured with the collimator of 5 mm, and compared to a commercial SFD diode. Results: The results show that SCDDo design does not disturb the dose distributions. Conclusion: The experimental dose distributions with the SCDDo are in good agreement with the commercial detectors and no energy dependence was observed with this device configuration.

07 ISOTOPE AND RADIATION SOURCES↗

Cooling Duct Analysis for Transpiration/Film Cooled Liquid Propellant Rocket Engines

The development of a low cost space transportation system requires that the propulsion system be reusable, have long life, with good performance and use low cost propellants. Improved performance can be achieved by operating the engine at higher pressure and temperature levels than previous designs. Increasing the chamber pressure and temperature, however, will increase wall heating rates. This necessitates the need for active cooling methods such as film cooling or transpiration cooling. But active cooling can reduce the net thrust of the engine and add considerably to the design complexity. Recently, a metal drawing process has been patented where it is possible to fabricate plates with very small holes with high uniformity with a closely specified porosity. Such a metal plate could be used for an inexpensive transpiration/film cooled liner to meet the demands of advanced reusable rocket engines, if coolant mass flow rates could be controlled to satisfy wall cooling requirements and performance. The present study investigates the possibility of controlling the coolant mass flow rate through the porous material by simple non-active fluid dynamic means. The coolant will be supplied to the porous material by series of constant geometry slots machined on the exterior of the engine.

Micklow, Gerald J.↗

Lunar gravity derived from long-period satellite motion, a proposed method

A method was devised to determine the spherical harmonic coefficients of the lunar gravity field. The method consists of a two-step data reduction and estimation process. Pseudo-Doppler data were generated simulating two different lunar orbits. The analysis included the perturbing effects of the L1 lunar gravity field, the earth, the sun, and solar radiation pressure. Orbit determinations were performed on these data and long-period orbital elements were obtained. The Kepler element rates from these solutions were used to recover L1 lunar gravity coefficients. Overall results of the experiment show that lunar gravity coefficients can be accurately determined and that the method is dynamically consistent with long-period perturbation theory.

Ferrari, A. J.↗

Ductal Carcinoma In Situ with Microinvasion on Core Biopsy: Evaluating Tumor Upstaging Rate, Lymph Node Metastasis Rate, and Associated Predictive Variables

Introduction: The role of sentinel lymph node biopsy (SLNB) when ductal carcinoma in situ with microinvasion (DCISM) is identified on core biopsy is unclear. Objective: Our aim was to assess the upstage rate to invasive cancer and axillary lymph node metastasis in patients diagnosed with DCISM, and whether predictive variables could be identified that may help inform who would most likely benefit from a surgical axillary evaluation. Methods: We performed a retrospective review of 70 patients diagnosed with DCISM on core biopsy. Patients with concomitant or prior invasive cancer were excluded. Demographic, clinical, radiographic, histologic, and treatment data were collected. Fisher’s exact test and univariable and multivariable logistic regression were performed to identify variables that may be associated with tumor upstaging and nodal metastasis. Time-to-event distributions were summarized using the Kaplan–Meier method. Results: On final surgical pathology, 49 patients (70%) had a final diagnosis of DCISM or T1mi cancer, whereas 21 patients (30%) were upstaged to measurable invasive cancer (> 1 mm). One of 49 patients (2%) with DCISM on final pathology and 4 of 21 patients (19%) with measurable invasive cancer showed sentinel lymph node metastases. Conclusion: Although the upstage rate to measurable invasive cancer in our cohort of patients with DCISM on core biopsy was 30%, findings of a positive SLNB remain low at 7%. No predictive variables were identified to inform whether the routine practice of SLNB may be omitted in some patients with DCISM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

Thin film surface modifications of thin/tunable liquid/gas diffusion layers for high-efficiency proton exchange membrane electrolyzer cells

We present that a proton exchange membrane electrolyzer cell (PEMEC) is one of the most promising devices for high-efficiency and low-cost energy storage and ultrahigh purity hydrogen production. As one of the critical components in PEMECs, the titanium thin/tunable LGDL (TT-LGDL) with its advantages of small thickness, planar surface, straight-through pores, and well-controlled pore morphologies, achieved superior multifunctional performance for hydrogen and oxygen production from water splitting even at low temperature. Different thin film surface treatments on the novel TT-LGDLs for enhancing the interfacial contacts and PEMEC performance were investigated both in-situ and ex-situ for the first time. Surface modified TT-LGDLs with about 180 nm thick Au thin film yielded performance improvement (voltage reduction), from 1.6849 V with untreated TT-LGDLs to only 1.6328 V with treated TT-LGDLs at 2.0 A/cm 2 and 80°C. Furthermore, the hydrogen/oxygen production rate was increased by about 28.2% at 1.60 V and 80°C. The durability test demonstrated that the surface treated TT-LGDL has good stability as well. Finally, the gold electroplating surface treatment is a promising method for the PEMEC performance enhancement and titanium material protection even in harsh environment.

08 HYDROGEN↗

Synthetic Evaluation of Infrasonic Multipole Waveform Inversion

Acoustic source inversions estimate the mass flow rate of volcanic explosions or yield of chemical explosions and provide insight into potential source directionality. However, the limitations of applying these methods to complex sources and their ability to resolve a stable solution have not been investigated in detail. We perform synthetic infrasound waveform inversions that use 3-D Green’s functions for a variety of idealized and realistic deployment scenarios using both a flat plane and Yasur volcano, Vanuatu as examples. We investigate the ability of various scenarios to retrieve the input source functions and relative amplitudes for monopole and multipole (monopole and dipole) inversions. Infrasound waveform inversions appear to be a robust method to quantify mass flow rates from simple sources (monopole) using deployments of infrasound sensors placed around a source, but care should be taken when analyzing and interpreting results from more complex acoustic sources (multipole) that have significant directional components. In the examples we consider the solution is stable for monopole inversions with a signal-to-noise ratio greater than five and the dipole component is small. For most scenarios investigated, the vertical dipole component of the multipole explosion source is poorly constrained and can impact the ability to recover the other source term components. Because multipole inversions are ill-posed for many deployments, a low residual does not necessarily mean the proper source vector has been recovered. Synthetic studies are able to help investigate the limitations and place bounds on information that may be missing using monopole and multipole inversions for potentially directional sources.

58 GEOSCIENCES↗

Comparative Study of Finite Element Methods Using the Time-Accuracy-Size(TAS) Spectrum Analysis

We present a performance analysis appropriate for comparing algorithms using different numerical discretizations. By taking into account the total time-to-solution, numerical accuracy with respect to an error norm, and the computation rate, a cost-benefit analysis can be performed to determine which algorithm and discretization are particularly suited for an application. This work extends the performance spectrum model in for interpretation of hardware and algorithmic tradeoffs in numerical PDE simulation. As a proof-of-concept, popular finite element software packages are used to illustrate this analysis for Poisson’s equation.

97 MATHEMATICS AND COMPUTING↗

Semiautomatic segmentation of aortic valve from sequenced ultrasound image using a novel shape-constraint GCV model

Purpose: Effective and accurate segmentation of the aortic valve (AV) from sequenced ultrasound (US) images remains a technical challenge because of intrinsic factors of ultrasound images that impact the quality and the continuous changes of shape and position of segmented objects. In this paper, a novel shape-constraint gradient Chan-Vese (GCV) model is proposed for segmenting the AV from time serial echocardiography. Methods: The GCV model is derived by incorporating the energy of the gradient vector flow into a CV model framework, where the gradient vector energy term is introduced by calculating the deviation angle between the inward normal force of the evolution contour and the gradient vector force. The flow force enlarges the capture range and enhances the blurred boundaries of objects. This is achieved by adding a circle-like contour (constructed using the AV structure region as a constraint shape) as an energy item to the GCV model through the shape comparison function. This shape-constrained energy can enhance the image constraint force by effectively connecting separate gaps of the object edge as well as driving the evolution contour to quickly approach the ideal object. Because of the slight movement of the AV in adjacent frames, the initial constraint shape is defined by users, with the other constraint shapes being derived from the segmentation results of adjacent sequence frames after morphological filtering. The AV is segmented from the US images by minimizing the proposed energy function. Results: To evaluate the performance of the proposed method, five assessment parameters were used to compare it with manual delineations performed by radiologists (gold standards). Three hundred and fifteen images acquired from nine groups were analyzed in the experiment. The area-metric overlap error rate was 6.89% ± 2.88%, the relative area difference rate 3.94% ± 2.63%, the average symmetric contour distance 1.08 ± 0.43 mm, the root mean square symmetric contour distance 1.37 ± 0.52 mm, and the maximum symmetric contour distance was 3.57 ± 1.72 mm. Conclusions: Compared with the CV model, as a result of the combination of the gradient vector and neighborhood shape information, this semiautomatic segmentation method significantly improves the accuracy and robustness of AV segmentation, making it feasible for improved segmentation of aortic valves from US images that have fuzzy boundaries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FedOSAA: Improving Federated Learning with One-Step Anderson Acceleration

Federated learning (FL) is a distributed machine learning approach that enables multiple local clients and a central server to collaboratively train a model while keeping the data on their own devices. First-order methods, particularly those incorporating variance reduction techniques, are the most widely used FL algorithms due to their simple implementation and stable performance. However, these methods tend to be slow and require a large number of communication rounds to reach the global minimizer. We propose FedOSAA, a novel approach that preserves the simplicity of first-order methods while achieving the rapid convergence typically associated with second-order methods. Our approach applies one Anderson acceleration (AA) step following classical local updates based on first-order methods with variance reduction, such as FedSVRG and SCAFFOLD, during local training. This AA step is able to leverage curvature information from the history points and gives a new update that approximates the Newton-GMRES direction, thereby significantly improving the convergence. We establish a local linear convergence rate to the global minimizer of FedOSAA for smooth and strongly convex loss functions. Numerical comparisons show that FedOSAA substantially improves the communication and computation efficiency of the original first-order methods, achieving performance comparable to second-order methods like GIANT.

Feng, Xue [University of California, Davis]↗

Data-driven methods for diffusivity prediction in nuclear fuels

The growth rate of structural defects in nuclear fuels under irradiation is intrinsically related to the diffusion rates of the defects in the fuel lattice. The generation and growth of atomistic structural defects can significantly alter the performance characteristics of the fuel. This alteration of functionality must be accurately captured to qualify a nuclear fuel for use in reactors. Predicting the diffusion coefficients of defects and how they impact macroscale properties such as swelling, gas release, and creep is therefore of significant importance in both the design of new nuclear fuels and the assessment of current fuel types. In this article, we apply data-driven methods focusing on machine learning (ML) to determine various diffusion properties of two nuclear fuels—uranium oxide and uranium nitride. We show that using ML can increase, often significantly, the accuracy of predicting diffusivity in nuclear fuels in comparison to current analytical models. We also illustrate how ML can be used to quickly develop fuel models with parameter dependencies that are more complex and robust than what is currently available in the literature. In conclusion, these results suggest there is potential for ML to accelerate the design, qualification, and implementation of nuclear fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy release rate approximation for edge cracks using higher-order topological derivatives

Topological derivatives provide the variation of a functional when an infinitesimal hole is introduced into the domain. In Silva et al. (J Mech Phys Solids 59(5):925–939, 2011), the authors developed a first-order approximation of the energy release rate associated with a small crack at any boundary location and at any orientation using a first-order topological derivative. This approach offers significant computational advantages over other methods because (i) it requires only a single analysis while other methods require an analysis for each crack size-location-direction combination, and (ii) it is performed on the non-cracked domain, removing the need to create very fine meshes in the vicinity of the crack. In the present study, higher-precision approximations of the energy release rate are developed using higher-order topological derivatives which allow the analyst to accurately treat longer cracks and determine the crack lengths for which the first-order approximation is accurate.

42 ENGINEERING↗

Inter-well connectivity detection in CO 2 WAG projects using statistical recurrent unit models

Routine well-wise injection and production measurements contain significant information on subsurface structure and properties. Data-driven technology that interprets surface data into subsurface structure or properties can assist operators in making informed decisions by providing a better understanding of field assets. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO 2 EOR projects utilizing the water-alternating-gas (WAG) process. SRU is a special type of recurrent neural network (RNN) that allows for better characterization of temporal trends, by learning various statistics of the input at different time scales. In our application, the complete states (injection rate, pressure and cumulative injection) at injectors and pressure states at producers are fed to SRU as the input and the phase rates at producers are treated as the output. Once the SRU is trained and validated, it is then used to assess the connectivity of each injector to any producer using permutation variable importance method, wherein inputs corresponding to an injector are shuffled and the increase in prediction error at a given producer is recorded as the importance (connectivity metric) of the injector to the producer. This method is tested in both synthetic and field-scale cases. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. This significantly improves confidence in our data-driven procedure. The novelty of this work is that it is purely data-driven method and can directly interpret routine surface measurements to intuitive subsurface knowledge. Furthermore, the streamline-based validation procedure provides physics-based backing to the results obtained from data analytics. This study results in a reliable and efficient data analytics framework that is well-suited for large field applications.

42 ENGINEERING↗

Cryogenic Carbon Capture Development (Final Report)

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant. The specific areas of work in this project are: Budget Period 1: 1) Selection of the most energy-efficient drying system for ambient-pressure flue gas. Sustainable Energy Solutions, LLC (SES) has successfully demonstrated a dryer that removes bulk water using a low-temperature brine to remove about 99% of the water followed by a mol sieve 3A desiccant dryer to remove the remaining 1% water; 2) Selection and demonstration of efficient solution to fouling due to dissolved CO 2 . SES has tested several commercial heat exchangers that purport to be able to handle fouling issues similar to those experienced in the contact liquid chiller. Replicated tests using the CCC ECL™ skid and dimpled brazed plate heat exchangers demonstrate that quick throttling of refrigerant combined with a burst of clean gas mitigate the fouling caused by CO 2 solubility in contact liquid with only minor increases in parasitic load. SES models indicate that parasitic load would increase by approximately 0.0125 GJ/tonne, an order of magnitude less than what was determined to be the maximum allowable additional parasitic load caused by this system; 3) Selection and demonstration of efficient and scalable solid–liquid separation system. The screw press technology met or exceeded the 70% solids loading benchmark during several test runs exceeding 24 hours on the CCC ECL™ skid. The average solids loading during the entire 50-hour run was 67%. The energy demand for this system is less than 0.1 GJ e /tonne of CO 2 processed; 4) Optimize design and demonstration of patented desublimating heat exchangers. We designed and built a hybrid spray tower that was tested over many hundreds of hours and a 50-hour continuous test run was completed capturing over 0.5 tonne CO 2 /day at >90% capture; (5) Plan for safe dilution of oxygen-depleted, cleaned flue-gas stream. The AERSCREEN simulator developed by the EPA modeled the dispersion of oxygen-depleted flue gas from the CCC process at a commercial plant. The results indicate that this plan effectively mitigates the flue gas hazards; (6) Simulation of and experimental work related to multi-pollutant capture. SES programmed an upgrade to its solid/vapor/liquid equilibrium (SVLE) algorithm. This enables simultaneous modeling of multiple pollutants (i.e., CO 2 , SO x , NO x , Hg, HCl). Budget Period 2; (7) Modify the CCC ECL™ skid for field testing and complete shakedown testing. The plans for modifying the CCC ECL™ skid were finalized and put into place. Shakedown testing of the updated CCC ECL™ skid occurred at SES using closed-loop mode (i.e., using a synthetic flue gas consisting of only N 2 and CO 2 ) and at the Hunter Power Plant using flue gas from the coal-fired boiler. Shakedown testing took longer than expected due to delays in receiving equipment and unexpected equipment performance in the field; (8) Operate the CCC ECL™ skid in the field. Longer testing of the CCC ECL™ skid occurred at the Hunter Power Plant. Multiple tests exceeding 35 hours were completed, with a total of over 600 hours of CO 2 capture completed using flue gas at the Hunter Power Plant with an average CO 2 capture rate of over 91% during those hours. Extensive notes and documentation were acquired informing improved methods for controls, startup, operation, and shut down; (9) Determine figures of merit and quantify process improvement. SES defined figures of merit for unit operation performance and overall CCC ECL™ process performance. All figures of merit were achieved or surpassed, except for 500 continuous hours of demonstration at the Hunter Power Plant; (10) Complete an Environmental Health and Safety Risk assessment by a third party. Tri-State completed an Environmental Health and Safety Risk assessment; (11) Update techno-economic analysis with third-party validation. The techno-economic analysis has been completed. It confirms the potential large reduction in energy and cost of the CCC process compared with leading alternatives and that the estimates and estimation techniques are reliable.

20 FOSSIL-FUELED POWER PLANTS↗

Computation of atmospheric cooling rates by exact and approximate methods

Infrared fluxes and cooling rates for several standard model atmospheres, with and without water vapor, carbon dioxide, and ozone, have been calculated using a line-by-line method at 0.01/cm resolution. The sensitivity of the results to the vertical integration scheme and to the model for water vapor continuum absorption is shown. Comparison with similar calculations performed at NOAA/GFDL shows agreement to within 0.5 W/sq m in fluxes at various levels and 0.05 K/d in cooling rates. Comparison with a fast, parameterized radiation code used in climate models reveals a worst case difference, when all gases are included, of 3.7 W/sq m in flux; cooling rate differences are 0.1 K/d or less when integrated over a substantial layer with point differences as large as 0.3 K/d.

Ridgway, William L.↗

Numerical study to predict the effect of surface roughness on the thermal and hydraulic performance of additively manufactured heat exchangers

Heat exchangers are used in many industries to transfer thermal energy between two or more objects with an associated thermal and hydraulic performance indicated by thermal effectiveness and pressure drop respectively. Many investigations have aimed to enhance the thermal effectiveness of heat exchangers by introducing turbulent flow inducers that increase the heat transfer rate at the expense of increasing pressure drop. Flow inducers like surface roughness can be controlled with advanced manufacturing methods like additive manufacturing for heat exchanger production. Selecting and manufacturing an optimal surface roughness for heat exchangers requires a more comprehensive approach that accounts for the surface roughness effect on the thermal and hydraulic performance of a sample. Since fabricating samples with additive manufacturing to a desired surface roughness can be an extensive experimental process, this study will fundamentally investigate the effect of surface roughness on the thermal and velocity boundary layers for various surface roughness profiles with physics-based computational modeling. To accurately model the surface roughness effect on thermohydraulic performance, correlations like roughness ratio, friction factor, and Nusselt number are investigated. This study expects to indicate correlations for different flow regimes which can successfully predict the effect of surface roughness on thermohydraulic performance. Results generated from modeling surface roughness effect with unique correlations are then compared to experimental data obtained from literature for validation. The results of this study will provide insight to understand the thermal fluid physics associated with surface roughness and design guidelines for heat exchangers produced with additive manufacturing.

36 MATERIALS SCIENCE↗

A comparison of microwave techniques for measuring rainfall

The purpose of this paper is to evaluate within a common framework a large number of techniques for nearly instantaneous microwave measurements of rainfall and to determine the range of rainfall rates best suited to the various techniques and estimators. The physical basis of a technique as transformed by measurement imperfections of real instruments determines the ultimate performance capability of any microwave rain estimator. While many of the defects of the measurement process apply to all techniques, the physics behind each estimator differs. A method is presented for objectively evaluating the physical bases of the techniques and for quantifying estimator performance for perfect instruments. These results are then tempered by standard measurement errors to yield more realistic results. Analysis demonstrates that, in general, the minimization of rainfall estimate errors over a wide range of rainfall rates requires the simultaneous application of more than one microwave rainfall measurement technique.

Jameson, A. R.↗