Probe measurements in an electrodeless discharge.
Radial distributions of number density, electron temperature and plasma potential measured in electrodeless discharge, using symmetric and asymmetric double probes
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Radial distributions of number density, electron temperature and plasma potential measured in electrodeless discharge, using symmetric and asymmetric double probes
Flux, energy distribution and density of ions and electrons in magnetosphere plasma during solar activity period determined by OGO-C electrostatic probes
The mass of the hydrogen isotope in micrometer-sized aqueous droplets introduced into an ICP has been found to affect the degree of resulting plasma perturbation. Studied plasma perturbations include local plasma cooling, plasma shrinkage due to thermal pinching, and changes in plasma impedance. The local cooling effect caused by a vaporizing aerosol droplet was found to be similar between H 2 O and D 2 O. This finding is likely a result of the similar heat capacities and vaporization rates of H 2 O and D 2 O droplets and of the comparable thermal conductivities and dissociation kinetics of H 2 O and D 2 O vapor. In contrast, a clear isotope effect was observed for plasma shrinkage and impedance change, with H 2 O causing a considerably stronger effect. Plasma shrinkage, gauged by the reduction in Ar emission at the edge of the plasma, was detected at all observation heights within the load-coil region, with D 2 O droplets causing as much as 30% less of an effect than H 2 O. Likewise, D 2 O droplets induce significantly less change in plasma impedance than H 2 O droplets. Depending on experimental conditions and the probing method, changes in plasma impedance caused by monodisperse D 2 O droplets were only 52%–80% that of H 2 O. The lower influence on plasma shrinkage and impedance change for D 2 O droplets is believed to be related to the much lower thermal conductivity of atomic deuterium, around 70% that of atomic hydrogen (protium). The time required for the plasma impedance to return to its original steady-state value was comparatively long (~10 ms) and similar for H 2 O and D 2 O droplets.
A new scheme using centrosymmetric materials as sensor medium is presented for the single-shot coherence detection of terahertz pulse. The method relies on the electric-field-induced optical second-harmonic generation with linearly chirped optical probe pulse in centrosymmetric medium. The terahertz field is encoded onto the frequency spectrum of the second-harmonic pulse and then decoded with appropriate retrieval algorithm. This approach provides a broadband coherent spectroscopic measurement that can cover the entire terahertz gap and has transform-limited temporal resolution, which is mainly limited by the spectral bandwidth of the optical probe pulse. It can be used widely in the experiments of high field plasma physics and the diagnostics of warm dense plasmas.
UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.
Results are presented from experimental and theoretical investigations of oscillatory and wave phenomena observed in the edge region in the U-3M torsatron during plasma creation and heating by an RF discharge in the ICR frequency range, accompanied by a transition to improved confinement. The main results are reported of diagnostic measurements of the spectral composition of oscillations, as well as of how the phase and amplitude relationships depend on time and on the RF power during its injection into the plasma. The measurements were carried out with electrostatic probes positioned at the edge of the plasma confinement region. The experimental results are interpreted using the kinetic theory of the electron-ion parametric instability of a plasma in the ion cyclotron frequency range and are compared with the results of numerical simulations.
Plasmas are collections of charged particles that can exhibit an impressively diverse set of collective phenomena. They exist in an extraordinary variety of environments and span a great range of densities and temperatures, from 15 million kelvin in the core of the Sun to 200 K in the ionosphere and from 10{sup 30} particles per cubic centimeter in a white dwarf to 1 particle per cm{sup 3} in interstellar space. They can find application in lighting sources, manufacturing of computer chips, and fusion energy research. Plasmas created in the laboratory are used to replicate and study those that occur naturally and to probe the fundamental and complex behavior of plasmas.
An electron cyclotron resonance plasma produced in a cylindrical waveguide with external permanent magnets was investigated as a possible plasma cathode electron source. The configuration is desirable in that it eliminates the need for a physical antenna inserted into the plasma, the erosion of which limits operating lifetime. Plasma bulk density was found to be overdense in the source. Extraction currents over 4 A were achieved with the device. Measurements of extracted electron currents were similar to calculated currents, which were estimated using Langmuir probe measurements at the plasma cathode orifice and along the length of the external plume. The influence of facility effects and trace ionization in the anode-cathode gap are also discussed.
Proton imaging is a powerful tool for probing electromagnetic fields in a plasma, providing a path-integrated map of the field topology. However, in cases where the field structure is highly inhomogeneous, inferring spatial properties of the underlying field from proton images can be difficult. This problem is exemplified by recent experiments, which used proton imaging to probe the filamentary magnetic field structures produced by the Weibel instability in collisionless counterstreaming plasmas. In this paper, we perform analytical and numerical analyses of proton images of systems containing many magnetic filaments. We find that, in general, the features observed on proton images do not directly correspond to the spacing between magnetic filaments (the magnetic wavelength) as has previously been assumed and that they instead correspond to the filament size. Furthermore, we demonstrate this result by Fourier analysis of synthetic proton images for many randomized configurations of magnetic filaments. Our results help guide the interpretation of experimental proton images of filamentary magnetic structures in plasmas.
A comprehensive set of investigations involving arcing on a negatively biased anodized aluminum plate immersed in a low density argon plasma at low pressures (P(sub O), 7.5 x 10(exp -5) Torr) have been performed. These arcing experiments were designed to simulate electrical breakdown of anodized coatings in a Low Earth Orbital (LEO) environment. When electrical breakdown of an anodized layer occurs, an arc strikes, and there is a sudden flux of electrons accelerated into the ambient plasma. This event is directly followed by ejection of a quasi-neutral plasma cloud consisting of ejected material blown out of the anodized layer. Statistical analysis of plasma cloud expansion velocities have yielded a mean propagation velocity, v = (19.4 +/- 3.5) km/s. As the plasma cloud expands into the ambient plasma, energy in the form of electrical noise is generated. The radiated electromagnetic noise is detected by means of an insulated antenna immersed in the ambient plasma. The purpose of the investigations is (1) to observe and record the electromagnetic radiation spectrum resulting from the arcing process. (2) Make estimates of the travel time of the quasi-neutral plasma cloud based on fluctuations to several Langmuir probes mounted in the ambient plasma. (3) To study induced arcing between two anodized aluminum structures in close proximity.
A numerical simulation has been made of the 'pinhole effect' which produces the characteristic 'S-shaped' current-voltage curve. A disk-shaped conducting probe immersed in a plasma is modeled using a particle-in-cell (PIC) code. A probe partially covered by a very thin insulating layer is considered, as well as a probe mounted on an insulating disk. The simulation uses a cylindrical particle mover and allows for a variable number of particles in the system. The simulation space grid uses three different mesh sizes, the coarsest being away from the probe and the finest near the probe, in order to accurately calculate the trajectories of the simulation particles contributing the current to the probe and to the surface charge density on the dielectric. The calculation of the electrostatic potential is done self-consistently using successive over-relaxation (SOR). Backscattering and secondary electron emission are included for the case of positive probe voltage.
Physical properties of low-pressure inductively coupled argon, oxygen, and Ar-O{sub 2} mixture plasmas are investigated using optical emission spectroscopy (OES) combined with an rf-compensated Langmuir probe measurement. In each gas discharge, the electron density and the electron temperature were obtained by using the probe. The electron temperature was also obtained by OES models and compared with that measured by the probe. The electron temperature was observed to decrease with increasing power and pressure and also observed to decrease with increasing Ar content. Argon metastable densities were calculated based on an optical transition model. In Ar-O{sub 2} discharges, the dissociation fraction of O{sub 2} molecules was estimated using optical emission actinometry. The dissociation fraction was observed to increase with increasing power and Ar content.
This paper presents a new design of ion sensitive probe (ISP) that enables collection of pure ion current for accurate measurement of the perpendicular ion temperature in magnetized plasmas. The new type of ISP resolves a longstanding issue widely observed in ISP type measurements, namely, that the current-voltage characteristic is smeared by an unexpected electron current in the standard ISP model. The new ISP is equipped with a fine scale metal mesh on the sensor entrance to prevent electrons from flowing to the sensor, a phenomenon considered to be caused by the space-charge effect. The new ISP successfully measured the ion temperature of electron cyclotron resonance plasmas.
Ultrahigh speed images of ExB discharges are collected during electrostatic probing of magnetized microdischarges. Two azimuthally separated floating micro-Langmuir probes inserted into an axisymmetric microscale magnetically confined plasma are used to characterize azimuthal drift waves. The images reveal features associated with probe intrusion, showing how the electrostatic probes may disrupt the otherwise coherent azimuthal waves. The resulting wave dispersion calculated from the probe signals is consistent with the disruptions seen in the images. These images demonstrate how probe measurements of fluctuations and turbulence, even when probe dimensions are much smaller than characteristic discharge scales, must be interpreted with caution.
In the NASA planetary program, atmospheric entry probe missions to Jupiter, Saturn, and Uranus are potential programs now being planned for the 1980's. The work reported in this paper is concerned with predicting the electron density, and resulting radiative emission from the shock layer which must be accommodated by the entry probe heatshield. Within the hydrogen-helium plasma surrounding the forward heatshield, there are regions of near thermochemical equilibrium whose properties are predictable - however, there are uncertainties in these electron density calculations necessitating further measurements by H-beta line broadening and holographic interferometer fringe shift as reported here. There is good agreement between the results obtained from the holographic measurements and the spectroscopic measurements which lends confidence to each of the two completely independent diagnostic techniques. The equilibrium electron density determined from the experimental measurements is somewhat higher than that predicted.
To characterize the temporal evolution of ultrashort X-ray pulses emitted by laser plasmas using a pump-probe method, a magnetic bottle time-of-flight electron spectrometer is constructed. The design is determined by numerical calculations of a mirror magnetic field and of the electron trajectory in a flight tube. The performance of the spectrometer is characterized by measuring the electron spectra of xenon atoms irradiated with a laser-driven plasma X-ray pulse. In addition, two-color above-threshold ionization (ATI) experiment is conducted for measurement of the X-ray laser pulse duration, in which xenon atoms are simultaneously irradiated with an X-ray laser pump and an IR laser probe. The correlation in the intensity of the sideband spectra of the 4d inner-shell photoelectrons and in the time delay of the two laser pulses yields an X-ray pulse width of 5.7 ps, in good agreement with the value obtained using an X-ray streak camera.
This paper derives a wave equation in magnetized plasma under electromagnetically induced transparency (EIT) regime for probe electron cyclotron wave. The equation has a solution indicating a state analogous to 'dark-state polaritons' [M. Fleischhauer and M. D. Lukin, Phys. Rev. Lett. 84, 5094 (2000)] in quantum atomic system. The state analogous to dark-state polaritons is a propagating coupled state of the probe-wave electric field and longitudinal plasma oscillation. The propagation of the coupled state can be stopped as its waveform is maintained if injection of pump wave is properly controlled in time domain. The 'stop-light' is achieved by adiabatic transition from a state in which the probe-wave field is dominant to a state in which the longitudinal plasma oscillation is dominant. This study also recaptures a phenomenon analogous to 'coherent population trap' in conventional EIT of quantum atomic system.
Triple probes have been used to measure plasma parameters of low temperature and edge plasmas, yielding simultaneous measurements of electron temperature, ion density, and floating potential. Unlike standard Langmuir and double probe techniques, there is no requirement to sweep the probe potential relative to the plasma, thus allowing fast time resolution. However, in some plasma systems 'ground' is not well defined with respect to a known ground, may vary strongly in time, or may be at an inconveniently high voltage. The resulting high plasma (or floating) potential requires common mode rejection before the signals can be digitized. A signal detection circuit constructed from inexpensive operational amplifiers and that makes use of a novel floating bias generation configuration is described.