Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Microscopic Understanding of the Effects of Impurities in Low RRR SRF Cavities

The SRF community has shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurities of niobium coupons with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of impurity-based improvements can be better understood and improved upon. The combination of RF testing, temperature mapping, frequency vs temperature analysis, and materials studies reveals a microscopic picture of why low RRR cavities experience low BCS resistance behavior more prominently than their high RRR counterparts. We evaluate how differences in the mean free path, grain structure, and impurity profile affect RF performance. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Evidence for Scission Neutrons

We discuss the neck rupture stage of fission and the emission of particles afterwards, two extremely rapid and highly non-equilibrium processes. Currently, the neck rupture cannot be directly probed by experiment, highlighting the importance of reliable theoretical predictions for this stage of fission. Time-dependent density functional theory (TDDFT) is used to simulate the spontaneous fission of 252 Cf. In conjunction with statistical models, inputs from microscopic calculations can be used to make predictions for prompt neutron and gamma emission spectra, quantities which can be experimentally measured. Here we characterize the scission mechanism within TDDFT and estimate the number of scission neutrons and their kinetic energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward a microscopic picture of hadronization and multi-parton processes

This project advanced the understanding of how quarks and gluons produced in high-energy collisions transform into the hadrons observed in particle detectors, a fundamental process known as quantum chromodynamics (QCD) hadronization. By combining theoretical calculations, quantum simulation methods, and modern AI techniques, the research developed new tools to study multi-parton dynamics and nonperturbative effects that are essential for interpreting data from current and future nuclear physics experiments. Key outcomes include new theoretical frameworks for jet and hadron measurements, pioneering quantum simulation algorithms for real-time dynamics in field theories, and the development of advanced machine-learning models, such as diffusion models and explainable classifiers, to simulate and analyze collider events. These results are directly relevant to experiments at Jefferson Lab, Brookhaven National Laboratory, and the future Electron-Ion Collider, and they also have a broader impact in areas such as quantum information science and data-driven modeling of complex systems. The project supported the training of graduate students and postdoctoral fellows and contributed to the broader scientific community through publications, workshops, and collaborative activities. Overall, this work provides new insights into the microscopic mechanisms of hadron formation and establishes a foundation for future studies at the intersection of nuclear physics, artificial intelligence, and quantum computing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Visualization of Cell-Cell Adhesion Complexes at Micro and Nanoscale

Considerable progress has been made in our knowledge of the morphological and functional varieties of anchoring junctions. Cell-cell adhesion contacts consist of discrete junctional structures responsible for the mechanical coupling of cytoskeletons and allow the transmission of mechanical signals across the cell collective. The three main adhesion complexes are adherens junctions, tight junctions, and desmosomes. Microscopy has played a fundamental role in understanding these adhesion complexes on different levels in both physiological and pathological conditions. In this review, we discuss the main light and electron microscopy techniques used to unravel the structure and composition of the three cell-cell contacts in epithelial and endothelial cells. It functions as a guide to pick the appropriate imaging technique(s) for the adhesion complexes of interest. We also point out the latest techniques that have emerged. At the end, we discuss the problems investigators encounter during their cell-cell adhesion research using microscopic techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Microscopic Structural and Dynamic Features in Triphilic Room Temperature Ionic Liquids

Here we report a thorough investigation of the microscopic and mesoscopic structural organization in a series of triphilic fluorinated room temperature ionic liquids, namely [1-alkyl,3-methylimidazolium][(trifluoromethanesulfonyl)(nonafluorobutylsulfonyl)imide], with alkyl=ethyl, butyl, octyl ([C n mim][IM 14 ], n = 2, 4, 8), based on the synergic exploitation of X-ray and Neutron Scattering and Molecular Dynamics simulations. This study reveals the strong complementarity between X-ray/neutron scattering in detecting the complex segregated morphology in these systems at mesoscopic spatial scales. The use of MD simulations delivering a very good agreement with experimental data allows us to gain a robust understanding of the segregated morphology. The structural scenario is completed with determination of dynamic properties accessing the diffusive behavior and a relaxation map is provided for [C 2 mim][IM 14 ] and [C 8 mim][IM 14 ], highlighting their natures as fragile glass formers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

General features of the stellar matter equation of state from microscopic theory, new maximum-mass constraints, and causality

The profile of a neutron star probes a very large range of densities, from the density of iron up to several times the density of saturated nuclear matter, and thus no theory of hadrons can be considered reliable if extended to those regions. We emphasize the importance of taking contemporary ab initio theories of nuclear and neutron matter as the baseline for any extension method, which will unavoidably involve some degree of phenomenology. We discuss how microscopic theory, on the one end, with causality and maximum-mass constraints, on the other, set strong boundaries to the high-density equation of state. We present our latest neutron star predictions where we combine polytropic extensions and parametrizations guided by speed of sound considerations. The predictions we show include our baseline neutron star cooling curves.

chiral effective field theory↗

Microscopic Characterization of Pb 10−x Cu x (PO 4 ) 6 O by 31 P and 63/65 Cu NMR Measurements

The report of the first room-temperature, ambient-pressure superconductivity in copper-doped lead apatite Pb 10−x Cu x (PO 4 ) 6 O has attracted lots of attention. However, subsequent studies revealed the presence of numerous impurity phases in the polycrystalline sample, and the sharp superconducting-like transition is not due to a superconducting transition but most likely due to a reduction in resistivity caused by the first-order structural phase transition of Cu 2 S at around 385 K from the β phase at high temperature to the γ phase at low temperature. Before now, only bulk measurements have been performed on a Pb 10−x Cu x (PO 4 ) 6 O powder sample, which could be affected by the impurity phases, masking the intrinsic properties of Pb 10−x Cu x (PO 4 ) 6 O. In this study, 31 P and 63/65 Cu nuclear magnetic resonance (NMR) measurements have been performed on a Pb 10−x Cu x (PO 4 ) 6 O powder sample to investigate its physical properties from a microscopic point of view. Our NMR data evidence the non-magnetic insulating nature of Pb 10−x Cu x (PO 4 ) 6 O without any trace of electron correlation effects. Furthermore, the 63/65 Cu NMR results suggest that no copper or very little copper is substituted for Pb in Pb 10 (PO 4 ) 6 O prepared by sintering Pb 2 SO 5 and Cu 3 P.

lead apatite↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Lepton–Nucleus Interactions within Microscopic Approaches

This review paper emphasizes the significance of microscopic calculations with quantified theoretical error estimates in studying lepton–nucleus interactions and their implications for electron scattering and accelerator neutrino oscillation measurements. We investigate two approaches: Green’s Function Monte Carlo and the extended factorization scheme, utilizing realistic nuclear target spectral functions. In our study, we include relativistic effects in Green’s Function Monte Carlo and validate the inclusive electron scattering cross section on carbon using available data. We compare the flux-folded cross sections for neutrino-carbon scattering with T2K and MINER$v$ A experiments, noting the substantial impact of relativistic effects in reducing the theoretical curve strength when compared to MINER$v$ A data. Additionally, we demonstrate that quantum Monte Carlo-based spectral functions accurately reproduce the quasi-elastic region in electron scattering data and T2K flux-folded cross sections. By comparing results from Green’s Function Monte Carlo and the spectral function approach, which share a similar initial target state description, we quantify errors associated with approximations in the factorization scheme and the relativistic treatment of kinematics in Green’s Function Monte Carlo.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope

Here, we demonstrate extension of electron-beam lithography using conventional resists and pattern transfer processes to single-digit nanometer dimensions by employing an aberration-corrected scanning transmission electron microscope as the exposure tool. Here, we present results of single-digit nanometer patterning of two widely used electron-beam resists: poly (methyl methacrylate) and hydrogen silsesquioxane. The method achieves sub-5 nanometer features in poly (methyl methacrylate) and sub-10 nanometer resolution in hydrogen silsesquioxane. High-fidelity transfer of these patterns into target materials of choice can be performed using metal lift-off, plasma etch, and resist infiltration with organometallics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diesel Particulate Filter Durability Performance Comparison Using Metals Doped B20 vs. Conventional Diesel Part II: Chemical and Microscopic Characterization of Aged DPFs

This project's objective was to generate experimental data to evaluate the impact of metals doped B20 on diesel particle filter (DPF) ash loading and performance compared to that of conventional petrodiesel. The effect of metals doped B20 vs. conventional diesel on a DPF was quantified in a laboratory controlled accelerated ash loading study. The ash loading was conducted on two DPFs - one using ULSD fuel and the other on B20 containing metals dopants equivalent to 4 ppm B100 total metals. Engine oil consumption and B20 metals levels were accelerated by a factor of 5, with DPFs loaded to 30 g/L of ash. Details of the ash loading experiment and on-engine DPF performance evaluations are presented in the companion paper (Part I). The DPFs were cleaned, and ash samples were taken from the cleaned material. X-ray Fluorescence (XRF), X-Ray Photoelectron Spectroscopy (XPS) and X-Ray Diffraction (XRD) were conducted on the ash samples. Core samples were taken from the cleaned DPF and were subjected to scanning electron microscope energy dispersive x-ray spectroscopy (SEM-EDS) and XRF analysis. A comparison of the data from the two DPFs is presented. The XRD and XPS analysis showed that the compounds present in the ash from the two DPFs were nearly identical, though differing in concentrations. CaSO4 was the biggest component of the ash from both DPFs. The metals doped B20 fuel resulted in ash with similar characteristics to that deposited by the lube oil and did not appear to have any deleterious physical effects on the DPF substrate (did not penetrate the substrate).

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Fission Dynamics with Microscopic Level Densities

We present a consistent framework for treating the energy and angularmomentum dependence of the shape evolution in the nuclear fission. It combines microscopically calculated level densities with the Metropolis-walk method, has no new parameters, and can elucidate the energy-dependent influence of pairing and shell effects on the dynamics of warm nuclei.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attachment converts microscope to point source autocollimator

A low-power microscope or telescope provides a simple means of autocollimation. This is done by fitting the instrument with a light source to permit alignment from a reflecting surface normal to the optic axis of the instrument.

Shlichta, P. J.↗

New electron microscope employs new video display technique

Video display system for a scanning electron microscope provides slow scanning rates, a self-generated color gradient technique, and allows leisurely viewing of several hours. It also enables the viewing of areas where selected energy regions contribute relatively few electrons, and the changing of specimen position and magnification without adjustments.

Brookshier, W. K.↗