Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Structure–function relationships for squid skin-inspired wearable thermoregulatory materials

Wearable thermoregulatory technologies have attracted widespread attention because of their potential for impacting individual physiological comfort and for reducing building energy consumption. Within this context, the study of materials and systems that can merge the advantageous characteristics of both active and passive operating modes has proven particularly attractive. Accordingly, our laboratory has drawn inspiration from the appearance-changing skin of Loliginidae (inshore squids) for the introduction of a unique class of dynamic thermoregulatory composite materials with outstanding figures of merit. Herein, we demonstrate a straightforward approach for experimentally controlling and computationally predicting the adaptive infrared properties of such bioinspired composites, thereby enabling the development and validation of robust structure–function relationships for the composites. Our findings may help unlock the potential of not only the described materials but also comparable systems for applications as varied as thermoregulatory wearables, food packaging, infrared camouflage, soft robotics, and biomedical sensing.

Liu, Panyiming (ORCID:0000000242223670)↗

Multiscale porous elastomer substrates for multifunctional on-skin electronics with passive-cooling capabilities

In addition to mechanical compliance, achieving the full potential of on-skin electronics needs the introduction of other features. For example, substantial progress has been achieved in creating biodegradable, self-healing, or breathable, on-skin electronics. However, the research of making on-skin electronics with passive-cooling capabilities, which can reduce energy consumption and improve user comfort, is still rare. Herein, we report the development of multifunctional on-skin electronics, which can passively cool human bodies without needing any energy consumption. This property is inherited from multiscale porous polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (SEBS) supporting substrates. The multiscale pores of SEBS substrates, with characteristic sizes ranging from around 0.2 to 7 µm, can effectively backscatter sunlight to minimize heat absorption but are too small to reflect human-body midinfrared radiation to retain heat dissipation, thereby delivering around 6 °C cooling effects under a solar intensity of 840 W∙m -2 . Other desired properties, rooted in multiscale porous SEBS substrates, include high breathability and outstanding waterproofing. The proof-of-concept bioelectronic devices include electrophysiological sensors, temperature sensors, hydration sensors, pressure sensors, and electrical stimulators, which are made via spray printing of silver nanowires on multiscale porous SEBS substrates. The devices show comparable electrical performances with conventional, rigid, nonporous ones. Also, their applications in cuffless blood pressure measurement, interactive virtual reality, and human–machine interface are demonstrated. Notably, the enabled on-skin devices are dissolvable in several organic solvents and can be recycled to reduce electronic waste and manufacturing cost. Such on-skin electronics can serve as the basis for future multifunctional smart textiles with passive-cooling functionalities.

42 ENGINEERING↗

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors↗

Corporate Delivery of a Global Smart Buildings Program

Buildings account for about 40 percent of the total energy consumption in the U.S. and emit approximately one third of greenhouse gas emissions. But they also offer tremendous potential for achieving significant greenhouse gas reductions with the right savings strategies. With an increasing amount of data from buildings and advanced computational and analytical abilities, buildings can be made “smart” to optimize energy consumption and occupant comfort. Smart buildings are often characterized as having a high degree of data and system integration, connectivity and control, as well as the advanced use of data analytics. These “smarts” can enable up to 10–20% savings in a building, and help ensure that they persist over time. In 2009, Microsoft Corporation launched the Energy-Smart Buildings (ESB) program with a vision to improve building operations services, security and accessibility in services, and new tenant applications and services that improve productivity and optimize energy use. The ESB program focused on fault diagnostics, advanced analytics and new organizational processes and practices to support their operational integration. In addition to the ESB program, Microsoft undertook capital improvement projects that made effective use of a utility incentive program and lab consolidations over the same duration. The ESB program began with a pilot at Microsoft's Puget Sound campus that identified significant savings of up to 6–10% in the 13 pilot buildings. The success of the pilot led to a global deployment of the program. Between 2009 and 2015, there was a 23.7% reduction in annual electricity consumption (kWh) at the Puget Sound campus with 18.5% of that resulting from the ESB and lab consolidations. This article provides the results of research conducted to assess the best-practice strategies that Microsoft implemented to achieve these savings, including the fault diagnostic routines that are the foundation of the ESB program and organizational change management practices. It also presents the process that was adopted to scale the ESB program globally. We conclude with recommendations for how these successes can be generalized and replicated by other corporate enterprises.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

Methodology and analytical approach to investigate the impact of building temperature setpoint schedules

This work presents a method for generating a large set of stochastically varying temperature setpoint schedules for building performance simulations. It analyses tradeoffs resulting from specific changes to those schedules in terms of three quantities: total electricity consumption per day; maximum hourly electricity consumption per day and predicted percentage dissatisfied (occupant thermal comfort). The method for generating schedules requires a single base schedule as the starting point and, using a few clearly defined parameters, transforms it into a set of schedules that can be used for modelling an existing building stock or for performing parametric studies. Temperature setpoint schedules are generated and simulated for a small office building in a cool-dry climate in three different case studies pertaining to changing temperature setpoint schedules. Tradeoffs between the three output metrics are significant and vary based on the temperature setpoint schedules and the time of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST↗

On-policy learning-based deep reinforcement learning assessment for building control efficiency and stability

Artificial intelligence technologies have emerged as a game changer not only in specific applications such as image recognition and machine translation but also in many scientific domains. In particular, as deep reinforcement learning (DRL) has shown great success in complex control problems, DRL-based control has been considered as a potential solution to efficiently control and manage building systems. However, broad assessment of DRL-based building control is still required to characterize their pros and cons in comparison with conventional building control methods (e.g., rule-based feedback controls). In this paper, we assessed DRL-based controls with on-policy learning-based algorithms and continuous control actions for cooling control of large office buildings in the summer season to minimize whole-building energy use and occupant discomfort. We compared DRL-based control methods with two baseline control methods: (1) a pre-determined schedule with supply temperature and static pressure setpoints, and (2) advanced reset method that adjusts setpoints based on heuristic rules, i.e., ASHRAE Guideline 36. We also tested the DRL algorithms to evaluate their performances in multiple climate locations. We found that DRL-based control methods outperformed the baseline control methods in terms of energy savings while maintaining a thermal comfort. DRL reduced energy use between ~4%–22% on average compared to the baseline methods, depending on climate location. We also evaluated DRL-based control in terms of control stability and showed that DRL-based methods should address the span of hardware lifetimes in practical operations.

control stability↗

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗

LARGE-SCALE FLUCTUATIONS IN THE He II Ly{alpha} FOREST AND He II REIONIZATION

We examine large-scale fluctuations in the He II Ly{alpha} forest transmission during and after He II reionization. We use a simple Monte Carlo model to distribute quasars throughout a large volume and compute the resulting radiation field along one-dimensional skewers. In agreement with previous studies, we find that the rarity of these sources induces order unity fluctuations in the mean optical depth after reionization, even when averaged over large segments ({approx}10-100Mpc across). We compare our models to existing data along five He II Ly{alpha} forest lines of sight spanning z {approx} 2-3.2. The large cosmic variance contained in our model plausibly explains many of the observed fluctuations at z {approx_lt} 2.5. But our models cannot accommodate the large fluctuations toward high optical depths on {approx}30Mpc scales observed at z {approx} 2.7-2.9, and the measured optical depths ({tau}{sub eff} {approx_gt} 4) at z>2.9 are difficult to explain with a smoothly evolving mean radiation field. In order to better understand these data, we construct a toy model of He II reionization, in which we assume that regions with the smallest radiation fields in a post-reionization universe (or farthest from strong ionizing sources) are completely dark during reionization. The observed fluctuations fit much more comfortably into this model, and we therefore argue that, according to present data, He II reionization does not complete until z {approx_lt} 2.9.

79 ASTRONOMY AND ASTROPHYSICS↗

ELECTRON-IMPACT EXCITATION OF Ni II: EFFECTIVE COLLISION STRENGTHS FOR OPTICALLY ALLOWED FINE-STRUCTURE TRANSITIONS

In this paper, we present collision strengths and Maxwellian averaged effective collision strengths for the electron-impact excitation of Ni II. Attention is expressly concentrated on the optically allowed fine-structure transitions between the 3d {sup 9}, 3d {sup 8}4s, and 3d {sup 7}4s {sup 2} even parity levels and the 3d {sup 8}4p and 3d {sup 7}4s 4p odd parity levels. The parallel RMATRXII R-matrix package has been recently extended to allow for the inclusion of relativistic fine-structure effects. This suite of codes has been utilized in conjunction with the parallel PSTGF and PSTGICF programs in order to compute converged total collision strengths for the allowed transitions with which this study is concerned. All 113 LS terms identified with the 3d {sup 9}, 3d {sup 8}4s, 3d {sup 7}4s {sup 2}, 3d {sup 8}4p, and 3d {sup 7}4s 4p basis configurations were included in the target wavefunction representation, giving rise to a sophisticated 295 jj-level, 1930 coupled channel scattering complex. Maxwellian averaged effective collision strengths have been computed at 30 individual electron temperatures ranging from 30 to 1,000,000 K. This range comfortably encompasses all temperatures significant to astrophysical and plasma applications. The convergence of the collision strengths is exhaustively investigated and comparisons are made with previous theoretical works, where significant discrepancies exist for the majority of transitions. We conclude that intrinsic in achieving converged collision strengths and thus effective collision strengths for the allowed transitions is the combined inclusion of contributions from the (N + 1) partial waves extending to a total angular momentum value of L = 50 and further contributions from even higher partial waves accomplished by employing a 'top-up' procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarimetry in the hard X-ray domain with INTEGRAL SPI

We present recent improvements in polarization analysis with the INTEGRAL SPI data. The SPI detector plane consists of 19 independent Ge crystals and can operate as a polarimeter. The anisotropy characteristics of Compton diffusions can provide information on the polarization parameters of the incident flux. By including the physics of the polarized Compton process in the instrument simulation, we are able to determine the instrument response for a linearly polarized emission at any position angle. We compare the observed data with the simulation sets by a minimum χ{sup 2} technique to determine the polarization parameters of the source (angle and fraction). We have tested our analysis procedure with Crab Nebula observations and find a position angle similar to those previously reported in the literature, with a comfortable significance. Since the instrument response depends on the incident angle, each exposure in the SPI data requires its own set of simulations, calculated for 18 polarization angles (from 0° to 170° in steps of 10°) and unpolarized emission. The analysis of a large number of observations for a given source, required to obtain statistically significant results, represents a large amount of computing time, but it is the only way to access this complementary information in the hard X-ray regime. Indeed, major scientific advances are expected from such studies since the observational results will help to discriminate between the different models proposed for the high energy emission of compact objects like X-ray binaries and active galactic nuclei or gamma-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMBINED VERY LARGE TELESCOPE AND GEMINI STUDY OF THE ATMOSPHERE OF THE DIRECTLY IMAGED PLANET, β PICTORIS b

We analyze new/archival VLT/NaCo and Gemini/NICI high-contrast imaging of the young, self-luminous planet β Pictoris b in seven near-to-mid IR photometric filters, using advanced image processing methods to achieve high signal-to-noise, high precision measurements. While β Pic b's near-IR colors mimic those of a standard, cloudy early-to-mid L dwarf, it is overluminous in the mid-infrared compared to the field L/T dwarf sequence. Few substellar/planet-mass objects—i.e., κ And b and 1RXJ 1609B—match β Pic b's JHK{sub s}L' photometry and its 3.1 μm and 5 μm photometry are particularly difficult to reproduce. Atmosphere models adopting cloud prescriptions and large (∼60 μm) dust grains fail to reproduce the β Pic b spectrum. However, models incorporating thick clouds similar to those found for HR 8799 bcde, but also with small (a few microns) modal particle sizes, yield fits consistent with the data within the uncertainties. Assuming solar abundance models, thick clouds, and small dust particles ((a) = 4 μm), we derive atmosphere parameters of log (g) = 3.8 ± 0.2 and T{sub eff} = 1575-1650 K, an inferred mass of 7{sup +4}{sub -3} M{sub J} , and a luminosity of log(L/L{sub ☉}) ∼–3.80 ± 0.02. The best-estimated planet radius, ≈1.65 ± 0.06 R{sub J} , is near the upper end of allowable planet radii for hot-start models given the host star's age and likely reflects challenges constructing accurate atmospheric models. Alternatively, these radii are comfortably consistent with hot-start model predictions if β Pic b is younger than ≈7 Myr, consistent with a late formation well after its host star's birth ∼12{sup +8}{sub -4} Myr ago.

79 ASTRONOMY AND ASTROPHYSICS↗

Theories of glass formation and glass transition

This key-issues review is a plea for a new focus on simpler and more realistic models of glass-forming fluids. It seems to me that we have too often been led astray by sophisticated mathematical models that beautifully capture some of the most intriguing features of glassy behavior, but are too unrealistic to provide bases for predictive theories. As illustrations of what I mean, the first part of this article is devoted to brief summaries of imaginative, sensible, but disparate and often contradictory ideas for solving glass problems. Almost all of these ideas remain alive today, with their own enthusiastic advocates. I then describe numerical simulations, mostly by H Tanaka and coworkers, in which it appears that very simple, polydisperse systems of hard disks and spheres develop long range, Ising-like, bond-orientational order as they approach glass transitions. Finally, a summary of my recent proposal that topologically ordered clusters of particles, in disordered environments, tend to become aligned with each other as if they were two-state systems, and thus produce the observed Ising-like behavior. Neither Tanaka’s results nor my proposed interpretation of them fit comfortably within any of the currently popular glass theories.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cosmic acceleration without dark energy: background tests and thermodynamic analysis

A cosmic scenario with gravitationally induced particle creation is proposed. In this model the Universe evolves from an early to a late time de Sitter era, with the recent accelerating phase driven only by the negative creation pressure associated with the cold dark matter component. The model can be interpreted as an attempt to reduce the so-called cosmic sector (dark matter plus dark energy) and relate the two cosmic accelerating phases (early and late time de Sitter expansions). A detailed thermodynamic analysis including possible quantum corrections is also carried out. For a very wide range of the free parameters, it is found that the model presents the expected behavior of an ordinary macroscopic system in the sense that it approaches thermodynamic equilibrium in the long run (i.e., as it nears the second de Sitter phase). Moreover, an upper bound is found for the Gibbons–Hawking temperature of the primordial de Sitter phase. Finally, when confronted with the recent observational data, the current 'quasi'-de Sitter era, as predicted by the model, is seen to pass very comfortably the cosmic background tests.

79 ASTRONOMY AND ASTROPHYSICS↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗