Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Use of LARS system for the quantitative determination of smoke plume lateral diffusion coefficients from ERTS images of Virginia

A technique for measuring smoke plume of large industrial sources observed by satellite using LARSYS is proposed. A Gaussian plume model is described, integrated in the vertical, and inverted to yield a form for the lateral diffusion coefficient, Ky. Given u, wind speed; y sub l, the horizontal distance of a line of constant brightness from the plume symmetry axis a distance x sub l, downstream from reference point at x=x sub 2, y=0, then K sub y = u ((y sub 1) to the 2nd power)/2 x sub 1 1n (x sub 2/x sub 1). The technique is applied to a plume from a power plant at Chester, Virginia, imaged August 31, 1973 by LANDSAT I. The plume bends slightly to the left 4.3 km from the source and estimates yield Ky of 28 sq m/sec near the source, and 19 sq m/sec beyond the bend. Maximum ground concentrations are estimated between 32 and 64 ug/cu m. Existing meteorological data would not explain such concentrations.

Blais, R. N.↗

Optimization of the deep neural network parameters for generating homogenized fuel assembly data for nodal codes

Homogenized fuel assembly (FA) data is a typical input data for nodal codes. Generating that data, however, could be time-consuming. One of promising ways to mitigate the computational burden of generating macroscopic cross-sections is to use trained artificial neural network (ANN) models for predicting nuclear data. However, there is a challenge to make the model support variable FA geometry. In this work, two most common types of FA were combined in one ANN model. Since there could be multiple ways of converting 2-dimensional FA data into 1-dimensional input vector for ANN, three different approaches of data flattening were evaluated. The input parameters included each fuel pin enrichment, fuel temperature, moderator temperature and boron concentration. The output parameters were 2-group macroscopic cross-sections (XS) and pin power distribution (HFF). A fully connected deep neural network (DNN) model was trained and tested using pre-generated data obtained with lattice physics code STREAM. The results of this study showed no statistically significant difference in the accuracy of XS and HFF generation for all 3 tested input vector orders. This means that fully connected DNN for XS generation demonstrated input sequence invariance. Results of comparing predicted XS data with reference solutions were found sufficiently close considering the reduction of computation time offered by ANN. Mean relative difference (MRD) for all output XS parameters was found below 0.7%, while HFF MRD was found higher compared to XS values, in some cases slightly exceeding 1%, mostly near guide tube locations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bench-Scale Development of a Hybrid Membrane-Absorption CO 2 Capture Process

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept Polaris TM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, lowpressure- drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

99 GENERAL AND MISCELLANEOUS↗

Product consistency test results for the LAW Phase 4 gases

In this report, the Savannah River National Laboratory provides chemical analysis of Product Consistency Test (PCT) leachates from a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory (PNNL). The series included quenched and canister-centerline cooled (CCC) versions of the glasses. The resulting data will be used in the development of enhanced property/composition models for waste vitrification at Hanford. For some of the glass leachates, minor scatter among the triplicate values of some analytes were observed. For other leachates, there were more significant differences among the triplicate values. A review of the PCT data noted that there was little difference between the normalized values based on targeted or measured glass composition. Several of the study glasses have normalized concentration of element “i” (NCi) values that are greater than the Hanford Tank Waste Treatment and Immobilization Plant immobilized low-activity waste constraint of 4 g/L for boron (B), sodium (Na), and silicon (Si). The results of these glasses will help ensure the ability of advanced glass performance models to appropriately predict acceptable compositions. For the study glasses with NCi values exceeding 4 g/L, the CCC heat treatment samples had generally lower NCi values than quenched samples. The samples of the Environmental Assessment (EA) reference glass included with each PCT set had generally consistent NCi values. The release rates for boron (B), potassium (K), lithium (Li), sodium (Na), and silicon (Si) were highly correlated for the study glasses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emergence of RNA and Early Life; Experimental Modeling and Geochemical Constraints

Support from this grant continues to fund our research on two related problems. One involves attempts to model the abiotic formation of simple source compounds for functional biomolecules, their concentration from dilute state in the hydrosphere and in several cases surface induced reactions to form precursor monomers for bioactive end products. The second area is a search for the earliest traces of life on Earth and the early environments on Earth and Mars. For this purpose we have analyzed the isotopic compositions of carbon and nitrogen in graphitic residues that have been thought to represent the remains of microorganisms. The results of these studies have been presented in a number of publication, listed as references.

Arrhenius, Gustaf↗

Effect of viral infection on the ice nucleation efficiency of marine coccolithophores

A marine coccolithophore (Emiliania huxleyi) and coccolithovirus (EhV-207) were grown together in a marine aerosol reference tank (MART) to investigate how the viral lysis of phytoplankton affects the formation of immersion mode ice nucleating particles (INPs) in sea spray aerosol (SSA). The mean ice nucleation temperatures of SSA produced during viral infection were slightly lower (–28.5 °C) than pre-viral infection (–27.5 °C). Ice nucleation temperatures were relatively low, indicating that organic matter from E. huxleyi is less effective as an INP than phytoplankton examined in previous studies. E. huxleyi is covered in calcium carbonate coccoliths and contains high intracellular concentrations of dimethylsulfoniopropionate (DMSP). The ice nucleation efficiencies of purified components were measured to better understand this model system. Purified coccoliths were moderately effective INPs (–25.3 ± 0.4 °C at 5 x 10 2 mg L -1 (mean ±pooled SD)) that showed a concentration effect, with lower freezing temperatures at lower concentrations. Coccoliths and DMSP were both weakly efficient INPs. In comparison, purified phytoplankton viruses (EhV-207 and CtenRNAV-01) infecting coccolithophores and diatoms, respectively, did not affect freezing at temperatures warmer than the procedural blank. Our results suggest that E. huxleyi, in contrast to diatoms and cyanobacteria, is not a significant source of immersion mode INPs to the marine atmosphere, despite its broad distribution in the global ocean and large-scale bloom formation.

59 BASIC BIOLOGICAL SCIENCES↗

Low-Cost Heliostat for High-Flux Small-Area Receivers (Final Technical Report)

This project analyzed a two-stage heliostat concept consisting of a tracking stage and a concentrating stage. The tracking stage uses mirrors mounted on a common drive that move to track the sun. The concentrating stage consists of stationary mirrors that each have a unique angle to direct rays towards a small-area, high-flux, point-focused receiver. By splitting the collection and concentrating process into two stages, multiple small, inexpensive mirrors can share a structure and be controlled by a single drive in the tracking stage. The project effort developed modeling techniques that were specifically relevant to this two-stage heliostat concept. Both field-level and unit-level models were developed. The field-level model does not explicitly consider unit-level losses which are predicted by the unit-level model and then integrated into the field-level model through a correlation referred to as an efficiency modifier. This approach is referred to as the two-model approach; the development and demonstration of this two-model approach for a multi-stage heliostat technology is a key outcome of this work. The field-level model is used to design a field that hits a specific design day power given a set of heliostat design parameters. An oversized field is simulated and then heliostat units are removed based on their annual energy production in order to generate the highest performing field. The field reduction procedure fits a smooth curve fit to annual energy production as a function of position in the field which has the effect of reducing the noise that is otherwise caused by the Monte Carlo ray tracing technique. This approach is referred to as the annual energy fit method and substantially reduces computational run time for a given field level modeling accuracy. The annual energy fit approach enables the selection of a properly sized, high-performing field using orders of magnitude fewer rays than would otherwise be possible and the development of this approach is a second key outcome of this work. These models are used within a genetic optimization algorithm in order to optimize the geometric parameters associated with a heliostat in order to achieve the lowest cost per unit of collected design day power. The cost modeling that underlies the optimization is a simple, scaling type analysis backed up by a much more detailed Design for Manufacture and Assembly (DFMA) analysis. Although the figure of merit used for optimization was not cost per mirror area, this metric is reasonable to use as a means of comparison. The optimally designed 500 kW design has a tracking mirror specific cost of $181.85/m 2 , which is significantly larger than the target value and also larger than the current state of the art. The cost of the torque-tube type linkages contributed substantially to the overall cost. Based on this observation, potentially attractive alternative design configuration utilizing a capstan type actuation system should be investigated. Finally, NREL compared the performance of the two-stage heliostat to the performance of a focused and different sized flat conventional heliostats and showed that, as expected, additional losses versus the convention heliostat caused by a worse cosine efficiency, two stages of reflection, and interstage interactions. The two-stage heliostat requires around 75% more reflective area than a flat 1x1 meter conventional heliostat (similar to a focused heliostat) and 40% more than a flat 2x2 meter conventional heliostat.

14 SOLAR ENERGY↗

Comparison of stratospheric ozone profiles and their seasonal variations as measured by lidar and Stratospheric Aerosol and Gas Experiment during 1988

A ground-based, high power, laser remote sensing system for measurements of stratospheric ozone concentration profiles has been in operation at the Jet Propulsion Laboratory Table Mountain Facility located in southern California, since January 1988. The seasonal variations observed in the ozone profiles, during 1988 and as a function of altitude, are described here. These profiles are compared with those from the Stratospheric Aerosol and Gas Experiment satellite instrument made within a radius of 1000 km from the lidar and also with the zonal mean measurements made in the band 34.4 +/- 5 deg. Comparison with the proposed new CIRA ozone reference model has also been carried out. The seasonal variations, between 25 and 50 km, observed by the two instruments and indicated by the reference model are in good agreement.

Mcdermid, I. Stuart↗

Determining CDOM Absorption Spectra in Diverse Aquatic Environments Using a Multiple Pathlength, Liquid Core Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.

Miller, Richard L.↗

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng↗

Linking soil phosphorus with forest litterfall resistance and resilience to cyclone disturbance: A pantropical meta-analysis

While tropical cyclone regimes are shifting with climate change, the mechanisms underpinning the resistance (ability to withstand disturbance-induced change) and resilience (capacity to return to pre-disturbance reference) of tropical forest litterfall to cyclones remain largely unexplored pantropically. Single-site studies in Australia and Hawaii suggest that litterfall on low-phosphorus (P) soils is more resistant and less resilient to cyclones. Here, we conducted a meta-analysis to investigate the pantropical importance of total soil P in mediating forest litterfall resistance and resilience to 22 tropical cyclones. We evaluated cyclone-induced and post-cyclone litterfall mass (g/m 2 /day), and P and nitrogen (N) fluxes (mg/m 2 /day) and concentrations (mg/g), all indicators of ecosystem function and essential for nutrient cycling. Across 73 case studies in Australia, Guadeloupe, Hawaii, Mexico, Puerto Rico, and Taiwan, total litterfall mass flux increased from ~2.5 ± 0.3 to 22.5 ± 3 g/m 2 /day due to cyclones, with large variation among studies. Litterfall P and N fluxes post-cyclone represented ~5% and 10% of the average annual fluxes, respectively. Post-cyclone leaf litterfall N and P concentrations were 21.6 ± 1.2% and 58.6 ± 2.3% higher than pre-cyclone means. Mixed-effects models determined that soil P negatively moderated the pantropical litterfall resistance to cyclones, with a 100 mg P/kg increase in soil P corresponding to a 32% to 38% decrease in resistance. Based on 33% of the resistance case studies, total litterfall mass flux reached pre-disturbance levels within one-year post-disturbance. A GAMM indicated that soil P, gale wind duration and time post-cyclone jointly moderate the short-term resilience of total litterfall, with the nature of the relationship between resilience and soil P contingent on time and wind duration. Across pantropical forests observed to date, our results indicate that litterfall resistance and resilience in the face of intensifying cyclones will be partially determined by total soil P.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of Biorelevant Pediatric Dissolution Methodology into PBPK Modeling to Predict In Vivo Performance and Bioequivalence of Generic Drugs in Pediatric Populations: a Carbamazepine Case Study

This study investigated the impact of gastro-intestinal fluid volume and bile salt (BS) concentration on the dissolution of carbamazepine (CBZ) immediate release (IR) 100 mg tablets and to integrate these in vitro biorelevant dissolution profiles into physiologically based pharmacokinetic modelling (PBPK) in pediatric and adult populations to determine the biopredictive dissolution profile. Dissolution profiles of CBZ IR tablets (100 mg) were generated in 50–900 mL biorelevant adult fasted state simulated gastric and intestinal fluid (Ad-FaSSGF and Ad-FaSSIF), also in three alternative compositions of biorelevant pediatric FaSSGF and FaSSIF medias at 200 mL. This study found that CBZ dissolution was poorly sensitive to changes in the composition of the biorelevant media, where dissimilar dissolution (F2 = 46.2) was only observed when the BS concentration was changed from 3000 to 89 μM (Ad-FaSSIF vs Ped-FaSSIF 50% 14 BS). PBPK modeling demonstrated the most predictive dissolution volume and media composition to forecast the PK was 500 mL of Ad-FaSSGF/Ad-FaSSIF media for adults and 200 mL Ped-FaSSGF/FaSSIF media for pediatrics. A virtual bioequivalence simulation was conducted by using Ad-FaSSGF and/or Ad-FaSSIF 500 mL or Ped-FaSSGF and/or Ped-FaSSIF 200 mL dissolution data for CBZ 100 mg (reference and generic test) IR product. The CBZ PBPK models showed bioequivalence of the product. This study demonstrates that the integration of biorelevant dissolution data can predict the PK profile of a poorly soluble drug in both populations. Further work using more pediatric drug products is needed to verify biorelevant dissolution data to predict the in vivo performance in pediatrics.

60 APPLIED LIFE SCIENCES↗

Historical and Future Extreme Event Indices for the Colorado River Basin

Extremes events are occurring more frequently and are projected to increase in the future. This data set includes extreme event indices that were generated for the Colorado River basin using data from the Variable Infiltration Capacity hydrologic model. VIC simulations were run using six CMIP5 earth system models (ESMs), two different time periods, (historical, 1970-1999) and future (2070-2099), and for one Representative Concentration Pathway (RCP 8.5). ESMs available are MPI-ESM-LR, MIROC-ESM, IPSL-CM5A-LR, GFDL-ESM2M, and GFDL-ESM2G. The different indicators include temperature (min/max, freezing days, heating days), precipitation (dry days, max), runoff (min, max), soil moisture (min, max), evapotranspiration (max), snow water equivalent (SWE, max), wind speeds (max), and pressure (min). Detailed information on the indicators, file names, and how they were calculated is included in the README.txt document. Data sets were used to calculate results are in related references Bennett et al. 2020 and Talsma et al. 2021. Details on the VIC model configuration is described in related references Bennett et al. 2018 and Bennett et al. 2017.

54 ENVIRONMENTAL SCIENCES↗

Bench scale development of a hybrid membrane-absorption CO 2 capture process (Final Report)

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept PolarisTM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, low-pressure-drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

20 FOSSIL-FUELED POWER PLANTS↗

New Absolute Cavity Pyrgeometer equation by application of Kirchhoff's law and adding a convection term

An equation for the Absolute Cavity Pyrgeometer (ACP) is derived from application of Kirchhoff's law and the addition of a convection term to account for the thermopile being open to the environment, unlike a domed radiometer. The equation is then used to investigate four methods to characterise key instrumental parameters using laboratory and field measurements. The first uses solar irradiance to estimate the thermopile responsivity, the second uses a minimisation method that solves for the thermopile responsivity and transmission of the cavity, and the third and fourth revisit the Reda et al. (2012) linear least squares calibration technique. Data were collected between January and November 2020, when the ACP96 and two IRIS radiometers monitoring terrestrial irradiances were available. The results indicate good agreement with IRIS irradiances using the new equation. The analysis also indicates that while the thermopile responsivity, concentrator transmission and emissivity of an ACP can be determined independently, as an open instrument, the impact of the convection term is minor in steady-state conditions but significant when the base of the instrument is being subjected to rapid artificial cooling or heating. Using laboratory characterisation of the transmission and emissivity, together with use of an estimated solar calibration of the thermopile, generated mean differences of less than 1.5 Wm -2 to the two IRIS radiometers. A minimisation method using each IRIS radiometer as the reference also provided similar results, and the derived thermopile responsivity was within 0.3 µV W -1 m 2 of the solar-calibration-derived infrared responsivity estimate of 10.5 µV W -1 m 2 estimated using a nominal solar calibration and provide irradiances within ±2 % of the terrestrial irradiance measured by the reference pyrgeometers traceable to the International System of Units (SI). The calibration method using linear least squares regression introduced by Reda et al. (2012) that relies on rapid cooling of the ACP base but utilising the new equation was found to produce consistent results but was dependent on the assumed temperature of the air above the thermopile. This study demonstrates the potential of the ACP as another independent reference radiometer for terrestrial irradiance once the magnitude of the convection coefficient and any potential variations in it have been resolved.

47 OTHER INSTRUMENTATION↗

Research Activities at Plasma Research Laboratory at NASA Ames Research Center

In order to meet NASA's requirements for the rapid development and validation of future generation electronic devices as well as associated materials and processes, enabling technologies are being developed at NASA-Ames Research Center using a multi-discipline approach. The first step is to understand the basic physics of the chemical reactions in the area of plasma reactors and processes. Low pressure glow discharges are indispensable in the fabrication of microelectronic circuits. These plasmas are used to deposit materials and also etch fine features in device fabrication. However, many plasma-based processes suffer from stability and reliability problems leading to a compromise in performance and a potentially increased cost for the semiconductor manufacturing industry. Although a great deal of laboratory-scale research has been performed on many of these processing plasmas, little is known about the gas-phase and surface chemical reactions that are critical in many etch and deposition processes, and how these reactions are influenced by the variation in operating conditions. Such a lack of understanding has hindered the development of process models that can aid in the scaling and improvement of plasma etch and deposition systems. Our present research involves the study of such plasmas. An inductively-coupled plasma (ICP) source in place of the standard upper electrode assembly of the Gaseous Electronics Conference (GEC) radio-frequency (RF) Reference Cell is used to investigate the discharge characteristics. This ICP source generates plasmas with higher electron densities and lower operating pressures than obtainable with the original parallel-plate version of the GEC Cell. This expanded operating regime is more relevant to new generations of industrial plasma systems being used by the microelectronics industry. The research goal is to develop an understanding of the physical phenomena involved in plasma processing and to measure much needed fundamental parameters, such as gas phase and surface reaction rates, species concentration, temperature, ion energy distribution, and electron number density.

Sharma, S. P.↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗