Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying neutron sources using recoil and time-of-flight spectroscopy

Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4⁢𝜎) at event counts as low as ∼10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.

neutron physics↗

Spin Texture Control and Magnetic Gap Engineering in a Ferromagnetic Insulator–Topological Insulator Sandwiched Heterostructure

Quantum materials that combine magnetism with topological order are emerging as key platforms for next-generation spintronics and low-energy electronics. They enable the realization of emergent quantum phenomena, such as the quantum anomalous Hall effect and axion insulator states. The ferromagnetic insulator (FMI)/topological insulator (TI)/FMI sandwich structure of a single-septuple layer (1SL) MnBi 2 Te 4 /four-quintuple layer (4QL) Bi 2 Te 3 /1SL MnBi 2 Te 4 holds great potential to achieve such desirable quantum phenomena at an elevated temperature, owing to its large Dirac point band gap and high Curie temperature. Here, for this work, spin- and angle-resolved photoemission spectroscopy (spin-ARPES) is employed to directly verify that the band gap arises from broken time-reversal symmetry via proximity-driven magnetization. This study demonstrates direct control of the spin state via external magnetic fields and unambiguously confirms the exchange interaction as the gap-opening mechanism. The robust magnetic gap and controllable spin texture make this heterostructure a suitable candidate for spintronic applications and magnetic topological quantum phases.

exchange gap↗

Completion document for MRT 8824 - Upgrade NIF’s gaseous radiochemistry diagnostics (RAGS) to support weapons science

This milestone highlights the successful upgrade and deployment of the Radiochemical Analysis of Gaseous Samples (RAGS) system, which delivers high-quality measurements (<20% uncertainty) of activated gaseous species from NIF implosions. These measurements are critical for supporting Stockpile Stewardship Program (SSP) relevant platforms, including LANL’s Double Shell and LLNL’s Pushered Single Shell campaigns. The RAGS diagnostic technique enables analysis of short-range mixing in implosions using high-Z shells, which are otherwise inaccessible to conventional x-ray diagnostic methods. By facilitating the investigation of high-Z material mixing into fusion burn, this system provides essential data for quantifying and interpreting results in high-energy density (HED) experiments. This report details the physics motivation, diagnostic fundamentals, planned and enacted upgrade work, and the quantification of uncertainty for the upgraded system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Deuterium retention in MeV ion-irradiated beryllium

Beryllium, as the material of choice for the ITER first wall, will be subject to high energy neutrons during the operation of the fusion device. Such irradiation will create displacement damage in the crystal lattice, which is known to influence hydrogen isotope retention, e.g. in iron and tungsten. Here in our study, we irradiated beryllium samples with high-energy oxygen ions up to various dpa levels (0.01 dpa, 0.1 dpa, and 1 dpa) and subsequently exposed the samples to deuterium plasma at 370 K and 573 K. The amount of retained deuterium was measured by thermal desorption spectroscopy and nuclear reaction analysis and was found to decrease by about 18% in the samples damaged up to 0.1 dpa compared to the undamaged ones. Further damaging up to 1 dpa did not show any additional effects on deuterium retention. Transmission electron microscopy was used to check for the existence of bubbles after plasma exposure.

36 MATERIALS SCIENCE↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material Identification Using Dual Energy X-ray Absorptiometry

Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a 1 , a 2 , a 3 } or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {$\frac{a_{2}}{a_{1}}$, $\frac{a_{3}}{a_{1}}$} or estimated effective atomic number $\hat{Z}$ from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable $\frac{a_{3}}{a_{1}}$ ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.

36 MATERIALS SCIENCE↗

The Steel Equivalency Workbook: An X-Ray Transmission Calculator

The Steel Equivalency Spreadsheet was created as a robust, user-friendly method for the following: 1. Determining if it is possible to image an object. 2. Reducing time needed when selecting equipment and preparing for field imaging activities. 3. Reducing the amount of equipment taken for field imaging activities. 4. Determining a starting point for exposure settings prior to imaging an object. 5. Reducing the amount of dose deposited to complete an imaging operation (in the spirit of As Low As Reasonably Achievable, ALARA). The spreadsheet was developed using various physical models to account for different phenomena. Future implementations aim to expand beyond the Digital Radiography and Computed Tomography Single Munition Scanner (DRCT SMS) in standard configuration to include high energy XRGs (Betatrons) and sub-MeV pulsed XRGs (XRS4). Alternative computational methods that compensate for incoherent scattering when calculating relative transmission are also being pursued. Ultimately the spreadsheet exceeded the developmental goal of having less than 10% average error when comparing calculations to real-world images.

36 MATERIALS SCIENCE↗

Phase I Final Report

Explore the source record for details and available documents.

36 MATERIALS SCIENCE↗

Diffusion of cesium in oxidized and unoxidized IG-110 nuclear graphite

Time-release diffusion measurements of cesium have been conducted over the temperature range 1073 K – 1973 K on oxidized and unoxidized IG-110 graphite. Four cesium concentrations were tested to investigate the concentration dependence of the diffusion coefficient. Two levels of oxidation were tested and compared to unoxidized concentration-matched sets to explore the effects of graphite oxidation. Here, the results demonstrate that cesium diffusion coefficient in unoxidized IG-110 graphite is independent of concentration within the range 34 – 163 µg Cs/g graphite . Above this, the effective cesium diffusion coefficient changes with concentration. The diffusion coefficient was increased by a factor of 2–12 in the oxidized set with 7.8% mass loss. These results can be used to aid predictive modeling of cesium diffusion in HTGR cores.

36 MATERIALS SCIENCE↗

The Mu2e Crystal and SiPM Calorimeter: Construction Status

The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with an energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large-area UV-extended silicon photomultipliers (SiPMs). It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this article, we present the status of construction and the quality control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Europium diffusion in IG-110 nuclear graphite

Europium diffusion in graphite has been recognized to be of interest in high-temperature gas reactor safety analysis, particularly as an indicator of strontium diffusion. However, no measurements of europium diffusion coefficients have been reported in the literature. In this work, the effective diffusion coefficient of europium was measured using a time-release method. Natural europium was loaded into pre-milled unirradiated IG-110 graphite spheres using a pressurized acid digestion vessel. The time-release experiments were performed in the temperature range 1823 K – 1973 K using a SiC diffusion cell connected to an inductively-coupled plasma mass spectrometer (ICP-MS) via a He gas line. Finally, the results of this work are: D Eu, IG-110 = (1.5 x 10 -3 m 2 /s) exp $(\frac{-2.87\mathrm{x}10^{5} J/mol}{RT})$ This effective diffusion coefficient can be used to aid in predictive modelling of europium transport in HTGRs.

36 MATERIALS SCIENCE↗

Scanning transmission x-ray microscopy (STXM) of plutonium oxide

Scanning transmission x-ray microscopy was used to examine plutonium oxide particles formed by the corrosion of δ-phase plutonium alloy under high-humidity conditions. O K-edge spectra collected from eight distinct particles displayed significant spectral differences, revealing heterogeneity in oxidation states within a single sample batch. Here, this variation suggests complex chemical environments and formation histories, which are important considerations for nuclear forensic investigations. These findings highlight both the potential of synchrotron-based x-ray microscopy for nondestructive, high-resolution analysis of nuclear materials and the need for expanded reference datasets to improve the interpretation and forensic utility of such measurements.

organic↗

Measurement of Helium and Xenon Knudsen permeability in graphite IG-11

Here, understanding the flow and diffusion (transport) of gases through nuclear graphite is of interest in both the prismatic and pebble bed high-temperature gas reactors (HTGRs), for normal operation and under accident conditions, for example, as related to graphite oxidation. Both the laminar and turbulent gaseous transport are of interest. It has also been noted that nuclear graphite can have pore sizes that can possibly lead to non-continuum transport, as the pore size can be comparable to the gaseous mean free path. We report measurements and analyzes of experiments performed with IG-11 graphite in the pressure range of 10 Pa to 14,700 Pa, 293 K, using Helium, and research grade xenon (99.999%), respectively. These values are in fair agreement with those reported for different graphites and gases by other investigators, but are also higher by six orders of magnitude than those reported for Kr permeability in a developmental very low permeability graphite-HXT-90. Our measured ratio of the Helium and Xenon permeabilities is about 4, different from $\sqrt{\frac{m_{Xe}}{m_{He}}}$ ≈ 5.72 that corresponds to diffuse reflection at the graphite surface for both gases. Simple analysis indicates that the two gases have slightly different accommodation coefficients (about 25%) with the graphite surface. However, there could also be other reasons, such as experimental uncertainties or the need for a more detailed analysis.

36 MATERIALS SCIENCE↗

Evolution of Microstructure and Surface Characteristics of FeCrAl alloys when Subjected to Flow Boiling Testing

FeCrAl alloys are candidate materials for manufacturing accident-tolerant fuel (ATF) cladding intended for light water reactors to increase fuel reliability and safety during design-basis and beyond-design-basis accident scenarios. The evolution of the materials' surface characteristics, microstructure, and mechanical properties when exposed to the Critical Heat Flux (CHF) in flow boiling testing is crucial for safety analysis while providing insights into their thermal-hydraulic performance in nuclear reactors. After CHF, the surface chemistry of two FeCrAl alloys, APMT and C26M, was studied to understand their evolution at the early stage of high-temperature excursions in short time periods. The results indicated a thin layer composed of oxides and hydroxides of Al, Cr, and Fe with varying proportions at different depths in the layer, as indicated by X-ray photoelectron spectroscopy (XPS) and depth profiling. The cross-sections prepared by focused ion beam (FIB) revealed the growth of an oxide layer, in the range of 90-180 nm thick, on the alloys' surfaces. The evolution of the materials' surface chemistry also led to a noticeable post CHF excursion increase in their wettability, with a slight increase in roughness. Further, the investigation of the materials' mechanical properties indicated a modest increase in hardness by 10-15% as well as an increase in their yield strength, as evidenced by the microindentation and ring compression tests conducted before and after CHF testing. Scanning electron Microscopy (SEM) and X-ray diffraction (XRD) were used to investigate microstructural features of the materials and their changes after CHF treatment.

36 MATERIALS SCIENCE↗

Mechanistic transition of stainless steel 304L corrosion in MgCl 2 phase change material under thermal cycling

Magnesium chloride (MgCl 2 )-based molten salt phase change materials (PCMs) are promising candidates for thermal energy storage (TES) owing to their advantageous thermophysical properties, however, their high corrosivity in the molten state limits material compatibility. In this study, the corrosion behavior of 304?L stainless steel (SS304L) exposed to MgCl2 PCM was investigated as a function of thermal cycling (up to 9000 cycles) relevant to PCM-based TES systems. Microstructural changes and elemental redistribution at the alloy-salt interface under thermal cycling conditions were characterized using synchrotron-based X-ray fluorescence (XRF) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS). Results show that corrosion is governed by selective Cr-dissolution and elemental diffusion near the interface and grain boundaries. A clear transition in the dominant corrosion mechanism is observed with increasing thermal cycles. Surface corrosion is the dominant mechanism up to 1000 cycles, whereas intergranular corrosion becomes the primary degradation mode beyond 2000 cycles. These mechanistic changes are interpreted in terms of evolving interfacial chemistry, microstructure and the diffusion-driven redistribution of alloying elements.

36 MATERIALS SCIENCE↗