DOE OSTI · 1977375
Europium diffusion in IG-110 nuclear graphite
Abstract
Europium diffusion in graphite has been recognized to be of interest in high-temperature gas reactor safety analysis, particularly as an indicator of strontium diffusion. However, no measurements of europium diffusion coefficients have been reported in the literature. In this work, the effective diffusion coefficient of europium was measured using a time-release method. Natural europium was loaded into pre-milled unirradiated IG-110 graphite spheres using a pressurized acid digestion vessel. The time-release experiments were performed in the temperature range 1823 K – 1973 K using a SiC diffusion cell connected to an inductively-coupled plasma mass spectrometer (ICP-MS) via a He gas line. Finally, the results of this work are: D Eu, IG-110 = (1.5 x 10 -3 m 2 /s) exp $(\frac{-2.87\mathrm{x}10^{5} J/mol}{RT})$ This effective diffusion coefficient can be used to aid in predictive modelling of europium transport in HTGRs.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Weilert, Taylor M., Walton, Kyle L., Loyalka, Sudarshan K., Brockman, John Douglas. 2022-01-17. Europium diffusion in IG-110 nuclear graphite. https://doi.org/10.1016/j.jnucmat.2022.153544
Cite the original work for its findings. Save a collection to share your selection of sources.