Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Bonded Interfaces for High-Temperature Power Electronics

Wide-bandgap devices have pushed the operational limit of semiconductor devices in automotive power electronics packages to higher temperatures (>200 degrees C). While a higher efficiency can be achieved through the use of wide-bandgap devices, the entire package must be re-designed with components that can withstand the higher temperature limits. Sintered silver and transient liquid phase bonds are potential candidates as bonded materials for use in higher temperatures however, the underlying mechanics of deformation under thermal loads and the resulting failure mechanisms in these materials are not well understood. Furthermore, thermomechanical modeling plays a key role in understanding the degradation behavior of bonded interface materials and for design optimization of power electronics packages.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Overview of Light Weight Radioisotope Heater Unit (LWRHU) User’s Guide

Idaho National Laboratory (INL) has recently compiled a user’s guide for the Light Weight Radioisotope Heater Unit (LWRHU). This guide gives an overview of the LWRHU to potential users. Information and data on mass properties, dimensions, thermal loads, and interfaces are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Overview of Light Weight Radioisotope Heating Unit (LWRHU) User’s Guide

Idaho National Laboratory (INL) has recently compiled a user’s guide for the LightWeight Radioisotope Heating Unit (LWRHU). This guide gives an overview of the LWRHU to potential users. Information and data on mass properties, dimensions, thermal loads, and interfaces are discussed.

42 ENGINEERING↗

Direct Numerical Simulation of Flame-Wall Interaction for Low-Carbon Gas Turbine Combustion

Green hydrogen (H2) and ammonia (NH3) are emerging as carbon free alternatives to hydrocarbon fuels. In gas turbines, flames interact with the combustor liner (wall), which affects the pollutant emissions, the burning efficiency, and the thermal load on the liner. We lack understanding of this important flame-wall interaction (FWI) for alternative fuels. FWI occurs at the scale of the flame thickness, and such scales are only resolved by direct numerical simulation. Here, we resolve the FWI for NH3 and H2 flames. Preliminary results of two distinct projects are presented: 2D laminar anchored V-flame, and 3D turbulent swirling flame. For the laminar flame, we show flame quenching at the wall and resulting leakage of NH3 and increased N2O, but decreased NO emissions. For the swirling flame, we show CO emissions, and comparison of flame shapes and location to experimental measurements. Ultimately we show that quenching and pollutant emissions strongly affected by fuel/air ratio, and that an inclined wall can stabilize very lean turbulent CH4/H2 flames, but prone to large CO emissions.

adaptive mesh refinement↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Resolution requirements for high-speed droplet impact along a rigid wall

The mechanical and thermal loads that are produced on high-speed projectiles from a droplet are key in the projectile development.To accurately predict the pressure produced along the wall surface during impact, it is important to correctly model the air/water interface of the droplet. Novel modeling approaches such as the Phase-Field enable control of the (numerical) interface thickness. However, the interplay between the grid resolution (including potential adaptive mesh refinement) and the interface thickness is unclear. In this work, the resolution requirements for numerical simulations of a two-dimensional cylindrical water droplet impacting a rigid wall at Mach four are computationally investigated. Numerical simulations are performed using a second-order accurate scheme with adaptive mesh refinement and a Phase-Field interface model. The choice of numerical interface thickness and resolution parameters affects the maximum pressure and location of the maximum pressure along the wall. The overall maximum pressure does not converge even at high resolutions. The number of levels and thickness (number of cells across the interface) play a role in obtaining a well behaved solution.

Burrell, E.↗

Coupling Microstructural Evolution Simulations to Material Property Degradation Predictions for Plasma-Facing Materials

Reliable material performance is required for plasma-facing material (PFM) candidates. Previous research has shown that plasma and neutron radiation exposure induces microstructural changes in PFMs; changes in thermal and electrical conductivities and in material hardening and embrittlement were also observed after neutron irradiation. These material property changes will negatively impact the performance of the PFMs in a fusion reactor. Despite the well-known connection between material microstructure, properties, and performance, there is a need for validated modeling capabilities connecting PFM property degradation with microstructural evolution under fusion-relevant conditions. We are developing a simulation capability to couple plasma-induced microstructural evolution to material property degradation. Our approach relies on deliberate mapping between individual simulation models and experimental characterization for validation. The open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) software was used for this simulation capability development. A MOOSE phase-field model was coupled with the cluster dynamics code, Xolotl, to predict microstructural evolution. Microstructure characterization techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), and laser scanning confocal microscopy (LSCM) are used to validate these microstructural evolution simulations. Calculation of thermal and electrical conductivities with first principles simulations was performed for bulk material and for grain boundaries; these results are used within MOOSE models to calculate effective thermal and electrical conductivities as a function of grain characteristics. Thermoreflectance and four-probe techniques were employed to measure the thermal and electrical conductivities, respectively. A MOOSE crystal plasticity model was adapted to predict microstructure-sensitive deformation behavior, and X-ray diffraction (XRD) was used to collect bulk dislocation density data for validation. After individual simulation validation, these models are coupled to predict material property changes resulting from plasma exposure. We focused here on an experimental design to emphasize the separate effects of moderate thermal loads and plasma exposure using tungsten. Annealing of tungsten was performed under a protective environment for temperatures ranging from 500 C to 1500 C. The plasma exposure was completed in the Tritium Plasma Experiment at Idaho National Laboratory under a deuterium flux of 1e22 D/m^2-s. This incremental approach is employed to build confidence in the modeling capability: separate-effects tests ensure that the models capture key mechanisms from single environmental conditions before predicting PFM property degradation under combined loads. We will show our early results from coupling these simulation models to predict PFM property changes from microstructural evolution. Comparisons of the simulation results with preliminary validation data will be discussed.

36 - MATERIALS SCIENCE↗

Connect microstructure evolution to property degradation with validated simulation

Reliable material performance is required for plasma-facing material (PFM) candidates. Previous research has shown that plasma and neutron radiation exposure induces microstructural changes in PFMs; changes in thermal and electrical conductivities and in material hardening and embrittlement were also observed after neutron irradiation. These material property changes will negatively impact the performance of the PFMs in a fusion reactor. Despite the well-known connection between material microstructure, properties, and performance, there is a need for validated modeling capabilities connecting PFM property degradation with microstructural evolution under fusion-relevant conditions. We are developing a simulation capability to couple plasma-induced microstructural evolution to material property degradation. Our approach relies on deliberate mapping between individual simulation models and experimental characterization for validation. The open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) software was used for this simulation capability development. A MOOSE phase-field model was coupled with the cluster dynamics code, Xolotl, to predict microstructural evolution. Microstructure characterization techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), and laser scanning confocal microscopy (LSCM) are used to validate these microstructural evolution simulations. Calculation of thermal and electrical conductivities with first principles simulations was performed for bulk material and for grain boundaries; these results are used within MOOSE models to calculate effective thermal and electrical conductivities as a function of grain characteristics. Thermoreflectance and four-probe techniques were employed to measure the thermal and electrical conductivities, respectively. A MOOSE crystal plasticity model was adapted to predict microstructure-sensitive deformation behavior, and X-ray diffraction (XRD) was used to collect bulk dislocation density data for validation. After individual simulation validation, these models are coupled to predict material property changes resulting from plasma exposure. We focused here on an experimental design to emphasize the separate effects of moderate thermal loads and plasma exposure using tungsten. Annealing of tungsten was performed under a protective environment for temperatures ranging from 500$^o$C to 1500$^o$C. The plasma exposure was completed in the Tritium Plasma Experiment at Idaho National Laboratory under a deuterium flux of 1e22 $\frac{D}{m^2s}$. This incremental approach is employed to build confidence in the modeling capability: separate-effects tests ensure that the models capture key mechanisms from single environmental conditions before predicting PFM property degradation under combined loads. We will show our early results from coupling these simulation models to predict PFM property changes from microstructural evolution. Comparisons of the simulation results with preliminary validation data will be discussed.

36 - MATERIALS SCIENCE↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Microcracking in composite laminates under thermal and mechanical loading

Composites used in space structures are exposed to both extremes in temperature and applied mechanical loads. Cracks in the matrix form, changing the laminate thermoelastic properties. The goal of the present investigation is to develop a predictive methodology to quantify microcracking in general composite laminates under both thermal and mechanical loading. This objective is successfully met through a combination of analytical modeling and experimental investigation. In the analysis, the stress and displacement distributions in the vicinity of a crack are determined using a shear lag model. These are incorporated into an energy based cracking criterion to determine the favorability of crack formation. A progressive damage algorithm allows the inclusion of material softening effects and temperature-dependent material properties. The analysis is implemented by a computer code which gives predicted crack density and degraded laminate properties as functions of any thermomechanical load history. Extensive experimentation provides verification of the analysis. AS4/3501-6 graphite/epoxy laminates are manufactured with three different layups to investigate ply thickness and orientation effects. Thermal specimens are cooled to progressively lower temperatures down to -184 C. After conditioning the specimens to each temperature, cracks are counted on their edges using optical microscopy and in their interiors by sanding to incremental depths. Tensile coupons are loaded monotonically to progressively higher loads until failure. Cracks are counted on the coupon edges after each loading. A data fit to all available results provides input parameters for the analysis and shows them to be material properties, independent of geometry and loading. Correlation between experiment and analysis is generally very good under both thermal and mechanical loading, showing the methodology to be a powerful, unified tool. Delayed crack initiation observed in a few cases is attributed to a lack of preexisting flaws assumed by the analysis. Some interactions between adjacent ply groups are attributed to local stress concentrations. These two effects are not captured by the analysis due to its global nature. The analysis is conservative in these cases and agrees well with data after the observed onset of cracking.

Maddocks, Jason R.↗

Effects of Tangential Edge Constraints on the Postbuckling Behavior of Flat and Curved Panels Subjected to Thermal and Mechanical Loads

A parametric study of the effects of tangential edge constraints on the postbuckling response of flat and shallow curved panels subjected to thermal and mechanical loads is presented. The mechanical loads investigated are uniform compressive edge loads and transverse lateral pressure. The temperature fields considered are associated with spatially nonuniform heating over the panels, and a linear through-the-thickness temperature gradient. The structural model is based on a higher-order transverse-shear-deformation theory of shallow shells that incorporates the effects of geometric nonlinearities, initial geometric imperfections, and tangential edge motion constraints. Results are presented for three-layer sandwich panels made from transversely isotropic materials. Simply supported panels are considered in which the tangential motion of the unloaded edges is either unrestrained, partially restrained, or fully restrained. These results focus on the effects of the tangential edge restraint on the postbuckling response. The results of this study indicate that tangentially restraining the edges of a curved panel can make the panel insensitive to initial geometric imperfections in some cases.

Lin, W.↗

The thermal structure, dust loading, and meridional transport in the Martian atmosphere during late southern summer

We have derived a comprehensive picture of the thermal structure and dust loading of the Martian atmosphere in a relatively clear period during late southern summer. Using a new technique for the simultaneous retrieval of atmospheric temperatures and airborne dust abundances, we examined a subset of the Mariner 9 infrared interferometer spectrometer (IRIS) thermal emission spectra spanning L sub s = 343 degrees to 348 degrees. Global maps of temperature and dust optical depth as functions of latitude (plus or minus 90 degrees), altitude (approx. 0-60 km), and Mars local time of day were constructed from the profiles from individual spectra. One of the principal conclusions from this work is that both dayside and nightside atmospheric temperatures at altitudes above about 40 km are warmer over the winter (north) polar regions than over the equator or the summer (south) polar regions. These anomalous temperatures are consistent with ground-based observations of polar warming at higher altitudes (50-85 km), and they indicate that the atmosphere is not in radiative equilibrium. Zonal-mean zonal winds are derived from the observed meridional gradients of the zonally averaged temperatures assuming geostrophy and zero surface zonal wind. The intense eastward jets (with velocities exceeding 120 m/s) correspond to regions of strong horizontal temperature gradients. Similar calculations have been reported previously, but they were not global in coverage. Both the zonal-mean meridional circulation and large-scale waves contribute to the north-south atmospheric transport.

Santee, M.↗

Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads

The design allows for the low-stress mounting of fragile objects, like thin walled glass, by using particular ways of compensating, isolating, or releasing the coefficient of thermal expansion (CTE) differences between the mounted object and the mount itself. This mount profile is lower than true full kinematic mounting. Also, this approach enables accurate positioning of the component for electrical and optical interfaces. It avoids the higher and unpredictable stress issues that often result from potting the object. The mount has been built and tested to space-flight specifications, and has been used for fiber-optic, optical, and electrical interfaces for a spaceflight mission. This mount design is often metal and is slightly larger than the object to be mounted. The objects are optical or optical/electrical, and optical and/or electrical interfaces are required from the top and bottom. This requires the mount to be open at both ends, and for the object s position to be controlled. Thin inside inserts at the top and bottom contact the housing at defined lips, or edges, and hold the fragile object in the mount. The inserts can be customized to mimic the outer surface of the object, which further reduces stress. The inserts have the opposite CTE of the housing material, partially compensating for the CTE difference that causes thermal stress. A spring washer is inserted at one end to compensate for more CTE difference and to hold the object against the location edge of the mount for any optical position requirements. The spring also ensures that any fiber-optic or optic interface, which often requires some pressure to ensure a good interface, does not overstress the fragile object. The insert thickness, material, and spring washer size can be traded against each other to optimize the mount and stresses for various thermal and vibration load ranges and other mounting requirements. The alternate design uses two separate, unique features to reduce stress and hold the object. A release agent is applied to the inside surface of the mount just before the binding potting material is injected in the mount. This prevents the potting material from bonding to the mount, and thus prevents stress from being applied, at very low temperatures, to the fragile object being mounted. The potting material mixing and curing is temperature- and humidity-controlled. The mount has radial grooves cut in it that the potting material fills, thus controlling the vertical position of the mounted object. The design can easily be used for long and thin objects, short and wide objects, and any shape in between. The design s advantages are amplified for long and thin fragile objects. The general testing range was 45 to +45 C, but multiple mounts were successfully tested down to 60 and up to 50 C and the design can be adjusted for larger ranges.

Amato, Michael↗

Mechanics of Preloaded Bolt Tensile Loading With Focus on Load Introduction Factor

The bolt tensile and joint separation loads are directly influenced by the locations at which the external loads enter the clamped members of a preloaded bolted joint (PBJ) and the associated load-paths through the joint. This physical load introduction mechanism affecting the bolt tensile loading is typically represented in the bolt tensile load equation, in part, by a load introduction factor (LIF), which was shown by H.M. Lee of Marshall Spaceflight Center to be a natural product of the bolt tensile load equation using a linear spring stiffness model. This LIF, being a function of load-path stiffness, has subsequently been denoted as the stiffness-based LIF (SBLIF), providing a framework to calculate the LIF using whatever load-path stiffness approximations are appropriate. Expanding upon the work of Lee, it is shown that the SBLIF and the joint stiffness factor are functions of the stiffnesses of the same load-paths and regions within a PBJ, and thus they should not be treated as independent variables. Mathematical expressions for the SBLIF are presented. Comparisons are shown between the analytically calculated SBLIF, the analytically calculated geometric LIF (GLIF), which is a simple clamped-member thickness ratio, the experimentally derived LIF, and the LIF determined by finite element analysis (FEA). Using experiment and FEA as a benchmark, the SBLIF, using traditional load-path stiffness approximations, enables a more accurate prediction of bolt tensile loading than the GLIF, although it can be unconservative near joint separation. The GLIF generally attributes more of the externally applied tensile load to the bolt than does the SBLIF, potentially resulting in heavier and/or more costly bolted joints. Mathematical relationships between the SBLIF and the GLIF are developed. Supplemental material is provided in the appendixes where the historical practice of using the joint compressive stiffness in place of the joint tensile stiffness is evaluated. The appendixes include step-by-step examples demonstrating the calculation of the SBLIF using traditional stiffness approximations and conclude with the development of the joint diagram in terms of the SBLIF, culminating into formulas for the key features of a joint diagram, which is useful for programming.

Load Path↗