Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Determination of the hydrogen heat of transport in Zircaloy-4

During operation in a nuclear reactor, Zr-based nuclear fuel cladding is subject to waterside corrosion which can lead to hydrogen ingress. Here, the hydrogen that enters the material will migrate to colder spots and precipitate as zirconium hydrides if the hydrogen content exceeds the hydrogen terminal solid solubility in the material. Since a temperature gradient is established in the radial direction of the cladding during operation, the hydrides can preferentially precipitate at the colder outer surface of the cladding. Other gradients can also occur in the longitudinal and azimuthal directions of the cladding tube. As a consequence, hydrogen redistributes itself in response to the concentration and temperature gradients present in the sample. The response of the hydrogen in solid solution to temperature gradients is governed by the heat of transport Q* as a function of temperature, so it can be used in the BISON code. A set of experiments was set up to determine the heat of transport (Q*), in which a uniformly hydrided Zircaloy-4 sample is annealed under a fixed temperature gradient at a range of temperatures, and the resulting hydrogen distribution is analyzed to determine Q*. The results are discussed in terms of existing literature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerating ion transport by dynamic asymmetry of alternating polymer electrolytes

Polymer based electrolytes allow the absence of volatile components in batteries thus increasing their safety. Yet, they exhibit drawbacks based on their low conductivity. We have used an alternating polymer consisting of dimethyl siloxane (DMS) and ethylene glycol (EG) blocks to circumvent known disadvantages of the usually used polyethylene glycol (PEG). Incorporating dimethyl siloxane lowers the glass-transition temperature and thus reduces the segmental relaxation time, by dynamic asymmetry or internal plasticization of the constituting polymer blocks. The alternating structure ensures miscibility of the different components and hinders crystallization. Furthermore, the pure polymer, P(DMS 3 -alt-EG 4 ), shows a segmental relaxation time well in the range needed for polymer electrolytes. Mixtures of LiClO 4 and P(DMS 3 -alt-EG 4 ) show a drastically reduced temperature dependence of their DC conductivity in comparison to PEG based systems, resulting in an increase by two orders of magnitude at T = 5 °C and even three to four orders of magnitude at T = 0 °C. Addition of coordinating (acetonitrile) or non-coordinating (toluene) solvent increases conductivity either via additional plasticization or by weakening the Li-binding yet looking at the dynamics at low concentrations of additional solvent the mobility of the polymer is reduced. In conclusion, the solvent addition leads only at higher solvent concentration to a reduction in relaxation time.

Jakobi, Bruno [Louisiana State Univ., Baton Rouge,↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining Erosion Rates and Landscape Evolution With In Situ 10 Be and 26 Al Cosmogenic Nuclides at Table Mountain, Antarctica

Abstract This study investigates surface weathering and sediment preservation at Table Mountain, a high‐elevation, hyperarid, polar landscape in the Transantarctic Mountains. We report cosmogenic nuclide concentrations ( 10 Be and 26 Al) in quartz from bedrock surfaces, erratic boulder lag, and cobbles embedded within Sirius Group sediments to quantify erosion rates. In situ 10 Be and 26 Al depth profiles from a 2.95 m permafrost core in the Sirius Group further constrain surface erosion rates and elucidate landscape stability. Measured 10 Be and 26 Al concentrations from two sandstone bedrock surfaces adjacent to Sirius Group sediments give erosion rates of 0.18–0.28 m/Myr. An erratic sandstone boulder within the lag above the Sirius Group yields erosion rates of ∼0.42 ± 0.03 m/Myr, whereas two cobbles embedded within the Sirius Group yield higher rates of 0.81–1.12 m/Myr. Depth profiles of in situ 10 Be and 26 Al indicate no vertical mixing of Sirius Group permafrost since deposition. Depth profile models are best explained by erosion rates of 0.53 +0.13 / −0.12 m/Myr, and an exposure age of 0.78 +0.06 / −0.08 Ma. We view the model “age” to represent the ∼0.8‐million‐year time‐scale for surface lowering equivalent to one attenuation length of cosmic ray production to achieve steady‐state conditions. Continual exhumation of embedded clasts from within the Sirius Group results in an accumulation of clasts forming the observed erosional lag deposit covering the landscape. Our erosion rates of the Sirius Group surface based on in situ 10 Be and 26 Al depth profiles are an order‐of‐magnitude larger than those based on meteoric 10 Be infiltration and further clarification is required.

58 GEOSCIENCES↗

Characterization of the miniPlanacon XPM85112-S-R2D2 MCP-PMT with custom modified backend electronics

We report the results of the measurements of three pieces of the new Photonis miniPLANACON microchannel-plate photomultipliers (MCP-PMTs) intended for use in the demanding environment of the Large Hadron Collider (LHC) beamline as a part of the AFP Time-of-Flight detector. These photomultipliers were modified in cooperation with the manufacturer by using a custom backend and were subjected to numerous tests, with the focus on the rate capability and crosstalk behaviour. We determined that the two of them with a lower MCP resistance are able to operate without significant saturation at an anode current density of 1 μA/cm 2 . These two are, therefore, suitable for the intended use and are currently installed as part of the AFP detector packages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neural network for beam background decomposition in Belle II at SuperKEKB

Here, we describe a neural network for predicting the background hit rate in the Belle II detector produced by the SuperKEKB electron-positron collider. The neural network, BGNet, learns to predict the individual contributions of different physical background sources, such as beam-gas scattering or continuous top-up injections into the collider, to Belle II sub-detector rates. The samples for learning are archived 1 Hz time series of diagnostic variables from the SuperKEKB collider subsystems and measured hit rates of Belle II used as regression targets. We test the learned model by predicting detector hit rates on archived data from different run periods not used during training. We show that a feature attribution method can help interpret the source of changes in the background level over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fe 0.6 Pd 0.4 Te 2 : A New Polymorph of FeTe 2 and PdTe 2 Stable at Ambient Pressure

Whereas pyrite space group is a high pressure polymorph of FeTe 2 , here we report pyrite-type single crystal Fe 0.6 Pd 0.4 Te 2 prepared using Pd substitution on Fe atomic site with ambient pressure crystal growth methods. Here, Fe 0.6(1) Pd 0.4(1) Te 2 single crystals show metal behavior above 15 K abided by Bloch-Grüneisen relation, and display resistivity upturn below 15 K due to disorder-related scattering of correlated electronic states.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Science & Technology Review December 2025 - Optimizing Future Design

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world.

36 MATERIALS SCIENCE↗

Probing the shear-induced microstructure of a smectite clay aqueous suspensions using rheo-USANS and rheo-SIPLI measurements

Hypothesis: The static microstructure of aqueous sodium-montmorillonite (Na-Mt) suspensions at low ionic strengths (where Particle Size/Debye Length ≈1) exhibits both the particle–particle ordering as well as aggregation with repulsive ordered domains having characteristic optical birefringence and attractive aggregated entities larger than 20 µm resulting in ever-increasing yield stresses also known as physical aging-rejuvenation behavior. We hypothesize that the attractive particle–particle aggregation is the underlying cause behind the physical aging-rejuvenation behavior observed in Na-Mt suspensions with no contribution from structural dynamics driven by repulsive particle–particle ordering or jamming. Experiments: We investigate the shear-induced microstructure of aqueous Na-Mt suspensions in the sol and gel state using rheo-ultra-small angle neutron scattering (rheo-USANS) experiments at shear rates of 1, 50, 500, and 2000 s −1 . We also perform rheo-shear-induced polarization light imaging (rheo-SIPLI) experiments to relate ordering with shearing and aging. Findings: Shearing the suspensions at low to moderate shear rates induces particle–particle aggregation and shearing at high shear rates induces the breakage of particle–particle aggregation in the sol and gel states, suggesting the microstructural aggregation in the sol and gel state is shear sensitive and a full rejuvenation or breakage of particle–particle aggregation is only achieved at a minimum critical shear rate. The rheo-SIPLI experiments reveal that the sol and gel state exhibited strong Maltese cross patterns at a shear rate of 1000 s −1 , indicating particle–particle ordering. Post shearing, the gel exhibited temporal evolution of storage modulus without any noticeable influence on the appearance of the Maltese cross pattern indicating physical aging and particle ordering are distinct length scale phenomena in Na-Mt suspensions and the physical aging-rejuvenation behaviour is a feature of particle–particle aggregation as opposed to ordering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science Addendum

Activation detectors developed at LLNL for measuring real-time neutron fluence from fusion sources are used in the broader fusion community. The recommended fluence operating range of this diagnostic is 5x10 2 – 1x10 6 n/cm2. The upper limit on this fluence range is set by the dead time caused by data transfer between the detector and data acquisition computer. Delaying the start of counting is a possible strategy to operate these detectors in higher fluences.

42 ENGINEERING↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Source Localization Using Surrogate Models Constructed from 3-D Monte Carlo Transport Physics Simulations

Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high- delity simulations of radiation transport within an urban domain. The model is constructed to employ a source location (x, y, z) as input and return the estimated count rate for a set of speci ed detector locations. Because MCNP simulations are computationally expensive, we develop e cient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes (GP) and neural networks (NN) that we train and verify using the MCNP simulations. The trained surrogate models provide an e cient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo (MCMC) algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source's location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HAZARD ANALYSIS OF DIGITAL ENGINEERED SAFETY FEATURES ACTUATION SYSTEM IN ADVANCED NUCLEAR POWER PLANTS USING A REDUNDANCY-GUIDED APPROACH

Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. This paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the triggers of potential single points of failure in the design of digital safety systems in advanced plant designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗