Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Resolution theory and static- and frequency dependent cross-talk in piezoresponse force microscopy

Probing materials functionality locally by scanning probe microscopy requires reliable framework for identifying the target signal and separating it from the effects of surface morphology and instrument non-idealities, i.e. instrumental and topographical cross-talk. Here we develop the linear resolution theory framework to describe the cross-talk effects, and apply it for elucidation of frequency dependent cross-talk mechanisms in the Piezoresponse Force Microscopy. The use of band excitation method allows electromechanical/electrical and mechanical/topographic signals to be unambiguously separated. The applicability of functional fit approach and multivariate statistical analysis methods for data identification in band excitation SPM is explored.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Open-loop Band excitation Kelvin Probe Force Microscopy

A multidimensional scanning probe microscopy approach for quantitative, cross-talk free mapping of surface electrostatic properties is demonstrated. Open-loop band excitation Kelvin probe force microscopy (OL BE KPFM) probes the full response-frequency-potential surface at each pixel at standard imaging rates. The subsequent analysis reconstructs work function, tip surface capacitance gradient and resonant frequency maps, obviating feedback-related artifacts. OL BE KPFM imaging is demonstrated for several materials systems with topographic, potential and combined contrast. This approach combines the features of both frequency and amplitude KPFM and allows complete decoupling of topographic and voltage contributions to the KPFM signal.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multifrequency spectrum analysis using fully digital G Mode-Kelvin probe force microscopy

Since its inception over two decades ago, Kelvin probe force microscopy (KPFM) has become the standard technique for characterizing electrostatic, electrochemical and electronic properties at the nanoscale. In this work, we present a purely digital, software-based approach to KPFM utilizing big data acquisition and analysis methods. General Mode (G-Mode) KPFM, works by capturing the entire photodetector data stream, typically at the sampling rate limit, followed by subsequent de-noising, analysis and compression of the cantilever response. We demonstrate that the G-Mode approach allows simultaneous multi-harmonic detection, combined with on-the-fly transfer function correction required for quantitative CPD mapping. The KPFM approach outlined in this work significantly simplifies the technique by avoiding cumbersome instrumentation optimization steps (i.e. lock in parameters, feedback gains etc.), while also retaining the flexibility to be implemented on any atomic force microscopy platform. We demonstrate the added advantages of G-Mode KPFM by allowing simultaneous mapping of CPD and capacitance gradient (C') channels as well as increased flexibility in data exploration across frequency, time, space, and noise domains. As a result, G-Mode KPFM is particularly suitable for characterizing voltage sensitive materials or for operation in conductive electrolytes, and will be useful for probing electrodynamics in photovoltaics, liquids and ionic conductors.

36 MATERIALS SCIENCE↗

Imaging latex–carbon nanotube composites by subsurface electrostatic force microscopy

Electrostatic modes of atomic force microscopy have shown to be non-destructive and relatively simple methods for imaging conductors embedded in insulating polymers. Here we use electrostatic force microscopy to image the dispersion of carbon nanotubes in a latex-based conductive composite, which brings forth features not observed in previously studied systems employing linear polymer films. A fixed-potential model of the probe-nanotube electrostatics is presented which in principle gives access to the conductive nanoparticle's depth and radius, and the polymer film dielectric constant. Comparing this model to the data results in nanotube depths that appear to be slightly above the film–air interface. Furthermore, this result suggests that water-mediated charge build-up at the film–air interface may be the source of electrostatic phase contrast in ambient conditions.

36 MATERIALS SCIENCE↗

Quantitative phase retrieval and characterization of magnetic nanostructures via Lorentz (scanning) transmission electron microscopy

Magnetic materials phase reconstruction using Lorentz transmission electron microscopy (LTEM) measurements have traditionally been achieved using longstanding methods such as off-axis holography (OAH) fast-Fourier transform technique and the transport-of-intensity equation (TIE). The increase in access to processing power alongside the development of advanced algorithms have allowed for phase retrieval of nanoscale magnetic materials with greater efficacy and resolution. Specifically, reverse-mode automatic differentiation (RMAD) and the extended electron ptychography iterative engine (ePIE) are two recent developments of phase retrieval that can be applied to analyzing micro-to-nano- scale magnetic materials. This work evaluates phase retrieval using TIE, RMAD, and ePIE in simulations of Permalloy (Ni 80 Fe 20 ) nanoscale islands, or nanomagnets. Extending beyond simulations, we demonstrate total phase retrieval and image reconstructions of a NiFe nanowire using OAH and RMAD in LTEM and ePIE in Lorentz-mode-4D scanning transmission electron microscopy experiments and determine the saturation magnetization through corroborations with micromagnetic modeling. Finally, we demonstrate the efficacy of these methods in retrieving the total phase and highlight its use in characterizing and analyzing the proximity effect of the magnetic nanostructures.

Lorentz transmission electron microscopy↗

Synergizing human expertise and AI efficiency with language model for microscopy operation and automated experiment design

With the advent of large language models (LLMs), in both the open source and proprietary domains, attention is turning to how to exploit such artificial intelligence (AI) systems in assisting complex scientific tasks, such as material synthesis, characterization, analysis and discovery. Here, we explore the utility of LLMs, particularly ChatGPT4, in combination with application program interfaces (APIs) in tasks of experimental design, programming workflows, and data analysis in scanning probe microscopy, using both in-house developed APIs and APIs given by a commercial vendor for instrument control. We find that the LLM can be especially useful in converting ideations of experimental workflows to executable code on microscope APIs. Beyond code generation, we find that the GPT4 is capable of analyzing microscopy images in a generic sense. At the same time, we find that GPT4 suffers from an inability to extend beyond basic analyses for more in-depth technical experimental design. We argue that an LLM specifically fine-tuned for individual scientific domains can potentially be a better language interface for converting scientific ideations from human experts to executable workflows. Such a synergy between human expertise and LLM efficiency in experimentation can open new doors for accelerating scientific research, enabling effective experimental protocols sharing in the scientific community.

97 MATHEMATICS AND COMPUTING↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Do We Really Need All That Data: From Data to Agency in Automated Microscopy

Microscopy is entering an era of automated laboratories and AI-enabled instruments, often justified by a simple narrative of automating experiments to collect more data and train better models. In this work, we argue that, for microscopy, this framing is incomplete and can be counterproductive.

97 MATHEMATICS AND COMPUTING↗

Dynamics of electron wave propagation in photoionization microscopy. I. Semiclassical open-orbit theory

This is the first of two papers that develop theories and numerical methods for photoionization microscopy of hydrogen atoms in strong electric fields, in semiclassical and quantum-mechanical frameworks, respectively. In this paper, semiclassical open-orbit theory is presented to describe the propagation of outgoing electron waves to macroscopic distances. Spatial distributions of electron probability densities and current densities are predicted. The open-orbit theory, based on an assumption that electron waves propagate along classical paths from a pointlike source to a detector, provides a clear and intuitive physical picture to interpret structures of observed geometrical interference patterns in photoionization microscopy. We calculate photoelectron ejection of hydrogen atoms in electric fields, and comparison is made with quantum-mechanical results, which will be detailed in the second paper [Zhao and Delos, Phys. Rev. A 81, 053418 (2010)]. A strong quantum tunneling effect has been found. Such a tunneling effect should be visible in the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction barrier breakthrough in coherent anti-Stokes Raman scattering microscopy by additional probe-beam-induced phonon depletion

We provide an approach to significantly break the diffraction limit in coherent anti-Stokes Raman scattering (CARS) microscopy via an additional probe-beam-induced photon depletion (APIPD). The additional probe beam, whose profile is doughnut shaped and whose wavelength is different from the Gaussian probe beam, depletes the phonons to yield an unwanted anti-Stokes signal within a certain bandwidth at the rim of the diffraction-limited spot. When the Gaussian probe beam that follows immediately arrives, no anti-Stokes signal is generated in this region, resembling stimulated emission depletion (STED) microscopy, and the spot-generating useful anti-Stokes signals by this beam are substantially suppressed to a much smaller dimension. Scanning the spot renders three-dimensional, label-free, and chemically selective CARS images with subdiffraction resolution. Also, resolution-enhanced images of the molecule, specified by its broadband even-total CARS spectral signals not only by one anti-Stokes signal for its special chemical bond, can be obtained by employing a supercontinuum source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Injection mechanisms in a III -nitride light-emitting diode as seen by self-emissive electron microscopy

Here, we report on the investigation of an electrically biased high efficiency green III-nitride light-emitting diode (LED) by electron emission microscopy (EEM) using a low-energy electron microscope (LEEM). The surface of the LED was activated to negative electron affinity via deposition of a submonolayer of Cs. With the illumination column of the LEEM turned off, upon electrical injection of the LED, we directly image the hot electrons generated by eeh Auger-Meitner nonradiative processes that diffuse through the top p-Ga N layer and emit out the surface of the biased LED. By determining the source of emitted electrons using complementary electron emission spectroscopy measurements, EEM allows us to effectively map the carrier density within the LED. Using EEM, we observed nonelectron emitting regions with a density of approximately 3 × 10 8 cm -2 , identified as V-shaped defects (V-defects). This is confirmed through the corresponding dark spots of panchromatic cathodoluminescence measurements of the same sample and by plan-view transmission electron microscopy. The absence of electron emission at the sidewall of the V-defects can be attributed to several factors, including reduced carrier density in the sidewall quantum wells due to carriers traveling fast through the semipolar sidewalls before being injected into the planar quantum wells, the reduced population of hot electrons surviving diffusion through the thicker p-GaN filling in the V-defect before emission onto vacuum, and a smaller Auger-Meitner coefficient for the low In content semipolar sidewall quantum wells. The stronger electron emission observed at the ridges of most V-defects compared to the planar quantum well regions indicates larger local injected carrier densities, confirming that V-defect sidewalls allow for strong lateral carrier injection when compared to the weaker vertical injection away from the V-defect as evidenced by the weaker electron emission intensity away from the V-defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution diffraction microscopy using the plane-wave field of a nearly diffraction limited focused x-ray beam

X-ray waves in the center of the beam waist of nearly diffraction limited focused x-ray beams can be considered to have amplitude and phase that are both almost uniform, i.e., they are x-ray plane waves. Here we report the results of an experimental demonstration of high-resolution diffraction microscopy using the x-ray plane wave of the synchrotron x-ray beam focused using Kirkpatrik-Baez mirrors. A silver nanocube with an edge length of {approx}100 nm is illuminated with the x-ray beam focused to a {approx}1 {mu}m spot at 12 keV. A high-contrast symmetric diffraction pattern of the nanocube is observed in the forward far field. An image of the nanocube is successfully reconstructed by an iterative phasing method and its half-period resolution is 3.0 nm. This method does not only dramatically improve the spatial resolution of x-ray microscopy but also is a key technology for realizing single-pulse diffractive imaging using x-ray free-electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray microscopy study of chromonic liquid crystal dry film texture

Soft x-ray spectromicroscopy has been used to investigate the degree of the molecular alignment of sulfonated benzo[de]benzo[4.5]imidazo[2,1-a]isoquinoline[7,1], a lyotropic chromonic liquid crystal (LCLC). LCLC thin films cast from concentrated aqua solution (20 % wt.), aligned by shear flow and dried, show strong linear dichroism in their C-, N-, O-, S-K edge near edge x-ray spectra (NEXAFS). The carbon K edge has been used for quantitative evaluation of the orientational texture of the films at a submicron spatial scale. This has verified there is predominantly in-plane alignment of the LC director. To highlight the role of hydrophobic-hydrophilic interactions, two stereoisomers of the same dye has been synthesized with different positioning of terminal sulfonate groups, in the form of a mixture of isomers with sulfonate groups in 2,10 and 2,11 positions (Y104 compound) and in a 5,10-disulfo arrangement (Y105). Both compounds develop characteristic herringbone-type texture with similar domain sizes. Polarized optical microscopy and higher resolution x-ray microscopy show sinusoidal-like undulations of the molecular director, with occasional crisscross appearance. Such behavior is found to be consistent with earlier observation of striations, characteristic of the columnar phase. The drastic difference in the degree of undulation ({+-}15 deg. in Y104 and {+-}7 deg. in Y105 films) and long period of undulation (approaching the film thickness) requires further analysis. It was also found that the degree of in-plane order within domains changes from 0.8 for Y104 to >0.9 in Y105 films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Imaging of Buried Structures with Elemental Specificity Using Resonant X-Ray Diffraction Microscopy

We report the first demonstration of resonant x-ray diffraction microscopy for element specific imaging of buried structures with a pixel resolution of {approx}15 nm by exploiting the abrupt change in the scattering cross section near electronic resonances. We performed nondestructive and quantitative imaging of buried Bi structures inside a Si crystal by directly phasing coherent x-ray diffraction patterns acquired below and above the Bi M{sub 5} edge. We anticipate that resonant x-ray diffraction microscopy will be applied to element and chemical state specific imaging of a broad range of systems including magnetic materials, semiconductors, organic materials, biominerals, and biological specimens.

36 MATERIALS SCIENCE↗

Hard-X-Ray Phase-Difference Microscopy Using a Fresnel Zone Plate and a Transmission Grating

Novel hard x-ray phase imaging microscopy that simply uses an objective and a transmission grating is described. The microscope generated an image that exhibited twin features of a sample with an opposite phase contrast having a separation of a specific distance. Furthermore, the twin features were processed to generate an image mapping the x-ray phase shift through a simple algorithm. The presence of the grating did not degrade the spatial resolution of the microscope. The sensitivity of our microscope to light elements was about 2 orders of magnitude higher than that of the absorption contrast microscope that was attained by simply removing the grating. Our method is attractive for easily appending a quantitative phase-sensitive mode to normal x-ray microscopies, and it has potentially broad applications in biology and material sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical tuning of the diamond Fermi level measured by correlated scanning probe microscopy and quantum defect spectroscopy

Quantum technologies based on quantum point defects in crystals require control over the defect charge state. Here we tune the charge state of shallow nitrogen-vacancy and silicon-vacancy centers by locally oxidizing a hydrogenated surface with moderate optical excitation and simultaneous spectral monitoring. The loss of conductivity and change in work function due to oxidation are measured in atmosphere using conductive atomic force microscopy and Kelvin probe force microscopy (KPFM). We correlate these scanning probe measurements with optical spectroscopy of the nitrogen-vacancy and silicon-vacancy centers created via implantation 15–25 nm beneath the diamond surface and annealing. The observed charge state of the defects as a function of optical exposure demonstrates that laser oxidation provides a way to precisely tune the Fermi level over a range of at least 2.00 eV. We also observe a significantly larger oxidation rate for implanted surfaces compared to unimplanted surfaces under ambient conditions. Here, combined with knowledge of the electron affinity of a surface, these results suggest KPFM is a powerful, high-spatial-resolution technique to advance surface Fermi level engineering for charge stabilization of quantum defects.

36 MATERIALS SCIENCE↗

Combining X-ray and electron-microscopy data to solve crystal structures

Overview and examples of combined use of X-ray and electron-microscopy data. Low-resolution electron-microscopy reconstructions can be used as search models in molecular replacement or may be combined with existing monomeric structures in order to produce multimeric models suitable for molecular replacement. The technique is described in the case of viral and subviral particles as well as in the case of oligomeric proteins.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polarization-resolved second-harmonic generation microscopy as a method to visualize protein-crystal domains

Polarization-resolved second-harmonic generation microscopy is applied to the identification of multiple crystalline domains within protein-crystal samples. Polarization-resolved second-harmonic generation (PR-SHG) microscopy is described and applied to identify the presence of multiple crystallographic domains within protein-crystal conglomerates, which was confirmed by synchrotron X-ray diffraction. Principal component analysis (PCA) of PR-SHG images resulted in principal component 2 (PC2) images with areas of contrasting negative and positive values for conglomerated crystals and PC2 images exhibiting uniformly positive or uniformly negative values for single crystals. Qualitative assessment of PC2 images allowed the identification of domains of different internal ordering within protein-crystal samples as well as differentiation between multi-domain conglomerated crystals and single crystals. PR-SHG assessments of crystalline domains were in good agreement with spatially resolved synchrotron X-ray diffraction measurements. These results have implications for improving the productive throughput of protein structure determination through early identification of multi-domain crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗