Engineering PapersSearch

SEARCH · Engineering Papers

Results for “wall insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Numerical solutions for the spin-up of a stratified fluid

The model of Warn-Varnas et al. (1978) is used to numerically examine the spin-up flow of a thermally stratified fluid in a cylinder with an insulating side wall, and comparison of the results with the laser-Doppler measurements of Lee (1975) shows excellent agreement. It is shown that flow gradients are created in the interior of the fluid during the meridional circulation spin-up phase, and that the azimuthal flow decayed faster than has been predicted by Wallin (1969). It is established that viscous diffusion in the interior, arising from the interior-flow gradients, is the cause of the discrepancy with Wallin's theory.

Hyun, J. M.

The structural response of a rail accelerator

The transient response of a 0.4 by 0.6 cm rectangular bore rail accelerator was analyzed by a three dimensional finite element code. The copper rail deflected to a peak value of 0.08 mm in compression and then oscillated at an amplitude of 0.02 mm. Simultaneously the insulating side wall of glass fabric base, epoxy resin laminate (G-1o) was compressed to a peak value of 0.13 mm and rebounded to a steady state in extension. Projectile pinch or blowby due to the rail extension or compression, respectively, can be identified by examining the time history of the rail displacement. The effect of blowby was most significant at the side wall characterized by mm size displacement in compression. Dynamic stress calculations indicate that the G-10 supporting material behind the rail is subjected to over 21 MPa at which the G-10 could fail if the laminate was not carefully oriented. Results for a polycarbonate resin (Lexan) side wall show much larger displacements and stresses than for G-10. The tradeoff between the transparency of Lexan and the mechanical strength of G-10 for sidewall material is obvious. Displacement calculations from the modal method are smaller than the results from the direct integration method by almost an order of magnitude, because the high frequency effect is neglected.

Wang, S. Y.

The structural response of a rail acceleration

The transient response of a 0.4 by 0.6 cm rectangular bore rail accelerator was analyzed by a three dimensional finite element code. The copper rail deflected to a peak value of 0.08 mm in compression and then oscillated at an amplitude of 0.02 mm. Simultaneously the insulating side wall of glass fabric base, epoxy resin laminate (G-10) was compressed to a peak value of 0.13 mm and rebounded to a steady state in extension. Projectile pinch or blowby due to the rail extension or compression, respectively, can be identified by examining the time history of the rail displacement. The effect of blowby was most significant at the side wall characterized by mm size displacement in compression. Dynamic stress calculations indicate that the G-10 supporting material behind the rail is subjected to over 21 MPa at which the G-10 could fail if the laminate was not carefully oriented. Results for a polycarbonate resin (Lexan) side wall show much larger displacements and stresses than for G-10. The tradeoff between the transparency of Lexan and the mechanical strength of G-10 for sidewall material is obvious. Displacement calculations from the modal method are smaller than the results from the direct integration method by almost an order of magnitude, because the high frequency effect is neglected. Previously announced in STAR as N83-35412

Wang, S. Y.

Finite-amplitude models of convection in the early mantle

Models of finite-amplitude, time-dependent mantle convection at Reynolds number ten million are calculated. The models are based on the Boussinesq approximation for convection at infinite Prandtl number and treat convection in a two-dimensional, Cartesian coordinate box with an aspect ratio of 1.4. The initial conditions consist of a static fluid with a purely conductive temperature profile, while the boundary conditions are taken to be free slip, with impenetrable insulating side walls. The initial conditions are found to result in an initial burst of convection that reverses the horizontally averaged temperature gradient, making the middle layers stable with respect to convection. With bottom heating and cooling of the top, two distinct layers of convective cells occur; with top cooling only, the upper layer alone convects.

Boss, A. P.

Linear and nonlinear pattern selection in Rayleigh-Benard stability problems

A new algorithm is introduced to compute finite-amplitude states using primitive variables for Rayleigh-Benard convection on relatively coarse meshes. The algorithm is based on a finite-difference matrix-splitting approach that separates all physical and dimensional effects into one-dimensional subsets. The nonlinear pattern selection process for steady convection in an air-filled square cavity with insulated side walls is investigated for Rayleigh numbers up to 20,000. The internalization of disturbances that evolve into coherent patterns is investigated and transient solutions from linear perturbation theory are compared with and contrasted to the full numerical simulations.

Davis, Sanford S.

Thermal Structures Technology Development for Reusable Launch Vehicle Cryogenic Propellant Tanks

Analytical and experimental studies conducted at the NASA Langley Research Center for investigating integrated cryogenic propellant tank systems for a Reusable Launch Vehicle are described. The cryogenic tanks are investigated as an integrated tank system. An integrated tank system includes the tank wall, cryogenic insulation, Thermal Protection System (TPS) attachment sub-structure, and TPS. Analysis codes are used to size the thicknesses of cryogenic insulation and TPS insulation for thermal loads, and to predict tank buckling strengths at various ring frame spacings. The unique test facilities developed for the testing of cryogenic tank components are described. Testing at cryogenic and high-temperatures verifies the integrity of materials, design concepts, manufacturing processes, and thermal/structural analyses. Test specimens ranging from the element level to the subcomponent level are subjected to projected vehicle operational mechanical loads and temperatures. The analytical and experimental studies described in this paper provide a portion of the basic information required for the development of light-weight reusable cryogenic propellant tanks.

Johnson, Theodore F.

Microshutter Arrays for the NGST NIRSpec

We are developing a programmable multiobject field selector for the NGST NIRSpec. This device is a microshutter array, a close-packed 2000 x 2000 array of 100 micrometer x 100 micrometer shutters fabricated with Micro-ElectroMechanical Systems (MEMS) technologies. The shutters are opened using a magnet scanned over the array. The shutters are held open by electrostatic potentials on adjacent vertical electrodes. Modeling of the magnetic actuation of the microshutters allowed optimization of the magnetic field configuration, the distance between magnet and shutters, and the force and torque produced by the magnet. The results of laboratory tests are consistent with our modeling. We have demonstrated actuation, latching and addressing. We are able to rotate shutters out of the plane up to 90 degree and more, to latch them electrostatically to the walls and release them selectively. During the last six month all critical elements of the array have been demonstrated. Fabrication processes were developed to deposit vertical electrodes on support grid side walls and insulated light-shields that block the gaps between shutters and the support grid. Physical optics analysis was performed to assess the expected optical performance of the microshutters. A preliminary Fourier optics analysis on the microshutter array performance has been carried out. More detailed analysis of wave propagation through 3D structures is a next step. An optical test station for verifying optical parameters of the shutter array at room temperature has been developed. It allows to measure parameters, such as transmission, scattering, contrast ratio, and diffraction of the array structure. Initial data have been acquired and are being analyzed and compared to theoretical predictions.

Moseley, Harvey

Thermal Structures Technology Development for Reusable Launch Vehicle Cryogenic Propellant Tanks

Analytical and experimental studies conducted at the NASA, Langley Research Center (LaRC) for investigating integrated cryogenic propellant tank systems for a reusable launch vehicle (RLV) are described. The cryogenic tanks are investigated as an integrated tank system. An integrated tank system includes the tank wall, cryogenic insulation, thermal protection system (TPS) attachment sub-structure, and TPS. Analysis codes are used to size the thicknesses of cryogenic insulation and TPS insulation for thermal loads, and to predict tank buckling strengths at various ring frame spacings. The unique test facilities developed for the testing of cryogenic tank components are described. Testing at cryogenic and high-temperatures verifies the integrity of materials, design concepts, manufacturing processes, and thermal/structural analyses. Test specimens ranging from the element level to the subcomponent level are subjected to projected vehicle operational mechanical loads and temperatures. The analytical and experimental studies described in this paper provide a portion of the basic information required for the development of light-weight reusable cryogenic propellant tanks.

Johnson, Theodore F.

Wider-Opening Dewar Flasks for Cryogenic Storage

Dewar flasks have been proposed as containers for relatively long-term (25 days) storage of perishable scientific samples or other perishable objects at a temperature of 175 C. The refrigeration would be maintained through slow boiling of liquid nitrogen (LN2). For the purposes of the application for which these containers were proposed, (1) the neck openings of commercial off-the-shelf (COTS) Dewar flasks are too small for most NASA samples; (2) the round shapes of the COTS containers give rise to unacceptably low efficiency of packing in rectangular cargo compartments; and (3) the COTS containers include metal structures that are too thermally conductive, such that they cannot, without exceeding size and weight limits, hold enough LN2 for the required long-term-storage. In comparison with COTS Dewar flasks, the proposed containers would be rectangular, yet would satisfy the long-term storage requirement without exceeding size and weight limits; would have larger neck openings; and would have greater sample volumes, leading to a packing efficiency of about double the sample volume as a fraction of total volume. The proposed containers would be made partly of aerospace- type composite materials and would include vacuum walls, multilayer insulation, and aerogel insulation.

Ruemmele, Warren P.

An experimental and analytical investigation of thermoacoustic convection heat transfer in gravity and zero-gravity environments

An experimental and analytical study of Thermoacoustic Convection heat transfer in gravity and zero-gravity environments is presented. The experimental apparatus consisted of a cylinder containing air as a fluid. The side wall of the cylinder was insulated while the bottom wall was allowed to remain at the ambient temperature. The enclosed air was rapidly heated by the top surface which consisted of a thin stainless steel foil connected to a battery pack as the power source. Thermocouples were used to measure the transient temperature of the air on the axis of the cylinder. The ouput of the thermocouples was displayed on digital thermometers and the temperature displays were recorded on film using a high-speed movie camera. Temperature measurements were obtained in the zero-gravity environment by dropping the apparatus in the 2-Seconds Zero-Gravity Drop Tower Facilities of NASA Lewis Research Center. In addition, experiments were also performed in the gravity environment and the results are compared in detail with those obtained under zero-gravity conditions.

Parang, Masood

An Instrument for Real-Time Measurement of Solid Rocket Motor Insulation Erosion

An instrument (eroding potentionmeter) has been designed to measure real-time case wall and inhibitor insulation char depth within a rocket motor during firing. Thus measurement can be close to the real-time recession of the insulation surface. The eroding potentionmeter consists of two small (3 mils 9in diameter) twisted resistive wires that are polyimide insulated. The wire pair form an electrical circuit and will recede with the erosion of the rocket motor internal insulation. A constant current applied along the wires will detect the resistance change via a voltage drop across the wires as the wire pair recedes with the decomposition fo the insulation. The eroding potentionmeter, as presently designed, can be an effective tool for real time measurement of internal insulation recession of a solid rocket motor. This tool will provide a way to accurately measure inhibitor performance or to measure flight effects of insulation erosion on a flight test. The eroding potentiometer has been verified on a plasma torch test and two static tests of a small solid rocket motor. There are some irregularities in the measured date, but the data remains useful in determining the real-time performance of internal insulation during a motor firing.

McWhorter, B. B.

Sensitivity of dual-wall structures under hypervelocity impact to multi-layer thermal insulation thickness and placement

Results are presented from an experimental study in which Al dual-wall structures were tested, under various high-speed impact conditions, with a view to the effect of multilayer insulation thickness and location on perforation resistance. Attention is given to comparisons of the damage sustained by dual-wall systems with multilayer insulation blankets of various thicknesses and at various locations within the dual-wall system, under comparable impact loading conditions. The placement of the insulation has a significant effect on the ballistic limit of the dual-wall structures considered, while reducing insulation thickness by as much as a third did not.

Schonberg, William P.

Studies relating to temperature control of a large scale telescope

Analytical methods are developed for estimating the circumferential and longitudinal temperature distributions in a large space telescope, idealized as a simple insulated tube with a flat mirror across one end. The effects of wall conduction, multilayer insulation, thermal coatings, heat pipes, and heated collars are analyzed, with numerical examples. For most of the study, the only thermal input to the tube was assumed to be from steady solar irradiation from one side, as in a geosynchronous orbit. Unsteady heat flow through the insulation, as in alternating sunlight and shadow of a low orbit, is briefly discussed.

Katzoff, S.

Néel domain walls with bistable chirality in a perpendicularly magnetized ferrimagnetic insulator

Field-free spin-orbit torque-driven domain wall motion in magnetic thin films with perpendicular magnetic anisotropy (PMA) requires the domain walls to have Néel character. Conventionally, Néel domain walls are stabilized by the Dzyaloshinskii-Moriya interaction (DMI) in ultrathin films. Here, in a europium iron garnet thin film with PMA and an additional uniaxial in-plane anisotropy, we demonstrate two bistable Néel domain wall states in the absence of DMI, and the capability to toggle the wall states with an in-plane field pulse and consequently their directions of motion under a current pulse. We present a phase diagram for the bistable Néel domain wall states as a function of in-plane field pulse width and amplitude. By fitting the experimental data to an analytical model of Néel wall reversal through the nucleation and propagation of Bloch lines, we extract the length of the initial reversed domain wall segment and Bloch line nucleation energy barrier. Current-driven motion of in-plane anisotropy stabilized Néel walls is qualitatively different from that of DMI-stabilized ones owing to the different symmetry of the effective fields that stabilize the Néel configuration. Furthermore, we present a proof of principle demonstration for 2-bit random number generation based on the stochastic reversal of domain wall chirality. These results provide critical insight into the topological energy barrier of Bloch lines and identify paths towards domain wall-based memory and computing devices.

36 MATERIALS SCIENCE

Ballistic limit regression analysis for Space Station Freedom meteoroid and space debris protection system

Relationships defining the ballistic limit of Space Station Freedom's (SSF) dual wall protection systems have been determined. These functions were regressed from empirical data found in Marshall Space Flight Center's (MSFC) Hypervelocity Impact Testing Summary (HITS) for the velocity range between three and seven kilometers per second. A stepwise linear least squares regression was used to determine the coefficients of several expressions that define a ballistic limit surface. Using statistical significance indicators and graphical comparisons to other limit curves, a final set of expressions is recommended for potential use in Probability of No Critical Flaw (PNCF) calculations for Space Station. The three equations listed below represent the mean curves for normal, 45 degree, and 65 degree obliquity ballistic limits, respectively, for a dual wall protection system consisting of a thin 6061-T6 aluminum bumper spaced 4.0 inches from a .125 inches thick 2219-T87 rear wall with multiple layer thermal insulation installed between the two walls. Normal obliquity is d(sub c) = 1.0514 v(exp 0.2983 t(sub 1)(exp 0.5228). Forty-five degree obliquity is d(sub c) = 0.8591 v(exp 0.0428) t(sub 1)(exp 0.2063). Sixty-five degree obliquity is d(sub c) = 0.2824 v(exp 0.1986) t(sub 1)(exp -0.3874). Plots of these curves are provided. A sensitivity study on the effects of using these new equations in the probability of no critical flaw analysis indicated a negligible increase in the performance of the dual wall protection system for SSF over the current baseline. The magnitude of the increase was 0.17 percent over 25 years on the MB-7 configuration run with the Bumper II program code.

Jolly, William H.

Structural heat pipe

A combined structural reinforcing element and heat transfer member is disclosed for placement between a structural wall and an outer insulation blanket. The element comprises a heat pipe, one side of which supports the outer insulation blanket, the opposite side of which is connected to the structural wall. Heat penetrating through the outer insulation blanket directly reaches the heat pipe and is drawn off, thereby reducing thermal gradients in the structural wall. The element, due to its attachment to the structural wall, further functions as a reinforcing member.

Ollendorf, S.

A spectral method determination of the first critical Rayleigh number for a low-Prandtl number crystal melt in a cylindrical container

The onset of laminar axisymmetric Rayleigh-Benard convection is investigated for a low-Prandtl number liquid metal in a cylindrical container. All surfaces are considered to be solid and no-slip. Two separate cases are examined for the thermal boundary conditions at the side wall, one with conducting and the other with insulated surface. The governing Boussinesq system is first perturbed and then simplified by introducing a Stokes stream function. Subsequently, a Chebyshev Galerkin spectral model is employed to reduce the simplified system to a system of first-order nonlinear ordinary differential equations. A local stability analysis determines the two values of the first critical Rayleigh number, Ra(sub cl), for the insulated and conducting side walls. As expected, the conducting Ra(sub cl) value of 2882.5 obtained from the present approach exceeded the corresponding insulated Ra(sub cl) value of 2331.6. For the insulated case, an earlier study using a different numerical approach suggests that Ra(sub cl) = 2261.9, while an experimental study measured Ra(sub cl) = 2700.

Dietz, C. M., Jr.