Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “virtual utility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photodamage and Repair in Higher Plant Photosynthesis (Final Technical Report)

Elucidation of the functional properties and structural organization of membrane protein complexes is one of the central objectives of current biochemical investigation. One of the most intriguing aspects of membrane protein function is its role in the mediation of energy transduction in photosynthetic organisms. Light energy, which is the product of a most violent physical process, fusion, is transformed into biological energy equivalents utilized by the photosynthetic cell. This photosynthetic process provides both the carbohydrate that lies at the base of virtually all food chains and, as a byproduct, all of the atmospheric oxygen utilized by heterotrophic organisms. The photosynthetic apparatus, however, is quite susceptible to damage by Reactive Oxygen Species (ROS). These species include O2 ·– , ·OH, H 2 O 2 and 1 O 2 . The production of ROS is an unavoidable byproduct of electron transport under aerobic conditions and these can damage lipids, nucleic acids and proteins. Our research has centered on the identification of amino acid oxidative damage which occurs in the vicinity of photosynthetic energy transfer cofactors. These cofactors participate in excitation energy transfer and linear electron transport within Photosystem II, the Cytochrome b 6 ƒ complex and Photosystem I. Additionally, we have participated in a number of productive collaborations leveraging our expertise in photosynthetic measurements and mass spectrometry to assist other investigators in their research.

59 BASIC BIOLOGICAL SCIENCES↗

CommAwareNet: Towards Communication‐Aware Smart Facilities: Designing an Energy‐Efficient High‐Data‐Rate and Reliable Hybrid THz/VLC Comm. Arch. Reinforced with Intelligent Surfaces for Future Network

This project will develop foundations for energy-efficient, high-data-rate, and reliable communication links for next-generation advanced wireless technologies. The Internet of Everything is emerging as a major technology that can establish a massively connected network among both human-type users and machine-type devices. Particularly, massive machine-type communication is becoming the dominant communication paradigm for numerous emerging areas, including data center networking and wireless backhaul, healthcare (e-health), manufacturing (industry 4.0), utilities, transportation (connected cars and public safety), and virtual or augmented reality for human-machine interaction applications. The rising demand for high data rates, especially in indoor scenarios and densely populated outdoor environments, will eventually overload conventional RF-based technologies. This project aims to conduct fundamental research to design, optimize, and validate a communication-aware, energy-efficient, and reliable network (CommAwareNet) architecture for future smart facilities and environments that require unprecedented high throughput needs for massive numbers of the machine- and human-type users. The scientific and technical merit of this work lies in the research required to bring the proposed transformative CommAwareNet solution into fully functional and practical architecture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Power Plant Profiles and Inventory

Increased adoption of distributed energy resources (DERs), growing quantities of renewable energy on the grid, and load growth from buildings, industry, and data centers are driving the need for increased demand flexibility and solutions to reliably and cost-effectively balance electricity supply and demand. In order to deploy DERs on a similar scale as conventional supply-side resources, utilities and state decision-makers are exploring a range of programmatic approaches and market designs, including Virtual Power Plants (VPP). Based on interviews with more than twenty subject matter experts on VPPs, the Insights into Scaling Virtual Power Plants report and appendix outlines actions that utilities and regulators can take to expand VPPs, organized around successful VPP designs, deployment, and operation. The companion report, Virtual Power Plant Profiles and Inventory describes three conceptual profiles that can be used as a starting point to facilitate clear discussions among regulators, utilities, solution providers, and stakeholders about various VPP strategies. It also includes details on more than 790 demand response programs and net energy metering solar plus battery programs, and 180 VPP programs. The Inventory is provided below as a separate file.

24 POWER TRANSMISSION AND DISTRIBUTION↗

QuDPy: A Python-based tool for computing ultrafast non-linear optical responses

Nonlinear Optical Spectroscopy is a well-developed field with theoretical and experimental advances that have benefited multiple disciplines, including chemistry, biology, and physics. However, for the accurate interpretation of the corresponding multi-dimensional spectra, there is a need for precise quantum dynamical simulations based on model Hamiltonians. In this article, we present the initial release of our code, QuDPy (Quantum Dynamics in Python), which provides a robust numerical platform for performing quantum dynamics simulations based on model systems, including open quantum systems. Furthermore, a distinguishing feature of our approach is the ability to specify various high-order optical response pathways in the form of double-sided Feynman diagrams through a straightforward input syntax. This syntax outlines the time-ordering of ket-sided or bra-sided optical interactions acting on the time-evolving density matrix of the system. We utilize the quantum dynamics capabilities of QuTip to simulate the spectral response of complex systems, allowing us to compute virtually any $n$-th order optical response of the model system. To illustrate the utility of our approach, we provide a series of example calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital Twin for Optimizing Real-time Economy of the Integrated Energy Systems

Economic and safe operation of integrated energy systems (IES) requires real-time optimization (RTO) of the control and actions conducted on each system component. In this regard, digital twins (DTs), which consist of a physical system, a virtual system, and the data communication that occurs between the two, are essential for effective RTO. Through the data warehouse, the virtual system is constantly updated with real-time data from the physical system, and functions as the model in the optimization framework. The reduced-order model of the dynamic process model in the virtual system is used in the optimization framework. The optimization results are then returned, via the data warehouse, as control actions to the physical system. This work demonstrates the software capabilities of DT assets for an IES in the context of preparing a DT for an experimental system comprised of Idaho National Laboratory (INL)’s Thermal Energy Delivery System and battery system. For the virtual demonstration, the DTs encompass (1) a physical system, including the Modelica models of the Thermal Energy Delivery System and the battery system; (2) virtual optimization via the Optimization of Real-Time Capacity Allocation (ORCA) platform; and (3) the open-source data warehouse software DeepLynx. This work assesses the performance of ORCA, which utilizes a reduced-order model built using the Risk Analysis Virtual Environment (RAVEN) and trained on the Modelica models and real-time data pipeline through the graph database hosted in DeepLynx. The proposed optimization workflow will be an RTO model based on DTs and the data they generate.

25 ENERGY STORAGE↗

Predicting runtime and resource utilization of jobs on integrated cloud and HPC systems

Recent advances in virtualization technologies used in cloud computing offer performance that closely approaches bare-metal levels. Combined with specialized instance types and high-speed networking services for cluster computing, cloud platforms have become a compelling option for high-performance computing (HPC). However, most current batch job schedulers in HPC systems are designed for homogeneous clusters and make decisions based on limited information about jobs and system status. Scientists typically submit computational jobs to these schedulers with a requested runtime that is often over- or under-estimated. More accurate runtime predictions can help schedulers make better decisions and reduce job turnaround times. Here, they can also support decisions about migrating jobs to the cloud to avoid long queue wait times in HPC systems.

97 MATHEMATICS AND COMPUTING↗

Virtual Trajectories for I–24 MOTION: Data and Tools

This paper introduces a toolbox for generating virtual trajectories, which we call VT-tools v1.0, to address challenges in analyzing large but imperfect trajectory datasets. VT-tools v1.0 is able to generate virtual trajectories from large raw datasets that are typically challenging to process due to their size. We also provide a set of these virtual trajectories resulting from I–24 MOTION INCEPTION v1.0 data and demonstrate the practical utility of these trajectories in as-sessing speed variability and travel times across different lanes within the INCEPTION dataset. The virtual trajectory toolbox opens future research on traffic waves and their impact on energy. The VT-tools v1.0 Python implementation and sample data are publicly available at https://i24motion.org.

42 ENGINEERING↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗

Structure–Property Relationships of Recycled Lithium-Ion Battery Cathodes: Microstructure Optimization Using Virtual Materials Testing

The increasing demand for sustainable battery technologies requires effective recycling strategies for end-of-life lithium-ion battery cathodes. In this study, virtual materials testing, a well-established framework for modeling conventionally manufactured NMC-based cathodes, is applied to partially recycled cathodes. To this end, virtual cathodes consisting of mixtures of pristine and recycled NMC particles are utilized to systematically analyze structure–property relationships depending on mixing ratios and different spatial arrangement strategies. For this purpose, a stochastic 3D model is developed that is capable of generating virtual cathodes with arbitrary volume fractions of active materials and mixing ratios of pristine and recycled NMC particles. Particularly, the stochastic 3D model can mimic the different size distributions of pristine and recycled particles that are observed in image data. Additionally, the model allows the structuring of pristine and recycled NMC either uniformly mixed or layer-wise arranged, mimicking single- and dual-layer cathodes. Subsequently, a systematic computational analysis is conducted to assess the influence of increasing active material ratios of recycled particles, ranging from 0 % to 100 %, while maintaining a constant overall active material volume fraction. The impact of particle mixing on cathode performance is evaluated by examining transport-relevant geometrical descriptors and effective properties, such as geodesic tortuosity, specific surface area, and tortuosity factor.

25 ENERGY STORAGE↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coordination and Planning for Water and Power System Resilience (Workshop Report)

Water and power utilities are interdependent, subject to many of the same natural and manmade hazards, and critical for the well-being of communities and society. In April 2021, a virtual workshop was held that brought together representatives from water, wastewater, and electric utilities; government organizations; water and electricity based professional associations; consulting firms; and researcher organizations to explore water and power system interdependencies and resilience. The workshop, organized by Pacific Northwest National Laboratory (PNNL) and funded by the United States Department of Energy (DOE) Water Power Technologies Office (WPTO), explored a vision for coordinated and resilient water and electric utilities of the future and identified barriers and strategies for increased coordination and integrated planning between water and power utilities. Workshop participants suggested next steps and areas where federal research and support would be beneficial. This report documents that key outcomes of the workshop.

13 HYDRO ENERGY↗

Regulators’ Financial Toolbox: Virtual Power Plants Summary

On June 21, 2023, NARUC’s Center for Partnerships & Innovation (CPI) and the NASEO-NARUC GridInteractive Efficient Buildings (GEB) Working Group co-hosted a Regulators’ Financial Toolbox Webinar on the topic of virtual power plants (VPPs). The webinar featured opening remarks from moderator Commissioner Cecile Fraser of the Public Utilities Commission of Massachusetts and presentations from Ryan Hledik, Principal, The Brattle Group; Brenda Chew, Director of Product Management, Virtual Peaker; and Franco Albi, Director of Regional Integration, Portland General Electric.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and validation of a mathematical model of heart rate response to fluid perturbation

Physiological closed-loop controlled (PCLC) medical devices monitor and automatically adjust the patient’s condition by using physiological variables as feedback, ideally with minimal human intervention to achieve the target levels set by a clinician. PCLC devices present a challenge when it comes to evaluating their performance, where conducting large clinical trials can be expensive. Virtual physiological patients simulated by validated mathematical models can be utilized to obtain preclinical evidence of safety and assess the performance of the PCLC medical device during normal and worst-case conditions that are unlikely to happen in a limited clinical trial. A physiological variable that plays a major role during fluid resuscitation is heart rate (HR). For in silico assessment of PCLC medical devices regarding fluid perturbation, there is currently no mathematical model of HR validated in terms of its predictive capability performance. This paper develops and validates a mathematical model of HR response using data collected from sheep subjects undergoing hemorrhage and fluid infusion. The model proved to be accurate in estimating the HR response to fluid perturbation, where averaged between 21 calibration datasets, the fitting performance showed a normalized root mean square error (NRMSE) of 7.41 ± 2.8%. The model was also evaluated in terms of model predictive capability performance via a leave-one-out procedure (21 subjects) and an independent validation dataset (6 subjects). Two different virtual cohort generation tools were used in each validation analysis. The generated envelope of virtual subjects robustly met the defined acceptance criteria, in which 95% of the testing datasets presented simulated HR patterns that were within a deviation of 50% from the observed data. In addition, out of 16000 and 18522 simulated subjects for the leave one-out and independent datasets, the model was able to generate at least one virtual subject that was close to the real subject within an error margin of 9.56 ± 3.15% and 11.1 ± 1.22% NRMSE, respectively. In conclusion, the model can generate valid virtual HR physiological responses to fluid perturbation and be incorporated into future non-clinical simulated testing setups for assessing PCLC devices intended for fluid resuscitation.

59 BASIC BIOLOGICAL SCIENCES↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time-Sensitive Quantum Key Distribution (TSQKD)

This is the final report for the Time-Sensitive Quantum Key Distribution (TSQKD) project and summarizes the demonstration and longer-term field testing at an electric utility, EPB of Chattanooga, in Chattanooga, TN. The demonstration was held virtually (due to the COVID pandemic) and successfully executed the tests outlined in a prior report, “Task 10: Develop a QKD Time-Sensitive Networking Test Suite” submitted 9/30/2020. The portable test equipment explained in Task 10 and earlier task reports was tested at GE Research remotely connected with Qubitekk’s QKD equipment in San Diego, CA. Then the equipment was shipped to Qubitekk for physical integration with Qubitekk’s Quantum DataLoc™ Key Server 1570nm (http://qubitekk.com/products/qkd-for-industrial-control-systems-ics/). The portable test equipment was shipped from Qubitekk to EPB for demonstration and extended field testing. A summary of the demonstration and test results are described in this report. The demo and extended field test results are enabled by the NETCONF/YANG IEEE P1913 data management model developed as part of this project (Task 5). The NETCONF/YANG IEEE P1913 data management model demonstrated significant practical utility in providing a common means of monitoring and configuring the QKD system. All data in this report comes from the IEEE P1913 data management model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Utility Distributed Energy Resource Management System and Aggregators for Evolving Distribution System Operators

With the rapid integration of distributed energy resources (DERs), distribution utilities are faced with new and unprecedented issues. New challenges introduced by high penetration of DERs range from poor observability to overload and reverse power flow problems, under-over-voltages, maloperation of legacy protection systems, and requirements for new planning procedures. Distribution utility personnel are not adequately trained, and legacy control centers are not properly equipped to cope with these issues. Fortunately, distribution energy resource management systems (DERMSs) are emerging software technologies aimed to provide distribution system operators (DSOs) with a specialized set of tools to enable them to overcome the issues caused by DERs and to maximize the benefits of the presence of high penetration of these novel resources. However, as DERMS technology is still emerging, its definition is vague and can refer to very different levels of software hierarchies, spanning from decentralized virtual power plants to DER aggregators and fully centralized enterprise systems (called utility DERMS). Although they are all frequently simply called DERMS, these software technologies have different sets of tools and aim to provide different services to different stakeholders. This paper explores how these different software technologies can complement each other, and how they can provide significant benefits to DSOs in enabling them to successfully manage evolving distribution networks with high penetration of DERs when they are integrated together into the control centers of distribution utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗