ARM Aerial Facility (AAF) Fiber Optic Temperature Sensor
ARM Aerial Facility (AAF) Fiber Optic Temperature Sensor
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
ARM Aerial Facility (AAF) Fiber Optic Temperature Sensor
New instrument measures temperature reliabily and accurately. Device uses Fabry-Perot multiple-beam sensor. Both temperature sensor and optical lines are free of all electrical and electromagnetic effects and interference. Variation in spacer is made sensitive to other physical quantities, such as pressure. Sensing element itself is quite small, enhancing use in confined areas.
The goal of this work is to investigate the performance of sapphire optical fiber temperature sensors and develop clad sapphire optical fibers for in-pile instrumentation. This work tests the distributed sensing performance of sapphire sensors by using optical backscatter reflectometry methods under combined radiation/temperature effects and high fluence. A series of irradiations will be completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine an operational limit for the sensors.
The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.
The Jimsonde, a high-resolution lightweight temperature sensor developed for use with the FPS-16 Radar/Jimsphere wind system, and its related systems are discussed; and an error analysis that shows the sonde to have an rms error of 0.41 C at sea level and 0.56 C at 18 km is presented. Five flight tests, a sequence of four tests and one individual test, of the Jimsonde were made. For comparative purposes, radiosonde temperature data are presented along with the Jimsonde data.
Weed Instrument Inc. produces a line of thermocouples - temperature sensors - for a variety of industrial and research uses. One of the company's newer products is a thermocouple specially designed for high accuracy at extreme temperatures above 3,000 degrees Fahrenheit. Development of sensor brought substantial increases in Weed Instrument sales and employment.
Error computation in radiosonde and rocketsonde atmospheric temperature sensors by using thermistors of different emissivities
The Doppler Wind Temperature Sensor instrument (DWTS), developed by Global Atmospheric Technologies and Sciences (GATS), is a powerful yet simple tool with the potential of becoming a new window to upper atmosphere dynamics. Based around a defense-grade infrared camera peering through a static gas cell used as a scanning spectral filter, the DWTS is designed to measure the fingerprints of wind and thermal waves as they propagate to the mesosphere and lower thermosphere. DWTS achieves this scanning by measuring the induced change in the doppler shift of the emission as it passes through the DWTS field of view. DWTS holds promise to aid in more accurate weather determination (Gordley, et al), and the core technology can be easily adapted to study other atmospheres of interest. In partnership with GATS, NOAA, and other collaborators, NASA Ames and the Nano Orbital Workshop group have been working to evaluate the DWTS instrument on orbit and optimize it as a flexible cube satellite payload. The first mission selected for DWTS evaluation is preparing for flight in early 2024, followed by a more capable science mission in 2025, with both missions part of the TES-n/NOW flight series. The first flight, TES-16/DWTS-A, will incorporate a single DWTS instrument in an approximately 2U payload volume with the imaging aperture perpendicular to the flight velocity vector. With an estimated power consumption of 20 watts, supplied via a custom NOW-designed GaN converter, the instrument will maintain the imaging sensor plane at 80K using an integrated pulse-tube cryocooler during instrument evaluation periods. Data from DWTS will be captured via a NOW-designed custom data processor before being transmitted via S-band radio back to select ground stations, with instrument command and control operated via L-band global-coverage radio. After the TES-16/DWTS-A initial demonstration mission, the subsequent TES-17/DWTS-B mission will be a dedicated science mission equipped with three DWTS instruments, each hosting a different gas cell to obtain full altitude coverage from 20 to 200 km both day and night from a single cube satellite. The intention of the flight series, and one of NASA’s interests in the instrument, is to advance a Martian atmospheric instrument (Colaprete, Gordley, et al) which, if successful, would greatly further understanding of Martian atmospheric behavior. The proposed paper will review the flight series in detail, including challenges from the TES-16 flight tests and the projected challenges and application to Mars study. Additional detail regarding the possible applications of a Cognitive Communication technique in current flight development by NOW collaborators at the NASA Glenn Research Center will also be discussed, including the implications of using an automated User Initiated Service (UIS) protocol to maximize the data collected per orbit.
Silicon-on-insulator (SOI) technology is becoming widely used in integrated circuit chips for its advantages over the conventional silicon counterpart. The decrease in leakage current combined with lower power consumption allows electronics to operate in a broader temperature range. This paper describes the performance of an SOIbased temperature sensor under extreme temperatures and thermal cycling. The sensor comprised of a temperature-to-frequency relaxation oscillator circuit utilizing an SOI precision timer chip. The circuit was evaluated under extreme temperature exposure and thermal cycling between -190 C and +210 C. The results indicate that the sensor performed well over the entire test temperature range and it was able to re-start at extreme temperatures.
This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.
Temporally continuous snow depth estimates are vital for understanding changing snow patterns and impacts on permafrost in the Arctic. We train a random forest machine learning model to predict snow depth from variability in ground surface temperature. To our knowledge, this is the first time that small ground surface temperature sensors have been used to estimate snow depth. The model performs well at sites where the model was trained and at pan-arctic evaluation sites (RMSE <= 0.15 m). Small temperature sensors are cheap and easy-to-deploy, so this technique enables spatially distributed and temporally continuous snowpack monitoring to an extent previously infeasible. The model is flexible and can be applied to datasets retroactively to retrieve snow depth estimates at additional sites. This code package includes a *.joblib file of the trained random forest model and a *.ipynb file showing how to clean input data, train the random forest model, and apply the model.
Investigate the in-pile performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-pile instrumentation. Evaluate the distributed sensing performance of the sensors through optical backscatter reflectometry under combined radiation and temperature effects, and high fluence.
Temperature measurements of Mo-Si-based thin-film resistance thermometers were studied. Annealing in an argon ambient at a temperature above 1000 C for at least 1 h is required to form the stable tetragonal MoSi2 phase. With a crack-free 2-micron-thick AlN barrier layer on top, a sensor was tested up to 1200 C. The resistivity vs temperature characteristic shows the room temperature resistivity and temperature coefficient of resistivity (TCR) of the sensor to be approximately 350 microohm and 0.01195 K, respectively. No film adhesion problems were observed for at least four testing cycles.
In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.
Described is a fiber-optic temperature sensor that uses a spectrum modulating SiC etalon. The spectral output of this type of sensor may be analyzed to obtain a temperature measurement which is largely independent of the transmission properties of the sensor's fiber-optic link. A highly precise laboratory spectrometer is described in detail, and this instrument is used to study the properties of this type of sensor. Also described are a number of different spectrum analyzers that are more suitable for use in a practical thermometer.
Described is a fiber-optic temperature sensor that uses a spectrum modulating SiC etalon. The spectral output of this type of sensor may be analyzed to obtain a temperature measurement which is largely independent of the transmission properties of the sensor's fiber-optic link. A highly precise laboratory spectrometer is described in detail, and this instrument is used to study the properties of this type of sensor. Also described are a number of different spectrum analyzers that are more suitable for use in a practical thermometer.
Performance assessment data accumulated during exposure of the digital temperature sensor to simulated shuttle flight type environments are presented. The test parameters were specifically designed to check the sensor for its: (1) ability to resolve temperature relative to the design specifications; (2) ability to maintain accuracy after interchanging the temperature probes with each electronics interface assembly; (3) stability (i.e., satisfactory operation and accuracy during and after exposure to flight environments); and (4) repeatability, or its ability to produce the same output on subsequent exposures to the identical stimulus. Equipment list, test descriptions, data summary, and conclusions are included.
A wireless temperature sensor includes an electrical conductor and a dielectric material on the conductor. The conductor is electrically unconnected and is shaped for storage of an electric field and a magnetic field. In the presence of a time-varying magnetic field, the conductor resonates to generate harmonic electric and magnetic field responses, each of which has a frequency associated therewith. The material is selected such that it experiences changes in either dielectric or magnetic permeability attributes in the presence of a temperature change. Shifts from the sensor's baseline frequency response indicate that the material has experienced a temperature change.