Light sources for remote sensing systems
Arc, incandescent, and electric discharge light sources for remote sensing systems
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Arc, incandescent, and electric discharge light sources for remote sensing systems
An ultraminiature light source using a double-spiral shaped tungsten filament includes end contact portions which are separated to allow for radial and length-wise unwinding of the spiral. The double-spiral filament is spaced relatively far apart at the end portions thereof so that contact between portions of the filament upon expansion is avoided. The light ource is made by fabricating a double-spiral ultraminiature tungsten filament from tungsten foil and housing the filament in a ceramic package having a reflective bottom and a well wherein the filament is suspended. A vacuum furnace brazing process attaches the filament to contacts of the ceramic package. Finally, a cover with a transparent window is attached onto the top of the ceramic package by solder reflow in a second vacuum furnace process to form a complete hermetically sealed package.
We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.
The duoplasmatron as a vacuum ultraviolet light source
Arc lamps and other intense light sources for solar simulation testing, and spectral reflectance of coatings
Fluorescent photography of droplets in spray using Q-switched laser as light source
Traditional office buildings use a variety of primary light sources (e.g., LED/fluorescent lights). As interest in LEED certified office buildings increase and research has shown that enhanced lighting design improves human performance and alertness (Viola et al., 2008; Juslén & Tenner, 2005; Edwards & Torcellini, 2002), more office buildings are incorporating a daylighting design. We investigated the differences between employee performance and alertness in two different building types (daylight vs. artificial light). We hypothesized that employee performance and sleep duration would be improved in a building designed to increase exposure to natural daylight compared to traditional office settings.
At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.
Vacuum spark light source for extreme UV noting mechanical trigger, compatibility with clean vacuum system and magnetic confinement of ions
The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.
The discovery of enols in combustion environments and our atmosphere has garnered increasing attention to the many unanswered questions surrounding enol chemistry. The scarcity of experimental data concerning these enols renders combustion and atmospheric models with a lack of constraining parameters, leading to varying computational predictions. Experimental detection is difficult because mass spectrometry, a powerful tool for probing a wide variety of species, cannot distinguish between enols and their thermodynamically favorable ketone isomers. A solution to this ambiguity is to use tunable vacuum ultraviolet (VUV) light from a synchrotron to identify the presence of the enol by its lower ionization energy compared to the isomer. We present a tabletop-scale VUV light source that implements highly cascaded harmonic generation, a new regime of cascaded nonlinear optics, to provide a set of spectral lines spaced by 1.2 eV. We demonstrate that the variety of photon energies available allows us to detect the keto-enol tautomerization of four aldehydes and ketones. By combining this novel VUV light source with an established microreactor, we first revisit the formation of vinyl alcohol from acetaldehyde and confirm that the observed isomerization is indeed unimolecular. Secondly, we observe the thermal tautomerization of acetone to propen-2-ol for the first time. Finally, we observe the thermal tautomerization of cyclohexanone to 1-cyclohexenol and methyl vinyl ketone to 2-hydroxybutadiene, where the results are in good agreement with those reported at a synchrotron. Furthermore, our measurements can be used to constrain models, inform future experimental studies of enol reactivity, and potentially enhance current understanding of combustion and environmental chemistry.
The synchronization of physiological and behavioral rhythms are controlled by an endogenous biological clock. It is generally accepted that environmental lighting is the strongest entrainer of this clock. The pineal gland is an important physiological transducer of environmental lighting via systemic melatonin secretion. We have used a novel light source using light emitting diode (LED) technology to entrain circadian rhythms in rats, and propose a novel percutaneous exogenous melatonin delivery system to entrain rat rhythms. We used 5 groups of Sprague-Dawley rats (175-350 g; N = 8/group) and showed normal entrainment of gross locomotor activity, feeding, and drinking circadian rhythms at light intensities varying from 80 lux to 0.1 lux (22.4 to 0.03 sq cm). To improve the delivery of melatonin across the skin stratum corneum it was formulated in a suitable vehicle in a transdermal drug delivery system. Various saturated and unsaturated fatty acids were used E, akin penetration enhancers. Our best vehicle formulation was achieved with a combination-of ethano1:water (60:40) along with 5% oleic acid as the enhancer. This formulation mixture was studied using Franz diffusion cell (0.636 sq cm diffusional area) and 1 cu cm dorsal skin isolated from Sprague Dawley rats. Our results showed that oleic acid in combination with the water ethanol mixture improved the flux of melatonin by more than 18 fold. The lag time for melatonin permeation was 2-3 hrs and the peak concentrations were achieved in 8-10 hrs. Our approaches in the future will involve the use of our transdermal melatonin delivery system and under the influence of LED light and microgravity.
Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.
Apparent movement phenomena on cathode ray tube displays - threshold determinations of apparent movements of pulsed light sources
A wide range, variable intensity light source of constant color characteristics has been developed for testing and calibrating photomultiplier tubes. A light attenuator first diffuses light from a constant source, then permits variable attenuation through a series of chambers and adjustable apertures.
The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.
Laser-shock compression experiments at 3rd and 4th generation light sources generally employ phase plates, which are inserted into the beamline to achieve a repeatable intensity distribution at the focal plane. Here, the laser intensity profile is characterized by a high-contrast, high-frequency laser speckle. Without sufficient smoothing, these laser non-uniformities can translate to a significant pressure distribution within the sample layer and can affect data interpretation in x-ray diffraction experiments. Here, we use a combination of one- and two-dimensional velocity interferometry to directly measure the extent to which spatial frequencies within the laser focal spot intensity pattern are smoothed out during propagation within the laser plasma and a polyimide ablator. We find that the use of thicker polyimide layers results in spatially smoother shock fronts, with the greatest degree of smoothing associated with the highest spatial frequencies. Focal spots with the smallest initial speckle separation produce the most rapid smoothing. Laser systems that employ smoothing by spectral dispersion techniques to rapidly modulate the focal plane intensity distribution are shown to be the most effective ones in producing a spatially smooth shock front. We show that a simple transport model combined with the known polyimide Hugoniot adequately describes the extent of shock smoothness as a function of polyimide thickness. Finally, our results provide a description of spatial structure smoothing across a shock front, which can be used to design targets on x-ray free electron laser facilities.
Aluminum alloy compounds as wide band gap semiconductors for electroluminescent light sources