Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

LANL Test Engineering’s Structural Dynamics Research and Development Efforts [Slides]

LANL's priority roles are serving as a nuclear weapons design agency and a nuclear weapons production agency; addressing nuclear threats; and performing national security science, technology, and engineering. LANL’s Test Engineering organization serves the national mission of maintaining a strategic nuclear deterrent by providing high-quality, empirical evidence through the execution and assessment of weapons system and component testing. Shock and vibration environmental testing provides one key piece of evidence for evaluation and qualification of these systems and components in the service environments incurred during a lifetime in the stockpile. LANL’s Test Engineering group continuously pursues research and development in structural dynamics to improve shock and vibration testing capabilities, processes, and analysis techniques to increase the fidelity of service environment recreations in laboratory testing settings. This talk will highlight several ongoing projects to represent these R&D efforts.

42 ENGINEERING↗

Characterization, Leaching, and Filtrations Testing of Ferrocyanide Tank sludge (Group 8) Actual Waste Composite

This is the final report in a series of eight reports defining characterization, leach, and filtration testing of a wide variety of Hanford tank waste sludges. The information generated from this series is intended to supplement the Waste Treatment and Immobilization Plant (WTP) project understanding of actual waste behaviors associated with tank waste sludge processing through the pretreatment portion of the WTP. The work described in this report presents information on a high-iron waste form, specifically the ferrocyanide tank waste sludge. Iron hydroxide has been shown to pose technical challenges during filtration processing; the ferrocyanide tank waste sludge represented a good source of the high-iron matrix to test the filtration processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SHELXT – Integrated space-group and crystal-structure determination

SHELXT automates routine small-molecule structure determination starting from single-crystal reflection data, the Laue group and a reasonable guess as to which elements might be present. The new computer program SHELXT employs a novel dual-space algorithm to solve the phase problem for single-crystal reflection data expanded to the space group P1. Missing data are taken into account and the resolution extended if necessary. All space groups in the specified Laue group are tested to find which are consistent with the P1 phases. After applying the resulting origin shifts and space-group symmetry, the solutions are subject to further dual-space recycling followed by a peak search and summation of the electron density around each peak. Elements are assigned to give the best fit to the integrated peak densities and if necessary additional elements are considered. An isotropic refinement is followed for non-centrosymmetric space groups by the calculation of a Flack parameter and, if appropriate, inversion of the structure. The structure is assembled to maximize its connectivity and centred optimally in the unit cell. SHELXT has already solved many thousand structures with a high success rate, and is optimized for multiprocessor computers. It is, however, unsuitable for severely disordered and twinned structures because it is based on the assumption that the structure consists of atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Correlation between Field Performance and Indoor Acceleration Measurements of Potential Induced Degradation (PID) for c-Si PV Modules

The correlation between outdoor field testing and indoor chamber measurement for potential-induced degradation in crystalline silicon PV modules is unclear. The motivation of this work is to build up a direct comparison and investigate the correlation between indoor and outdoor performance. First of all, four PID indoor tests were defined from basic to premium, based on the difficulty of the test. Six groups of modules were designed and fabricated in Trina Solar, with different grades of PID resistance from weak to strong. The outdoor field test systems were built in three different climates: tropical, subtropical, and semi-arid climates in Singapore, Changzhou (China) and Golden (CO, USA) respectively, in a collaborative testing campaign involving Trina, SERIS and NREL. The system in Golden has been on-sun for more than 13 months where <4% power loss which includes PID and other reliability losses was detected and power loss of <2% is shown for all six groups of modules after 21 weeks in the field in the subtropical climate in Changzhou. However, PID of 23% was observed after 18 weeks in Singapore for the most PID-susceptible module, while the other PID module types showed degradation of only less than 5%.

14 SOLAR ENERGY↗

Crush Testing at Oak Ridge National Laboratory

The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage. Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL s experiences performing crush tests on several different Type B packages.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Crush Testing at Oak Ridge National Laboratory

The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Immobilized Low-Activity Waste Transportation System Testing Results - 20043

The immobilized low-activity waste (ILAW) transportation system is a first-of-a-kind system that is being designed and tested to transport ILAW glass-filled containers from Hanford's Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility to the Integrated Disposal Facility (IDF) burial trench for permanent disposal. A prototype design and fabrication of one transport trailer and four engineered ILAW pallets was completed in mid-2018. Prototype qualification testing to verify adequacy of the design was completed in 2019 by Washington River Protection Solutions (WRPS) and affiliate ATKINS SNC-Lavalin Group. Prototype testing was completed to advance design maturation across all operational and facility interfaces, and under adverse environmental and operating conditions, including thermal assessment of the system at peak projected temperatures. Test design, observation, and feedback was well represented and supported by all ILAW Transportation System interfacing organizations: WTP constructor Bechtel National, Inc.; IDF operator CH2M (CHPRC); transportation contractor Mission Support Alliance (MSA); the U. S. Department of Energy Richland Operations Office (DOE/RL) and Office of River Protection (DOE/ORP); and Washington State Department of Ecology. This paper presents the results of prototype qualification testing and opportunities for design improvements based on testing. Changes to the final design as a result of prototype testing include improvements in safety, ergonomics, operational flexibility, and As-Low-As-Reasonably-Achievable (ALARA) applications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of Damage Inducing Impact Events in Vibration Test Fixtures Using Holder Exponents

The Shock and Vibration team within the Test Engineering group at Los Alamos National Laboratory (LANL) aids in the development and qualification of weapon systems for the United States Department of Energy (DOE). Performing tests that replicate shock and vibration environments representative of a weapon’s lifetime is critical in ensuring safety, survivability, and reliability. A key factor in shock and vibration testing is accurate representation of the weapon’s boundary conditions in its end use configuration. The boundary conditions representative of a reentry body in flight are particularly difficult to replicate on an electrodynamic shaker. When executing shock and vibration tests on a reentry body, two system axes are tested with the system in a cantilevered configuration. This cantilevered testing configuration results in a moment load being applied to the system while undergoing vibration environments. A special fixture, known as the Flex-Web, was developed to decouple this moment load from the reentry body in order to more accurately represent real world boundary conditions while replicating flight environments.

42 ENGINEERING↗

SU-F-J-217: Accurate Dose Volume Parameters Calculation for Revealing Rectum Dose-Toxicity Effect Using Deformable Registration in Cervical Cancer Brachytherapy: A Pilot Study

Purpose: To study the feasibility of employing deformable registration methods for accurate rectum dose volume parameters calculation and their potentials in revealing rectum dose-toxicity between complication and non-complication cervical cancer patients with brachytherapy treatment. Method and Materials: Data from 60 patients treated with BT including planning images, treatment plans, and follow-up clinical exam were retrospectively collected. Among them, 12 patients complained about hematochezia were further examined with colonoscopy and scored as Grade 1–3 complication (CP). Meanwhile, another 12 non-complication (NCP) patients were selected as a reference group. To seek for potential gains in rectum toxicity prediction when fractional anatomical deformations are account for, the rectum dose volume parameters D0.1/1/2cc of the selected patients were retrospectively computed by three different approaches: the simple “worstcase scenario” (WS) addition method, an intensity-based deformable image registration (DIR) algorithm-Demons, and a more accurate, recent developed local topology preserved non-rigid point matching algorithm (TOP). Statistical significance of the differences between rectum doses of the CP group and the NCP group were tested by a two-tailed t-test and results were considered to be statistically significant if p < 0.05. Results: For the D0.1cc, no statistical differences are found between the CP and NCP group in all three methods. For the D1cc, dose difference is not detected by the WS method, however, statistical differences between the two groups are observed by both Demons and TOP, and more evident in TOP. For the D2cc, the CP and NCP cases are statistically significance of the difference for all three methods but more pronounced with TOP. Conclusion: In this study, we calculated the rectum D0.1/1/2cc by simple WS addition and two DIR methods and seek for gains in rectum toxicity prediction. The results favor the claim that accurate dose deformation and summation tend to be more sensitive in unveiling the dose-toxicity relationship. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).

60 APPLIED LIFE SCIENCES↗

Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy, and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Link failure detection in a parallel computer

Methods, apparatus, and products are disclosed for link failure detection in a parallel computer including compute nodes connected in a rectangular mesh network, each pair of adjacent compute nodes in the rectangular mesh network connected together using a pair of links, that includes: assigning each compute node to either a first group or a second group such that adjacent compute nodes in the rectangular mesh network are assigned to different groups; sending, by each of the compute nodes assigned to the first group, a first test message to each adjacent compute node assigned to the second group; determining, by each of the compute nodes assigned to the second group, whether the first test message was received from each adjacent compute node assigned to the first group; and notifying a user, by each of the compute nodes assigned to the second group, whether the first test message was received.

Archer, Charles J↗

Dose-Response for Stereotactic Body Radiotherapy in Early-Stage Non-Small-Cell Lung Cancer

Purpose: To compare the efficacy of three lung stereotactic body radiotherapy (SBRT) regimens in a large institutional cohort. Methods: Between 2004 and 2009, 130 patients underwent definitive lung cancer SBRT to a single lesion at the Mallinckrodt Institute of Radiology. We delivered 18 Gy Multiplication-Sign 3 fractions for peripheral tumors (n = 111) and either 9 Gy Multiplication-Sign 5 fractions (n = 8) or 10 Gy Multiplication-Sign 5 fractions (n = 11) for tumors that were central or near critical structures. Univariate and multivariate analysis of prognostic factors was performed using the Cox proportional hazard model. Results: Median follow-up was 11, 16, and 13 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 groups, respectively. Local control statistics for Years 1 and 2 were, respectively, 75% and 50% for 9 Gy Multiplication-Sign 5, 100% and 100% for 10 Gy Multiplication-Sign 5, and 99% and 91% for 18 Gy Multiplication-Sign 3. Median overall survival was 14 months, not reached, and 34 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 treatments, respectively. No difference in local control or overall survival was found between the 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 groups on log-rank test, but both groups had improved local control and overall survival compared with 9 Gy Multiplication-Sign 5. Treatment with 9 Gy Multiplication-Sign 5 was the only independent prognostic factor for reduced local control on multivariate analysis, and increasing age, increasing tumor volume, and poor performance status predicted independently for reduced overall survival. Conclusion: Treatment regimens of 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 seem to be efficacious for lung cancer SBRT and provide superior local control and overall survival compared with 9 Gy Multiplication-Sign 5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Method of Determining Accuracy and Precision for Dosimeter Systems Using Accreditation Data

A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Temperature Age Hardening in Cast Uranium-6 wt. pct. Niobium

An investigation to determine whether cast U-6Nb would exhibit low temperature (<250°C) age hardening behavior, which has been well-documented in wrought U-6Nb, was performed using a 6 year old near-cylindrical U-6Nb casting, courtesy of AWE, UK. The casting was sectioned, and metallographic cubes and tensile bars were machined and subjected to a variety of heat treatments. Our results indicate that the cast U-6Nb has a larger grain size than wrought U-6Nb, ranging from ~200-500 μm, and that these grains are equiaxed. A significant quantity of inclusions are present at the <10 μm size range and appear to be carbides, based on their morphology (faceted) and color (dark gray). There does not appear to be significant porosity present and the few pores observed were <40 μm in size and spherical. Tensile bars (TBs) were lathe machined, solutionized, then water quenched prior to testing. A group of TBs were subjected to low temperature artificial aging heat treatments consisting of a hold at 200°C for 1 or 2h, followed by furnace cooling, all under a helium backfill. Mechanical testing confirms that cast U-6Nb TBs exhibit low temperature age hardening, with an increase in initial yield stress (Y1) of >425 MPa—a significant increase over wrought U-6Nb yield stress of 100-200 MPa for the same heat treatment. This increase is accompanied by a reduction in failure strain, which is indicative of a reduction in ductility. Modifying the heat treatment temperature and/or time may allow the properties to be tailored to the requirements. This study is intended as a preliminary investigation. Overall, this high impurity content casting exhibits a reasonable mechanical response which can be tailored in a consistent manner through low temperature heat treatment. As the result, a more comprehensive investigation of low temperature aging in cleaner cast U-6Nb, better representative of the state-of-the-art, shall be performed in FY19.

36 MATERIALS SCIENCE↗

Optimizing group structures using hierarchical division

Creating group structures with few groups that give low errors is a difficult problem in reactor analysis. In recent years, automated optimization techniques have been applied to this task. We continue this trend by applying the hierarchical division algorithm to generate optimized group structures that minimize a cost function. At each stage, the algorithm adds a single group boundary to an existing group structure, dividing one group into two to increase the resolution of the group structure. The location of the added boundary is the one that gives the lowest error over all possible new boundary locations. Our implementation requires a beginning group structure, a set of candidate new boundary locations, and a set of reference reaction rates. As a proof of concept, we used WIMS-69 as the initial group structure, XMAS-172 as the ending group structures, and a 344-group reference group structure. Testing on two simple, homogenized reactor problems, we found that hierarchical division was able to reduce the error by a factor of around 5 with an increase of only 15% in the number of groups. Because hierarchical division can get stuck in local minima, it often reaches a plateau in its error reduction capability as many groups are added. Nevertheless, we find hierarchical division has strong potential to make good group structures into great group structures at a modest increase in computational cost. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one concerned standard field, irregular entrance surface, and oblique incidence in a homogeneous PMMA phantom. The last group involved the introduction of inhomogeneities in a PMMA phantom to simulate high and low density materials such as bone and lung. Measurements in water were performed by means of cylindrical and plane-parallel ionization chambers, whereas measurements in PMMA were carried out by the use of radiochromic films. Point dose values were compared in terms of percentage difference, whereas the gamma index tool was used to perform the comparison between computed and measured dose profiles, considering different tolerances according to the test complexity. In the case of transverse scans, the agreement was searched in the plane formed by the intersection of beam axis and the profile (2D analysis), while for percentage depth dose curves, only the beam axis was explored (1D analysis). An excellent agreement was found for point dose evaluation in water (discrepancies smaller than 2%). Also the comparison between planned and measured dose profiles in homogeneous water and PMMA phantoms showed good results (agreement within 2%-2 mm). Profile evaluation in phantoms with internal inhomogeneities showed a good agreement in the case of ''lung'' insert, while in tests concerning a small ''bone'' inhomogeneity, a discrepancy was particularly evidenced in dose values on the beam axis. This is due to the inaccurate geometrical description of the phantom that is linked to the calculation voxel size, a feature over which the user has no control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Irradiation-Assisted Stress Corrosion Cracking of Austenitic Stainless Steels in BWR Environments

The internal components of light water reactors are exposed to high-energy neutron irradiation and high-temperature reactor coolant. The exposure to neutron irradiation increases the susceptibility of austenitic stainless steels (SSs) to stress corrosion cracking (SCC) because of the elevated corrosion potential of the reactor coolant and the introduction of new embrittlement mechanisms through radiation damage. Various nonsensitized SSs and nickel alloys have been found to be prone to intergranular cracking after extended neutron exposure. Such cracks have been seen in a number of internal components in boiling water reactors (BWRs). The elevated susceptibility to SCC in irradiated materials, commonly referred to as irradiation-assisted stress corrosion cracking (IASCC), is a complex phenomenon that involves simultaneous actions of irradiation, stress, and corrosion. In recent years, as nuclear power plants have aged and irradiation dose increased, IASCC has become an increasingly important issue. Post-irradiation crack growth rate and fracture toughness tests have been performed to provide data and technical support for the NRC to address various issues related to aging degradation of reactor-core internal structures and components. This report summarizes the results of the last group of tests on compact tension specimens from the Halden-II irradiation. The IASCC susceptibility of austenitic SSs and heat-affected-zone (HAZ) materials sectioned from submerged arc and shielded metal arc welds was evaluated by conducting crack growth rate and fracture toughness tests in a simulated BWR environment. The fracture and cracking behavior of HAZ materials, thermally sensitized SSs and grain-boundary engineered SSs was investigated at several doses (≤3 dpa). These latest results were combined with previous results from Halden-I and II irradiations to analyze the effects of neutron dose, water chemistry, alloy compositions, and welding and processing conditions on IASCC. The effect of neutron irradiation on the fracture toughness of austenitic SSs was also evaluated at dose levels relevant to BWR internals.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗