Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency response control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

PV-Fed Smart Inverters for Mitigation of Voltage and Frequency Fluctuations in Islanded Microgrids

The presence of low-inertia distributed generation (DG) units makes islanded microgrids vulnerable to voltage and frequency variations. Besides, the considerable difference between the inertia of synchronous-based and inverter-based DGs results in a power imbalance between supply and demand during abnormal conditions. As a result, both voltage and frequency of microgrid ac-bus start oscillating which might have severe consequences such as blackouts. This paper deploys the traditional controller of photovoltaic (PV) units to improve the dynamic behavior of islanded microgrids by suppressing the voltage and frequency fluctuations. To this end, an adaptive piecewise droop (APD) characteristic is proposed and employed in PV units to attain a faster balance between generation and consumption during transients, leading to an enhanced frequency response. Besides, the reactive-power control loop is equipped with a droop characteristic which enables the PV units to inject/absorb reactive power during transients and participate in voltage-profile enhancement of the system. Case study results are presented using PSCAD/EMTDC to confirm the validity of proposed method in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗

Power System Frequency Dynamics Modeling, State Estimation, and Control using Neural Ordinary Differential Equations (NODEs) and Soft Actor-Critic (SAC) Machine Learning Approaches

With the global energy transition of the electric power system, grid control, supervision, and protection is becoming more challenging. With the increasing integration of renewable energy sources (RES), the system dynamics are changing, causing traditional power system dynamic modeling with swing equation-based modeling approaches to fail. Additionally, the converter-dominated power grid is decreasing the system inertia, making the power system more fragile to the frequency swings. This paper first investigates and compares the application of a model-based Kalman filter state estimation approach with (i) a model-free machine learning approach --- neural ordinary differential equations (NODEs) --- and (ii) a data-driven system identification (SysId) approach to model and infer critical state values of the power system frequency dynamics. Then a model predictive control (MPC) framework is compared to a model-free Soft Actor-Critic (SAC) reinforcement learning (RL) control algorithm in providing efficient fast frequency response (FFR) to the power system frequency dynamics. The approaches are compared in terms of their performance goals as well as their per-timestep computational efficiency. Furthermore, the comparative study for state estimation shows that for the model-free requirement, both NODEs and SysId can provide accurate state estimates; however, with increasing model complexity, NODEs can be a better choice for model identification. Similarly, the results from the FFR comparative study show that the SAC RL-based FFR, once trained, outperforms MPC with better control signals and faster computation time, making the SAC RL-based FFR better option for providing FFR to the power system.

97 MATHEMATICS AND COMPUTING↗

Frequency Shaping Control for Weakly-Coupled Grid-Forming IBRs

Here, we consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Grid Frequency Support from Distributed Energy Resources

This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scaling up carboxylic acid production from cheese whey and brewery wastewater via methane-arrested anaerobic digestion

In a circular economy, organic waste streams are valuable resources for sustainably producing chemicals and fuels. This study investigates a new methane-arrested anaerobic digestion (MAAD) process that converts high-strength cheese whey and brewery wastewater into carboxylic acids. The process was developed and optimized under various bench-scale semi-continuous (fed-batch) operating conditions (e.g., retention time, organic loading rate, pH, and feed/harvest frequency). The MAAD responses to various control-failure scenarios were also systematically investigated. The highest total acid productivity was 26g/(L liq ·d) with a substrate conversion of 0.79g COD digested /g COD fed at a hydraulic retention time (HRT) of approximately 2 d in a 14-L digester. The most stable conditions for digester operation (HRT 3 d at pH 6.0 and 40°C) were selected for process scale-up to 100gal (~380 L). Semi-continuous, pilot-scale MAAD successfully produced a total acid concentration of 40.6+/-1.1 g/L with 8.1% acetic acid, 45.1% butyric acid, and 44.5% lactic acid. The links between wastewater characteristics, operation mode, digester scale, and microbial community structure were statistically analyzed. The results show genera Sporolactobacillus and Clostridium positively correlate with butyric acid production (Pearson correlation coefficient>0.5). Moreover, four kinetic models were developed and fit to batch MAAD experimental datasets (R 2 >95%) and were successfully applied to predict the total acid production in both bench-and pilot-scale semi-continuous MAADs. In conclusion, this study shows MAAD has the potential for industrial-scale applications and is a robust platform to valorize low- or negative-value waste streams into high-value bioproducts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Model Based Predictive Control for Frequency Support in Multi-port Autonomous Reconfigurable Solar Plants

Primary frequency support functionality can be an added advantage for any new grid integrated power electronics resource. With increased penetration of power electronics resources, inertial and primary frequency response capabilities are decreasing. In this research paper, an advanced model-based predictive control (MBPC) algorithm for providing frequency support to a new topology of integrated photovoltaic(PV), batterybased energy storage systems (ESS), and high-voltage direct current (HV dc) systems called multi-port autonomus reconfigurable solar (MARS) plants is based on the synchronverter-based control. The simulation of MARS-HV dc system with proposed control strategy is simulated and validated for MARS connected to low short circuit ratio (SCR) grids in PSCAD/EMTDC simulation environment. The control algorithm proposed showcases better performance in terms of frequency nadir improvement and frequency steady state improvemnt with respect to no frequency control.

Marthi, Phani Ratna Vanamali↗

Adaptive PV Frequency Control Strategy Based on Real-time Inertia Estimation

The declining cost of solar Photovoltaics (PV) generation is driving its worldwide deployment. As conventional generation with large rotating masses is being replaced by renewable energy such as PV, the power system’s inertia will be affected. As a result, the system’s frequency may vary more dramatically in the case of a disturbance, and the frequency nadir may be low enough to trigger protection relays such as under-frequency load shedding. The existing frequency-watt function mandated in power inverters cannot provide grid frequency support in a loss-of-generation event, as PV plants usually do not have power reserves. Here, a novel adaptive PV frequency control strategy is proposed to reserve the minimum power required for grid frequency support. A machine learning model is trained to predict system frequency response under varying system conditions, and an adaptive allocation of PV headroom reserves is made based on the machine learning model as well as real-time system conditions including inertia. Case studies show the proposed control method meets the frequency nadir requirements using minimal power reserves compared to a fixed headroom control approach.

14 SOLAR ENERGY↗

Parametric Comparative Analysis between Virtual Synchronous Generator and Droop-based Inertia for Inverter-Based Microgrids

This paper presents a parametric comparative analysis between the virtual synchronous generator (VSG) method and the droop control method to emulate inertia in the voltage-source inverter (VSI). Droop controllers are commonly used to regulate sharing power in microgrids and distribute power generation proportionally among VSI’s depending on their rated power. Additionally, VSG has been used to regulate the Rate-of-Change-of-Frequency (RoCoF) of the microgrid using virtual inertia. Although both methods can be used to regulate the frequency variation, the influence of each method on the closed loop eigenvalues is not the same. In this work, the transient response of the frequency is analyzed for each method to determine their advantages and disadvantages regarding frequency regulation in microgrid applications. The results were verified by conducting experimental trials using VSI’s. These experiments demonstrated that VSG is more suitable for regulating RoCoF and frequency nadir than droop controllers since it provides inertial support and improves frequency response.

Campo-Ossa, Daniel D.↗

Experimental Evidence on Latency in a Fleet of Controllable Water Heaters

Demand response is an important emerging part of smart grids with wide coverage in theoretical and modeling research. However, experimental evidence on the real-life behavior of controllable loads is still limited. We present observations regarding latency and communication aspects of the operation on a fleet of residential water heaters in a smart neighborhood in Atlanta, GA. Our analysis shows that latency in water heaters is not constant and does not follow a Gaussian distribution. We also find that there is a systematic relationship between latency and hour of the day. Latency was found to increase during morning and evening hours compared to the afternoon. These findings could help better plan deployment of control for demand response programs. Understanding delays associated with controlling smart devices is crucial for proper design and algorithm development for optimization, frequency of dispatch, and override detection.

communication delay↗