A ventilator that responds to outdoor conditions for ventilation and air filtration
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Advanced composite materials with multiple phases and heterogeneous microstructure necessitate spatial mapping characterization of elastic modulus to develop constitutive relations and overall mechanical response. Such modulus mapping can be obtained using the nanoindentation technique, where the indenter tip raster over the selected microstructure region. Typically, a surface preparation procedure is done in the specimens to ensure proper contact between the indenter tip and sample surface. However, a near-perfect surface finish is unachievable in heterogeneous materials, primarily with ceramic reinforcements, due to the differential material removal rate during polishing. Thus, the nanoindenter records localized erroneous measurements due to differences in surface roughness and corresponding force response. This study establishes a novel deep learning-based strategy to rectify incorrect experimental spatial measurements acquire during nanoindentation modulus mapping. Here, the integrated bicubic interpolation and generative adversarial networks (GANs) model was trained using 14 ceramic and 18 metallic data sets, each comprising 65,536 measurements. The developed algorithm was validated against experimental measurements on four unknown specimens. The standard deviation in measured elastic modulus reduces by ~50% in ceramics and ~72% in metallic samples. This computational framework proposes a novel approach to reducing uncertainty in materials’ properties using state-of-the-art computer vision techniques.
Not provided.
Explore the source record for details and available documents.
Abstract Municipal drinking water distribution systems (DWDSs) and associated premise plumbing (PP) systems are vulnerable to proliferation of opportunistic pathogens, even when chemical disinfection residuals are present, thus presenting a public health risk. Monitoring the structure of microbial communities of drinking water is challenging because of limited continuous access to faucets, pipes, and storage tanks. We propose a scalable household sampling method, which uses spent activated carbon and reverse osmosis (RO) membrane point-of-use (POU) filters to evaluate mid- to long-term occurrence of microorganisms in PP systems that are relevant to consumer exposure. As a proof of concept, POU filter microbiomes were collected from four different locations and analyzed with 16S rRNA gene amplicon sequencing. The analyses revealed distinct microbial communities, with occasional detection of potential pathogens. The findings highlight the importance of local, and if possible, continuous monitoring within and across distribution systems. The continuous operation of POU filters offers an advantage in capturing species that may be missed by instantaneous sampling methods. We suggest that water utilities, public institutions, and regulatory agencies take advantage of end-of-life POU filters for microbial monitoring. This approach can be easily implemented to ensure drinking water safety, especially from microbes of emerging concerns; e.g., pathogenic Legionella and Mycobacterium species.
In the development of next-generation electronics and energy devices, intercalation compounds of transition metal dichalcogenides (TMDCs) are gaining attention for their unique properties that result from synergistic interactions between guest species and host materials. Nowadays, intercalation compounds of MoS 2 and WS 2 are commonly prepared by a two-step process: (1) exfoliation to form single-layer and/or few-layer nanosheets and (2) restacking the nanosheets with the guest species by vigorously mixing the exfoliated suspension with the solution of guest species. While a wide variety of intercalation compounds have been synthesized using this approach, the intercalation process is often timeconsuming, and the product slurry limits material quality and impedes characterization and applications. Herein, we report a versatile method for preparing intercalated TMDCs in a thin-film morphology. Using this approach, we successfully prepared a range of existing intercalation compounds of MoS 2 and WS 2 (e.g., ferrocene and amine intercalated MoS 2 and WS 2 ). Additionally, by leveraging the versatility of this intercalation method, we report we intercalated phenazine and benzoquinone into MoS 2 and WS 2 for the first time.
Nanopores in thin membranes play important roles in science and industry.
Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.
Abstract not provided.
Approximately 9 liters of supernatant from Hanford waste tank 241-AP-105 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The as-received AP-105 waste was diluted with process water (Columbia River water) from approximately 8.7 M sodium (nominal tank concentration) and partitioned into a batch of 7 M sodium and a batch of 5.5 M sodium. Dilution increased the combined volume of the two batches to approximately 7.8 liters of 7 M Na feed and 4.4 liters of 5.5 M Na feed.
A full dataset of aged nitroplasticizer (NP) is composed of more than 2000 unique mass-to-charges (m/z) when combining the non-targeted data obtained from both positive and negative electrospray ionization modes in time-of-flight mass spectrometry. Therefore, manual processing of these data often takes days, weeks, or even months to scrutinize for mechanistic insights. To effectively extract meaningful signals that represent vital degradation intermediates in the early NP degradation mechanism, a semi-automated postprocessing workflow for data filtering, tailored to the aging experiment of NP, has been developed. The automated portion of this workflow is written in a Python code (using pandas, numpy, and matplotlib libraries), which removes more than 65% of potential false signals within seconds via four threshold-based adjustable filters: signal sensitivity, coefficient of variation, number of measurements, and retention time variability. As for the manual portion, a pattern-based inspection method is employed to reduce another 23% or more false positives, which greatly simplifies data visualization and results in less than 3% of potential candidate m/z needing in-depth data interpretation. As a positive control, known compounds are verified. Using this semi-automated data reduction method, the amount of time required is reduced to a matter of hours for data filtering in the non-targeted datasets of aged NP, which saves more time and effort for compound identification.
Deep-sea microbiomes sampled with traditional or pressure-retaining instrumentation A fundamental property of life in the sea is that with increasing depth must come increased adaptation to elevated hydrostatic pressures. This project aims to assess technology for the accurate characterization of microbial biodiversity and biochemistry at greater depths, and validate its use in some of the deepest and least-explored waters in the Ocean: Hadal Trench. Compared to the 0.1 megapascal (MPa) of surface waters, organisms inhabiting at the average depth of the Ocean (3800 m) have to deal with pressures of 38 MPa (5,500 psi). The effects of these high pressure have been most thoroughly investigated in microorganisms, where it has been found to affect membrane integrity and transport, cytoskeletal assembly and both DNA and protein synthesis. We will explore the diversity and activity of microorganisms from 2000 m to >8,000 m depths within the highly productive water column of hadal trenches, comparing seawater samples obtained with and without substantial pressure changes during recovery. A pressure retaining device was used to sample the microbial communities of the watercolumn with reduced decompression during retreival (Peoples et. al., 2019). References: Peoples LM, Norenberg M, Price D, McGoldrick M, Novotny M, Bochdansky A, Bartlett DH. A full-ocean-depth rated modular lander and pressure-retaining sampler capable of collecting hadal-endemic microbes under in situ conditions. Deep Sea Research Part I: Oceanographic Research Papers. 2019 Jan 1;143:50-7.
A membrane assembly is provided. The membrane assembly includes a non-metallic, porous substrate. A graphene oxide membrane is formed over the non-metallic, porous substrate. A chemical linker interface covalently binds the graphene oxide membrane to the non-metallic, porous substrate.
Abstract not provided.
Abstract not provided.
The present disclosure relates to a device that includes a filter element and a catalyst, where the filter element is configured to remove particulate from a stream that includes at least one of a gas and/or a vapor to form a filtered stream of the gas and/or the vapor, the catalyst is configured to receive the filtered stream and react a compound in the filtered stream to form an upgraded stream of the gas and/or the vapor, further including an upgraded compound, and both the filter element and the catalyst are configured to be substantially stable at temperatures up to about 500° C.
Explore the source record for details and available documents.