Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic prognostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

65 records · Page 4

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), and 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit for MF and SS patients receiving conventional dose. Low-dose TSEB regimens are well tolerated and achieve short-term palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potentially Curative Radiotherapy for Non-Small-Cell Lung Cancer in Norway: A Population-Based Study of Survival

Purpose: The efficacy of curative irradiation in the treatment of non-small-cell lung cancer patients is considered limited. The purpose of this study was to evaluate long-term survival in a population-based approach. Methods and Materials: Cases of non-small-cell lung cancer diagnosed from 1993 to 2001 were identified in the Cancer Registry of Norway. Electronic linkage with national data from the hospitals' radiotherapy verification systems identified those who received potentially curative doses ({>=}50 Gy). Hospital records were reviewed for all patients. Results: A total of 497 patients (336 men) were identified with a radiation dose of {>=}50 Gy delivered to the lung region. Of these, 41% received 60 Gy or more. The majority (70%) of patients included had advanced stage disease: 24% Stage IIIA and 46% Stage IIIB. The overall 1-, 3-, and 5-year observed survival rates were 53%, 16%, and 9%, respectively. Multivariable analyses identified stage and chemotherapy, but not radiation dose, as significant independent prognostic variables for survival. However, 68% of patients treated with chemotherapy participated in prospective studies with inclusion criteria that excluded patients with less favorable prognostic factors, leading to a selection bias. The number of fractions and the radiation doses varied widely among different hospitals. Conclusion: The long-term prognosis after radiation therapy is poor. More sophisticated, targeted, and uniform delivery of radiation therapy is needed. The apparent benefit of chemotherapy may in part be due to selection of patients with more favorable prognostic factors for this therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Half-Bridge On-State Voltage Sensor for In-Situ Measurements

Current prognostics for life expectancy of power semiconductors utilize off-line measurements of the on-state resistance. Presented is a half-bridge (HB) on-state voltage (VON) sensor capable of being utilized for in-situ measurements enabling continuous and real-time monitoring of the on-state resistance. The design provides a single VON measurement output that contains independent VON information of both high and low side devices in a HB leg. The measurement output is referenced from the middle point of the HB and combines the two complementary VON sensing outputs. This system reduces the number of components, required number of analog signal processing circuits, and ADC channels for in-situ health monitoring of a power electronics system. These reductions will facilitate integration of the VON sensor with the gate driver board and achieve low system profile. The experimental results demonstrate the proposed VON measurements while switching with inductive and resistive loads.

Roy, Chondon↗

Power electronics reliability analysis.

This report provides the DOE and industry with a general process for analyzing power electronics reliability. The analysis can help with understanding the main causes of failures, downtime, and cost and how to reduce them. One approach is to collect field maintenance data and use it directly to calculate reliability metrics related to each cause. Another approach is to model the functional structure of the equipment using a fault tree to derive system reliability from component reliability. Analysis of a fictitious device demonstrates the latter process. Optimization can use the resulting baseline model to decide how to improve reliability and/or lower costs. It is recommended that both electric utilities and equipment manufacturers make provisions to collect and share data in order to lay the groundwork for improving reliability into the future. Reliability analysis helps guide reliability improvements in hardware and software technology including condition monitoring and prognostics and health management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Is Elective Irradiation to the Lower Neck Necessary for N0 Nasopharyngeal Carcinoma?

Purpose: To summarize our experience and treatment results in lymph node-negative nasopharyngeal carcinoma treated in a single institution. Methods and Materials: From January 2000 to December 2003, 410 patients with lymph node-negative nasopharyngeal carcinoma were retrospectively analyzed. The T-stage distribution was 18.8% in T1, 54.6% in T2 (T2a, 41 patients; T2b, 183 patients), 13.2% in T3, and 13.4% in T4. All patients received radiotherapy to the nasopharynx, skull base, and upper neck drainage areas, including levels II, III, and VA. The dose was 64-74 Gy, 1. 8-2.0 Gy per fraction over 6.5-7.5 weeks to the primary tumor with {sup 60}Co or 6-MV X-rays, and 50-56 Gy to levels II, III, and VA. Residual disease was boosted with either {sup 192}Ir afterloading brachytherapy or small external beam fields. Results: The median follow-up time was 54 months (range, 3-90 months). Four patients developed neck recurrence, and only 1 patient (0.2%) experienced relapse outside the irradiation fields. The 5-year overall survival rate was 84.2%. The 5-year relapse-free survival rate, distant metastasis-free survival rate, and disease-free survival rate were 88.6%, 90.6% and 80.1%, respectively. Both univariate and multivariate analyses demonstrated that T classification was the only significant prognostic factor for predicting overall survival. The observed serious late toxicities were radiation-induced brain damage (7 cases), cranial nerve palsy (16 cases), and severe trismus (13 cases; the distance between the incisors was {<=}1 cm). Conclusion: Elective levels II, III, and VA irradiation is suitable for nasopharyngeal carcinoma without neck lymph node metastasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternative Dose for Choroidal Melanoma Treated With an Iodine-125 Radioactive Plaque: A Single-Institution Retrospective Study

Purpose: The Collaborative Ocular Melanoma Study (COMS) established iodine-125 plaque brachytherapy as an accepted standard treatment for medium-size choroidal melanoma. In the COMS, the prescription dose was 85 Gy. This is a retrospective review of our outcomes in patients treated with lower doses than those used in the COMS. Methods and Materials: From 1990 to 2004, 62 patients were treated with iodine-125 plaque brachytherapy for choroidal melanoma. COMS eye plaques were used with dose prescribed to the apex of the tumor. The median and average dose rates at the tumor apex were 63.5 cGy/h and 62.7 cGy/h, respectively. The median and average total doses were 63.0 Gy and 62.5 Gy (range, 56-69 Gy), respectively. The median and mean durations of implant were 100.0 hours and 101.1 hours (range, 71-165 hours). Results: Median follow-up time was 58.2 months. The 5-year outcomes including overall survival, disease-free survival, cause-specific survival, local failure, secondary enucleation rate, and visual acuity (VA) <20/200 were estimated using the Kaplan-Meier method. Overall, there were 7 local failures, 4 distant failures, and 10 secondary enucleations (6 due to local failure and 4 due to treatment complications). Univariate analysis was performed to identify significant prognostic factors associated with disease-free survival (baseline VA in tumor eye, tumor shape), cause-specific survival (diabetic retinopathy), local failure (none found), secondary enucleation rate (diabetic retinopathy, basal tumor dimension) and VA <20/200 (diabetic retinopathy, tumor shape, age, retinal detachment, treatment depth, and history of vision-limiting condition). Conclusions: Our survival and local control outcomes are comparable to those of the COMS. However, VA at 5 years seems to be better. Lower doses of radiation could potentially lead to better visual outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Hierarchical Control Architecture for a PEBB-Based ILC Marx Modulator

The idea of building power conversion systems around Power Electronic Building Blocks (PEBBs) was initiated by the U.S. Office of Naval Research in the mid 1990s. A PEBB-based design approach is advantageous in terms of power density, modularity, reliability, and serviceability. It is obvious that this approach has much appeal for pulsed power conversion including the International Linear Collider (ILC) klystron modulator application. A hierarchical control architecture has the inherent capability to support the integration of PEBBs. This has already been successfully demonstrated in a number of industrial applications in the recent past. This paper outlines the underlying concepts of a hierarchical control architecture for a PEBB-based Marx-topology ILC klystron modulator. The control in PEBB-based power conversion systems can be functionally partitioned into (three) hierarchical layers; system layer, application layer, and PEBB layer. This has been adopted here. Based on such a hierarchical partition, the interfaces are clearly identified and defined and, consequently, are easily characterised. A conceptual design of the hardware manager, executing low-level hardware oriented tasks, is detailed. In addition, the idea of prognostics is briefly discussed.

43 PARTICLE ACCELERATORS↗

Challenges and needs for system-level electrochemical lithium-ion battery management and diagnostics

The desire for energy-dense and fast-charged battery technology in consumer-electronics, electric-vehicle, grid, and aviation applications is pushing the envelope on materials to cells and pack designs to use and operating conditions. However, some approaches could inherently decrease safety of the battery—thus requiring the development of advanced management and diagnostics. Safety of lithium-ion batteries (LiBs), particularly in multicell configurations, is highly variable and could evolve with use. Existing works primarily focus on cell life and safety diagnostics without considering module and pack-level uncertainties and sometimes imply that cell-level electrochemical diagnostics would work in modules or packs, a naive oversimplification. Using example case studies, we highlight the potential and challenges associated with extending single-cell diagnostics to multiple cells, note the challenge involved, and motivate the research and development and support communities to devote efforts to fill the gap by developing diagnostics at these levels for current- and future-generation LiBs.

25 ENERGY STORAGE↗

Fifteen-Year Biochemical Relapse-Free Survival, Cause-Specific Survival, and Overall Survival Following I{sup 125} Prostate Brachytherapy in Clinically Localized Prostate Cancer: Seattle Experience

Purpose: To report 15-year biochemical relapse-free survival (BRFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with I{sup 125} brachytherapy monotherapy for clinically localized prostate cancer early in the Seattle experience. Methods and Materials: Two hundred fifteen patients with clinically localized prostate cancer were consecutively treated from 1988 to 1992 with I{sup 125} monotherapy. They were prospectively followed as a tight cohort. They were evaluated for BRFS, CSS, and OS. Multivariate analysis was used to evaluate outcomes by pretreatment clinical prognostic factors. BRFS was analyzed by the Phoenix (nadir + 2 ng/mL) definition. CSS and OS were evaluated by chart review, death certificates, and referring physician follow-up notes. Gleason scoring was performed by general pathologists at a community hospital in Seattle. Time to biochemical failure (BF) was calculated and compared by Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire cohort was 80.4%. BRFS by D'Amico risk group classification cohort analysis was 85.9%, 79.9%, and 62.2% for low, intermediate, and high-risk patients, respectively. Follow-up ranged from 3.6 to 18.4 years; median follow-up was 15.4 years for biochemically free of disease patients. Overall median follow-up was 11.7 years. The median time to BF in those who failed was 5.1 years. CSS was 84%. OS was 37.1%. Average age at time of treatment was 70 years. There was no significant difference in BRFS between low and intermediate risk groups. Conclusion: I{sup 125} monotherapy results in excellent 15-year BRFS and CSS, especially when taking into account the era of treatment effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating cavity fault prediction using deep learning at Jefferson Laboratory

Abstract Accelerating cavities are an integral part of the continuous electron beam accelerator facility (CEBAF) at Jefferson Laboratory. When any of the over 400 cavities in CEBAF experiences a fault, it disrupts beam delivery to experimental user halls. In this study, we propose the use of a deep learning model to predict slowly developing cavity faults. By utilizing pre-fault signals, we train a long short-term memory-convolutional neural network binary classifier to distinguish between radio-frequency (RF) signals during normal operation and RF signals indicative of impending faults. We optimize the model by adjusting the fault confidence threshold and implementing a multiple consecutive window criterion to identify fault events, ensuring a low false positive rate. Results obtained from analysis of a real dataset collected from the accelerating cavities simulating a deployed scenario demonstrate the model’s ability to identify normal signals with 99.99% accuracy and correctly predict 80% of slowly developing faults. Notably, these achievements were achieved in the context of a highly imbalanced dataset, and fault predictions were made several hundred milliseconds before the onset of the fault. Anticipating faults enables preemptive measures to improve operational efficiency by preventing or mitigating their occurrence.

43 PARTICLE ACCELERATORS↗