Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Microwave holography of large reflector antennas - Simulation algorithms

The performance of large reflector antennas can be improved by identifying the location and amount of their surface distortions and correcting them. To determine the accuracy of the constructed surface profiles, simulation studies are used to incorporate both the effects of systematic and random distortions, particularly the effects of the displaced surface panels. In this paper, different simulation models are investigated, emphasizing a model based on the vector diffraction analysis of a curved reflector with displaced panels. The simulated far-field patterns are then used to reconstruct the location and amount of displacement of the surface panels by employing a fast Fourier transform/iterative procedure. The sensitivity of the microwave holography technique based on the number of far-field sampled points, level of distortions, polarizations, illumination tapers, etc., is also examined.

Rahmat-Samii, Y.↗

Application of a recursive distortion estimator to the geodetic correction of thematic mapper imagery

It is pointed out that the higher resolution provided by the Thematic Mapper increases the demands on the accuracy needed by the ground processing in correcting for geodetic errors deriving from internal misalignments and uncertainties in the knowledge of spacecraft ephemeris and attitude. In addition, the Thematic Mapper will also process longer imagery intervals than previous missions. The recursive distortion estimator to be used is a Kalman filter. Here, a minimum variance spacecraft state error vector is estimated for known initial covariance of the elements of that vector and known image noise. Tests of the recursive distortion estimator with various spacecraft models carried out using a simulation of real world state vector dynamics are described. A determination is made of the density of control points needed to meet specified geometric correction requirements; it is expressed as a function of imagery interval length and control point measurement error.

Arnold, P.↗

Echelle spectra image processing for the International Ultraviolet Explorer

This paper presents the techniques needed to convert the International Ultraviolet Explorer (IUE) high-resolution echelle spectra into useful scientific data. The image is obtained with a digitally controlled vidicon camera system. The processes that must be carried out on the image include: noise removal, correction for geometric and optical distortion, nonuniform photometric corrections, and two-dimensional wavelength determination. Results from the breadboard camera system are presented.

Klinglesmith, D. A.↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

In vivo volumetric imaging of calcium and glutamate activity at synapses with high spatiotemporal resolution

Studying neuronal activity at synapses requires high spatiotemporal resolution. For high spatial resolution in vivo imaging at depth, adaptive optics (AO) is required to correct sample-induced aberrations. To improve temporal resolution, Bessel focus has been combined with two-photon fluorescence microscopy (2PFM) for fast volumetric imaging at subcellular lateral resolution. To achieve both high-spatial and high-temporal resolution at depth, we develop an efficient AO method that corrects the distorted wavefront of Bessel focus at the objective focal plane and recovers diffraction-limited imaging performance. Applying AO Bessel focus scanning 2PFM to volumetric imaging of zebrafish larval and mouse brains down to 500 µm depth, we demonstrate substantial improvements in the sensitivity and resolution of structural and functional measurements of synapses in vivo. This enables volumetric measurements of synaptic calcium and glutamate activity at high accuracy, including the simultaneous recording of glutamate activity of apical and basal dendritic spines in the mouse cortex.

59 BASIC BIOLOGICAL SCIENCES↗

Geometric Interpretation of the Cluster Location Problem Part I: Theory

We present a new framing of the seismic location problem using principles drawn from differential geometry. Our interpretation relies upon the common assumption that travel times observed across a network are continuous, differentiable functions of source location. In consequence, travel‐time functions constitute a differentiable map between the source region and a Riemannian manifold. The manifold is said to be the image of the source region embedded in a generally high‐dimension travel‐time vector space. A cluster of events in the source region has an image of discrete points on the manifold, that, except in the simplest cases, cannot be viewed directly. However, it is possible to project the image of a cluster into a tangent space of the manifold for direct visualization. The projection operator can be computed directly from the data without a velocity model, but produces a distorted rendering of the cluster geometry. With a model we can predict the distortions and correct them to estimate cluster geometry. We develop these points with the simplest possible example, one for which direct visualization of the manifold is possible, using the example as an introduction to the relevant concepts from differential geometry in a familiar setting. The tangent space, a local linearization of the manifold, plays a key role. We develop a metric to estimate the limits of linearization, that is, to determine when the curvature of the manifold invalidates the linear assumption. We also examine the interplay of model error, inadequate network geometry, and pick error. We then generalize our results from the simple case to the general case of 3D source regions observed by general networks. Although we do suggest a new “project and correct” method for location, we do not develop it into a practical algorithm. In conclusion, our intention rather is to highlight new analytical methods grounded in differential geometry.

East Pacific Ocean Islands↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Digital computer processing of X-ray photos

Digital computers correct various distortions in medical and biological photographs. One of the principal methods of computer enhancement involves the use of a two-dimensional digital filter to modify the frequency spectrum of the picture. Another computer processing method is image subtraction.

Nathan, R.↗

Integral image tube-optical systems for the far UV.

Description of proposed image tube optical systems for narrow-band direct photography and broad bandpass photography from spacecraft outside the atmosphere. For narrow-band photography an f/1.5 Schmidt camera with a photocathode located on the focal surface is recommended. The photoelectrons are accelerated and magnetically focused onto a phosphor/fiber optics surface, the curvature of which partially corrects for distortions of the electric field introduced by the curved photocathode. The second stage can be any other tube, electrostatically or magnetically focused, having a fiber optics faceplate butted to the first stage. For broad bandpass a spectrograph with an f/3 all-reflecting Schmidt image tube camera is recommended.

Chincarini, G.↗

Angiographic analysis of heart geometry.

Basic steps in the acquisition and reconstruction of cardiac dimensions obtained from angiocardiograms for spatial reconstruction and analysis are described, and example applications include a reconstruction of the human left ventricle and a study of the motion of the free wall of the right ventricle in a dog. Computer analysis of the spatial motion of implanted tantalum markers is discussed along with corrections for distortion and magnification incurred in the process. Graphics display of three-dimensional ventricle models is examined, and future improvements in angiocardiographic studies are considered.

Sandler, H.↗

Study of Synthetic Aperture Radar (SAR) imagery characteristics

Sources of geometric and radiometric fidelity errors in AN/APQ-102A radar imagery are discussed, along with a digital computer program to correct the distortions. The major effort, a computer program which will process digitalized recorded AN/APQ-102A phase histories into imagery, is described. All computer programs are listed.

Source record↗

Mariner 6 and 7 picture analysis

Analysis of Mariner 6 and 7 far-encounter (FE) pictures is discussed. The purpose of the studies was to devise ways to combine digital data from the full set of FE pictures so as to improve surface resolution, distinguish clouds and haze patches from permanent surface topographic markings, deduce improved values for radius, oblateness, and spin-axis orientation, and produce a composite photographic map of Mars. Attempts to measure and correct camera distortions, locate each image in the frame, and convert image coordinates to martian surface coordinates were highly successful; residual uncertainties in location were considerably less than one pixel. However, analysis of the data to improve the radius, figure, and axial tilt and to produce a composite map was curtailed because of the superior data provided by Mariner 9. The data, programs, and intermediate results are still available (1976), and the project could be resumed with little difficulty.

Leighton, R. B.↗

Extraction of quadrature phase information from multiple pulse NMR signals

A multiple pulse sequence (8-pulse sequence) used for high-resolution solid state NMR is analyzed with regard to the information available from each of the four wide sampling windows. It is demonstrated that full quadrature phase information can be obtained using only a single phase detector and that, for the commonly encountered situation where the spectral width is much less than the folding frequency, the signals from the various windows can be combined easily using standard complex Fourier transform software. An improvement in the signal-to-noise ratio equal to the square root of 3 is obtained over either standard single or quadrature phase detection schemes. Procedures for correcting spectral distortions are presented.

Rhim, W.-K.↗

A 'digital' technique for manual extraction of data from aerial photography

The interpretation procedure described uses a grid cell approach. In addition, a random point is located in each cell. The procedure required that the cell/point grid be established on a base map, and identical grids be made to precisely match the scale of the photographic frames. The grid is then positioned on the photography by visual alignment to obvious features. Several alignments on one frame are sometimes required to make a precise match of all points to be interpreted. This system inherently corrects for distortions in the photography. Interpretation is then done cell by cell. In order to meet the time constraints, first order interpretation should be maintained. The data is put onto coding forms, along with other appropriate data, if desired. This 'digital' manual interpretation technique has proven to be efficient, and time and cost effective, while meeting strict requirements for data format and accuracy.

Istvan, L. B.↗

Rapid data comparison technique development for N-ray/X-ray analysis

An operational N-ray/X-ray computer analysis system for nondestructive testing problems was realized by developing: (1) more efficient data transfer routines for use in existing image processing systems; (2) the capability to store and analyze multiple N-ray/X-ray images; (3) an efficient 2-D Fast Fourier Transform; and (4) transfer functions compensation capability to correct for distortions and nonlinearities of N-rays/X-rays. Applications of the technique are summarized for the following: thermal protection system tile with hydraulic fluid; thermal protection system tile with corrosion; thermal protection system tile debonding; stainless steel tubing corrosion; defective electrical devices; fast film restoration and deblur; corrosion tracking over time; reduction of source vignetting, and identification of materials (0 rings, Teflon parts, soft goods) via table look up.

Butterfield, R. L.↗