Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Ultra-high vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Correlating Surface Processing of Nb Superconducting RF Cavities with the Evolution of Surface Electronic States

Superconducting-radio frequency (RF) cavities provide an efficient way to accelerate particle beams with extremely high acceleration gradients while generating very small power dissipation. The few nanometers of the surface play a critical role in defining the RF performance of superconducting Nb based cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in superconducting cavity performance by simultaneously achieving high quality factors with increasing maximum acceleration gradients. These processing approaches include chemical polishing, distinct multi-step thermal treatments under ultra-high vacuum (UHV) conditions over low to high temperature regimes, as well as high-temperature treatments under controlled nitrogen atmospheres. Beyond their macroscopic impact on RF performance, these methods produce distinct surface oxide configurations characterized by different valence states, oxide thicknesses, chemical uniformity, and oxygen concentration profiles extending into the near-surface bulk of niobium. In this work, we are trying to understand how the surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity. Using a combination of X-ray photoemission and X-ray absorption spectroscopies, we investigate how the valence-band structure and the electronic density of states (DoS) near the Fermi level evolve under different surface treatments. By employing tunable photon energies across multiple elemental absorption edges, we use resonant photoemission to disentangle and identify the elemental contributions to specific valence-band features. Our observations show that different surface-processing methods lead to distinct temperature evolutions of the DoS and valence-band states near the Fermi level. Our results suggest variations in different Nb-O orbital hybridizations in distinct processes and point towards the possibility of different underlying mechanisms of superconductivity governed by surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in superconducting RF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of superconducting RF cavities.

Tripathi, Malvika [Fermilab] (ORCID:00000001989251

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC

Nuclei growth kinetics during the nucleation of gold on UHV-cleaved mica substrates

Measurements of crystalline sizes during nucleation of gold on mica surfaces cleaved in ultra-high vacuum (UHV) reveal the presence of symmetric, sharply peaked distributions which flatten and broaden with increasing nucleation time. When the number density of nuclei increases, the growth rate is suppressed. The time taken to reach a given size increases with increasing temperature when the nuclei are growing as isolated particles. When the nuclei are spaced so far that their diffusion fields overlap, then the time taken to reach a given size decreases with increasing temperature.

Elliot, A. G.

Laser particulate spectrometer

Hybrid laser scattering and extinction technique measures particle diameters from 0.8 to 2.75 micrometers and speeds from 0.2 to 20 m/s. Operating pressures range from ambient to ultra-high vacuum, and temperatures range from 77 to 300 K. Potential applications include air pollution, clean room, and particle size monitoring.

Boyd, B. A.

A facility for the simulation of low orbit atmospheric oxygen bombardment

A molecular beam facility to simulate the space environment of a spacecraft at low orbit was designed with the intent of studying the effect on the properties of optical elements of oxygen atoms impacting at orbital velocity. The four-stage differentially pumped molecular beam facility includes a variety of oxygen atom beam sources which cover a wide range of velocities (1 km/sec to approximately 8 km/sec), in addition to the ultra-clean experimental environmental of an ultra-high vacuum chamber and an optical diagnostic set-up. The primary oxygen atom beam source used to obtain the 8 km/sec O atoms is an arc heated source. It consists of a modified commercially available plasma torch. The modifications include attachments which provide for a nozzle which is used to expand the atomic beam into the vacuum system, and exhaust channels to dispose of excess torch gas. The torch operates in the 'nontransferred' mode of operation, that is the electric arc is confined within the torch. A plasma is formed in helium by a dc arc. A small amount of O2 is injected downstream from the arc where it is thermally dissociated by the hot He into oxygen atoms. The high temperature and isentropic expansion give the oxygen atoms their velocity. Using seeded beam techniques, oxygen atom beams of approximately 3.5 and approximately 1.5 km/sec, respectively, are obtained.

Arnold, G. S.

On the distribution of noble gases in Allende - A differential oxidation study

The investigation makes use of an oxidizing technique which is based on methods widely employed in light stable isotope analysis. The utilization of closed-system differential combustion in molecular oxygen in an ultra-high vacuum system on-line with a spectrometer makes it possible to conduct precise abundance and isotopic measurements of all gases released in progressive oxidation and/or thermal outgassing of the host phases. Attention is given to the noble gases mobilized in progressive oxidation of a carbon-rich acid residue and a fine-grained matrix separate. The progressive oxidation of the Allende matrix is discussed. Release occurred over three distinct intervals, characterized by oxidation below 600 C, gas mobilization between 630 and 750 C, and high-temperature diffusive release.

Frick, U.

Degradation of the lunar vacuum by a moon base

Several industrial processes requiring high and ultra-high vacuum similar to the lunar vacuum are outlined. The effects of a 20-person lunar base and a 250-person industrial facility on this vacuum are discussed. It is shown that exhaust from transport spacecraft and leakage from the habitat will be comparable to the daytime gas pressure for the 20-person base, and will degrade the vacuum to the range of 2 x 10 to the -9th torr for the use of 250-person facility. This will result in replacing the mostly nonreactive gases hydrogen, helium, and neon with more reactive gases containing carbon and oxygen. This vacuum is still good enough to perform many important vacuum processes such as plasma-deposition of amorphous silicon for solar cells, but processes such as molecular beam epitaxy or locating an intersecting beam accelerator on the moon will require additional vacuum pumping.

Landis, Geoffrey

Experiments for electromagnetic levitation in microgravity

Containerless processing is a promising research tool for investigating the properties of undercooled melts and their solidification. For conducting samples RF-electromagnetic levitation offers the possibility to obtain large undercoolings by avoiding heterogeneous nucleation at container walls. On earth, however, strong magnetic fields are needed to compensate the gravitational force which imposes a lower limit on the available temperatures and on the accessible undercooling range. Under microgravity conditions the magnetic positioning fields can be minimized and hence, undercooling becomes feasible under ultra-high vacuum conditions and lower temperatures become accessible. In contrast to other undercooling and solidification techniques, electromagnetic levitation allows for diagnostic measurements during the early steps of nucleation and phase selection. Experiments cover a wide field of research topics: nucleation, directional solidification at high velocities, generation of metastable phases, evolution of microstructures, properties of undercooled liquids. Examples from these classes including experiments selected for the IML-2 mission are discussed with emphasis on technical requirements. An overview is given on the German TEMPUS (electromagnetic levitation facility) program.

Willnecker, R.

Method for producing an atomic oxygen beam

A method for producing an atomic oxygen beam is provided by the present invention. First, a material 10' is provided which dissociates molecular oxygen and dissolves atomic oxygen into its bulk. Next, molecular oxygen is exposed to entrance surface 11' of material 10'. Next, material 10' is heated by heater 17' to facilitate the permeation of atomic oxygen through material 10' to the UHV side 12'. UHV side 12' is interfaced with an ultra-high vacuum (UHV) environment provided by UHV pump 15'. The atomic oxygen on the UHV side 12' is excited to a non-binding state by exciter 14' thus producing the release of atomic oxygen to form an atomic oxygen beam 35'.

Outlaw, Ronald A.

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm

Ultra-high molecular sink vacuum chamber

Double-wall vacuum chamber can be separated from the remainder of the system and pumped by ultra-clean techniques. Ultrahigh vacuum is maintained by the cryogenic effect of a cold wall and titanium chemisorption.

Stephens, J. B.

Characterization of electron spin polarization from positive electron affinity GaAs photocathodes

Negative Electron Affinity (NEA) GaAs photocathodes are widely used to generate spin-polarized electron beams, typically achieving Electron Spin Polarizations (ESPs) in the range of 35%–40%. However, when operated in a Positive Electron Affinity (PEA) state, where a potential barrier inhibits low-energy electrons from escaping into vacuum, measured ESPs can exceed 50%. This effect can occur naturally during photocathode operation, as the NEA surface activation layers can degrade easily over time, increasing the electron affinity. In this work, we investigate and characterize the behavior of enhanced ESPs under PEA conditions. We present experimental measurements of ESP using a retarding-field Mott polarimeter on GaAs photocathodes with controlled and varying electron affinities. These results are complemented by theoretical explanations considering the material band structure, the light excitation profile, and spin depolarization mechanisms.

Electronic band structure

Toward the origins of binding energy shifts and “satellites” formation during plasma-XPS measurements

In-plasma x-ray photoelectron spectroscopy (plasma-XPS) emerges as a powerful platform for real-time, in situ chemical analysis under conditions relevant to semiconductor processing and other plasma-enabled technologies. This study investigates the origins of binding energy (BE) shifts and the formation of “satellite” peaks observed during plasma-XPS measurements across conductive, dielectric, and gas-phase systems. Using a standard laboratory-based ambient pressure XPS apparatus coupled with an alternating current (AC)-driven capacitively coupled plasma source, we demonstrate that metastable surface species, such as transient Au oxides, can be detected during plasma exposure, revealing chemical states that are hardly accessible using conventional ultrahigh vacuum (UHV) XPS. In dielectric samples (e.g., undoped diamond, sapphire), we observe pressure- and plasma-type-dependent BE shifts of more than 50 eV, attributed to x-ray-induced and plasma-mediated surface charging. These shifts are mitigated at higher pressures/plasmas or in electronegative plasmas (e.g., O 2 ), the latter due to enhanced charge compensation mechanisms involving slow negative ions. For gas-phase species, AC-plasma excitation leads to spectral broadening and the emergence of “satellite” peaks with energy separations of a few electron volts, linked to oscillating local plasma potentials in the probing volume. Furthermore, these findings highlight the complex and important interplay between plasma parameters, surface charging, and local electric fields in shaping XPS spectra. Overall, plasma-XPS emerges as a critical metrological tool for probing transient surface chemistry, with implications for semiconductor processing, material synthesis, and plasma diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Structure Sensitivity and Catalyst Restructuring for CO2 Electro-reduction on Copper

Abstract Cu is the most promising metal catalyst for CO 2 electroreduction (CO 2 RR) to multi-carbon products, yet the structure sensitivity of the reaction and the stability versus restructuring of the catalyst surface under reaction conditions remain controversial. Here, atomic scale simulations of surface energies and reaction pathway kinetics supported by experimental evidence unveil that CO 2 RR does not take place on perfect planar Cu(111) and Cu(100) surfaces but rather on steps or kinks. These planar surfaces tend to restructure in reaction conditions to the active stepped surfaces, with the strong binding of CO on defective sites acting as a thermodynamic driving force. Notably, we identify that the square motifs adjacent to defects, not the defects themselves, as the active sites for CO 2 RR via synergistic effect. We evaluate these mechanisms against experiments of CO 2 RR on ultra-high vacuum-prepared ultraclean Cu surfaces, uncovering the crucial role of step-edge orientation in steering selectivity. Overall, our study refines the structural sensitivity of CO 2 RR on Cu at the atomic level, highlights the self-activation mechanism and elucidates the origin of in situ restructuring of Cu surfaces during the reaction.

Science & Technology - Other Topics

Space ultra-vacuum facility and method of operation

A wake shield space processing facility (10) for maintaining ultra-high levels of vacuum is described. The wake shield (12) is a truncated hemispherical section having a convex side (14) and a concave side (24). Material samples (68) to be processed are located on the convex side of the shield, which faces in the wake direction in operation in orbit. Necessary processing fixtures (20) and (22) are also located on the convex side. Support equipment including power supplies (40, 42), CMG package (46) and electronic control package (44) are located on the convex side (24) of the shield facing the ram direction. Prior to operation in orbit the wake shield is oriented in reverse with the convex side facing the ram direction to provide cleaning by exposure to ambient atomic oxygen. The shield is then baked-out by being pointed directed at the sun to obtain heating for a suitable period.

Naumann, Robert J.