Engineering PapersSearch

SEARCH · Engineering Papers

Results for “N2 Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

67 records · Page 4

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI

Energy conversion and transport in molecular-scale junctions

Molecular-scale junctions (MSJs) have been considered the ideal testbed for probing physical and chemical processes at the molecular scale. Due to nanometric confinement, charge and energy transport in MSJs are governed by quantum mechanically dictated energy profiles, which can be tuned chemically or physically with atomic precision, offering rich possibilities beyond conventional semiconductor devices. While charge transport in MSJs has been extensively studied over the past two decades, understanding energy conversion and transport in MSJs has only become experimentally attainable in recent years. As demonstrated recently, by tuning the quantum interplay between the electrodes, the molecular core, and the contact interfaces, energy processes can be manipulated to achieve desired functionalities, opening new avenues for molecular electronics, energy harvesting, and sensing applications. This Review provides a comprehensive overview and critical analysis of various forms of energy conversion and transport processes in MSJs and their associated applications. We elaborate on energy-related processes mediated by the interaction between the core molecular structure in MSJs and different external stimuli, such as light, heat, electric field, magnetic field, force, and other environmental cues. Key topics covered include photovoltaics, electroluminescence, thermoelectricity, heat conduction, catalysis, spin-mediated phenomena, and vibrational effects. Furthermore, the review concludes with a discussion of existing challenges and future opportunities, aiming to facilitate in-depth future investigation of promising experimental platforms, molecular design principles, control strategies, and new application scenarios.

Charge transport

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases

Manipulating Na/TM Ratio‐Driven Structural Heterogeneity of O3‐NaNi 1/3 Fe 1/3 Mn 1/3 O 2 Cathode for High‐Voltage Sodium‐Ion Batteries

The stability of O3-type NaNi 1/3 Fe 1/3 Mn 1/3 O 2 under high-voltage cycling is dictated by how synthesis encodes lattice strain and redox heterogeneity. Here, in this study, the role of Na:TM stoichiometry is systematically resolved by tuning the NaOH:precursor ratio during solid-state synthesis. The stoichiometric condition (Na:TM = 1.00) yields minimized microstrain, enabling uniform O3–P3 phase evolution and homogeneous multi-metal redox with preserved octahedral symmetry. In contrast, Na-excess compositions inherit disordered intermediates and heterogeneous distortion fields that trigger abrupt multiphase transitions and promote localized charge redistribution. In situ XRD captures the divergence in phase-transition pathways, TXM resolves particle-level redox heterogeneity, and XANES corroborates a stronger and more reversible Fe redox contribution at stoichiometry, shifting to diminished Fe participation and spatially inhomogeneous redox at higher Na content. These results establish Na:TM stoichiometry as a critical synthesis parameter controlling both structural coherence and redox stability. Electrochemically, the stoichiometric composition exhibits smooth voltage profiles with minimal polarization growth and retains nearly 80% of its initial capacity after 100 cycles even at an extended 4.2 V cutoff, whereas Na-excess compositions show significantly reduced initial coulombic efficiency and rapid voltage fade. Precise stoichiometric tuning provides a scalable route to defect-suppressed O3 frameworks, enabling structurally resilient, high-voltage sodium-layered cathodes.

36 MATERIALS SCIENCE

Direct Observation of Elusive (DTBM‐SEGPHOS)CuH Monomer Enables Mechanistic Insights Into Hydrocupration, Aggregation, and Dynamics of Alkene Functionalization Catalysis

The bulky diphosphine DTBM-SEGPHOS is widely employed in CuH-catalyzed transformations as it provides remarkably active catalyst systems. The transient (DTBM-SEGPHOS)CuH monomer (LCuH) is the often-invoked active species. However, its instability has prevented spectroscopic characterization and mechanistic elucidation, hindering mechanistic understanding. We report low-temperature NMR spectroscopic characterization of LCuH, enabling quantitative kinetic analysis of the stoichiometric hydrocupration and catalytic hydroboration of cyclopentene, as well as the structural identification of two CuH clusters. LCuH inserts cyclopentene at −43°C, reaffirming its high reactivity toward olefins. LCuH deactivates to form L 2 Cu 3 H 3 and L 2 Cu 4 H 4 clusters, in which LCuH dimerization initiates aggregation. Kinetic analysis of reactions of unactivated alkenes indicates that competing on-cycle alkene hydrocupration and LCuH dimerization impact performance, as catalyst deactivation and turnover occur on comparable timescales. Structure–activity analysis using atomistic simulations shows that the steric profile of DTBM-SEGPHOS increases the CuH dimerization barrier by ∼7.7 kcal mol−1 compared to that of SEGPHOS, rationalizing the unique ability of DTBM-SEGPHOS to stabilize a reactive monomer for hydrocupration of broader alkene substrates. These findings illustrate the fundamental design principle that steric control of aggregation governs CuH catalyst performance, explaining both the exceptional activity of (DTBM-SEGPHOS)CuH and the limitations imposed by competing deactivation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Staged Z-pinch experiment at the double-EAGLE pulsed power facility

The staged Z-pinch is a potential high-energy gain fusion concept where a high atomic number liner implodes on a deuterium target using a pulsed multi-MA current source. Over the past several years this concept has been studied on 0.5–1.0 MA facilities using Ar and Kr gas puffs injected at R = 1.2 cm. Neutron yield up to (2.5 ± 0.34) x 10 10 was measured, Ruskov et al (2023 IEEE Trans. Plasma Sci. 51 3310–6). Here, in this study, we present experimental results from the 4 MA, 110 ns current rise time Double-EAGLE facility at L3Harris (currently, Fisica Inc.) where a larger radius nozzle created gas density profiles peaked at R = 2.5 cm. Modeling with the MACH2 and FLASH codes indicates that the larger radius allows stronger acceleration of the liner plasma and generation of shock waves that preheat a target plasma layer next to the liner to temperatures $T_i >$1 keV. The resulting counter thermal pressure on the liner plasma limits the growth of the Magneto-Rayleigh–Taylor (MRT) instability at the liner-vacuum boundary and the implosion proceeds in a relatively stable manner. Near bang time the enormous target plasma thermal pressure smoothens the MRT perturbations developed during the earlier implosion stages. Time integrated x-ray pinhole images with cutoff energy of 100 eV confirm that a long (∼3 cm), stable and uniform high energy density plasma column is formed in the final implosion stage. Consistent neutron yield in the 10 10 –10 11 range was measured for both Ar and Kr liners imploding on a deuterium target.

Physics - Plasma physics

Resonant scattering at the center of the galaxy cluster PKS 0745-191 with XRISM

We report evidence of the resonant scattering effect at the center of the galaxy cluster PKS 0745-191 with XRISM. We analyzed XRISM/Resolve commissioning-phase observations of the distant cluster PKS 0745-191 ($z = 0.103$) with a $54$ ks exposure. The gain drift was corrected using the onboard modulated X-ray source (MXS), and spectra were extracted from all the pixels that were well illuminated by MXS, the core region (four central pixels, $\sim$100 kpc), and the surrounding region. A single-temperature collisional ionization equilibrium (CIE) model fits the full field-of-view spectrum with $kT \approx 6$ keV and a turbulent velocity of ${\approx}120$ km s$^{-1}$. From the core ($r < 50$ kpc) spectrum, we detected a ${\approx}22\%$ suppression of the Fe xxv He$\alpha$ resonance (w) line relative to the CIE prediction. We performed a Monte Carlo simulation to calculate the resonant scattering (RS) effect using radial profiles from Chandra data. The RS-inferred turbulence agrees with that by Resolve line-broadening, demonstrating that RS provides an independent and consistent constraint on ICM turbulence. These results highlight XRISM/Resolve’s potential for turbulence studies in galaxy clusters.

Astronomy and AstroPhysics

Valorization of consolidated bioprocessing residues for bioplastics

This study demonstrates an organic solvent-free processing strategy to valorize consolidated bioprocessing (CBP) residues, from switchgrass and poplar biomass, into functional poly(butylene succinate) (PBS)-based biocomposites using high-shear homogenization (HSH). HSH transformed the switchgrass and poplar CBP residues (CBP-R) into fine, uniformly distributed particles and microfibers. The composites of PBS with homogenized switchgrass residues (H-CBP-R-SG) or homogenized poplar residues (H-CBP-R-P) at a 70/30 weight ratio exhibited improved processability and mechanical integrity, with the Young's modulus for the PBS/H-CBP-R-SG and PBS/H-CBP-R-P nearly doubling to 0.66 ± 0.07 GPa and 0.65 ± 0.04 GPa, respectively, compared to neat PBS (0.36 ± 0.02 GPa). Dynamic Mechanical Analysis (DMA) reveals a significant suppression of the tan δ peak magnitude, indicating that HSH-mediated physical activation facilitates stress transfer in composites typical of covalent chemical grafting systems. While the transition to a stiffness-dominated profile reduces ductility, the resulting composites exhibit the dimensional stability and resistance to thermal warping required for high-fidelity FDM 3D printing and injection molding. Beyond material performance, comprehensive techno-economic analysis (TEA) and life cycle assessment (LCA) confirmed that diverting CBP residues into composite products can improve the economic viability of the biorefinery without substantially increasing biorefinery global warming potential (GWP). At a 30 wt% blend ratio, incorporating residuals into PBS yielded a minimum selling price for the composite of $\$4.07$ per kg compared to the conventional bioplastic price of $\$5.00$ per kg. This approach aligns with circular bioeconomy principles by converting waste streams into value-added products. Furthermore, this innovative strategy addresses key challenges in bioplastic development, including cost, compatibility, and performance, while simultaneously advancing waste minimization strategies for sustainable manufacturing systems.

09 BIOMASS FUELS

Imaging of a van der Waals spin-orbit torque system using spin ensembles in hBN

Recently, optically active spin defects embedded in two-dimensional (2D) van der Waals (vdW) crystals have emerged as a transformative quantum sensing platform to explore cutting-edge materials science. Taking advantage of excellent solid-state integrability, this new class of spin defects can be readily arranged in nanoscale proximity to target materials, showing great promise for realizing in-situ quantum sensing of microscopic spin and charge behaviors in vdW heterostructures. Here we report hexagonal boron nitride-based quantum imaging of field-free deterministic magnetic switching and electric current distributions in an all-vdW spin-orbit torque (SOT) system. By visualizing variations of nanoscale magnetic stray field profile of room-temperature 2D magnet Fe 3 GaTe 2 under different SOT conditions, we show how the magnetic switching evolves from deterministic to stochastic behavior due to the interplay between spin orientations, anisotropy and Joule heating. Micromagnetic simulations rationalize our results well, revealing the role of field-like SOT in inhibiting thermal fluctuation driven stochastic switching and chaotic multi-domain competition. This understanding, which is otherwise difficult to access by conventional transport measurements, offers valuable insights into material design, testing, and performance evaluation of next-generation vdW spintronic devices.

Imaging techniques

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI